SDR CALA2026041315286Sensor · faultedNITROGEN GENERATION SYSTEM OPERABILITY INDICATOR DEGRADED (BLUE) LIGHT IS ON. BLUE LIGHT ON NITROGEN GENERATOR. PERFORMED ELECTRICAL TEST FAILED OXYGEN SENSOR MESSAGE 47-30062 REF FIM 47-31-TASK 838, CHECKED UNIT, FOUND NO FUEL SMELL REPLACED OXYGEN SENSOR SDR CALA2025111711228Check Valve · faultedLEAK CHECK OF NITROGEN GENERATION SYSTEM, RESIDUAL FUEL & FUEL ODOR AT BOTH DRAIN PORTS, REQUIRES PRIMARY AND SECONDARY BACKFLOW PREVENTION CHECK VALVES TO BE CHANGED IAW AMM 47-21-04. R & R SECONDARY BACK FLOW PREVENTER PER AMM TASK 47-21-04. PERFORMED OSDR DXTA2025070804140Pressure Switch · faultedCOMING THROUGH 16,000 FEET ON OUR ARRIVAL THE EAGLE WE HAD WHAT APPEARED TO BE AN RAPID DECOMPRESSION. WE HAD A LOUD BANG, FOLLOWED BY CABIN ALTITUDE LIGHT. PASSENGER OXYGEN MASKS AUTO DEPLOYED, AND WERE USED BY PASSENGERS. CREW MASKS WERE USED AS WELL. OXYG