SDR USAA20101122BB077Wire · brokenTHE EMERGENCY EXIT LIGHT OVER DOOR L4 WAS INOPERATIVE. A BROKEN WIRE WAS FOUND. MAINTENANCE ACCOMPLISHED A TEMPORARY REPAIR AND DEFERRED THE FINAL REPAIR OF THE AIRCRAFT UNDER ENGINEERING AUTHORIZATION NOT TO EXCEED SEVEN DAYS. ALSO, MOC REQUESTED REPLACEMESDR DALA1164180188Splice · damagedEMERGENCY LIGHTS AT ROW 28GF ARE INOPERATIVE. MAINTENANCE REPAIRED WIRE SPLICE AT SEAT 28GF. SYSTEM OPERATION IS NORMAL.SDR DALA1033281611Connector · shortedDURING DRC MAINTENANCE FORWARD LEFT EMERGENCY PATH LIGHTS OUT. THE CONNECTOR AT SEAT 1A WAS SHORTED OUT AND TRIPPED. THE FUSE AT SLED BY SEAT 2D. MAINTENANCE REPLACED THE CONNECTOR AND BATTERY SLAD. SYSTEM OPERATION IS NORMAL. (2010-D1404) (DL76G103246)SDR DALA1033270932Wire · damagedDURING LINE CHECK MAINTENANCE FOUND EMERGENCY LIGHT AT SEAT 28D INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE PER ECRM. OPERATION OF LIGHT NOW CHECKS GOOD. (2010-D1403) (DLM88103245)SDR QXEA2010112200794Connector · disconnectedMID CABIN EMERGENCY LIGHT PANEL AS ALL LIGHTS INOP ON THE FWD SIDE. FOUND THE CONNECTOR PLUG DS191, NOT FULLY CONNECTED. RECONNECTED CONNECTOR PLUG. CHECKS GOOD.SDR UALA2010111804272Feeder Cable · damagedEMERGENCY LIGHT ON SEAT 33A IS INOP. REPLACED SEAT CABLE. CHECKS GOOD.SDR UALA2010111704259Feeder Cable · saturatedEMERGENCY AT DOOR LEFT, SEAT 45ABC THROUGH 54ABC AND LEFT CORNER OF AFT GALLEY ARE INOP. FOUND WET UNDER MAT NEAR LEFT CORNER OF GALLEY.SDR DALA1032799204Wire · damagedDURING LINE CHECK MAINTENANCE FOUND EMERGENCY PATH LIGHT AT SEAT 1C INOPERATIVE. MAINTENANCE RE-TERMINATED THE WIRES AND OPERATION OF LIGHT NOW CHECKS OK. (2010-D1376) (DLM90103210)SDR DALA1032773141Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE OVERHEAD CABIN EMERGENCY LIGHT AT ROW 20WL INOPERATIVE. REPLACED EPSU AND REPAIRED BROKEN WIRE. FUNCTIONAL CHECK WAS NORMAL AND AIRCRAFT RETURNED TO SERVICE. (2010-00861)SDR CA101118007Connector · burned(CAN) DURING INSPECTION A DISCOLORED AREA WAS NOTICED ON THE WINDOW WASH LIGHT PANEL AT THE SECOND FROM THE REAR WINDOW ON THE LT OF THE CABIN. UPON FURTHER INVESTIGATION THE AFT CONNECTOR ON THE FLUORESCENT TUBE WAS FOUND EXTREMELY BURNED, BUT STILL FULLY COSDR SWAA107130Wire · brokenDURING SCHEDULED SPV CHECK, FOUND R1 DOOR EMERGENCY EXIT SIGN INOP. REPAIRED LIGHT WIRING PER WDM.SDR DALA1033071604Wire · brokenEMERGENCY FLOOR LIGHTS AT MID GALLEY ARE INOPERATIVE. MAINTENANCE FOUND A WIRE BROKEN AND SPLICED. SYSTEM OPERATION IS NORMAL. (2010-D1387) (DL76G103223)SDR DALA1032673321Connector · unsecureDURING EMERGENCY LIGHT TEST FOUND LDMCR STAIRCASE LED EMERGENCY LIGHT INOP. SECURED CONNECTORS AND TEST OK. (2010-00860)SDR SWIA201025198Wire · brokenFORWARD MOST, RED FLOORSTRIP LIGHT DOES NOT ILLUMINATE. (FLT 7774) REWIRED FORWARD RED EMERGENCY LIGHT OF THE FLOOR TRACK LIGHTING STRIP.SDR DALA1032711201Wire · damagedEMERGENCY AISLE LIGHT L777 IS INOPERATIVE. MAINTENANCE FOUND WIRE W834603-18 HAS NO GROUND AND REPLACED THE WIRE. SYSTEM OPERATION IS NORMAL. (2010-D1372) (DL76L103203)SDR DALA1032416303Wire · disconnectedDURING A LINE CHECK, MAINTENANCE FOUND THE EMERGENCY PATH LIGHTS AT ROW 35 & 36 RIGHT INOPERATIVE. MAINTENANCE RECONNECTED THE WIRING. OPERATIONAL CHECK WAS GOOD. (2010-00857)SDR DALA1032701818Wire Harness · disconnectedEMERGENCY LIGHTS AT SEAT 20B ARE INOPERATIVE. MAINTENANCE FOUND THE HARNESS DISCONNECTED AT 19B AND RECONNECTED. SYSTEM OPERATION IS NORMAL. (2010-D1371) (DL764103202)SDR UALA2010111504220Wire · brokenCREW REST CEILING EMERGENCY LIGHT INOP. REPLACED BATTERY PACK AND REPAIR BROKEN WIRE IN LIGHT ASSY, OP CHECKS GOOD ON GROUND CHECKS.SDR DALA1032530980Wire · brokenDURING LINE CHECK MAINTENANCE FOUND EMERGENCY LIGHTS AT SEATS 1 THRU 13 AND FORWARD GALLEY RED LIGHT INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRING AT SEAT 13D. (2010-D1363) (DLM88103193)SDR UALA2010111504214Wire Harness · inoperativeSEAT MOUNTED FLOOR PROXIMITY EMERGENCY ESCAPE PATH MARKING LIGHTS ARE INOP SEATS 12ABC. REPLACED SEAT WIRE HARNESS AND LIGHT ASSY. OPS CK GOOD.SDR UALA2010111504213Wire Harness · damagedFLOOR PROXIMITY EMERGENCY ESCAPE PATH SEAT MOUNTED LIGHTS CABLE HAS A WIRE BROKEN. CABLE THATS FROM THE FLOOR TO THE SEATS. (SEATS 16ABC). REPLACED SEAT WIRE HARNESS, OPS CHECK GOOD.SDR DALA1032095645Connector · looseDURING LAYOVER CHECK FOUND SEAT-MOUNTED EMERGENCY ESCAPE PATH LIGHTS AT SEATS 19C AND 21C INOPERATIVE. SECURED LIGHT ASSEMBLY ELECTRICAL CONNECTOR. REF ADDL LOG PAGE 0286534. (2010-00854)SDR UALA2010111504212Connector · unsecureEMERGENCY LIGHT ALONG STAIRS TO UPPER DECK INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OPS CHECKED NORMAL.SDR SWIA201025207Wire · damagedMAIN CABIN DOOR EMERGENCY LIGHT INOPERATIVE. (FLT 6312) REPAIRED DAMAGED WIRES AT MCD EMERGENCY LIGHT.SDR DALA1032403250Wire · damagedDURING EMERGENCY LIGHT TEST, SEAT 9C PATH LIGHT WAS INOP. REPAIRED WIRING AND CHECKED OK. (2010-00855)SDR USAA2010111292596Wire · brokenFLT 751 - PHL-MIA - EMERGENCY LIGHTS - FLOOR EMERGENCY ESCAPE PATH AT ROW 10ABC INOPERATIVE. FOUND WIRE BROKEN AT CONNECTOR. REPLACED CONNECTOR & ATTACH NEW WIRE TO PLUG. OPERATIONAL CHECK WAS GOOD.SDR DALA1031266311Wire · openDURING A LINE CHECK, MAINTENANCE FOUND SEAT 9JK AREA EMERGENCY PATH LIGHTS INOPERATIVE. MAINTENANCE REPAIRED AN OPEN WIRE. OPERATIONAL CHECK WAS GOOD. (2010-00848)SDR USAA2010111292592Terminal · looseFLT 38-PHX - EEL - EMERGENCY LIGHT ASSEMBLY INOPERATIVE AT ROW 11. MAINTENANCE RECRIMPED TERMINAL. OPERATIONAL CHECK WAS GOOD.SDR SWIA201025175Wire · unsecureMIDDLE OVERHEAD EMERGENCY LIGHT INOPERATIVE. (FLT 6708) SECURED LOOSE WIRE AT OUTLET SOCKET FOR MIDDLE OVERHEAD EMERGENCY LIGHT.SDR USAA2010111192590Wire Harness · damagedFLT 325 - PHX-GDL - EMERGENCY LIGHTS - EMERGENCY EXIT LIGHT INOP AT ROW 16, LT SIDE. REMOVED AND REPLACED SEAT HARNESS EMERGENCY EXIT LIGHT ROW 16, LEFT SIDE. OPERATIONAL CHECK WAS GOOD. REFERENCE WDM 33-40.SDR AALA20101111GSW04Wire · unsecureSEAT MOUNTED ESCAPE PATH LIGHT AT 35D INOPERATIVE. RESECURED WIRE FROM CONNECTOR FOR 35D ESCAPE PATH LIGHT. OPS CHECKS NORMAL.SDR ZZDA2010573Connector · defectiveCEILING EMERGENCY LIGHT L2-742 DOES NOT ILLUMINATE. RE-TERMINATED CONNECTOR P1-6717/R5-6717 IAW SWPM 20-31-17. PERFORMED OPS CHECK OF EMERGENCY LIGHT SYSTEM IAW AMM 33-51-00, AND OPS CHECK NORMAL.SDR DALA1031290656Connector · damagedDURING LAYOVER CHECK, MAINTENANCE FOUND 4CD SEAT MOUNTED EMERGENCY PATH LIGHT INOPERATIVE. MAINTENANCE REPAIRED THE CONNECTOR. OPERATIONAL CHECK WAS GOOD. (2010-D1352) (DL757103075)SDR TRBA2010135Wire · disconnectedEMERGENCY LT IN CABIN DOOR STEPS INOP. RECONNECTED LAMP WIRE IAW SMP 20-45-00. OPS CK GOOD.SDR DALA1030883142Connector · looseDURING A NON-ROUTINE CHECK, THE EMERGENCY LIGHT SYS FAILED A EPSU LOAD TEST. MX FOUND A LOOSE CONNECTOR AT AFT LT SLIDE. RE-SEATED CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR USAA20101109SB185Wire · brokenDCA - MAINTENANCE REPORTED THE EMERGENCY ESCAPE PATH LIGHT AT SEAT ROW 20ABC INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE BENEATH SEAT. OPERATIONAL CHECK OF LIGHT GOOD. REFERENCE MM 33-51-12.SDR UALA2010110804139Connector · disconnectedEMERGENCY EXIT SIGN INOP: BELOW MONITOR AT DR4L. RECONNECTED CONNECTOR. CHECKS NORMAL.SDR UALA2010110804135Connector · unsecureWALL EMERGENCY LIGHT INOPERATIVE LT SIDE AFT GALLEY WALL. SECURED LOOSE CONNECTOR, CHECKS OK.SDR UALA2010110804133Connector · disconnectedWALL EEL INOP: UPPER DK STAIR WALL FWD SECTION. RECONNECTED CONNECTOR. CHECKS NORMAL.SDR UALA2010110804148Connector · unsecureEMERGENCY LIGHTS INOPERATIVE. REPLACED LIGHT ASSY. SECURED CONNECTOR AT 37C. RELAMPED 18G. CHECKED OKAY.SDR DALA1030803121Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 22C INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE. (2010-00842)SDR DALA1030829020Wire · damagedDURING MX CHECK, FOUND EMERGENCY LIGHTING IN CEILING ABOVE ROW 11 SEATS NON-OPERATIONAL. MX REWIRED LIGHTING. OPS OF LIGHTS CHECKS GOOD.SDR DALA1030791602Connector · not seatedTHE EMERGENCY LIGHTS AT ROW 22AB ARE INOPERATIVE. MAINTENANCE RE-SEATED A LOOSE CONNECTOR AND THE SYSTEM WAS OPERATIONAL AGAIN. (2010-D1338) (DL76G103061)SDR AALA20101107DFW03Wire Harness · inoperativeAFT EMERGENCY LIGHT AT SEAT 18DEF INOPERATIVE. REPLACED EMERGENCY LIGHT HARNESS AT SEAT ROW 18DEF. OPS CHECK NORMAL.SDR AALA20101105JFK01Connector · brokenFOUND ALL EMERGENCY EXIT LIGHTS INOPERATIVE ON LEFT SIDE FROM ROW 31 AFT. FOUND BROKEN CONNECTOR FOR EMERGENCY PATH LIGHTING BY SEATS 37 A AND B. REPLACED BROKEN CONNECTOR.SDR USAA2010110892540Cable · brokenPIT - C11 - EEL - ROW 10L EMERGENCY FLOOR LIGHT IS INOP. BROKEN WIRE AT FLOOR TO CABIN WALL AREA. REPLACED WALL TO SEAT CABLE ASSEMBLY IAW A321 AMM 33-51-19.SDR AALA20101107DFW07Connector · looseSEAT MOUNTED EMERGENCY LIGHTS AT 5EF INOPERATIVE. SECURED LOOSE CONNECTOR AT 5EF. OPS OK.SDR USAA2010110492502Wire · damagedFLT 347 - PHX - EEL - EMERGENCY EXIT LIGHT INOPERATIVE AT 1L (WIRE BROKEN UNDER SEAT 1C). MAINTENANCE REPAIRED WIRE IAW ELECTRICAL STANDARD PRACTICES MANUAL 20-48-25.SDR DALA1031281805Connector · looseEMERGENCY PATH LIGHTS AT 37A ARE INOPERATIVE. MAINTENANCE FOUND A CONNECTOR AT 37A LOOSE AND RECONNECTED. SYSTEM OPERATION IS NORMAL. (2010-D1349) (DL764103070)SDR SWAA106759Ground Wire · disconnectedDURING SCHEDULED SPV CHECK, FOUND L1 DOOR EMERGENCY EXIT LIGHT INOP. FOUND GROUND WIRE DISCONNECTED. CONNECTED WIRE PER SWPM.
Back to JASC 3397