JASC 3510
Service difficulty reports · 2,419
Reports filed under 3510 · Crew Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3510' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2008UALA01676Cylinder · reads lowCREW OXYGEN CYLINDER PRESSURE LOW. REPLACED WITH SERVICEABLE CYLINDER AND THEN OPERATION AND LEAK CHECKED GOOD PER AMM 12-15- 08 P301. AC OK FOR SERVICE.SDR 2008UALA01682Mask · leakingFIRST OBSERVERS O2 MASK IS LEAKING. SUPPLEMENTAL DATA UPDATE CAUSE, MASK LEAKING AT PORT. REPLACED F OBS MASK. OPS CHECKED OK.SDR 2008UALA01679Oxygen System · reads lowCREW O2 IS LOW (1430PSI) FOUND ON 3SVC. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, LEAK CHECK OK.SDR 2008UALA01653Oxygen Mask · misinstalledCAPT'S RESET-TEST LEVER ON O2 MASK DOOR IS INOP. SUPPLEMENTAL DATA UPDATE CAUSE, MASK NOT STOWED PROPERLY. REINSTALLED MASK ASSY IN POSITION.SDR 2008UALA01627Oxygen System · reads lowCREW OXYGEN SYSTEM NEEDS SERVICE, CAUSE UNKNOWN. SERVICED CREW O2 SYSTEM, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01684Oxygen System · reads lowCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED OXYGEN SYSTEMSDR MASA200800246Door · brokenASH FLT 2737 PHX-PSP, F/O'S O2 MASK DOOR BROKEN. MX REPLACED THE MASK BOX ASSEMBLY.SDR 2008UALA01532Oxygen System · low pressureCREW O2 NEEDS REPLENISHING. SERVICED CREW O2. AC OK FOR SERVICE.SDR 2008UALA01485Oxygen Mask · dirtyCAPT O2 MASK SQUEEZE TO INFLATE MECH STICKY. REPLACED OXYGEN MASK. AC OK FOR SERVICE.SDR 2008UALA01484Bottle · low pressureCREW O2 1550 PSI. SERVICED CREW O2 TO 1800 PSI. AC OK FOR SERVICE.SDR 2008UALA01536Oxygen System · leakingCREW OXYGEN LOW CREW PRESSURE IS LOW. CREW COMMENTS: CONTINUOUS SLOW LEAK.SDR 2008UALA01498Oxygen System · lowCREW OXY SYSTEM NEEDS SERVICE. SERVICED CREW O2 SYSTEM, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01422Oxygen Mask · inoperativeF/O O2 MASK INOP. REPLACED F/O O2 MASK.SDR 2008UALA01354Oxygen System · lowTHE O2 NEEDS SERVICING SHOWS 1420. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01370Oxygen System · low pressureCREW O2 APPEARS TO HAVE A LEAK. SERVICED CREW O2 TO 2000 PSI, FOUND AT 1475, NO LEAKS WERE PRESENT AT TIME OF SERVICE.SDR 2008UALA01339Oxygen System · lowCREW O2 IS LOW AND NEEDS SERVICING. SERVICED CREW O2 TO FULL. NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01337Oxygen System · lowCREW O2 NEEDS SERVICE 1400 PSI. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01353Oxygen System · lowOXYGEN QUANTITY READS 1660 PSI. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT TIME OF SERVICE.SDR 2008UALA01336Oxygen System · lowCREW OXYGEN BELOW ETOPS MIN AT 1480 PSI. SERVICED CREW O2 TO FULL FOR ETOPS FLIGHT. NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA01308Oxygen System · lowCREW O2 LOW. SERVICED OXYGEN SYSTEM.SDR 2008UALA01296Seal · leakingINBD FLIGHT CREW, CHECK FOR SLOW 02 LEAK, LOST 200 PSI IN 2 HRS. FO FWD O2 MASK BOX LEAKING AT SEAL. REPLACED SEAL ON FO O2 STOWAGE BOX. LEAK CHECK NORMAL.SDR 2008UALA01284Solenoid Valve · faultyCREW O2 SYSTEM, OP CHECK OF LP SOLENOID FAILED. LP VALVE FAULTY. REPLACED LP SOLENOID VLV. OPS CHECKED OK.SDR 2008UALA01256Switch · faulty1ST OBSV O2 MASK EMERGENGY BUTTON STUCK ON. REPLACED SWITCH, OPS NORMAL.
SDR 2008UALA01147Regulator · leakingFIRST OFFICER OXYGEN MASK HARNESS LEAKING AIR AND WILL NOT INFLATE. FOUND LEAKING REGULATOR. REPLACED FO O2 MASK. OPS CHECKED OK.SDR 2008UALA01088Oxygen Mask · leakingHARNESS ON F/O MASK LEAKS. REPLACED O2 MASK.SDR 2008UALA01028Hose · leakingTHE 2ND OBS OXYGEN HOSE IN STORAGE BOX LEAKS. SUSPECT DAMAGED FROM PRE FLIGHT CHECKS. REPLACED MASK AND BOX PER MM35-11-51. OPS CKD NORMAL. AC OK FOR SERVICE.SDR 2008UALA00973Oxygen System · lowCREW O2 NEEDS SERVICING 1420 PSI. SERVICED CREW O2 TO FULL. NO LEAKS WERE NOTED FROM THE SYSTEM.SDR 2008UALA00974B-Nut · loosePREFLIGHT O2 SHOWS 400 PSI. REPLACED MASK AND SECURED B-NUT NO LEAKS FOUND. AC OK FOR SERVICE.SDR 2008UALA00959Oxygen System · low pressureTHE O2 NEEDS SERVICING. SHOWS 1420 PSI. SERVICED CREW O2 LEVEL TO FULL.SDR 2008UALA00952Oxygen System · lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 SYSTEM TO 1900 PSI AND LEAK CHECKED. NO LEAKS NOTED AT THE TIME OF SERVICE.SDR 2008UALA00935Regulator Valve · leakingCOCKPIT OXYGEN BOTTLE - LOW CREW COMMENTS: COCKPIT OXYGEN PRESSURE SLOW LEAK LOSING 100 PSI - HOUR IN FLT. LEAK AT PRESSURE REGULATOR. REPLACED PRESSURE REGULATOR, SERVICED CREW O2, LEAK CHECKED SYSTEM, ALL OK.SDR 2008UALA00862Oxygen Bottle · reads lowCOCKPIT OXYGEN BOTTLE, LOW CREW COMMENTS: CREW O2 NEEDS SERVICING. SERVICED CREW O2 TO FULL, NO LEAKS WERE NOTED AT THIS TIME.SDR AALA200800347B-Nut · looseIAD INFLIGHT T1281/17FEB BOS TO DFW - AT FL320 CREW REPORTED AIRCRAFT LOST PRESSURIZATION. OXYGEN MASKS DEPLOYED. LANDED IAD WITHOUT INCIDENT. SECURED LOOSE B NUT ON LEFT PACK SENSE LINE. FERRIED TO LGA. REPLACED ALL PASSENGER AND FLIGHT ATTENDANT OXYGEN SDR 2008UALA00908Connector · faultyCAPTAIN'S OXYGEN MASK DOES NOT TEST. YELLOW CROSS APPEARS BUT DOES NOT DISAPPEAR. RESET CONNECTOR. CHECKS OK.SDR 2008UALA00821Oxygen Mask · faultyCAPTAIN'S O2 MASK WILL NOT DEFLATE & MIC IS INOP. REPLACED CAPT O2 MASK, OPS CHECKED NORMALLY.SDR 2008UALA00716Oxygen System · low pressureOXYGEN NEEDS TO BE SERVICED. SERVICED O2 TO FULL, NO LEAKS WERE NOTED AT TIME OF SERVICE.SDR 2008UALA00680Oxygen System · low pressureCREW O2 SHOWS LOW 1460 PSI. SERVICED CREW O2 TO FULL, NO LEAKS NOTED AT THIS TIME.SDR 2008UALA00674Bottle · low pressureCREW O2 PRESSURE 1550, SUPPLEMENTAL DATA UPDATE, SUSPECT PRE-FLIGHT CHECKS. SERVICED OXYGEN BOTTLE. AC OK FOR SERVICE.SDR 2008UALA00663Oxygen Mask · no testCAPTAIN'S OXYGEN MASK NO TEST. FOUND LEAK WITHIN THE STORAGE BOX ASSY. REPLACED FAULTY STOWAGE BOX ASSY.SDR 2008UALA00662Oxygen Mask · no testCREW REPORT: FO AND OBS1 OXYGEN MASKS WORK WELL BUT WILL NOT PRESS TO TEST WITHOUT PUSHING ON INNER O2 DOOR. REPLACED BOX ASSY, OPS CHECKED NORMALLY.SDR 2008UALA00667Oxygen Bottle · low pressureCREW O2 NEEDS SERVICING. NOW AT 940 PSI.SDR DXTA200802825Oxygen Mask · leakingCAPT'S 02 MASK HOSE DEVELOPED A LEAK WHERE IT ATTACHES TO MASK AND COULD NOT STOP LEAK. INSTALLED NEW O2 MASK. OPS CHECK GOOD IAW MM CH 35-10-01. (K)SDR DXTA200802831Oxygen Mask · malfunctionedBOTH PILOT AND COPILOT OXYGEN MASK HAVE REDUCED OXYGEN FLOW, AS IF AN OBSTRUCTION OF VALVE FAILURE OCCURED. RESEATED OXYGEN MASKS OPS CHECKED SATISFACTORY IAW MM 35-00-00.SDR 2008UALA00591Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO 1740, HELD PRESSURE FOR 3 HOURS- NO LEAKS NOTED.SDR 2008UALA00587Oxygen Mask · misinstalledF-O OXYGEN MASK AND SPEAKER ARE INSTALLED IN REVERSE POSITIONS. FOUND TO BE INSTALLATION ERROR (QA). REINSTALLED OXYGEM BOX AND SPEAKER BOX IN CORRECT POSITIONS.SDR 2008UALA00588Oxygen Mask · faultyCREW REPORT: CAPT OXYGEN MASK MIC INOPERATIVE. FOUND ELECTRICAL SHORT IN WIRING IN CAPT O2 MASK MIC. REPLACED CAPT O2 MASK AND MIC ASSY. OPS CHECKED NORMAL.SDR 2008UALA00556Filler · leakingAIRCRAFT O2 LOW. SUPPLEMENTAL DATA UPDATE CAUSE: LEAKING FILL PORT ON CREW O2 SERVICING PANEL. REPLACED FILL PORT AND SERVICED CREW O2 TO FULL, NO LEAKS NOTED.SDR 2008UALA00513Oxygen System · low pressureCREW O2 NEEDS SERVICING 1420 PSI. SERVICED CREW O2 TO FULL, NO LEAKS NOTED.SDR 2008UALA00508Oxygen System · low pressureCREW OXYGEN IS LOW. SUSPECT LOW DUE TO PRE FLIGHT CHECKS. SERVICED CREW OXYGEN BOTTLE. ACFT OK FOR SERVICE.SDR 2008UALA00509Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2, NO LEAKS WERE NOTED AT THIS TIME.
Back to JASC 3510