Service difficulty report · Pcb · Bombdr BD1001A10

Difficulty date
October 5, 2010
Submitted
March 15, 2011
Operation
Air carrier
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Pcb
Condition
Overheated
Location
Emergency Lights
Component
Emergency Light · Bruce
Component part number
BR9767001
Stage of operation
IN
How discovered
9
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING PREPARATION FOR FLIGHT (AVIONIC 72 HRS, ELAPSED TIME INSP) MX CREW REPORTED INOPERATIVE EMERGENCY LIGHTS. INVESTIGATION REVEALED THAT THAT THERE WAS NO POWER OUTPUT FROM THE EMERGENCY BATTERY PACKS. BOTH UNITS WERE REMOVED FROM THE ACFT AND A STRONG BURNED SMELL WAS NOTICED WHILE HANDLING THEM. ACCESS COVERS OF THE BATTERY PACKS WERE OPENED, AND THE CONDITION OBSERVED IS THE RESISTOR (R1 3 OHMS 6.5 WATTS) OVERHEATED AND BURNED THE CLEAR COATING ON BOTH PC BOARD. RNC WAS RAISED REF C310077030 AT THE ISSUE OF THIS DISCREPANCY, A LINE CHECK IS ACTUALLY IN PROGRESS TO PREVENT FURTHER ISSUES. SUPPLIER COMPLIANCE IS ACTUALLY PERFORMING AN INVESTIGATION WITH SUPPLIER OF BATTERY PACK AND A COPY OF ATP & FTP ALONG WITH INSTALLATION WORK INSTRUCTIONS WILL BE PROVIDED FOR ADDITIONAL HISTORY OF EVENT.