JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012091205131Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROWS 54 RIGHT THRU 59 RIGHT. SECURED CONNECTOR EEL LIGHTS AT SEAT ROWS 54 RIGHT THRU 59 RIGHT OPS CHECKS NORMAL.SDR AALA20120912016Wire · crushedSEAT MOUNTED EMERGENCY LIGHTS FROM ROW 26 TO AFT OF AIRCRAFT ARE INOPERATIVE. FOUND CRUSHED WIRING AT L760S. REPLACED WIRES. OPS CHECK NORMAL.SDR ASOA2012091402216Connector · disconnectedEMERGENCY LIGHT OVER GALLEY SERVICE DOOR INOPERATIVE. FOUND CONNECTOR AT GALLEY SERVICE LIGHT HAD PUSHED OUT. ATTACHED AND FUNCTION TESTED IAW AMM 33-50-00. NO FURTHER DEFECT NOTED.SDR DALA12006973272Wire · brokenDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 1AB AND 2AB INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL.SDR UIEA2012091700432Connector · unsecureMAIN DECK SEAT 23C EMERGENCY LIGHT INOPERATIVE. SECURED LOOSE CONNECTOR AT LIGHT ASSY. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700431Connector · unsecureMAIN DECK 2 FLOOR PROXIMITY LIGHTS OUT AFTER 16H SEAT. SECURED LOOSE CONNECTION AT LIGHT ASSY ON FLOOR AT 16H. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700430Connector · unsecureMAIN DECK BESIDE 14K SEAT, 2 FLOOR PROXIMITY LIGHTS INOPERATIVE. REINSTALLED LIGHT ASSY CONNECTOR AT SEAT 14K. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700429Connector · unsecureMAIN DECK AT FIRST CLASS SECTION, BETWEEN LT SEAT ROWS 12 AND 16, ALL FLOOR PROXIMITY LIGHTS ARE OUT. RESECURED CONNECTOR AT SEAT 12A. OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700427Connector · looseEMERGENCY LIGHTS OUT AFTER LT SEAT ROW 11 AT STAIR AREA. SECURED LOOSE CONNECTOR AT FLOOR LIGHT ASSY, OPS CHECKED OK IAW MM 33-51-00.SDR UIEA2012091700425Connector · looseUPPER DECK, 2 FLOOR PROXIMITY LIGHTS OUT BETWEEN LT SEAT ROW 6 AND 7 IN FRONT OF EMERGENCY EXIT DOOR. SECURED LOOSE CONNECTION AT FLOOR LIGHT ASSY, OPS CHECK OK IAW MM 33-51-00/ SOP.SDR SWIA201231731Connector · failedWHEN TURNING ON EMERGENCY LIGHTS SWITCH IN THE COCKPIT ONLY FORWARD AND MIDDLE PORTION OF LIGHTS ILLUMINATE. (FLT 6368) REPLACED EMERGENCY BUS CONNECTOR 2 K0519 IN LEFT DC RELAY BOX.SDR DALA12006696308Connector · damagedDURING INSPECTION FOUND EXIT EMERGENCY LIGHT INOPERATIVE ABOVE SEAT 13A/D. MAINTENANCE REPAIRED LOOSE PIN ON CONNECTOR D11274J.SDR USAA2012091000044Wire · disconnectedEMERGENCY EXIT LIGHT AT ROW 10 RIGHT IS INOPERATIVE. FOUND WIRE DISCONNECTED FROM LIGHT. RECONNECTED TERMINAL FITTING TO LIGHT. OPS CHECKED GOOD.SDR DALA1248140914Wire · looseDURING LINE CHECK, MAINTENANCE FOUND THAT THE OVERHEAD EMERGENCY PATHWAY LIGHTING AT SEAT 32 WAS INOPERATIVE. MAINTENANCE FOUND A LOOSE NUT AND WIRE ON THE TERMINAL STRIP. THE NUT WAS REPLACED AND THE WIRE WAS SECURED. THE SYSTEM RETURNED TO NORMAL OPERATIOSDR REXA2012090901324Connector · damagedAFT SECTION OF FLOOR EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED SECTION OF FLOOR LIGHT CONNECTOR AW AMM 33-51-01. OPS CHECKED GOOD.SDR DALA12006660990Wire · disconnectedOVERHEAD AFT CATWALK EMERGENCY LIGHT INOPERATIVE. MAINTENANCE FOUND WIRE DISCONNECTED. RECONNECTED PER WDM. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA12006520984Wire · disconnectedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 20 IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND A WIRE DISCONNECTED IN THE WIRE HARNESS UNPLUGGED, RECONNECTED IT, AND FUNCTIONALLY CHECKED THE SYSTEM.SDR SWAA2012100108101Wire · brokenL1 DOOR EMERGENCY EXIT LIGHT WIRE BROKEN. REMOVED AND REPLACED LIGHT IAW AMM.SDR SIMA20120907006Wire · brokenDURING MAINTENANCE INSPECTION FOUND THE EMERGENCY LIGHT STRIP NR 8 (MOST AFT) HAS BROKEN WIRE LEADING TO SPLICE SP9213 ON AIRCRAFT SIDE. DIFFERED AFT EMERGENCY LIGHT STRIP PER MEL 33-30. REPAIRED SPLICE SP9213 IAW EMB WM 20-21-00. THE OPERATIONAL CHECK WAS GSDR SWIA201231722Wire · brokenEMERGENCY LIGHT ON FLOOR IN FRONT OF GALLEY ARE INOPERATIVE. (SERVICE) FOUND BROKEN CRIMP ON FRONT OF GALLEY FLOOR EMERGENCY LIGHT. RE-CRIMPED WIRE.SDR SIMA20120907005Wire · brokenDURING B INSPECTION FOUND THE PASSENGER DOOR EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND WIRE GOING TO THE PASSENGER DOOR EMERGENCY LIGHT BROKEN. REPAIRED WIRE IAW EMB SWPM 20-21-00. THE OPERATIONAL CHECK IAW EMB 145 AMM 33-50-SDR DALA1248193723Connector · unsecureDURING EMERGENCY LIGHT TEST FOUND PATH LIGHT AT SEAT 11D INOPERATIVE, SECURED CONNECTOR AND TESTS OK.SDR ASOA20120906074Wire Harness · faultyTHE CREW REPORTED A STRONG ELECTRICAL ODOR IN CABIN. 17A CEILING LIGHT WAS INOPERATIVE. MX REPLACED ROW 17A CEILING LIGHT ELECTRICAL HARNESS ASSY. OPS CHECKS WERE GOOD.SDR SIMA20120906003Ground Wire · dirtyDURING B INSPECTION FOUND THE MAIN DOOR STAIR EMERGENCY LIGHT INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE MAIN DOOR EMERGENCY LIGHT BULB IN REFERENCE WITH EMB AMM TASK: 33-50-10-000-801-A, AND 33-50-10-400-801-A. NO FIX. REMSDR DALA12006350864Ground Wire · damagedON SERVICE CHECK, FOUND SEAT ROWS 1-4 EMERGENCY LIGHTS TO BE INOPERATIVE. MAINTENANCE FOUND EMERGENCY LIGHT BATTERIES DEAD. REPLACED BATTERIES WITH SPARE ONE. LIGHTS WOULD NOT EXTINGUISH AFTER TEST. FOUND GROUND WIRE PINCHED BETWEEN ROW 1 AND ROW 2. REPAISDR SWIA201231710Connector · disconnectedLAST 4 EMERGENCY FLOOR LIGHT STRIPS WILL NOT TEST. (FLT 6285) DISCONNECTED WIRE CONNECTIONS AT ROW 13 AND RECONNECTED.SDR AALA20120904009Connector · not seatedSEAT MOUNTED EMERGENCY LIGHTS AT SEAT 10G INOPERATIVE. RESEATED BOTH LIGHT ASSEMBLY CONNECTORS. OPS CHECK NORMAL.SDR UALA2012090404957Connector · unsecureEMERGENCY LIGHT INOPERATIVE SEAT ROW 36 LEFT. SECURED CONNECTOR, OPS NORMAL.SDR GLBA201209032Terminal · dirtyEMERGENCY LIGHTS WILL NOT COME ON DURING TEST. MX CLEANED CORROSION AND SECURED THE CONNECTION ON THE HOT BUSS BAR.SDR DALA12006390965Connector · damagedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 1 IN THE CABIN WAS INOPERATIVE. MAINTENANCE FOUND A CONNECTOR IN THE SEAT WIRE HARNESS TO BE THE CAUSE OF THE FAULT. SYSTEM WAS REPAIRED AND THE FUNCTIONAL CHECK WAS NORMAL.SDR DALA1247931703Wire Harness · damagedSEAT 18B EMERGENCY ESCAPE PATH MARKING LIGHT INOPERATIVE. RESEATED PINS ON18B SEAT HARNESS LIGHT NOW OK.SDR AALA20120902001Pin · pulledAT ROW 25DEF SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. FOUND PIN AT CONNECTOR IN SIDEWALL AT SEAT IN ROW 25 PULLED OUT OF CONNECTOR. RE-INSTALLED PIN. OPS CHECK NORMAL.SDR UALA2012083104906Connector · unsecureEMERGENCY EXIT LIGHT INOPERATIVE SEAT ROW 43 LEFT. SECURED CONNECTOR UNDER SEAT 43C. OPS NORMAL.SDR SWAA2012090407303Connector · brokenRIGHT OVERHEAD EMERGENCY EXIT BULLNOSE LIGHT CONNECTOR BROKEN AT ROW 13. REMOVED AND REPLACED CONNECTOR PER SWPM AND AMM.SDR QXEA2012083100968Wire · damagedELECTRICAL ODOR IN AFT CARGO COMPARTMENT. INSPECTED AFT CARGO COMPARTMENT FOR ANY OBVIOUS DEFECTS, NONE NOTED. REMOVED BOTH LIGHT ASSY AND INSPECTED FOR SIGNS OF ARCING OR BURNING. FOUND LOOSE GROUND WIRE AND BAD SOCKET ON FWD LIGHT ASSY IN AFT CARGO COMPARSDR AALA20120830007Connector · disconnectedROW 32 EMERGENCY EGRESS LIGHT INOPERATIVE. RECONNECTED CONNECTOR AT SIDEWALL. OPS CHECK NORMAL.SDR REXA0829201201300Connector · unsecureTHREE EMERGENCY LIGHT ARE OUT. SECURED AFT STRIP CONNECTOR AMM 33-50-00. CHECKED GOOD, OK FOR SERVICE.SDR USAA2012083000006Wire · shortedMAINTENANCE REPORTED THE EMERGENCY EXIT LIGHTS INOPERATIVE ON SEATS 19-23L. MAINTENANCE REPAIRED SHORTED WIRE ON SEAT 22. ALSO REPLACED BLOWN FUSE ON POWER SUPPLY M1197. OPS CHECK GOOD PER 20-13-10.SDR SIMA20120829005Wire · brokenDURING B INSPECTION, FOUND THE FORWARD AISLE EMERGENCY EXIT SIGN INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. FOUND BREAK IN WIRE W192-8584-22. REPAIRED WIRE BY BUTT SPLICING IAW WM 20-21-00. THE OPERATIONAL CHECK WAS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR R61A201208280463Wire Harness · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION CONNECTORS FOR LEFT WING TIP AFT STROBE LIGHT AND POWER SUPPLY. MX REMOVED AND REPLACED HARNESS W515 (FWD STROBE) AND HARNESS W518 (MAIN STANDBY NAV AND STROBE AFT) IAW EMB SWPM 20-50-00. A/C REMAINS ISDR R61A201208280462Wire Harness · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION CONNECTORS FOR LEFT WING TIP AFT STROBE LIGHT AND POWER SUPPLY. MX REMOVED AND REPLACED HARNESS W515 (FWD STROBE) AND HARNESS W518 (MAIN STANDBY NAV AND STROBE AFT) IAW EMB SWPM 20-50-00. A/C REMAINS ISDR SWIA201231678Wire Harness · failedEMERGENCY LIGHTING STRIP INTERMITTENT. (FLT 5319) REPLACED WIRE HARNESS AT AFT FLOOR LIGHT IN FRONT OF LAV PER AMM.SDR UALA2012082704797Connector · unsecureEMERGENCY LIGHT INOP: AFT GALLEY LEFT SIDE WALL STRIP. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2012082704796Connector · looseEMERGENCY LIGHT INOP: AFT GALLEY FWD WALL STRIP. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2012082704794Connector · looseEMERGENCY LIGHT INOP: SEAT 33LT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR AALA20120828003Connector · looseEMERGENCY LIGHT AT 24D INOPERATIVE. RE-SECURED CONNECTOR AT 24D SIDEWALL. OPS CHECK NORMAL.SDR AALA20120827013Wire · brokenSEATS 21DEF EMERGENCY LIGHT IS INOPERATIVE. REPAIRED BROKEN WIRE IN HARNESS.SDR DALA12006080918Power Supply · miswiredDURING LINE CHECK, MAINTENANCE FOUND THEY HAD NO CONTROL OF THE EMERGENCY PATHWAY LIGHTING IN THE CABIN, THEY WOULD COME ON WHEN ALL AIRCRAFT POWER WAS OFF. MAINTENANCE FOUND THE POWER SUPPLY (B5-104) IN THE CABIN CEILING TO BE MISWIRED. THE POWER SUPPLY WASSDR DALA1247336707Connector · disconnectedDURING LINE CHECK, MAINTENANCE FOUND EMERGENCY LIGHTS AT ROW 24-27 INOPERATIVE. MAINTENANCE RECONNECTED LOOSE CONNECTOR AT SEAT24. OPERATION OF LIGHTS NOW CHECK GOOD.SDR USAA2012082800009Wire · brokenMAINTENANCE REPORTED SEAT 13C AND 24C EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE FOUND BROKEN WIRES AT SEAT 13C AND 24C. REPAIRED WITH SPLICE AND OPS CHECK OK.
Back to JASC 3397