JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1050469885Wire · damagedDURING LINE CHECK, MX FOUND THAT THE EMERGENCY PATHWAY LIGHTING AT ROW 9 OF THE CABIN WAS INOPERATIVE. MX REPLACED THE WIRE HARNESS AND FUNCTIONALLY CHECKED THE SYS.SDR SWIA201025302Wire · looseEMERGENCY FLOOR RED LIGHT NOT WORKING AT ROW 1. (FLT 6818) RE-SECURED WIRE AT FLOOR LEVEL EMERGENCY LIGHT.SDR RAIA2010120300002Connector · looseCREW REPORTED THAT THE AFT CEILING EMERGENCY LIGHT WAS INOP. MAINTENANCE FOUND A LOOSE CONNECTION AT THE LIGHT ASSEMBLY. THE CONNECTION WAS TIGHTENED AND THE LIGHT FUNCTIONED PROPERLY.SDR SWIA201025259Connector · looseEMERGENCY LIGHTS AT ROW 6 INTERMITTENT. (FLT 6232) RE-SECURED ELBP CONNECTOR.SDR DALA1050571201Wire Harness · brokenEMERGENCY LIGHTS AT 29AB ARE INOPERATIVE. MX FOUND A HARNESS WIRE BROKEN AND REPLACED. SYS OPS IS NORMAL.SDR DALA1050561521Wire · brokenEMERGENCY LIGHTS CTR BULKHEAD, ROW 20 ARE INOPERATIVE. MX REPLACED A BROKEN WIRE ON THE RT SIDE OF THE BULKHEAD. SYS OPS IS NORMAL.SDR DALA1050551201Wire · brokenEMERGENCY LIGHTS AT SEAT 38AB ARE INOPERATIVE. MX FOUND A BROKEN WIRE AND REPLACED. SYS OPS IS NORMAL.SDR USAA20101206SB199Connector · unsecureBOS - MAINTENANCE REPORTED THE EMERGENCY PATH SEAT LIGHT AT ROW 4ABC INOPERATIVE. MAINTENANCE RE-SECURED SEAT LIGHTING CONNECTOR. OPERATIONAL CHECK NORMAL PER MM 33-51-12.SDR DALA1050510691Wire · brokenDURING LAYOVER CHECK, MX FOUND ROW 31F EMERGENCY LIGHT INOPERATIVE. FOUND MOLEX CONNECTOR BROKEN AND WIRING SPLICED WITH ELECTRICAL TAPE. REPLACED MOLEX CONNECTOR IAW SWPM 20-42-01. OPS CHECK GOOD.SDR USAA2010120392796Connector · looseFLT 34 - PHX - EEL - SEAT ROW 9 LT EMERGENCY LIGHT ON SEAT INTERMITTENT. MAINTENANCE FOUND LOOSE CONNECTION. RECONNECTED EMERGENCY LIGHT ON SEAT 9 LT.SDR SWIA201025252Connector · disconnectedFORWARD FLOOR EMERGENCY LIGHT STRIP INOPERATIVE. (FLT 4854) RECONNECTED FLOOR LIGHT CONNECTION AT ROW 5.SDR UALA2010120104417Wire Harness · damagedFOUND EMERGENCY LIGHTS INOP AT SEAT ROWS 23 AND 11. REPAIRED WIRING IN SEAT HARNESS AT BOTH ROWS 11 AND 23. EMERGENCY LIGHTS OPS CHECK OKAY.SDR DALA1034643270Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 1 INOPERATIVE. REPAIRED PULLED WIRE AT CONNECTOR UNDER SEAT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1034491200Wire · brokenSEAT MOUNTED EMERGENCY PATH LIGHTS AT 19AB ARE INOPERATIVE. MX REPAIRED A BROKEN WIRE. SYS OPS IS NORMAL.SDR DALA1034481504Wire · brokenEMERGENCY LIGHTS ROW 20FG THROUGH 28FG ARE INOPERATIVE. MX REPLACED THE BATTERY PACK, CHARGER, AND REPAIRED A BROKEN WIRE AT SET 20FG. SYS OPS IS NORMAL.SDR UALA2010113004400Feeder Cable · inoperativeEMERGENCY LIGHTING FLOOR STRIP AT "K" LAV INOP. SPLICED RIBBON NEW CABLE TO ATTACH TO POWER STRIP.SDR UALA2010113004394Connector · damagedSEAT 45 ABC EMERGENCY LIGHT IS INOP. SUPPLEMENTAL DATA UPDATE, REPAIRED CONNECTOR TO EMERGENCY LIGHT UNDER SEAT, OPS CK OK.SDR UALA2010113004392Wire · damagedSEAT 43 ABC EMERGENCY LIGHT IS INOP. SUPPLEMENTAL DATA UPDATE, REPAIRED WIRE TO EMERGENCY LIGHT, OPS CHECK OKAY.SDR SWAA107187Connector · brokenDURING SCHEDULED 8Y CHECK, FOUND RT OVERWING EMERGENCY EXIT LIGHT BALLST FWD CONNECTOR BROKEN. REMOVED AND REPLACED LIGHT BALLAST PER MM.SDR USAA2010120292760Wire Harness · damagedFLT 207 - ABQ-PHX - EMERGENCY LIGHTS - EMERGENCY EXIT LIGHT AT ROW 12L WIRING PULLED APART. REPLACED / SECURED HARNESS USING STANDARD PRACTICES. OPERATIONAL CHECK WAS GOOD.SDR AALA20101130TUL08Connector · dirtyCEILING EMERGENCY LIGHT ON AFT DROP PANEL INOPERATIVE. CLEANED BATTERY PACK CONNECTION ON B5-27 FOR EMERGENCY LIGHT ON AFT DROP PANEL. OPS CHECK NORMAL.SDR DALA1034236311Wire · damagedDURING A LAYOVER CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT SEAT 10AB TO 12AB INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR FDEA201011274501Wire Harness · malfunctionedEMERGENCY EXIT SIGNS INOP. RELEASED FOR SERVICE IAW MEL: 33-50-02, WHEN SHAKING HARNESS BY L1 DOOR LIGHTS COME ON, BUT UNABLE TO FIND EXACT CAUSE AT THIS TIME. REPLACED L1 DOOR "EXIT" LIGHT ASSY. ACCOMPLISHED ADJ AND TEST IAW MM 33-50-00-5.SDR CA101130005Connector · corrodedDURING A SCHEDULED ROUTINE CHECK THE TAIL STROBE LIGHT WAS FOUND U/S. INVESTIGATION REVEALED THAT THE CONNECTOR (P710/J710) AT THE BULLET FAIRING DISCONNECT WAS CORRODED AND THE WIRES SHORTED. THE CONNECTOR, BOTH P AND J SIDE WAS REPLACED AND THE SYSTEM FUNCTSDR DALA1034226301Wire · disconnectedDURING A LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AFT OF SEAT 43C INOPERATIVE. MX RECONNECTED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1034216301Wire · disconnectedDURING A LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT DOOR 2R INOPERATIVE. MX RECONNECTED THE WIRING. OPS CHECK WAS GOOD.SDR DALA1034196301Wire · disconnectedDURING A LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT SEATS 1B-4B AND 9K INOPERATIVE. MX RECONNECTED THE WIRING. OPS CHECK WAS GOOD. SEE ADDITIONAL LOG 0290471.SDR DALA1034186814Wire · disconnectedDURING LAYOVER CHECK FOUND EMERGENCY PATH LIGHT INOPERATIVE AT MID GALLEY FWD PARTITION WALL BEHIND SEAT 4D. MX RECONNECTED THE LIGHT ASSY. OPS CHECKS GOOD.SDR AALA20101126JFK01Wire Harness · disconnectedEMERGENCY LIGHT AT SEAT 3E IS INOPERATIVE. RECONNECTED AND REROUTED SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHT ASSEMBLIES HARNESS. OPS CHECK NORMAL.SDR DALA1034460997Wire · cutDURING LINE CHECK MX FOUND FWD RED EMERGENCY PATH LIGHTING, FLOOD LIGHT INOPERATIVE. MX FOUND CUT WIRE AND SPLICED IT IAW STANDARD WIRING PRACTICE, MM CHAP 20. OPERATION OF LIGHT NOW CHECKS OK.SDR DALA1034170636Wire · brokenDURING LAYOVER CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 6C INOPERATIVE. MX REPAIRED A BROKEN WIRE AND OPERATION OF LIGHTS NOW CHECKS NORMAL. (2010-D1415)(DL757103289)SDR EIAA2010076Wire · brokenEMERGENCY LIGHT OVER UPPER DECK STAIRS WOULD NOT TURN OFF AFTER EMERGENCY LIGHT SWITCHED OFF AND AIRCRAFT ENTRY TURNED OFF. T/S FOUND EMERGENCY LIGHT ASSY WIRE BROKEN. REPAIRED IAW WIRING MANUAL 33-00-00 AND OP'S CHECK OK ITEM CLEARED.SDR UALA2010112404344Connector · dirtyEMERGENCY LIGHT CHECK FAILED STEP C-62 AT DOOR 2 LEFT. FOUND CONNECTORS DIRTY ON PROX BOX ELEX UNIT AND CLEANED. OPS CHECKS GOOD.SDR SWIA201025211Wire · disconnectedRIGHT GALLEY EMERGENCY LIGHT INOPERATIVE. (FLT 4781) RECONNECTED WIRES AT RIGHT GALLEY EMERGENCY LIGHT.SDR USAA20101124SB195Wire · shortedPHX - APPROXIMATELY 10 MILES FROM AIRPORT WHILE ON FINAL APPROACH, THE SMOKE ALARM FOR THE AFT RIGHT LAVATORY WENT OFF AND WAS HEARD IN COCKPIT BY FLIGHT CREW. FLIGHT ATTENDANT CHECKED LAVATORY. NO FIRE BUT COULD SMELL SMOKE. CREW DECLARED AN EMERGENCY WITH SDR UALA2010112304320Connector · disconnectedAFT GALLEY SIDEWALL EMERGENCY LIGHT IS INOP. FOUND DISCONNECTED. RECONNECTED. CHECKS NORMAL.SDR DALA1034161503Wire Harness · damagedEMERGENCY LIGHTS AT SEAT 14B WERE INOPERATIVE. MX RE-PINNED THE HARNESS. SYS OPS IS NORMAL.SDR DALA1034151503Wire Harness · damagedEMERGENCY LIGHT AT 35B IS INOPERATIVE. MX RE-PINNED THE HARNESS. SYS OPERATION IS NORMAL.SDR RAIA2010112200001Wire · brokenDURING THE PREFLIGHT INSPECTION, THE CREW REPORTED THAT THE PASSENGER DOOR HANDRAIL EMERGENCY LIGHT AS BEING INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE AT THE LIGHT ASSEMBLY AND REMOVED AND REPLACED THE BULB. FOLLOW-ON OPERATIONAL CHECK OF THE LIGHT WASSDR C2XA10IA311Wire · burnedMTY - DURING PREFLIGHT INSPECTION THE CREW REPORTED THAT SIDEWALL LIGHT AT 9A TO BE SMOKING. MAINTENANCE PLACED THE SIDEWALL LIGHT IN MEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 11/25/10 IAH MAINTENANCE REPAIRED A WIRE ON THE AFFECTED SIDEWASDR SIMA201032701Wire · brokenDURING MAINTENANCE BASE VISIT FOUND THE EMERGENCY LIGHT STRIP AT 15A INOPERATIVE. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND BROKEN WIRE FROM THE CONNECTOR AT 15A. REPAIRED THE BROKEN WIRE USING STANDARD PRACTICES. THE OPERATIONAL CHECK WAS GOOD PER AMM SDR USAA2010112992681Wire · brokenMCN - EEL - C1 - EMERGENCY AISLE LIGHT RIGHT ROW 3 WIRE BROKEN. REPAIRED EMERGENCY AISLE LIGHT RIGHT ROW 3 WIRE IAW B767 WPM 20-30-12 AND B767 AMM 33-51-05.SDR HNAA2010112200256Wire · brokenEMERGENCY FLOOR LEVEL RED LIGHT INOP. WIRE PULLED OUT. REPLACED BROKEN WIRE FOR FWD RED EMERGENCY LIGHT. OPS CHECKED GOOD, OK FOR SERVICE.SDR HNAA2010112200255Circuit Breaker · failedEMERGENCY LIGHTS FLICKERED IN FLIGHT. FOUND SCREW MISSING FROM CIRCUIT BREAKER C-3 ( RT SECONDARY BUSS) AT BUSS BAR. R & R CIRCUIT BREAKER C-3 AND L-1 EMERGENCY LIGHTS. OPS CHECKED GOOD AT THIS TIME, IAW AMM 33-52-00.SDR DALA1033226705Wire · damagedDURING A-CHECK, FOUND EMERGENCY LIGHTS INOPERATIVE IN FIRST CLASS. REPLACED EMERGENCY POWER SUPPLY M731 AND REPAIRED WIRING AT SEATS 3CD AND 4CD PER WDM 33-51-16. TESTS GOOD. (2010-D1398) (DL757103240)SDR USAA2010112292625Wire · brokenPHX - EEL - AISLE EMERGENCY LIGHTS AT ROW 27L INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AT ROW 26 LEFT.SDR YENA20101120156Connector · unsecureFLT 986 FLL-JFK, ON MAINTENANCE CHECK FOUND EMERGENCY LIGHT TEST FAILED. RE-SECURED CONNECTOR, ACCOMPLISHED OPS CHECK AND TEST OK IAW AMM 33-51-38-740-050.SDR UALA2010111904281Feeder Cable · saturatedEMRGENCY LIGHTS INOPERATIVE SEATS 45L TO 53L, DOOR 4L FWD AND DOOR 5R AFT, MAIN GALLEY LEFT AND FWD LTS. CLEANED WET FEEDER CABLE.SDR UALA2010111904280Connector · inoperativeSEAT 39L EMERGENCY LIGHT INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 39L, OPS CHECKED GOOD.SDR UALA2010111904278Connector · faultyLEFT CROSSAISLE EMERGENCY LIGHT INOP BETWEEN DOORS 5L AND 5R. SECURED CONNECTOR, OPS CHECKEC NORMAL.
Back to JASC 3397