What was found
FOUND EMERGENCY FLOOR TRACK LIGHTING DISCOVERED INSECURE AT THE 1A/2A AREA. UPON INSPECTION, FOUND CONNECTORS BROKEN. REPLACED EMERGENCY FLOOR TRACK LIGHTING STRIP AT ROW 2A-3A WITH SERVICEABLE UNIT, P/N 6636-2 IAW SF340MM 33-50-20.