Service difficulty reports · 2,419
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA02506Oxygen Mask · damagedFO'S OXYGEN FACE SHIELD IS DAMAGED. CREW COMMENTS, F/O O2 MASK INSIDE RUBBER CRACKED. TOP OF NOSE CONFORMING AREA. REPLACED MASK.SDR SWIA200819561Oxygen Mask · unwanted deployAFT FLIGHT ATTENDANT O2 MASK DEPLOYED ON LANDING. INSPECTED AND REINSTALLED O2 MASK.
SDR 2008UALA02449Transducer · leakingDURING TOW TO GATE, NOTICED CREW OXYGEN PRESSURE DROPPING FROM 1580 TO 1500, FOUND LEAK TO BE AT SERVICE PORT. REPLACED PRESSURE REGULATOR/TRANSDUCER, NO LEAKS WERE NOTED AFTER SERVICING.SDR 2008UALA02446Harness · leakingFO'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING). F/O`S O2 HARNESS LEAKING AT COUPLER. FOUND HARNESS COUPLER IS LEAKING O2. REPLACED F-O MASK STOWAGE BOX ASSY, NO LEAKS NOTED AFTER SERVICE.SDR NWAA081769762Line · leakingWHILE IN CRUISE FLIGHT AT FL320, THE CABIN ALTITUDE BEGAN CLIMBING UNCONTROLLABLY. FLIGHT CREW DECLARED AN EMERGENCY WITH ATC AND BEGAN A RAPID DESCENT TO LOWER ALTITUDES. AT FL280 THE CREW WAS ABLE TO REGAIN CONTROL OF THE CABIN ALTITUDE AND RECEIVED CLEARASDR 2008UALA02426Oxygen Mask · faultyCAPT O2 MASK MIC INOP SAMC TEXT: REPLACE CAPTAINS O2 MASK STOWAGE BOX. REPLACED OXYGEN MASK STOWAGE BOX.SDR 2008UALA02413Bottle · lowCREW AND PASSENGER OYXGEN LOW AT 1620 AND 1590 PSI RESPECTIVELY . SERVICED OXYGEN SYSTEM NO LEAKS NOTED. AC OK FOR SERVICE.SDR 2008UALA02408Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS, O2 WAS 1460 AT PUSHBACK AND 1300 AT START OF DESCENT AFTER 5 HOURS. FOUND LEAKAGE AT LOWER FITTING OF BOX. REPLACED BOX, PERFORMED LEAK CHECK AND SERVICE SYSTEM TO FULL.SDR 2008UALA02402Oxygen Mask · leakingSUSPECT O2 LEAK CAPTOR 1ST OBS MASK FITTING. FOUND 2ND OBS. MASK DISCONNECTED. SUSPECT LEAK FROM THERE. CONNECTED MASK AND CHECKED FITTINGS FOR LEAKS, NONE NOTED, SERVICED CREW O2 TO FULL.
SDR 6001LOXYGENOxygen Bottle · leakingINSTALLED REPAIRED EMERGENCY OXYGEN BOTTLE IN AC AND SERVICED. WHEN BOTTLE WAS TURN ON WAS FOUND TO LEAK FROM ON-OFF VALVE. UNIT WAS REPAIRED ON JANUARY 21,2008.SDR 2008UALA02350Oxygen System · reads lowCREW REPORTS CREW O2 LOW AT 1120 PSI. SERVICE CREW O2, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA02309Oxygen System · reads lowCREW OXYGEN IS LOW AT 1630 PSI, PASS OXYGEN IS GOOD AT 1760 PSI. SERVICED O2 SYSTEM TO PROPER LEVEL IAW MM12-15-08. AC OK FOR SERVICE.
SDR DL757080617Hose · rupturedIRR ON DESCENT CAPTS O2 DEVELOPED A LEAK, MILD POP HEARD FOLLOWED BY HISSING UNTIL O2 DEPLETION. FOUND CAPTS O2 MASK BOX SUPPLY LINE HOSE RUPTURED. REPLACED SAME LEAK CHECK OK.SDR 2008UALA02325Oxygen System · underservicedO2 REQUIRES SERVICING. SERVICED OXYGEN BOTTLE. AC OK FOR SERVICE.SDR 2008UALA02282Oxygen System · reads lowOXYGEN PRESSURE DECREASING. EICAS STATUS PARAMETERS DISPLAYED, OXY PRESS. CREW COMMENTS, AT TAKEOFF PRESS 1690, AT LDG 1530. RECONNECTED BOTH CREW OXYG EN MASKS AND LEAKED CHECKED GOOD.RESERVICED CREW OXYGEN PER AMM LEAKED CHECKED ALL FITTINGS AT CREW OXYGESDR 2008UALA02307Bottle · leakingCREW O2 READING 20PSI ON EICAS STATUS PAGE. O2 BOTTLE LEAKING AT REGULATOR.
REPLACED BOTTLE LEAK CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02301Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW, RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS, OXYGEN LOW 1390 PSI. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA02296Oxygen Mask · leakingCREW O2 NEEDS SERVICE. FOUND FIRST OBSERVERS O2 MASK LEAKING AT QUICK DISCONNECT FITTING, REPLACED MASK AND STOWED PER AMM 35-12-85. AC OK FOR SERVICE.SDR 2008UALA02269Oxygen System · reads lowCREW OXYGEN LOW. SERVICED CREW O2, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA02253Fitting · leakingCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. FOUND FIRST OBSERVERS O2 MASK LEAKING AT QUICK DISCONNECT FITTING, REPLACED MASK AND STOWED PER AMM 35-12-85 FOUND B-NUT LEAKING ON EXTERNAL FILL VLV. (B-NUT LOCATED INSIDE BOTTLE ACCESS PANEL) SECUSDR 2008UALA02240Oxygen Bottle · reads lowCREW O2 PRESSURE LOW AT 1500 PSI. SERVICED O2 BOTTLE. AC OK FOR SERVICE.
SDR 2008UALA02260Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. OXYGEN BOTTLE SERVICED TO 1850. AC OK FOR SERVICE.SDR 2008UALA02204Fitting · strippedFOUND ACFT CREW O2 SERVICE FITTING STRIPPED.SDR 2008UALA02174Oxygen System · reads lowFOUND CREW O2 LOW 1430 PSI. SERVICED CREW O2, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA02254Harness · leakingCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. FOUND FIRST OBSERVERS O2 MASK INFLATABLE HARNESS HAS HOLE AND WON`T INFLATE.
SERVICED SYSTEM. AND REPLACED MASK. AC OK FOR SERVICE.SDR 2008UALA02168Oxygen Mask · faultyCAPTAIN'S OXYGEN RESET SWITCH STICKY. REPLACED CAPTS WITH OBSERVERS O2 MASK ASSY CHECKS OK
SDR 2008UALA02198Oxygen System · reads lowCREW OXYGEN LOW. SERVICED CREW OXYGEN TO 1500PSI, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA02144Switch · illuminatedECAM MSG O2 REG LOW PRESS WITH SWITCH ON. FOUND LOW OXYGEN PRESSURE SWITCH FAILED. REPLACED LOW OXYGEN LOW PRESSURE SWITCH.SDR 2008UALA02119Bottle · lowCREW OXYGEN LOW, INDICATES 1100. SERVICED CREW O2, NO LEAKS WERE NOTED AT TIME OF SERVICE.
SDR 2008UALA02052Hose · frayedF/O O2 MASK GREEN HOSE FRAYED. SWAPPED WITH 1ST OBS POSTION AND LATER REPLACED ASSY.SDR 2008UALA01970Oxygen Mask · obstructedCREW O2 READS LOW. SUPPLEMENTAL DATA UPDATE, ISOLATED O2 LEAK TO FIRST OBSERVER'S O2 MASK. WITH MASK PLUGGED INTO FITTING MASK LEAKS. WITH MASK UNPLUGGED FROM FITTING NO LEAKS FROM FITTING. NEEDS NEW FITTING ASSY. REPLACED 1ST OBSERVER'S OXYGEN FITTING. SDR 2008UALA02008Oxygen System · reads lowCREW O2 LOW, NEEDS SERVICE (1520PSI). SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, NO LEAKS WERE NOTED AT THE TIME OF SERVICE.SDR 2008UALA01953Bottle · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED OXYGEN SYSTEM.SDR UPS08651966Regulator · leakingUPON BLOCKING IN, CREW O2 ON EICAS READS 250PSI AND FALLING. FOUND UPPER O2 REGULATOR LEAKING. REPLACED BOTH O2 REGULATORS AS PRECAUTIONARY.SDR 2008UALA01854Oxygen Mask · shortedCAPT O2 MASK MIC INOP. FOUND SHORT INSIDE MIC. REPLACED MASK AND STOWAGE BOX ASSY.SDR 2008UALA01775Oxygen Mask · crackedCAPTAIN'S OXYGEN MASK CRACKED. REPLACED MASK, OPS CHECKED NORMAL.
SDR 2008UALA01790Oxygen Mask · leakingF/O OXYGEN MASK LEAKS FROM THE HEADBAND.SDR 2008UALA01779Oxygen Mask · faultyCAPTAIN'S O2 MASK FAILS SELF TEST. FOUND FAULTY OXYGEN BOX AND MASK. REPLACED OXYGEN BOX AND MASK.SDR 2008UALA01768Oxygen Mask · faultyCAPTAIN'S O2 MASK RED PRESS TO TEST BUTTON MISSING SMALL PIECE OF BUTTON. MASK IS FULLY FUNCTIONAL. REPLACED CAPT O2 MASK ASSY, OPS CHECKED OK.SDR MASA200800264Oxygen Mask · unsecureASH FLT 2812 PHX-OKC. F/O OXYGEN MASK NOT SECURED. MX SECURED OXYGEN MASK.SDR 2008UALA01724Oxygen System · reads lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED OXYGEN SYSTEM.
SDR 2008UALA01700Oxygen System · reads lowCREW O2 NEEDS SVC 1350 PSI.SDR A6WA200840249Oxygen Bottle · inoperativeONE PORTABLE OXYGEN BOTTLE INOPERATIVE, ONE PORTABLE OXYGEN BOTTLE USED BELOW MIN. REMOVED AND REPLACED PORTABLE OXYGEN BOTTLE ASSEMBLY PER AMM 35-32-01. (M)SDR 2008UALA01687Oxygen Mask · no testF/O OXYGEN MASK WILL NOT TEST. CAUSE, UNKNOWN. REPLACED STOW BOX ASSY, OPS CHECKED OK.SDR 2008UALA01681Oxygen System · reads lowCREW O2 LOW. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, NO LEAKS WERE NOTED.SDR 2008UALA01677Cylinder · underservicedOXYGEN CYLINDER CREW NEED SERVICE. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01674Oxygen Bottle · reads lowAFT O2 BOTTLE LOW PRESSURE. REPLACED BOTTLE.SDR 2008UALA01686Oxygen System · reads lowCREW O2 READING 1200 (LOW). CAUSE, UNKNOWN. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01683Oxygen System · reads lowCREW OXYGEN SYSTEM, LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED OXYGEN SYSTEM.SDR 2008UALA01680Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW, RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: O2 PRESS 1370 PSI. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2 TO FULL. NO LEAKS WERE FOUND.