SDR 2008UALA03838Oxygen Mask · faultyCAPTAIN'S O2 MASK DOES NOT TRANSMIT THROUGH PA. WIRING SHORT INTERNAL TO MASK. REPLACED CAPT O2 MASK ASSY, OPS CHECKED NORMALLY.SDR 2008UALA03816Oxygen Mask · leakingLEAK IN CAPT'S OXYGEN MASK. HEAD STRAP HAS LEAK. LEAKING HEAD STRAP ON O2 MASK. REPLACED CAPT O2 MASK ASSY, OPS CHECKED NORMAL.SDR 2008UALA03784Oxygen Mask · no testCAPTAIN'S O2 MASK COMM WILL NOT TEST. *S/D* SHORT IN O2 MASK ASSY. REPLACED CAPT O2 MASK ASSY. OPS CHECKED GOOD.SDR 2008UALA03780Oxygen System · leakingCREW REPORT: CREW O2 LOW SHOWS 950LBS. *S/D* FOUND FLEX LINE CAPTAINS O2 MASK BOX LEAKING. REPLACED FLEX LINE, LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03770Oxygen System · malfunctionedCAPTAIN'S OXYGEN MASK YELLOW FLOWBAR INOP BUT O2 FLOWING TO MASK & HARNESS. CAPTAIN`S O2 MASK BOX (UNKNOWN ISSUE). REPLACED CAPTAIN`S O2 MASK BOX, ALL OPS TESTS ARE GOOD.SDR 2008UALA03735Oxygen System · lowCREW O2 PRESSURE IS SHOWING AT 50 PSI. SERVICED BOTTLE TO 1600 PSI AND CHECKED ALL CREW MASKS FOR LEAKS. VERIFIED NO LEAKS AND AFTER 1 HR BOTTLE PRESSURE STILL AT 1600 PSI, ACFT IS OK FOR SERVICE.SDR 2008UALA03731Oxygen System · lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 AND NO LEAKS NOTED AT TIME.SDR 2008UALA03737Line · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. *S/D* FOUND CAPTAINS SUPPLY FLEX LINE TO MASK BOX LEAKING. REPLACED FLEX LINE, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03617Oxygen Mask · defectiveOXYGEN MASK DEFECTIIVE AT1 (1=CAPT,2=1ST OFF,3=1ST OBS). CREW COMMENTS: CAPT O2 MASK EMERGENCY PRESS TO TEST BUTTON STICKS ON. DIRT ACCUMULATION IN SWITCH. REPLACED O2 MASK, OPS CHECKED GOOD.SDR 2008UALA03615Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK DOOR LATCH DOES NOT WORK PROPERLY. SUSPECT PRE FLIGHT CHECKS. REPLACED OXYGEN MASK BOX ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03591Oxygen System · reads lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA03515Oxygen Mask · leakingCREW REPORT: F-O O2 MASK INFLATABLE HARNESS LEAKING - NOTE: OBSERVER AND CAPT MASKS ARE GOOD. SWAPPED FO'S MASK WITH FIRST OBS MASK. FO'S MASK CHKS OK PER MM35-12-86. FIRST OBS SEAT INOP. REPLACED FIRST OBS SEAT MASK REF MM 35-12-86. AC OK FOR SERVICE.SDR 2008UALA03502Oxygen Bottle · reads lowCOCKPIT OXYGEN BOTTLE LOW. *S/D* SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA03500Oxygen Mask · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SUSPECT PRE FLIGHT CHECKS. LEAK CHECKED O2 BOTTLES, MASK BOX. SUSPECT CAPTAINS O2 MASK. SWAPPED OBSERVERS MASK WITH CAPTAIN'S MASK. REPLACED OBSERVERS MASK WITH NEW MASK SERVICED O2 TO 1800 PSI. ASDR 2008UALA03471Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03418Oxygen System · low pressureCREW O2 LEVEL LOW.SDR 2008UALA03435Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: O2 IS 1480 PSI. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03424Oxygen System · low pressureOXYGEN HIGH PRESSURE INDICATION AMBER ON DOOR-OXY SYSTEM ECAM PAGE - DOOR-OXY.SDR 2008UALA03356Hose · damagedOXYGEN MASK HOSE DEFECTIVE AT 2 (1=CAPT, 2=1ST OF, 3= 1ST OBS). CREW COMMENTS: HOSE IS BROKEN. BROKEN MASK HOSE (UNKNOWN DAMAGE). REPLACED HOSE ASSY, OPS CHECKED GOOD.SDR 2008UALA03313Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: SYSTEM READS 0. SAMC TEXT: PRESSURE IS LESS THAN 10 PSI. PURGE SYSTEM FIRST AND THEN SERVICE TO FULL.SDR 2008UALA03300Oxygen Bottle · underservicedCREW OXYGEN BOTTLE NEEDS SERVICE. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME.SDR 2008UALA03299Oxygen Mask · leakingO2 STILL SHOWS SLOW LEAK ABOUT 100 LBS PER 20 MIN. CAPT O2 MASK HAS PIN HOLE LEAK IN HOSE. REPLACED CAPT MASK ASSY, SERVICED CREW O2 TO FULL.SDR 2008UALA03276Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESS PRIOR TO SERVICING.SDR 2008UALA03326Oxygen Mask · faultyF/O OXYGEN MASK WILL NOT PRESS TO TEST. MASK INFLATES AND WORKS BUT TEST FUNCTION INOP.SDR 2008UALA03195Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. RESERVICE 1360 PSI. SERVICED 1740 PSI., NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA03176Oxygen Mask · faultyOXYGEN MASK PROBLEM. SUSPECT FAULTY MASK BOX ASSEMBLY. REPLACED MASK BOX ASSEMBLY PER MM 35-11-18. AC OK FOR SERVICE.SDR 2008UALA03173Bottle · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM TO FULL 1850 PSI. AC OK FOR SERVICE.SDR 2008UALA03194Oxygen System · low pressureCREW 02 NEEDS SERVICE. SERVICED CREW O2 TO FULL, NO LEAKS NOTED.SDR 2008UALA03100Oxygen Bottle · low pressureCREW OXYGEN BOTTLE PRESSURE LOW. REPLACED WITH SERVICEABLE CREW OXYGEN CYLINDER AND THEN LEAK CHECKED GOOD PER AMM 12-15-08 P 301. AC OK FOR SERVICE.SDR 2008UALA03034Oxygen Bottle · reads lowCREW O2 READING 1350 PSI. SUSPECT FAULTY OXYGEN BOTTLE. REPLACED O2 BOTTLE, LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02982Stowage Box · shortedF/O O2 MASK WILL NOT TEST IN STOWED POSITION, APPEARS OK WHEN REMOVED FROM STORAGE. SHORT IN O2 BOX. REPLACED F/O O2 MASK STOWAGE BOX.SDR 2008UALA02964Oxygen System · low pressureCREW REPORT: CREW OXYGEN READS 1050 PSI. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM TO FULL 1650 PSI. AC OK FOR SERVICE.SDR 2008UALA02958Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM TO FULL. AC OK FOR SERVICE.SDR 2008UALA02867Oxygen System · lowCREW O2 INDICATES 1000PSI.
SDR 2008UALA02881Oxygen Mask · defectiveCREW COMMENTS: F/O O2 MASK STRAPS WILL NOT TIGHTEN. SUSPECT PRE FLIGHT CHECKS. REPLACED FIRST OFFICERS OXYGEN MASK. AC OK FOR SERVICE.SDR 2008UALA02770Oxygen System · low pressureOXYGEN LOW.
SDR 2008UALA02771Oxygen System · low pressureO2 LOW READS 1370.SDR 2008UALA02733Oxygen System · low pressureFOUND CREW OXYGEN LOW ON ECAM. SERVICED O2 TO FULL. NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA02691Oxygen Mask · brokenF/O O2 MASK HAS BROKEN LEVER ON FRONT OF MASK. SUSPECT PRE FLIGHT CHECKS. REPLACED FIRST OFFICERS OXYGEN MASK. AC OK FOR SERVICE.SDR MWEA080067Oxygen Mask · leakingFIRST OFFICER'S OXYGEN MASK HAS A SMALL LEAK ON THE INFLATION HARNESS. REMOVED AND REPLACED OXYGEN MASK.SDR 2008UALA02692Bottle · low pressureCREW OXYGEN SYSTEM LOW. CREW COMMENTS: CREW O2 READS 1250. SUSPECT PRE FLIGHT CHECKS. SERVICED OXYGEN SYSTEM. AC OK FOR SERVICE.SDR 2008UALA02643Oxygen Mask · faultyFO O2 MASK HISSES, LEAKS WHEN DONNED. REPLACED FIRST OFFICERS O2 MASK PER MM 35-12-86. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02600Oxygen Mask · faultyFIRST OFFICER'S MASK LINES ARE FRAYED. REPLACED FIRST OFFICERS O2 MASK REF MM 25-11-11 PG 201 OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02599Oxygen Mask · faultyCAPTAIN O2 MASK LINES ARE FRAYED. REPLACED CAPTAINS O2 MASK REF MM 25-11-11 PG 201 OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02562Oxygen Mask · failedFLIGHT OFFICERS OXYGEN MASK FAILED LEAK CHECK. REPLACED FIRST OFFICERS O2 MASK, LEAK CHECKED GOOD.AC OK FOR SERVICE.SDR 2008UALA02535Valve · leakingCREW REPORT, SERVICE COCKPIT O2, 820 PSI AT 6C. FOUND LEAK AT EXTERNAL FILLER VALVE. REPLACED VALVE ASSEMBLY PER MM35-12-81. SERVICED TO 1800 PSI NO LEAKS. AC OK FOR SERVICE.SDR 2008UALA02530Oxygen Mask · damagedOXYGEN MASK HOSE DEFECTIVE AT 2 (1=CAPT, 2=1ST OF, 3= 1ST OBS). CREW COMMENTS, HEADBAND HAS A HOLE IN IT. SUPPLEMENTAL DATA UPDATE, UNKNOWN DAMAGE. REPLACED O2 MASK ASSY-FO.SDR 2008UALA02527Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK MICROPHONE IS INOPERATIVE. SWAPPED CAPTS AND 2ND OBS BOX. ALL LINES LEAK CHECKED GOOD. MASK AND RADIO OPS NORMAL AT CAPTAIN'S SPOT.SDR 2008UALA02508Oxygen System · reads lowO2 PRESSURE LOW. SERVICED CREW O2, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA02505Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2, PERFORMED LEAK CHECK WITH NO NOTED LEAKS AT TIME OF SERVICE.