What was found
SECOND TO LAST EMERGENCY LIGHT FLOOR STRIP INOP. EVALUATED AND FOUND 4 EA DAMAGED WIRE CONNECTORS FOR LAST AND ALSO SECOND TO LAST EMERGENCY LIGHT FLOOR STRIP. RAI'D LAST TWO EMERGENCY LIGHT STRIPS IAW AMM 33-50-12 . REPAIRED 4 EA WIRE CONNECTORS IAW SWPM 20-21-00. MEL ITEM RESTORED. "M" PROCEDURES COMPLIED WITH.