What was found
ELEC BURNING SMELL AND SUBSEQUENT SHOWER OF SPARKS FROM CAPTAINS LEFT GLARESHIELD FOUND LOOSE WIRE ON BACK OF RHEOSTAT(507) . NEED RHEOSTAT PART #86A2EZ8BA0689 FAULT CONFIRMED, LOOSE WIRE. REMOVED AND REPLACED RHEOSTAT SWITCH. SECURED ALL WIRES AND OPS CHECK GOOD. ALL WORK DONE IAW AMM TASK 33-11-00.