Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3500' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3500' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2022021500124None · noneCAPT SIDE O2 MASK RETAINING PIN BROKEN.(<P>REMOVED AND REPLACED CAPT SIDE O2 MASK BOX IAW AMM 35-11-51, OPS CHECK GOOD.</P>)SDR UIEA2022021400106None · nonePASSENGER MASKS OBSERVED DEPLOYED ROW 8 SEATS H K(<P>INSPECTED AND CHECKED AND STOWED PASSENGER OXYGEN MASKS AT SEATS 8 H K AS PER AMM 35-21-05 AND OK FOR SERVICE.</P>)SDR UIEA2022021400104Mask · inoperativeLH SUPERNUMERARY OXYGEN MASK INOP(<P>TRANSFERRED TO MDDR #161209 PER MEL 35-11-02-03A, CAT C. DUE: 23FEB22. PLACARDS INSTALLED. MCC ADVISED.</P> / <P>DISP: TS@ 1003Z.</P> / <P><SPAN>REMOVED AND REPLACED O2 MASK IAW AMM 35-11-51. OPS CHECK GOOD IAW AMM 35-11-00SDR UIEA2022021100101Mask · nonePORTABLE O2 BOTTLE MASK IN GALLEY CABINET EXPIRED.(<P>REMOVED AND REPLACED PORTABLE O2 BOTTLE MASK IAW B777 AMM 35-31-00. NO DEFECTS NOTED.</P>)SDR UIEA2022012700078None · noneCAPTS O2 MASK NOT WORKING PROPERLY.(<P>SWAPPED CAPTAINS O2 MASK WITH # 1 SUPERNUMARY O2 MASK IAW AMM 35-11-51. CAPT MASK OPS GOOD. # 1 SUPERNUMARY O2 MASK TRANSFERRED TO MDDR 160411 IAW MEL 36-11-03-02A, CAT C, DUE DATE 06FEB22.</P> / <P>CVG MX- 29JAN. LP 15SDR UIEA2022010400005None · noneCREW OXYGEN PRESSURE READS 40PSI ON EICAS INDICATION INOP.(<P>TRANSFER TO MDDR 159293 IAW MEL 35-11-02-01, CAT B.</P> / <P>LP 1604090 - REMOVED AND REPLACED VOLTAGE AVERAGING UNIT IAW AMM 35-11-06. OPS CHECK GOOD AT THIS TIME. THIS CLEARS MDDR 159293.</P>)SDR MASA20220125082None · corroded"CORROSION ON SIDE SEAT RAIL IN SECTION FS 744.15-FS761.85 STRG 15RH
SIDE SEAT RAIL IN SECTION FS 744.15-FS761.85 STRG 15RH WAS REPLACED PER CRJ/900 AMM 53-00-49"SDR UIEA2021121402454Mask · noneCOCKPIT CAPT. OXYGEN MASK HARNESS FRAYED(<P>REMOVED & REPLACED COCKPIT CAPT OXYGEN MASK AS PER BOEING 767 AMM 35-11-51.</P> / <P>OPS CHECK GOOD</P>)SDR UIEA2021121602463None · noneO2 BOTTLE NEAR L1 DOOR MISSING GLASS OVER PRESSURE GUAGE.(<P>PLACED ITEM ON DMI 158497 IAW MEL 35-31-01.</P> / <P>LP 1617077 ITEM 5 - REMOVED AND REPLACED L1 PORTABLE OXY BOTTLE IAW B767 AMM 35-31-01.</P>)SDR UIEA2021112902435Mask · noneFIRST OFFICER MASK IS NOT FLOWING O2 PROPERLY. EXTREMELY HARD TO BREATH THROUGH NEEDS TO BE REPLACED.(<P><SPAN>R&R FO O2 MASK IAW 35-11-51</SPAN></P>)SDR SWAA2021112346239Sign · incorrectSUPPLEMENTAL INFORMATION: LEFT AFT ENTRY DOOR EMERGENCY EXIT SIGH POIN TO THE WRONG DIRECTION ; / [01] REMOVED AND REPLACED PER SIP; [02] ENTERED ON LOG PAGE 1714474; [03] CERTIFY CORRECTIONSDR CALA2021112202145None · nonePAX O2 SWITCH INADVERT ANTLEY PUSHED. ALL MASKS DEPLOYED REPACKED ALL DEPLOYED MASKS IN THE CABIN AS REQUIRED, REF. AMM. 35-21-10, 11, 12, 13, 14, AND 15. ADD EMP:U241740,U233291,U330713SDR 2021F00312None · noneBATTERY PACK AT DOOR 1R DOES NOT OPERATE CORRECTLY , REPLACED BATERY PACK IAW AMM 33-51-06SDR UIEA2021102202272Mask · noneF/O O2 MASK HARD TP BREATHE.(<P>REMOVED AND REPLACED O2 MASK IAW AMM 35-11-51 OPS CHECK GOOD.</P>)SDR SWAA2021102832155Bulb · inoperativeL-1 DOOR UPPER EMERGENCY LIGHT WITH 2EA BULBS INOP ; / [01] RECITED BULBS (2EA) AT L-1 DOOR UPPER EMERGENCY LIGHT AS PER REF B737 AMM 33-51-01-960-801 PERFORMED OPERATIONAL TEST FOUND NORMAL; [02] VERIFIED STEP 1SDR UIEA2021102002261None · noneFWD E&E COMPT CREW OXYGEN NEED SERVICE TO FULL(<P>REMOVED, SERVICED & REINSTALLED CREW OXYGEN CYLINDER AS PER B767-300 AMM 12-15-08</P> / <P>AMM 35-00-00-012-005, AMM 35-11-00-206 AND AC 43.13-1B PAR 9-46 THRU 9-51 & NO LEAKS NOTEDSDR CALA2021101801908None · noneFOR SDR PURPOSES ONLY: REF FCD 3521-01339 REV B: ROW 38ABC OXYGEN COMPARTMENT, 2 EA MASK LANYARDS NOT ATTACHED TO THE GENERATOR FIRING PIN. SEE ATTACHED PICTURES. NR 463065SDR CALA2021101801907None · noneFOR SDR PURPOSES: REF FCD 3521-01339 REV B: ROW 27ABC OXYGEN MASK LANYARD NOT INSTALLED INTO SPLIT RING. SEE ATTACHED PICTURES. FROM NR 463059SDR CALA2021101801906None · noneFOR SDR PURPOSES ONLY: REF. FCD 3521-01339 REV B: FWD FA O2 GENERATOR ARRIVED TO CHECK WITH RED SHIPPING PIN INSTALLED AND STREAMER TUCKED INTO COMPARTMENT. SEE ATTACHED PICTURES. COPIED FROM NR 463059.SDR UIEA2021101302225None · noneOXYGEN PRESSURE INDICATING 40 PSI ON STATUS PAGE(<P>TRANSFERED TO DMI 155060 PER MEL 35-11-02-01.</P> / <P>REMOVED AND REPLACED VOLTAGE UNIT IAW AMM 35-11-06. OPS CHECK GOOD. THIS CLEARS MDDR 155060.</P>)SDR UIEA2021100802206Bottle · noneO2 BOTTLE DAMAGED DURING REPLACEMENT FOR SERVICING(<P>REMOVED AND REPLACED O2 BOTTLE IAW 767 AMM 12-15-08. LEAK AND OPS CHECK GOOD IAW 767 AMM 35-11-00.</P>)SDR UIEA2021100802205None · noneCAPTS O2 MASK MIC INOP(<P>SWAPPED CAPTS AND FIRST OFFICERS O2 BOX ASSY. CAPTS PNO MXP147 SNO 3875. FIRSTS OBS PNO MXP147 SNO 53357. OPS CHK NORMAL. REF AMM 35-11-51. TRANSFERRED TO MDDR 154761.</P> / <P>ONT MX-16OCT, LP 1371987: REMOVED AND REPLACED OBS OXY MASDR CALA2021092801715Mask · nonePASS O2 SWITCH INADVERT ENTLY ACTIVATED ON GND. ACP REPACK ON PSU, ADU,LSU O2 MASK PER AMM 35-22-31-440-801, 802. ACP RESET OF O2 PASSENGER ON LIGHT REF AMM 35-22-00. ACP O2 SYS MANUAL DEPLOY OP TEST PER AMM 35-22-00-700-802 TEST GOOD ADD EMP:U122702,U341425 ASDR P5CA2021092000352Mask · noneCOCKPIT PORTABLE OXYGEN FULL FACE MASK DUE TIME CHANGE P/N 10800C15F S/N TLS24986 MF 31 AUG 18(<P><SPAN>REMOVED & REPLACED PORTABLE OXYGEN FULL FACE MASK IN COCKPIT AS PER B767-300 FAMM 35-31-00</SPAN></P>)SDR P5CA2021092000353Mask · noneSUPERNUMERARY PORTABLE OXYGEN FULL FACE MASK DUE TIIME CHANGE P/N 10800C15F S/N TLS24972 MF 31 JUL 18(<P><SPAN>REMOVED & REPLACED PORTABLE OXYGEN FULL FACE MASK AS PER B767-300 FAMM 35-31-00</SPAN></P>)SDR P5CA2021053100214None · noneLAV PORTABLE OXYGEN MASK DUE TIME CHANGE MF JAN 13 P/N 289-601-212. REMOVED AND REPLACED LAV PORTABLE OXYGEN MASK AS PER AMM 35-31-01.SDR 2021FA0000079Oxygen System · leakingAIRCRAFT OWNER REPORTED HISSING SOUND ABOVE CABIN HEADLINER WHEN CABIN OXYGEN CONTROL WAS TURNED ON. PRESSURIZED OXYGEN SYSTEM AND CONFIRMED LOUD HISSING SOUND COMING FROM HEADLINER BETWEEN FIRST ROW OF PASSENGER SEATS. USED BORESCOPE TO INSPECT THE AREA, AND SDR UIEA2021012900152Avranging Unit · failedOXYGEN INDICATION DIFFERENT FROM BOTTLE GAUGE READING. REMOVED AND REPLACED VOLTAGE AVERAGING UNIT, IAW AMM 35-11-06. OPERATIONS CHECK GOOD.SDR 9JLA2020120920987Tee Fitting · leakingA FLIGHT WAS CANCELLED WHEN THE FLIGHT CREW DISCOVERED AN OXYGEN LEAK. THE MAINTENANCE TEAM DETERMINED THAT A OXYGEN LINE TEE FITTING LEAKING. THE DEFECTIVE TEE FITTING WAS REMOVED AND A NEW FITTING WAS INSTALLED PN AS4857-01. THE OXYGEN SYSTEM WAS SERVICE SDR 9JLA2020120828002Controller · leakingA FLIGHT WAS CANCELLED DUE TO THE OXYGEN LEVEL BEING LOW. THE MAINTENANCE TEAM TROUBLESHOT AND DETERMINED THAT THE OXYGEN CONTROLLER WAS DEFECTIVE. AN OVERHAULED UNIT WAS INSTALLED. THE OXYGEN BOTTLE WAS RESERVICED AND FUNCTIONAL CHECKS WERE SATISFACTORY. SDR R61A2020090300605Oxygen System · false indicationCREW OXYGEN LOW PRESSURE EICCAS MESSAGE APPEARED FOR 2 SECONDS WITH OBSERVER OXYGEN LOW PRESSURE IN BLUE. NO O2 CHANGES OBSERVED, NO CRE ALTITUDE FLUCTUATIONS. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. OXYGEN PRESSURE HAS NOT DROPPED AFTER 50 MINUTES, RESDR CA190607010Hose · damaged(CAN) DURING SCHEDULED MAINTENANCE IT WAS REPORTED BY SERVICE CENTER THAT THE 4 HOSES FOR PASSENGER OXYGEN WERE FOUND DAMAGED.SDR CA190610020Cap · missing(CAN) OXYGEN LINE - CAP IS SUSPECT OF NOT BEING INSTALLED, AS IT WAS NOT CALLED IN THE WORKBOOK (NOT PER DWG. REQUIREMENT) ++X++ (TC# 20190610020)SDR CALA2018111402374None · noneCAPTAIN INADVERTENTLY OPERATED THE O2 MASK PASSANGER SWITCH SEAT ROWS 8ABC,8DEF,10ABC,10DEF,11ABC 12ABC,22DEF,23DEF,24ABC,24DEF,25DEF,26ABC,26DEF,27ABC 28ABC,28DEF,29ABC,30ABC,31DEF,38ABC MUST BE PLACED ON MEL NOC DESK: 05 NAME: ALAN DATSDR AALA201809109014Slide · no testAIRCRAFT WAS NOT GROUNDED. REPLACED R2 DOOR SLIDE FOR TIME CHANGE AND NEW SLIDE FROM STOCK WOULD NOT PASS TEST. REINSTALLED ORIGINAL SLIDE PER JOB CARD, DEFERRED TIME CHANGE. TEST PASSED NO FAULTS.SDR EE4Y2018080907041Unknown · damagedDURING THE MAINTENANCE SERVICE COO FOUND AT BS 178 BULKHEAD SEVERAL PARTS DAMAGED, THE AFFECTED PARTS WERE
REPAIRED OR REPLACED AS FOLLOWS:
1- LH SIDE CHORD WITH CRACK AT WL 207 / REPLACED CHORD PER S/B 737-53A1173 REV 4 SECTION 3 ACCOMPLISHMENT
INSTRUCTIONSDR AMCR20180712004Tee Fitting · crackedTHE T-FITTING TO THE OXYGEN SYSTEM PRESSURE GAUGE AND TRANSDUCER HAS A CRACK ON ONE END. THE CRACK WAS FOUND VISUALLY AFTER IT WAS DETECTED ON TWO OTHER CJ4 AIRCRAFT.SDR BWVR20171201001Control Valve · failedMULTIPLE BAROMETRIC CONTROL VALVES INSTALLED AND FAILED "OUT OF BOX". VALVES WERE INSTALLED AS MODIFIED PART NUMBER OF CONTROL VALVES IS K39117/3, SERIAL NUMBERS THAT FAILED WERE S/N 1044/1 AND S/N 2301/2. BOTH UNITS WERE INSTALLED AS "MODIFIED"SDR UIEA2016112200902Door · missingLAVATORY OXYGEN MASK DOOR MISSING. INSTALLED THE DOOR IAW SMR 51-40-02-060.SDR REXA2016102602012Oxygen Mask · wrong partWRONG O2 MASK ON FWD PORTABLE OXYGEN BOTTLE. R & R THE MASK IAW AMM 35-31-04. ACFT GOOD FOR SERVICE.SDR CA150916001Indicator · faulty(CAN) MFG ENGINEERING DISCOVERED A DISCREPANCY BETWEEN THE APPROVED OVERBOARD DISCHARGE INDICATOR BLOW-OUT PRESSURE AND THE ACTUAL OVERBOARD DISCHARGE INDICATOR BLOW-OUT PRESSURE FOR OPERATOR. THE OVERBOARD DISCHARGE INDICATOR, PN 179001, BLOW-OUT PRESSURE WASSDR CA150525014B-Nut · cracked(CAN) DURING THE REPLACEMENT OF THE OXYGEN SYS CHARGING VLV WHICH WAS SUSPECTED OF A LEAK, IT WAS NOTICED THAT THE B NUT WHICH CONNECTS TO THE FILTER & IS PART OF THE MANIFOLD WAS CRACKED.SDR UIEA2014092200459Warning System · false activationSUPRNMRY OXY ON EICAS. RESET SUPRNMRY SYS IAW AMM 35-00-00 EICAS MSG CLEAR, CHECKED OK.SDR 9JLA2014091006628Shutoff Valve · leakingDURING OXYGEN SYS MAINTENANCE IT WAS DISCOVERED THAT THE MAIN OXYGEN BOTTLE VLV WOULD NOT SHUTOFF. THE O2 BOTTLE & VLV WERE REMOVED FOR OVERHAUL. IT WAS NOTED THAT THE OXYGEN BOTTLE SOV WAS OVERHAULED ONE YEAR PRIOR.SDR EVCA2014012300055Regulator · defectiveOXYGEN REGULATOR FAILURE WITH HOLE IN THE EXTERNAL CASING.SDR CALA2014011690165Oxygen Bottle · low pressureO2 READING 900 PSI. ACCOMPLISHED O2 SERVICING IAW MM REF 12-14-35. OPERATIONS CHECKED GOOD. NO LEAKS, AIRCRAFT OK TO CONTINUE.SDR CALA2013093091559Oxygen System · lowO2 AT 1190 LBS. SERVICED OXYGEN TO WITHIN OPERATING LIMITS. NO LEAKS NOTED.SDR UIEA2013031800136Sensor · malfunctionedNITROGEN GENERATATION STATUS MESSAGE, REPLACED OXYGEN SENSOR IAW AMM 47-42-02, SYS TESTED GOOD.SDR UALA2012103106260Oxygen Mask · missingDOOR 3L O2 MASK MISSING. MASK REPLACED.SDR UALA2012102906166Oxygen Mask · misinstalledCREW REPORT: OXY MASK ON WRONG AT OXY BOTTLE OVER 1A. RE-INSTALLED MASK TO PROPER POSITION.
Back to JASC 3500