JASC 3397
Service difficulty reports · 22,664
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA101026001Pcb · overheatedDURING PREPARATION FOR FLIGHT (AVIONIC 72 HRS, ELAPSED TIME INSP) MX CREW REPORTED INOPERATIVE EMERGENCY LIGHTS. INVESTIGATION REVEALED THAT THAT THERE WAS NO POWER OUTPUT FROM THE EMERGENCY BATTERY PACKS. BOTH UNITS WERE REMOVED FROM THE ACFT AND A STRONG BSDR USAA20101008BA058Wire Harness · defectivePHL - THE EMERGENCY LIGHT HARNESSES AT SEAT ROWS TWO AND FIVE ARE INOPERATIVE. REPLACED EMERGENCY LIGHT HARNESSES AT SEAT ROWS TWO AND FIVE.SDR AALA20101007DFW07Connector · loosePATHWAY EMERGENCY LIGHTS FROM SEAT 36 TO 45 ON BOTH SIDES ARE INOPERATIVE. RECONNECTED AND SECURED LOOSE CONNECTOR. OPS CHECKS NORMAL.SDR DALA1025656310Wire · brokenDURING A LINE CHECK, MX FOUND THE R1 DOOR EMERGENCY SLIDE LIGHT INOPERATIVE. MX REPLACED A BROKEN WIRE. OPS CHECK WAS GOOD.SDR EIAA2010065Pin · damagedUPPER DECK CEILING AFT EMERGENCY LIGHT INOP. REPAIRED CONNECTOR PIN 7 (DM335) GOING TO EMERGENCY POWER SUPPLY OP'S. CHECKED NORMAL PER MM 33-51-00 PAGE 501 REF WDM 33-51-12 PG 16.SDR DALA1025760911Wire Harness · inoperativeDURING LINE MX, FOUND EMERGENCY PATH LIGHT AT 30D INOPERATIVE. MX REPLACED LIGHT HARNESS AT 30D. OPERATION OF LIGHT NOW CHECKS OK.SDR UALA2010100403674Wire · shortedTHREE SERVICE EMERGENCY LIGHT TEST GIVES 2 FAULTS. EPSU INTERNAL AND EXTERNAL LIGHT FAULTS AT AFT L. FOUND WIRES PULLED AND SHORTED BELOW AFT ROW LT SEATS. RECONNECTED, TESTS OK.SDR DALA1025561605Contact · dirty2 EMERGENCY LIGHTS EXT RT, JUST AFT OF WING ARE INOPERATIVE. MX CLEANED BULB CONTACTS. SYS OPS IS NORMAL.SDR UALA2010100103639Cable · exposedFLOOR CABLE EXPOSED 30B. SECURED CABLE.SDR DALA1025490921Wire · damagedINSP DURING LINE CHECK MX, FOUND EMERGENCY LIGHTS AT ROW 13 INOPERATIVE. MX REPLACED LIGHT ASSY IAW MM 33-53-01 DUE TO PULLED WIRE. OPERATION OF LIGHT NOW CHECKS OK.SDR DALA1025153265Wire · damagedDURING A NON ROUTINE CHECK, MAINT FOUND ROW 10 ABC EMERGENCY PATH LIGHT INOPERATIVE. MAINT SPLICED IN NEW WIRES UNDER SEAT AND PERFORMED FUNCTIONAL CHECK. CHECK WAS NORMAL.SDR UALA2010093003618Connector · unsecureEMERGENCY EXIT LIGHT INOP, DOOR 4 GALLEY AREA, LOWER WALL. RESEATED CONNECTOR, CHECKS OK.SDR UALA2010100103636Connector · disconnectedSEAT 1A AFT EMERGENCY LIGHT INOP, REPLACED LIGHT ASSY, NO HELP. FOUND CONNECTOR INSIDE SEAT CONSOLE ASSY DISCONNECTED, RECONNECTED AND SECURED CONNECTOR. OP CHECK OF EEL LIGHT GOOD.SDR AALA20101003DFW07Splice · corrodedMID GALLEY LAVATORY MOUNTED EMERGENCY LIGHT ASSEMBLY INOPERATIVE. REPAIRED CORRODED SPLICE AT LAVATORY AFT WALL. OPS CHECKS GOOD.SDR UALA2010093003617Connector · unsecureEMERGENCY EXIT LIGHT INOP. LOWER WALL EMERGENCY EXIT LIGHT ACROSS DOOR 4 LT. RESEATED PLUG, CHECKS OK.SDR UALA2010093003616Connector · unsecureEMERGENCY EXIT LIGHTS INOP. SEAT ROWS 45 THRU 53 LT. RESEATED PLUG, CHECKS OK.SDR USAA20101001SB153Splice · pulledORD - MAINTENANCE REPORTED THE FLOOR LEVEL EMERGENCY LIGHT AT SEAT ROW 13, LEFT SIDE, INOPERATIVE. MAINTENANCE FOUND BUTT SPLICE PULLED APART FROM WIRING. INSTALLED NEW BUTT SPLICE IN ASSOCIATION WITH SWPM 20-30-12. OPERATIONAL CHECK GOOD.SDR C2XA10RI126Connector · looseFLIGHT 2201 - RIC - DURING ROUTINE INSPECTION, MX FOUND 12CD UPPER EMERGENCY SIGN INOPERATIVE. MX TIED LOOSE CONNECTOR AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR UHLA2010092900161Connector · unsecureAFT RT EXIT SIGN LIGHT INOPERATIVE. RE-SECURED CONNECTOR AT OVERHEAD PANEL. OPS CHECK GOOD IAW EMB 170 MM 33-50-01.SDR UALA2010092903601Connector · unsecureEMERGENCY EXIT LIGHTS INOP. UPPER DECK SEAT ROWS 13 THRU 14 LT. SECURED CONNECTION.SDR DALA1025111701Connector · damagedEMERGENCY LIGHTS AT SEAT 26G AND 33B ARE INOPERATIVE. MX RE-PINNED THE CONNECTOR AT LIGHTS. SYS OPS IS NORMAL.SDR AALA20100929MIA04Wire · damagedFORWARD GALLEY LEFT OUTBOARD CORNER EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRING FOR EMERGENCY LIGHT. OPS CHECKS NORMAL.SDR DALA1025091606Connector · looseEMERGENCY LIGHTS AT SEATS 32FG-34FG ARE INOPERATIVE. MX SECURED LOOSE CONNECTOR AT 34FG. SYS OPS IS NORMAL.SDR DALA1024919852Wire · chafedTHE PILOT REPORTED THAT AFTER ARRIVAL AT THE GATE AND FOLLOWING GROUND POWER CONNECTION, THE EMERGENCY PATHWAY LIGHTING CHARGING SYS CIRCUIT BREAKER POPPED AND WOULD NOT RESET. MX FOUND A WIRE CHAFING AT BATTERY PACK B5-40 AND REPAIRED IT. FUNCTIONAL CHECK OSDR DALA1024906316Connector · damagedDURING A LINE CHECK, MX FOUND 4 EMERGENCY PATH LIGHTS AT SEAT 80 INOPERATIVE. MX REPAIRED THE WIRING CONNECTION. OPS CHECK WAS GOOD.SDR MASA2010093001054Connector · damagedEMERGENCY FLOOR LIGHTS AFT OF ROW 8 INOP. MX RE-SPLICED CONNECTOR P40LY, OPS NORMAL.SDR DALA1024840613Wire · damagedDURING A SERVICE CHECK, MX FOUND THE LT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. MX REPAIRED THE WIRING. OPS CHECK WAS GOOD.SDR UALA2010092803585Wire · miswiredEMERGENCY LIGHT SWITCH AT THE AFT F/A PANEL DOES NOT WORK WHEN EMERGENCY SWITCH IN THE FLIGHT DECK IS IN THE ARM MODE. REMOVED CONN D1650 AT AFT F/A PANEL, (WITH FL DK SW IN ARM) FOUND PINS 24 AND 25 HAVE NO CONTINUITY WHEN EMER LIGHT SW ACTIVATED. FOUND "EMERSDR AALA20100929TUL01Connector · defectiveFORWARD EMERGENCY LIGHT ON 11D INOPERATIVE. REPLACED PLUG ON EMERGENCY LIGHT AT 11D. OPS CHECK NORMAL.SDR AALA20100929DFW01Connector · looseAFT EMERGENCY LIGHT ON 1D INOPERATIVE. SECURED PLUG ON AFT EMERGENCY LIGHT AT 1D. OPS CHECKED NORMAL.SDR DALA1024809013Connector · brokenDURING LINE CHECK, MX FOUND EMERGENCY PATH LIGHT AT 11D & 13D INOPERATIVE. MX REPAIRED BROKEN CONNECTORS. OPS OF LIGHTS NOW CHECKS OK.SDR MASA2010092901040Wire · pulledRT OVERWING EMER EXIT LIGHT INOP. MX FOUND WIRES PULLED OUT OF THE LIGHT ASSY. MX RE-PINNED GROUND WIRE AND RELAMPED.SDR UALA2010092703565Wire · shortedDOME LIGHT WOULD NOT ILLUMINATE USING DOME LIGTH SWITCH OR WITH LIGHT OVERHEAD SWITCH ON. DOME LIGHT 3 LIGHTS BLOWS WHEN SWITCH IS TURNED ON LIGHT SHORTED NEED TO GET BEHIND LIGHT COVER ON SCREW STRIPPED NEED MORE TIME TO FIND SHORT. MECHANIC REPORTS THAT EMERSDR DALA1024799012Wire · damagedDURING SERVICE CHECK MX FOUND EMERGENCY LIGHTS AT ROW 23 INOPERATIVE. MX REPLACED FIXTURE AND PIGTAIL. OPS OF LIGHTS NOW CHECKS OK.SDR UALA2010092703570Wire · disconnectedAT SEAT 1H, SEAT MOUNTED EMERGENCY STRIP INOPERATIVE. WIRES HAVE PULLED OUT OF THE CONNECTOR FOR THIS AFT EMERGENCY LIGHT. REPLACED EMERGENCY LIGHT ASSY AT 1H.SDR DALA1024780920Wire · brokenDURING LINE CHECK MX FOUND EMERGENCY LIGHTS AT ROW 2DE INOPERATIVE. MX REPAIRED BROKEN WIRE AT ROW 25DE IAW SWPM CHAP 20. OPS OF LIGHTS NOW CHECKS OK.SDR DALA1024481201Connector · damagedEMERGENCY LIGHTS AT 32-41FG ARE INOPERATIVE. MX REPLACED THE CHARGER AND REPAIRED A PIN PULLED FROM THE CONNECTOR. SYS OPS IS NORMAL.SDR UALA2010092703553Connector · unsecureEMERGENCY LIGHT ALONG LAV BETWEEN L3 DOOR AND R3 DOOR INOP. RESECURED LAMP CONNECTOR. OPS CHECKED NORMAL.SDR DALA1024470194Wire · brokenMX FOUND EMERGENCY PATH LIGHTS BROKEN WIRE AT 3AB AND SECURE WIRE AND PIN PLUGS. SYS OPS IS NORMAL.SDR UALA2010092703552Feeder Cable · inoperativeEMERGENCY LIGHT 3R LAV SIDEWALL INOPERATIVE. REPLACED EMERGENCY LIGHT CABLE. OPS CK NORMAL.SDR JJBA201033978Wire · chafedMAIN CABIN DOOR LOWER EXIT SIGN WILL NOT ILLUMINATE. FOUND WIRE 3351-28A20 CHAFED. SPLICED IN NEW WIRE AND REPOSITIONED TO PREVENT FURTHER CHAFING.SDR DALA1023833751Wire Harness · disconnectedTHE EMERGENCY EGRESS LIGHTING WAS FOUND TO BE INOPERATIVE AT ROW 25DEF. MX RECONNECTED THE WIRE HARNESS AT THE SIDEWALL AND SYS RETURNED TO NORMAL.SDR UALA2010092203533Connector · unsecureEMERGENCY EXIT LIGHT INOP. BELOW VIDEO COMPARTMENT LOWER WALL. SECURED CONNECTOR. OPS CHECKS NORMAL.SDR SIMA201026604Splice · disconnectedDURING MAINTENANCE BASE VISIT FOUND THE EMERGENCY LIGHT ON THE SERVICE DOOR FRAME TO BE INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. WHIILE TROUBLESHOOTING A WIRE SPLICE WAS FOUND TO BE DISCONNECTED. RECONNECTED THE SPLICE AND PERFOMRED AN OPERATIONALSDR UALA2010092203527Connector · damagedEMERGENCY ESCAPE PATH LIGHT INOP SEATS 43ABC. DEFERRED EMERGENCY ESCAPE PATH LIGHT SEATS 43 ABC IAW MEL. REPAIRED PUSHED PIN. OPS CHECKS GOOD.SDR UALA2010092203526Wire · faultyEMERGENCY EXIT LIGHTS ON SEATS FROM 43ABC TO 53ABC INOP. TROUBLESHOT EMERGENCY SYS AFTER INSULATED WIRING BETWEEN SEAT ROW 45ABC TO NEXT SEAT ROW 43ABC. EMERGENCY ESCAPE PATH LIGHT OPS CHKS NORMAL & AROUND DOOR 4L AND FROM SEAT ROW 45ABC TO 53ABC.SDR DALA1023849001Connector · disconnectedDURING LINE CHECK, MX FOUND THE EMERGENCY PATH LIGHTS AT SEATS 3 AND 19 TO BE INOPERATIVE. MX RECONNECTED A CONNECTOR AT SEAT 3 AND RE-LAMPED THE LIGHTS AT SEAT 19. OPS CHECK OF LIGHTS IS NOW GOOD.SDR MASA2010092101012Wire Harness · defectiveAFT EMERGENCY FLOOR LIGHTS INOP. MX REPLACED FLOOR STRIP WIRE HARNESS CABLE.SDR USAA2010092192056Wire · disconnectedFLT 2171 - LGA-DCA - EMERGENCY LIGHTS - EMERGENCY FLOOR LIGHT ASSEMBLY BELOW SEAT 4C INOPERATIVE. RE-ATTACHED WIRING. OPERATIONAL CHECK WAS GOOD.SDR USAA2010092192055Wire Harness · unserviceableFLT 458 - SLC-PHX - EMERGENCY LIGHTS - EMERGENCY LIGHT ROW 1L INOPERATIVE. INSTALLED NEW HARNESS 5409VB FROM SIDE WALL DISCONNECT TO SEAT BOX DISCONNECT LOCATION PER AWM 33-51-06. OPERATIONAL CHECK WAS GOOD.
Back to JASC 3397