JASC 3397
Service difficulty reports · 22,670
Reports filed under 3397 · Light System Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3397' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA20070466Connector · looseMIA - EMERGENCY LIGHT AT SEAT 24G INOPERATIVE. FOUND PIN PUSHED BACK ON CONNECTOR. SECURED PIN ON CONNECTOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070467Connector · looseMIA - FOUND EMERGENCY LIGHT AT SEAT 28G INOPERATIVE. FOUND PIN ON CONNECTOR PUSHED BACK. SECURED CONNECTOR FOR EMERGENCY LIGHT AT SEAT 28G. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR NOCA05707Wire · brokenRED E-PATH LIGHT INOP 26AB - 26GH. REPINNED BROKEN WIRE AS PER MM 33-51-00.SDR SWIA200717983Wire · failedFOUND ROW 8 AND AFT EMERGENCY FLOOR LIGHTING STRIP OUT. REPLACED POWER STRIP ON EMERGENCY LIGHT FLOOR STRIP ROW 8 AND BACK IAW CRJ AMM 33-51-01. OPERATIONAL CHECKS GOOD.SDR AALA20070655Wire Harness · disconnectedTUL - EMERGENCY LIGHTS AT SEAT ROW 28DEF INOPERATIVE. REPINNED WIRES AT SIDEWALL AND INSTALLED IN CONNECTOR FOR EMERGENCY LIGHTS AT SEAT ROW 28DEF. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR RAIA00703021Connector · unsecurePRE FLT NR 8022 - STL - LEFT EMERGENCY OVERWING EXIT MARKER LIGHT INOP. MAINTENANCE RESCURED LEFT EMERGENCY LIGHT CONNECTOR, OPS CHECK GOOD.SDR MASA200700142Wire · brokenASH 2843 PHX. EMERGENCY EXIT FLOODLIGHT NEAR PAX DOOR INOP. MX FOUND BROKEN WIRE ON BACK OF SIGN AND REPAIRED WIRE.SDR 2007UALA00695Connector · unsecureEEL AT 4E & 4F ARE INOPERATIVE. SECURED LOOSE FEEDER CONNECTOR. EEL OP CHECKED OK.SDR BB07020Wire · disconnectedEMERGENCY LIGHTS INOPERATIVE FORWARD OF SEAT 12F. MAINTENANCE RECONNECTED WIRING. NO FURTHER FAULTS.SDR C2XA07BT027Connector · disconnectedBTV ROUTINE CHECK FLT NR 2043 FOUND SERVICE DOOR EMERGENCY LIGHT(EXTERIOR) INOP. RECONNECTED SERVICE DOOR EMERGENCY LIGHT CONNECTER IAW EMB145 AMM STANDARD PRACTICES. OPS CHECK GOOD. CLOSEDSDR 2007UALA00668Feeder Cable · cutEEL LIGHT CABLE CUT AT SEATS 4A & 5E. REPLACED WITH NEW EMER LIGHT SEGMENTS (2 POSITIONS). EEL SYSTEM CHECKED NORMALLY.SDR AALA20070436Wire Harness · inoperativeLAX - EMERGENCY LIGHT AT SEAT 4B INOPERATIVE. REPAIRED WIRE CONNECTION FOR EMERGENCY LIGHT AT SEAT 4B. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR C2XA07BT024Connector · dirtyEWR LOG SQUAWK FLT 2347 FORWARD OVERHEAD EMERGENCY EXIT LOCATER SIGN AT ROW 11 OUT. CLEANED CONNECTOR AND RESECURED FORWARD EMERGENCY EXIT LOCATER AT ROW 11 IAW EMB145 AMM 33-50-13. OPS CHECK GOOD. CLOSEDSDR COMA0760224Jumper · failedFLIGHT 9420 - EMERGENCY LIGHTS NEAR PAX AND SERVICE DOORS INOPERATIVE. REMOVED AND REPLACED JUMPER CABLE.SDR MALA070033Connector · brokenFOUND EMERGENCY FLOOR TRACK LIGHTING DISCOVERED INSECURE AT THE 1A/2A AREA. UPON INSPECTION, FOUND CONNECTORS BROKEN. REPLACED EMERGENCY FLOOR TRACK LIGHTING STRIP AT ROW 2A-3A WITH SERVICEABLE UNIT, P/N 6636-2 IAW SF340MM 33-50-20.SDR SA07020Pin · bentDCA - THE TEST OF THE EMERGENCY EXIT LIGHT SYSTEM FAILED, FAULTING EPSU EXT LOAD L ON THE FORWARD CIDS PANEL. MAINTENANCE REPLACED THE AFT LEFT EMERGENCY POWER SUPPLY BATTERY, WHICH DID NOT FIX THE PROBLEM. THE AIRCRAFT WAS RELEASED ON MEL. SUBSEQUENTLY, MASDR AALA20070417Pin · looseDFW - EMERGENCY LIGHTS AT SEAT 17B INOPERATIVE. RESEATED WALL TO SEAT CONNECTOR PIN AT SEAT 17B FOR INOPERATIVE EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA00655Contact · out of alignmentEMERGENCY SLIDE LIGHT INOP AT DOOR 1R. [SUP 4-17-07] FOUND CENTER CONTACT POPPED OUT OF LIGHT ASSEMBLY. REINSTALLED CENTER CONTACT OPS NORMAL.SDR 2007UALA00634Wire · faultyA-ZONE FLOOR EEL INOP FROM SEAT 3 TO SEAT 6. REPAIRED CABLE. OPS CHECKED GOOD.SDR BB07019Wire · damagedMAINTENANCE FOUND FLOOR LEVEL EMERGENCY LIGHTS BETWEEN ROWS 3 AND 5 RIGHT INOPERATIVE. REPAIRED WIRING. NO FURTHER FAULTS.SDR BB070019Wire · damagedMAINTENANCE FOUND FLOOR LEVEL EMERGENCY LIGHTING INOPERATIVE BETWEEN ROWS 3 AND 5 RIGHT. ACCOMPLISHED REPAIR TO WIRING. NO FURTHER FAULTS.SDR SWIA200717868Connector · looseFOUND FLOOR LEVEL EMERGENCY LIGHTS AFT OF ROW 8 ARE INOP. SECURED CONNECTOR AT ROW 12. OPERATIONAL CHECKS GOOD..SDR 2007UALA00635Feeder Cable · damagedEEL FEEDER AT ROW 28 DAMAGED. REPLACED EEL LEAD IN AND OPS CHECK GOOD.SDR SWIA200717980Wire · brokenFOUND EMERGENCY EXIT ROW LIGHT/SIGN ON 9B OVERHEAD BIN WILL NOT ILLUMINATE. REPAIRED WIRE ON EMERGENCY EXIT LIGHT AT ROW 9B/C OVERHEAD BIN. OPERATIONAL CHECKS GOOD.SDR HALA0700073Connector · looseFOUND EMERGENCY FLOOR LIGHTS FROM MID GALLEY AFT TO OVERWING EXIT ACFT LEFT INOP. RETERMINATED LOOSE CONNECTOR AT OVERWING EXIT. LIGHTS OPERATE NORMAL.SDR HALA0700072Connector · unknownFOUND FWD GALLEY X-OVER AISLE FLOOR PROX LIGHTS INOP. REPLACED CONNECTOR STRIP OPN CK GOOD.SDR SB07020Wire · brokenDCA - MAINTENANCE FOUND THE FLOOR PROXIMITY EMERGENCY LIGHTS AT THE LAST TWO ROWS OF SEATS, LEFT-HAND SIDE, INOPERATIVE. MAINTENANCE REPAIRED WIRING. OPERATIONAL CHECK OF EMERGENCY LIGHTS GOOD.SDR 2007UALA00609Connector · looseEMERGENCY EXIT LIGHT AT ROW 13 INOPERATIVE. [SUP 4-17-07] TROUBLESHOT AND FOUND CONNECTOR D07274 LOOSE, RECONNECTED AND PERFORMED OPS CHECK GOOD.SDR 2007UALA00602Wire Harness · damagedEMERGENCY LIGHT ROW 2J INOPERATIVE. REPLACED EEL SEAT HARNESS AT ROW 2J, OP CHECKS OK.SDR RAIA00702046Wire · loosePRE FLT NR 3507 - PIT - FLOOR EMERGENCY PROXIMITY LIGHTS INOP. MAINTENANCE RESECURED WIRE TO FLOOR PROX STRIP. OPS CHECKS GOOD.SDR ABXA070053Wire · out of positionDOOR 1 LEFT EMERGENCY EXIT SIGN INOPERATIVE. FOUND WIRE M748-033-14, MIS-PINNED IN PIN 13 OF CONNECTOR D1084, REPOSITIONED TO PIN 9 OF CONNECTOR D1084. OPS CHECKED GOOD IAW B767 MM 33-51-00-715-801.SDR AALA20070406Connector · damagedMIA - EMERGENCY LIGHT AT SEAT 20H BULKHEAD FORWARD OF SEAT INOPERATIVE. FOUND PIN PUSHED BACK. RESECURED PIN TO CONNECTOR FOR E EMERGENCY LIGHT AT SEAT 20H BULKHEAD FORWARD OF SEAT. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR RAIA00702043Wire · brokenPOST FLT NR 5564 - STL - EMERGENCY ROW EXIT LIGHTS NOT WORKING AT 1A & 2A. MAINTENANCE REPAIRED WIRE ON LIGHT TRACK AT 1A AND 2A. LIGHTS CHECK OK.SDR AALA20070405Connector · looseMIA - FOUND EMERGENCY LIGHT AT SEAT 29G INOPERATIVE. SECURED LOOSE CONNECTOR UNDER SEAT FOR EMERGENCY LINGT AT SEAT 29G. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070404Wire Harness · inoperativeLGA - FOUND EMERGENCY LIGHTS IN AFT STAIRWAY INOPERATIVE. REPLACED SPLICE ON HARNESS FOR EMERGENCY LIGHTS IN AFT STAIRWAY. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR RAIA00702039Connector · dirtyPRE FLT NR 8046 - IAD - FWD EMERGENCY LIGHT STRIP FLOOR PROXIMITY LIGHT INOP. MAINTENANCE CLEANED CONNECTOR ON FWD STRIP.SDR 070051Connector · looseDURING A ROUTINE OVERNIGHT MAINTENANCE SERVICE CHECK LAS VEGAS MAINTENANCE REPORTED THAT THE ELECTROLUMINESCENT EGRESS PATH LIGHTING WOULD NOT TEST BETWEEN ROWS 21 AND 24. FURTHER REPORT THAT TIGHTENED THE ELECTROLUMINESCENT STRIP ELECTRICAL CONNECTION. A SASDR CALA0700087Connector · disconnectedLIGHT ASSY CONNECTOR DISCONNECTED. EMERGENCY LIGHT INOP AT 18D. RECONNECTED AND PER MM 33-51-10.SDR 2007UALA00592Wire · faultyEMERGENCY ESCAPE PATH LIGHTING INOP AT SEAT ROW LOCATIONS 6 & 7, 10, 13 & 14, 17 & 18 AND 21 & 22. [5-1-07] REPLACED WIRE TERMINATION OF WIRE HARNESS 350WL4 IN REF WITH ASM 33-51-00 PG103. ESCAPE PATH LIGHTING OPS CHECKED NORMAL.SDR HALA0700063Wire · explodedFOUND MID GALLEY FLOOR LIGHTS HAS WIRE EXPOSED. REPLACED MID GALLEY EMERGENCY LIGHT TRACK COVER. OPS CHECK OK.SDR RAIA00703063Connector · loosePRE FLT NR 5578 - TUL - EMERGENCY LIGHT AT AFT SIDE AFT CEILING EXIT LOCATOR OUT. MAINTENANCE RESECURED CONNECTOR ON EMERGENCY LIGHT. CHECK GOOD.SDR AALA20070391Connector · looseLGA - FOUND EMERGENCY LIGHT AT OVERWING INOPERATIVE. RESEATED CONNECTOR ON POWER SUPPLY FOR EMERGENCY LIGHT AT OVERWING. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070394Connector · brokenDFW - EMERGENCY LIGHT AT SEAT 23D INOPERATIVE. REPLACED BROKEN CONNECTOR AT SIDEWALL FOR EMERGENCY LIGHT AT SEAT 23D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070398Fuse · failedDFW - EMERGENCY EXIT LIGHT AT LEFT NUMBER THREE DOOR INOPERATIVE. REPLACED FUSE IN EMERGENCY PATTERY PACK M33406 FOR EMERGENCY EXIT LIGHT AT LEFT NUMBER THREE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20070393Connector · looseDFW - EMERGENCY LIGHT AT SEAT 26D INOPERATIVE. RESECURED LOOSE CONNECTION AT SIDEWALL FOR EMERGENCY LIGHT AT SEAT 26D. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR RAIA00702037Connector · loosePRE FLT NR 5498 - STL - EMERGENCY LIGHT AT AISLE 1A AND LOWER EXIT ON SERVICE DOOR INOP. MAINTENANCE RESEATED CONNECTOR TO LIGHT FLOOR PROXIMITY LIGHT.SDR SWIA200717840Connector · disconnectedFOUND EMERGENCY EXIT SIGN AT FLOOR AND MAIN CABIN DOOR DOES NOT ILLUMINATE. SECURED CONNECTOR TO EMERGENCY EXIT AND PAX ENTRY FLOOR SIGN. OPERATIONAL CHECKS GOOD.SDR AALA20070384Connector · looseDFW - FOUND EMERGENCY LIGHT AT SEAT ROW 12 INOPERATIVE. RECONNECTED CONNECTOR FOR EMERGENCY LIGHT AT SEAT ROW 12. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA00564Feeder Cable · inoperativeFOUND EEL STRIP INOP AT AFT GALLEY CART STOWAGE. REPAIRED POWER FEEDER.SDR RAIA00702034Wire · brokenPRE FLT NR 5471 - STL - EMERGENCY LIGHT IS OUT AT ROW 12 FLOOR PROXIMITY LIGHTS. MAINTENANCE REPAIRED BROKEN WIRE TO FLOOR STRIP.
Back to JASC 3397