SDR AALA2020010769011Connector · looseAIRCRAFT WAS GROUNDED: L2 DOOR EPAS BATTERY GREEN LIGHT INOPERABLE. MAINTENANCE TROUBLESHOT AND FOUND CONNECTOR TO BATTERY LOOSE. MAINTENANCE SECURED CONNECTOR AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 52-11-20.SDR DALA2020010700107Wire · broken(AIRCRAFT 685, L/P 6706529) FOUND CEILING MOUNTED EMERGENCY LIGHT INOP AT ROW 15. CORRECTIVE ACTION: FOUND BROKEN WIRE IN ACFT HARNESS. REPAIRED PER B757 WDM 33-51-12 SH 2.SDR SWAA2020012740756Connector · damagedWHILE ACCESSING THE AFT LAVATORY, FOUND THE LOWER EMERGENCY EXIT LIGHT CONNECTOR DAMAGED. REPLACED THE AFT LAV LOWER EMERGENCY EXIT LIGHT ASSEMBLY WITH NEW ASSEMBLY IAW SOPM 20-50-01, STEP 3. PERFORMED AN OPS CHECK, OPS CHECKED GOOD IAW AMM 33-51-00-710-80SDR SIMA202001063003Connector · brokenMOST AFT PROXIMITY FLOOR LIGHT STRIP ELECTRICAL CONNECTOR BROKE OFF WIRING ON A/C SIDE.-C/A-INSTALLED NEW CONNECTOR IAW SWPM 20-50-01, COMPLIED WITH OPS CHECK IAW AMM 33-50-12 OPS CHECK GOOD.SDR AALA202001039012Connector · contaminatedAIRCRAFT IN BASE VISIT: L2, R2 AND BELLY FAIRING LEFT EXTERNAL EMER SLIDE LIGHT ARE INOPERATIVE. CLEANED CONNECTORS AND RE-LAMPED L2, R2 AND LEFT BELLY FAIRING SLIDE LIGHTS IAW AMM 33-51-04.SDR DALA2020010600070Pin · backed out(AIRCRAFT 692, L/P 6359197) ROW 26 SEAT MOUNTED EMER LIGHT INOP. CORRECTIVE ACTION: FOUND PUSHED BACK PIN ON LIGHT ASSY CONNECTOR. RESEATED PER B757 WDM 33-51.SDR AALA2020010329010Wire Harness · brokenAIRCRAFT WAS GROUNDED: ROW 21 RIGHT EMERGENCY FLOOR LIGHT ON SEAT INOPERABLE. MAINTENANCE FOUND EMERGENCY LIGHT AT ROW 21 RIGHT HARNESS WIRE BROKEN AND REPLACED HARNESS PER AMM 33-51-18.SDR AALA2020010219031Cable · disconnectedAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT INOPERABLE AT ROW 7. MAINTENANCE RECONNECTED CABLE AT ROW 7 AND PERFORMED SATISFACTORY CHECK PER AMM 33-51-00.SDR MASA201912312211Connector · looseEMERGENCY EXIT SIGN 4DF W/N ILLUMINATE. SECURED CONNECTOR.SDR VNAA2019123091101Wire · disconnectedEXIT SIGN EMERGENCY LIGHT BY PAX DOOR INOP. FOUND WIRE UNPLUGGED. CONNECTED THE WIRE IAW AMM 33-51-10-400-801. OPS CHECK GOOD.SDR DALA2019123007601Wire · disconnectedSEAT EMERGENCY LIGHT AT 19AB INOPERATIVE. TERMINATED THE WIRES AT SEAT 20AB.SDR AALA2019123099009Connector · unsecureAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS SEAT 25ABC EMERGENCY PATH LIGHTING INOP. RE-SECURED ELECTRICAL CONNECTOR ON SEAT EMERGENCY MOUNTED LIGHT AT ROW 25 ABC. OPS CHECK GOOD.SDR SWAA2019123140072Wire · missingFORWARD LAV LOWER EMERGENCY LIGHT WIRE MISSING. REPAIRED THE SIGN IAW WDM.SDR AALA201912279005Connector · disconnectedAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS SEAT ROW (EXIT) 24 EMERGENCY ESCAPE PATH LIGHT OUT. WHILE TROUBLESHOOTING FOUND CANNON PLUG BY WALL HAD BEEN KNOCKED OUT. RECONNECTED AND PERFORMED OPERATIONAL TEST OF THE EMERGENCY LIGHTING IN THE CABIN WITH THE LIGHSDR AALA201912279006Connector · abnormalAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS SEAT ROW 25 EMERGENCY ESCAPE PATH LIGHT OUT. WHILE TROUBLESHOOTING FOUND CANNON PLUG BY WALL HAD BEEN KNOCKED OUT. RECONNECTED AND PERFORMED OPERATIONAL TEST OF THE EMERGENCY LIGHTING IN THE CABIN WITH THE LIGHTS EMERSDR DALA2020010407676Connector · unsecureAFT GALLEY EMERGENCY PATH LIGHTS ARE INOPERATIVE. RE-SECURED CANNON PLUG AT BATTERY PACK M1210. SYSTEM OPERATION IS NORMAL.SDR DALA2019122647558Connector · disconnectedROWS 33-37 AISLE EMERGENCY LIGHTS INOPERATIVE . REMOVED AND REPLACED THE FUSE ON THE AFT RT BATTERY BOX ABOVE AFT GALLEY AND RECONNECTED CONNECTOR ON ROW 37 OPS CHECKED GOOD IAW AMM 33-51.SDR SWAA2019122639934Connector · dirtyR1 DOORS EMERGENCY EXIT SIGN INOP. / CLEANED CONNECTOR AT BATTERY PACK M1674 PER AMM.SDR SWAA2019122639917Connector · dirtyL1 DOORS EMERGENCY EXIT SIGN INOP. CLEANED CONNECTOR AT BATTERY PACK M1674 PER AMM.SDR MASA2019122212196Wire · brokenEMERGENCY LIGHT AT 4 DF INOPERATIVE. REPINED A BROKEN WIRE ON CONNECTOR P6014.SDR DALA2019122307501Wire · cutDURING INSPECTION, FOUND SEAT 17D BOTH RED EMERGENCY LIGHTS INOPERATIVE. INSPECTED WIRING UNDER SEAT, FOUND A CUT WIRE. SPLICED THE WIRE IAW SWPM 20-10. OPS CHECKED GOOD.SDR SIMA201912231001Wire · damagedMAIN DOOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED MAIN DOOR EXTERNAL EMERGENCY LIGHT IAW EMB140 AMM 33-50-10. REPAIRED WIRE W717-0003-20 IAW EMB140 SWPM 20-21-00. OPC GOOD.SDR SIMA2020021122006Wire · broken1EA PROX LIGHT WITH OUT ARROWS HAVE BROKEN WIRES-C/A-COMPLETE:REMOVED AND REPLACED 1EA PROX LIGHT WITHOUT ARROWS IAW EMB 145 AMM 33-50-12. OPS CHECK GOOD.SDR SIMA2020021122007Connector · disconnectedOVERWING CABIN CEILING PANEL FWD EMERGENCY EXIT SIGN DOES NOT ILLUMINATE-C/A-COMPLETE:CONNECTED CABIN OVERWING CEILING PANEL FWD EMERGENCY LIGHT AS REQUIRED IAW EMB 145 AMM 33-50-15 AND WM 33-50-50. OPS CHECK GOODSDR SIMA2020021122008Wire · brokenLH NO. 3 EMERGENCY LIGHT STRIP DOES NOT ILLUMINATE-C/A-COMPLETE:SPLICED BROKEN WIRE W192-8679-22 AT LH FR 32/33 IAW EMB 145 SWPM 20-21-00, WM 33-50-50, AMM 33-50-00. OPS CHECK GOOD EASI # 7249SDR DALA201912237496Circuit Card · malfunctionedEMERGENCY CABIN LIGHT "UNARMED" LIGHT DOES NOT COME ON WITH EMERGENCY LIGHTS SELECTED OFF. R&R UNARMED PB,S CIRCUIT PIECE P/N 434-093-001.SDR CALA2019122102257Wire · detachedELEC BURNING SMELL AND SUBSEQUENT SHOWER OF SPARKS FROM CAPTAINS LEFT GLARESHIELD FOUND LOOSE WIRE ON BACK OF RHEOSTAT(507) . NEED RHEOSTAT PART #86A2EZ8BA0689 FAULT CONFIRMED, LOOSE WIRE. REMOVED AND REPLACED RHEOSTAT SWITCH. SECURED ALL WIRES AND OPS CHECK GSDR MASA2019122092190Pin · looseRH EMERGENCY EXIT SIGN ROW 3 INOP
FOUND CANNON PLUG PIN LOOSE RESECURED PINSDR SWAA2020012740758Connector · missingLEFT SIDEWALL PANEL 231YHW EMERGENCY EXIT LIGHT MISSING A CONNECTOR. REPLACED THE EMERGENCY EXIT LIGHT IAW SRM 51-40-02-0G, STEP 9 (A-C).SDR AALA2019122099004Connector · faultyAIRCRAFT WAS NOT GROUNDED: EMERGENCY ESCAPE PATH LIGHT INOPERABLE ON LEFT HAND SIDE ROW 34. MAINTENANCE REPLACED CANNON PLUG PER ESPM 20-48-29 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DALA2019121877408Connector · damagedSEAT 16B EMERGENCY PATH LIGHT INOPERATIVE. FOUND GROUND PAN AT WALL SIDE OF SEAT HARNESS WILL NOT STAY SEATED. REPLACED SEAT HARNESS CONNECTOR AND PINS. LP6582479SDR AALA2019121869025Connector · not seatedAIRCRAFT WAS NOT GROUNDED: PATH EMERGENCY LIGHTS AT SEAT 4E DID NOT WORK. MAINTENANCE RESEATED CONNECTION AT SEAT 4E AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-00.SDR DALA2019121657331Pcb · malfunctionedAIRCRAFT RIGHT EMERGENCY FLOOR LIGHTS AND EXIT LIGHTS FROM DOOR @R TO 4R WILL NOT TURN OFF. REPLACED PCB-SPDB6. LP 1403604SDR DALA2019121607330Connector · damagedSEAT 23HJ AND 24HJ EMERGENCY PATH LIGHT INOPERATIVE. RE-INSERTED PIN IN PLUG TO WALL AT ROW 23. LP 6702156SDR DALA2019121607310Wire · brokenEMERGENCY AISLE LIGHTS ROW 24-27 INOP. REPAIRED BROKEN WIRE SPLICE PER BOEING SWPM CH 20 AND MD88 WDM 33-51. OPS CHECK NORMAL. OK FOR SERVICE. (LP6658774)SDR DALA2019121747395Wire Harness · damagedEMERGENCY LIGHT AT 36ABC INOP, FOUND OPEN AT FLOOR HARNESS, RETERMINATED WH5NVR1SDR AALA2019121769023Connector · looseAIRCRAFT WAS NOT GROUNDED: RIGHT HAND AFT EMERGENCY DOOR OVERWING LIGHT INOPERABLE. MAINTENANCE FOUND CONNECTOR LOOSE AT POWER PACK AND RECONNECTED CONNECTOR PER WDM 33-51-13 AND PERFORMED SATISACTORY OPERATIONAL CHECK.SDR JJBA201912164002Terminal · looseSERVICE DOOR EXTERNAL EMERGENCY LIGHT FLICKERS. R&R BROKEN SERVICE DOOR BONDING JUMPER AND RESECURED GROUND TERMINAL OF THE SERVICE DOOR EMERGENCY LIGHT LAMP. OPS CHECK SAT, FLICKERING STOPPED.SDR SWAA2019121839818Connector · damagedG1 GALLEY, AIRCRAFT SIDE ELECTRICAL CONNECTOR FOR EMERGENCY EXIT LIGHT DAMAGED. / R&R EXIT INDICATOR LIGHT PER AMM, WDM, & SWPM.SDR CALA2019121602209Wire · exposedEMERGENCY EXIT LIGHT MISSING SEAT 1D EXPOSED WIRE NEED TIME. EMERGENCY EXIT LIGHT MISSING SEAT 1D - MEL 3351S STOWED LITE ASSY AND SECURED WIRES. PLACED ON MEL. DDP C/W. REPLACED EMER LIGHT ASSEMBLY AT SEAT 1D,OPS NORMAL. VERIFIED INSTALL, SECURETY AND OPS SDR VNAA2019121431101Connector · damagedDAMAGED ELECTRICAL CONNECTOR FOR EMERGENCY LIGHT #4 (DS144) EA74-2019-019 DEFERRED LIGHT. INSTALLED NEW PINS ON #4 CABIN EMERGENCY LIGHT IAW ESPM 20-16-00. OPS CHECK GOOD IAW AMM 33-51-00-710-801-A01. THIS CLEARS MELSDR SWAA2019121639643Connector · disconnectedL/H OVERWING EXIT SIGN LIGHT WAS NOT WORKING. / CONNECTED SIGN LIGHT IAW AMM.SDR AALA201912139010Connector · disconnectedAIRCRAFT WAS NOT GROUNDED: SEAT 34DEF EMERGENCY LIGHT IN SEAT WAS INOPERABLE. MAINTENANCE RECONNNECTED CONNECTOR UNDER SEAT 34DEF PER AMM 33-51-11 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR SWAA2019121139529Connector · inoperativeINTERIOR EMERGENCY AISLE LIGHT INOP AT ROW 16. / RECONNECTED CONNECTOR D11334 IAW SWPM.SDR DALA2019121007201Connector · unsecureCEILING EMERGENCY LIGHTS INOPERATIVE AT DOORS 3L AND 3R AND SEATS 21 L AND 26L. RE-SECURED CONNECTORS AT DOORS 3L, 3R AND 4R, AND SEATS 21L AND 26L. LP 6700076.SDR REXA2019121291722Wire · brokenBOTH L/R OVERWING EXTERIOR (CENTER) EMERGENCY LIGHTS INOP
REPAIRED BROKEN WIRE ON BOTH L AND R OVERWING EXTERIOR LIGHTS (CENTER) IAW ESPM 20-16-00. OPS CHECK GOOD IAW AMM 33-51-00. NO FURTHER DEFECTS NOTED AT THIS TIMESDR AALA201912129042Connector · looseAIRCRAFT WAS NOT GROUNDED: EMERGENCY ESCAPE PATH LIGHTING FROM ROW 28 TO 40 INOPERATIVE. MAINTENANCE FOUND POWER SUPPLY CONNECTOR LOOSE AND RECONNECTED POWER SUPPLY CONNECTOR PER AMM 33-51-05 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA2019121109017Connector · looseAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK FOUND EMERGENCY ESCAPE PATH LIGHT AT SEAT 1D INOPERABLE. SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE FOUND EEPMS LIGHT CONNECTOR LOOSE AND RESECURED CONNECTOR AND PERFORMED SATISFACTORY OPERATIONAL CHESDR AALA2019121109016Connector · looseAIRCRAFT WAS NOT GROUNDED: FOUND EMERGENCY ESCAPE PATH LIGHTING FROM ROW 28 TO 40 INOPERABLE. MAINTENANCE FOUND POWER SUPPLY CONNECTOR LOOSE AND RECONNECTED POWER SUPPLY AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-05.SDR AALA2019121109010Connector · faultyAIRCRAFT WAS NOT GROUNDED: WHILE PERFORMING JOBCARD 26L00005005, PS CHECK, FOUND EMERGENCY LIGHT ON ROW 32 INOPERABLE. MAINTENANCE REPLACED EMERGENCY LIGHT CONNECTOR PER ESPM 20-44-14.