SDR DALA2019070504049Connector · unsecureEMERGENCY LIGHT AT SEAT 31AB INOPERATIVE. RE-SECURED LIGHT CONNECTOR AT THE WALL. LP 6053716.SDR AALA201907039007Connector · faultyAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHTS ROW 7L INOPERATIVE. MAINTENANCE REPLACED CONNECTOR ON EMERGENCY LIGHTS AT 7L AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER ESPM 20-48-14.SDR AALA201907029024Connector · unsecureAIRCRAFT WAS NOT GROUNDED: DURING EMERGENCY LIGHT TEST ON SEAT LIGHTS 35C AND 36C WERE INOPERABLE. MAINTENANCE FOUND CONNECTOR NOT SECURE AND PROPERLY SECURED CONNECTOR PER AMM 33-51-19.SDR SIMA20190701004Connector · brokenEMERGENCY FLOOR LIGHT STRIP AT FLOOR BOARD 251 BF WIRE CONNECTOR BROKE. C/A-REPLACED WIRE CONNECTOR AT FLOOR BOARD 251BF IAW SWPM 20-00-03 OPS CHECKS GOOD IAW AMM 33-50-00.SDR SWAA2019072335219Connector · looseEMERGENCY AISLE LIGHT CONNECTOR D11328 AT BS. 685, STR. 3R LOOSE. R&R CONNECTOR D11328 PER SWPM & AMM.SDR SWAA2019070834613Connector · defectivePHOTOLUMINESCENT STRIP AT AFT LAV INOPERATIVE. R&R WIRE CONNECTOR PER AMM.SDR AALA201907019030Wire · brokenAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHTS INOPERABLE ON SEATS 2D, 2H, 3D, 3H. MAINTENANCE REPAIRED BROKEN WIRE AT FRONT CONSOLE PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-07.SDR SIMA20190629002Connector · brokenTWO EMERGENCY LIGHT STRIPS HAVE BROKEN CONNECTORS. C/A-INSTALLED NEW CONNECTORS ON 2 EMERGENCY LIGHT STRIPS IAW SWPM 20-50-00, C/W OPS CHECK OF THE EMERGENCY LIGHTS/FLOOR STRIPS IAW AMM 33-50-00.SDR AALA201907029028Wire · cutAIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS EMGERGENCY LIGHT WIRE ASSY 286U0001-2085 INSTALLED AT SEAT ROW 33DEGH HAS A CUT. REMOVED & REPLACED CABLE ASSY IAW SWPM 20-001-2085. OPS CHECK TO BE ACCOMPLISHED ON CARD 26EL.SDR AALA201906289006Wire · disconnectedAIRCRAFT WAS NOT GROUNDED: 6AB FLOOR EMERGENCY LIGHT INOPERATIVE. ***SUPPLEMENTAL TO UPDATE SECTION 4 AND SECTION 5. MAINTENANCE RECONNECTED WIRE ON EMERGENCY LIGHT AT ROW 6AB PER STANDARD PRACTICES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.*** (CLOSED)SDR DALA2019062903991Connector · dirty(LOG 5693865) DURING INSPECTION FOUND AISLE PATH LIGHTING AT 24 DEF INOPERATIVE. REMOVED AND CLEANED DEBRIS FROM CONNECTOR IN SEAT IAW SWPM 20-10. OPS CHECK GOOD.SDR DALA2019062803910Connector · disconnectedEMEG LIGHTS INOP BETWEEN ROW 13 & 23. RECONNECTED CONNECTOR AT FLOOR AT SEAT 13 ED OPS CK GOOD. (LP5917986)SDR DALA2019062803909Wire · brokenSEAT 22ED EMERGENCY LIGHT (SEAT MOUNTED) INOP. FOUND BROKEN WIRE UNDERNEATH SEAT, REPAIRED WIRE IAW MD88 STANDARD PRACTICE 20-90 OPS CHECK GOOD. (LP6256244)SDR MASA2019062611923Connector · unsecureROW 14 A/C EMER EXIT SIGN INOP. SECURED THE CONNECTOR PLUG PIN BEHIND SIDEWALLSDR SWAA2019071034727Connector · looseFWD GALLEY EMERGENCY EXIT SIGN LOOSE AT CONNECTOR D3658. R&R CONNECTOR D3658 PER AMM.SDR DALA2019062603959Wire · brokenEMERGENCY ESCAPE PATH MARKING LIGHT INOPERATIVE AT 38AB AND 41AB. FOUND WIRE BROKEN UNDER SEAT 38A, 41A AND REPAIRED WIRES. SYSTEM OPERATION IS NORMAL.SDR DALA2019062960109Wire · misinstalledROW 45 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. FOUND ALL 3 LIGHTS WITH POWER AND GROUND WIRES REVERSED, CORRECTED GROUND WIRES. LP 5124033SDR SWAA2019071134716Connector · wornEMERGENCY LIGHT CONNECTOR PIN REQUIRES REPLACEMENT. RETERMINATED CONNECTOR W4142 PER WDM.SDR AALA2019062549039Connector · unsecureAIRCRAFT WAS NOT GROUNDED: 4H EMERGENCY LIGHT INOPERABLE. MAINTENANCE RESECURED LOOSE CONNECTOR PER AMM 33-51-12.SDR REXA2019062720985Wire · brokenWIRE BROKEN FOR WARDROBE EMERGENCY LIGHT. INSTALLED SERVICEABLE CONTACT ON WARDROBE EMERGENCY LIGHT AND INSTALLED CONTACT IN SPLICE CONNECTOR IAW CRJ 200 ESPM 20-17-10 OPS CHECK GOOD IAW CRJ 200 AMM 33-51-00-710-801.SDR DALA2019062633874Wire Harness · damagedDURING SERVICE CHECK, FOUND 12 EACH LED FLOOR PATH EMERGENCY LIGHTS SEAT MOUNTED INOPERATIVE ON LEFT SIDE ME/AFT CABIN. WIRE HARNESS REPAIRED.SDR AALA2019062549044Circuit Breaker · trippedAIRCRAFT NOT GROUNDED: PILOT REPORTS CABIN EMERGENCY LIGHTS C/B (A-1 ON P6-11 PANEL) FOUND OPEN ON PRE FLIGHT. MAINTENANCE RESET C/B ON P6-11 FOR CAB EMERGENCY LIGHTS. ALL TEST PASSED IAW FIM 33-50-00.SDR SWAA2019072935314Connector · missing#1 GALLEY EXIT LIGHT WIRE MISSING CONNECTOR. R&R LIGHT IAW AMM.SDR SWAA2019062434031Connector · disconnectedR2 DOOR AFT EXTERIOR EMERGENCY EXIT LIGHT INOP. / RECONNECTED CONNECTOR D11084 PER WDM AND AMM.SDR AALA201906219027Connector · not seatedAIRCRAFT WAS NOT GROUNDED: CID 1 EPSU SYSTEM TEST FAILED. MAINTENANCE RESEATED CONNECTOR AT EPSC 12WL AND PERFORMED SATISFACTORY EMERGENCY TEST BITE PER MM 33-51-00.SDR SIMA20190619008Wire · broken1EA PROX LIGHT WITH ARROWS AND 1EA PROX LIGHT WITH OUT ARROWS HAVE BROKEN WIRES-C/A-COMPLETE:REMOVED AND REPLACED 1EA PROX LIGHT WITH ARROWS AND 1EA PROX LIGHT WITH OUT ARROWS IAW EMB 145 AMM 33-50-12 SEE NRTC BOW324322 FOR FINAL INSTALL AND OPS CHECKSSDR SWAA2019062134011Wire · brokenEMERGENCY BATTERY PACKS INOP AT M1672. / FOUND BROKEN WIRE PER AMM, SPLICED PER AMM.SDR SWAA2019062134005Wire · brokenEMERGENCY BATTERY PACKS INOP AT M1669. FOUND BROKEN WIRE PER AMM, SPLICED PER AMM.SDR HNAA2019062000176Wire · brokenAFT PORTION OF OVER-WING EMERGENCY EXIT LIGHT DOES NOT ILLUMINATE....FIX:FOUND BROKEN WIRE W200-8508-20,CRIMPED NEW CONTACT AND CONNECTOR IAW 20-21-00. INSTALLED PANEL OPS CHECK GOODSDR YENA2019062480338Connector · brokenCONNECTOR BROKEN FOR CEILING EMERGENCY LIGHT AT ROW 18; REINSTALLED WHITE CONNECTOR ON WIRE 1 OF CEILING EMERGENCY LIGHT AT ROW 18. OPS CHECK GOOD. REF AMM 33-51-11.SDR AALA2019062099016Connector · disconnectedAIRCRAFT IN BASE MAINTENANCE, EMERGENCY LIGHTS FAILED TEST. FOUND WIRES PULLED OUT OF CONNECTOR, PINNED WIRES, RECONNECTED, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR R61A2019061870633Connector · disconnectedFWD EMERGENCY LIGHT EXIT LOCATOR SIGN INOPERATIVE. RECONNECTED PLUG AND OPS CHECK EMERGENCY LIGHT EXIT LOCATOR IAW AMM 33-50-13.SDR DALA2019062173720Wire · brokenEMERGENCY LIGHTS AFT OF RIGHT OF LAV 203 ARE INOPERATIVE. FOUND WIRE BROKEN UNDER CARPET AND REPAIRED. SYSTEM OPERATION IS NORMAL.SDR HNAA2019061800174Wire · brokenTHE SERVICE DOOR EMERGENCY EXIT LIGHT IS INOP. INVESTIGATION FOUND WIRE W716-0007-20 BROKEN. REPAIRED WIRE, OPS CHECK GOODSDR HNAA2019061800173Wire · damagedEMERGENCY EXIT LIGHTED SIGN ABOVE SERVICE DOOR THRESHOLD IS INOP...FIX: CLEANED AND RESEATED WIRE CONNECTIONS,OPS CHECK GOOD, CLOSED ACCESS PANEL AT SAID LOCATIONSDR AALA2019061869009Connector · looseAIRCRAFT WAS NOT GROUNDED: ESCAPE PATH LIGHTING CONNECTOR AT SEAT 14D WIRE PULLER LOOSE. MAINTENANCE REPLACED LIGHTING CONNECTOR PER AMM 33-53-00.SDR CALA2019061400955Wire · brokenEEPL HARNES, CONNECTOR 7260VC8, CONNECTING 31, 32 , 34ABC, HAS BROKEN WIRES 6 IN. FROM SEAT CONNECTOR. REFER TO AA R N/R: 9819958. REMOVED AND REPLACED EEPL HARNESS CONNECTOR 7260VC8 IAW A-320 AM M 33-51-22-400-802-C. THRU STEP 4.(4)(E). PERFORMED OPS CHECK IASDR SWAA2019061733715Connector · disconnectedEMERGENCY EXIT LIGHT AFT OF R/H OVERWING EMERGENCY DOOR NOT CONNECTED. CONNECTED LIGHT IAW AMM.SDR DALA2019061303563Connector · unsecureEMERGENCY LIGHTS AT ROW 13H, 14H, 15H, AND 29H DO NOT LIGHT UP ON TEST. RE-SECURED CONNECTORS AT SEAT 12H AND 29H. LP 5033420.SDR SWAA2019061833850Connector · missingAFT LAV EXIT LIGHT WIRES MISSING JIFFY CONNECTORS ON A/C SIDE. / INSTALLED JIFFY CONNECTORS PER SWPM AND WDM.SDR DALA2019061203541Connector · unsecureSEAT 5A, 6A,7A, 10H, 23B, 36B, 33B, AND 27B FOUND INOPERATIVE, RE-SECURED CONNECTORS AT EACH SEAT AND REPLACED SEAT 36B LIGHT ASSEMBLY. LP5714928SDR SIMA201906110002Connector · damagedSECOND TO LAST EMERGENCY LIGHT FLOOR STRIP INOP. EVALUATED AND FOUND 4 EA DAMAGED WIRE CONNECTORS FOR LAST AND ALSO SECOND TO LAST EMERGENCY LIGHT FLOOR STRIP. RAI'D LAST TWO EMERGENCY LIGHT STRIPS IAW AMM 33-50-12 . REPAIRED 4 EA WIRE CONNECTORS IAW SWPM 20-SDR AALA201906119008Wire Harness · inoperativeAIRCRAFT WAS NOT GROUNDED: PASSENGER SEAT ROW 12ABC EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REPLACED 12ABC EMERGENCY LIGHT WIRE HARNESS PER AMM 33-51-19 P.B.0401.SDR HNAA201906110166Connector · dirtyEMERGENCY EXIT SIGN ON AFT SIDE OF GALLEY AFT BULKHEAD WAS INOPERATIVE. REMOVED THE EXIT SIGN, CLEANED THE WIRE CONNECTIONS AND REINSTALLED SIGN USING RETAINED HARDWARE,OPS CHECKED GOODSDR DALA2019061203521Connector · disconnectedFOUND DOOR L1 EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RELAMPED L1 DOOR EMERGENCY LIGHT PER MD88 AMM 33-53. NO FIX. FOUND LIGHT ASSEMBLY DISCONNECTED BEHIND CEILING AND RECONNECTED IT. LIGHT OPERATIONAL CHECK IS OK PER MD88 AMM 33-53. (LP #5453557)SDR REXA2019061070815Wire · brokenEMERGENCY LIGHTS IN GALLEY WONT ILLUMINATE WHEN TESTED. REPAIRED BROKEN WIRE TO LIGHT ASSEMBLY IAW CRJ200 ESPM 20-16-00 . OPS CHECK GOOD.SDR DALA2019061763607Pin · abnormalDURING INSPECTION FOUND EMERGENCY PATH LIGHT AT SEAT 2A INOPERATIVE. FOUND PIN PUSHED BACK AT CONNECTOR. RESEATED PIN.SDR DALA2019060600101Connector · disconnectedDURING INSPECTION FOUND EMERGENCY LIGHT INOP AT SEAT 31B. FOUND LIGHT CONNECTOR DISCONNECTED, CONNECTED LIGHT, OPERATIONAL CHECK OK. LP 5987428SDR SIMA201906065003Connector · looseDURING PS-1 CHECK FOUND EXIT ROW RH EMERGENCY LT INOP.-C/A-CANON PLUG CONNECTOR LOOSE. REATTACHED IAW STANDARD MAINTENANCE PRACTICES. FUNCTION CHECK GOOD.SDR CA190812018Wire · burned(CAN) AT START OF SHIFT RECEIVED INFORMATION ABOUT DAMAGE FOUND TO R/H LANDING LIGHT AREA, NO RECORD IN TRAX, OR ON SHIFT HANDOVER PAPERWORK. UPON INSPECTION, FOUND LENS COVER AND LAMP REMOVED AND A VERY STRONG ODOR COMING FROM LANDING LIGHT LAMP COMPARTMENT.
Back to JASC 3397