SDR IPXA2022062083268Floor Mat · dentedINSPECTION TYPE:N/AAFT BULK CARGO DOOR OUTER SKIN DENTREPAIRED DAMAGED SKIN IAW E.O. A300-5230-83932-BSDR UIEA2022061900617Hose · frayedCOCKPIT CAPT OXYGEN MASK HOSE FRAYED. REMOVED & REPLACED CAPT O2 MASK PER B767-300 AMM 35-11-51. OPS CHECK GOOD NO LEAKS</P>)SDR JJBA20220618013None · noneO2 MASK WONT TEST. RESECURED O2 MASK BOX. OPS CHECK GOOD.SDR IPXA2022061883218Shear Web · corrodedINSPECTION TYPE:SEG3MAIN CABIN FLOOR SHEAR WEB AT FS 275 HAS SURFACE CORROSIONREMOVED CORROSION FOUND SHEAR WEB TO BE WITHIN LIMITS PER SRM 53-10-51-1A-1SDR IPXA2022071284095Floor Panel · wornINSPECTION TYPE:A300MDC FLOOR PANEL 232LF HAS PUNCTUREREPAIRED MDC FLOOR PANEL 232LF NEEDED IAW EO A300-5320--42722-FSDR UIEA2022060200567Mask · inoperativeCAPT O2 MASK NOT WORKING PROPERLY, HARD TO BREATH THROUGH. NEEDS TO BE REPLACED. R/R CAPT O2 MASK IAW AMM 767 BOEING 35-11-51. OPS CHECK GOODSDR JJBA20220527058None · noneREMOVED BOTH PILOTS AND COPILOTS O2 MASKS BOX FOR FOM AND FOUND FITTINGS DISCONNECTED. RECONNECTED FITTINGS AND INSTALLED BOTH O2 MASK BOXES. OPS CHECK SATSDR UIEA2022052300508Oxygen Bottle · noneFWD E&E SERVICE CREW OXYGEN TO FULL . SERVICED CREW OXYGEN CYLINDER AT FWD E E& COMPARTMENT AS PER B767-300 AMM 12-15-08-603-001, AMM 35-00-00-912-005, AMM 35-11-00-206-228, AMM 35-11-00-206-233. ADVISORY CIRCULAR AC 43.13-1B PGS 9-46 THRU 9-51 PGS 9-448 TSDR IXXA2022072203Skin Panel · corrodedLEFT WING TE EXTERNAL SKIN CORRODED AT WS 717.5 TO 775.5SDR IXXA2022072204Skin Panel · corrodedLEFT WING LOWER SKIN CORRODED FROM WS 150-177.5 AT AFT SPARSDR DALA2022052003501Bottle · low pressureSHIP 199 -DIV- TO IAD DUE TO LOW CREW OXYGEN PRESSURE AT TOP OF CLIMB. CORRECTIVE ACTION: REPLACED CREW O2 BOTTLE. NO LEAKS NOTED AT BOTTLE OR CREW O2 MASK LOCATIONS.(8854424)SDR IXXA2022072207Skin Panel · corrodedUPPER SURFACE LEFT WING ABOVE PYLON AREA CORRODEDSDR UIEA2022050600442Cylinder · overservicedE&E COMPARTMENT SERVICE CREW OXYGEN CYLINDER TO FULL. SERVICED CREW OXY CILINDER; AT LOWER; E&E AS PER; B767;AMM 12-15-08-603-001,35-00-00-412-005,35-11-00-206-228; 35-11-00-206-233.;ADVISORY CIRCULAR AC 43.13-1B; PAR 9-46 THRU; 9-51;PGS9-448THRU 9-459SDR UIEA2022050600451Bottle · out of dateE&;E COMPARTMENT CREW OXYGEN CYLINDER IS OUT OF DATE ,P/N 801307-00 S/N ST352350 MFG DATE 30 APR 97(REMOVED & REPLACED CREW OXYGEN BOTTLE AS PER B767-300 AMM 12-15-08. LEAK CHK GOOD AS PER B767-30 AMM 35-11-00-206-228..</P> / <P> </P>)SDR DALA2022042202820None · noneSHIP 3234 EXPIRED DUE DATE FULL FACE OXYGEN MASK THIRD OCCUPANT IN COCKPIT. CORRECTIVE ACTION: REPLACED MASK PER A320 AMM 35-12-41. (2205993)SDR UIEA2022041800312Bottle · low pressureCREW O2 LOW AT DEPARTURE CREW O2 READ 1600 ON ARRIVAL 1220(<P>REMOVED AND REPLACED CREW O2 BOTTLE IAW AMM 12-15-08 & LEAKED CHECKED OKAY PER GMM 3.25.3. NO DEFECTS NOTED AT THIS TIME . </P>)SDR UIEA2022032800243Tab · missingCA O2 MASK LEFT DOOR RETENTION TAB BROKEN AND MISSING.(<P>REMOVED AND REPLACED BOX ASSY, EQIP IAW AMM 35-11-51. OPS GOOD, LEAK CHECK GOOD.</P>)SDR AALA202203185768Stowage Box · defectiveAIRCRAFT IN BASE MAINTENANCE: FIRST OFFICERS MASK DOES NOT WORK PROPERLY. REPLACED OXYGEN MASK STOWAGE BOX AND ACCOMPLISHED A SATISFACTORY LEAK / OPERATIONAL CHECK PER AMM 35-12-41.SDR UIEA2022031100195Stowage Box · inoperative2ND OBSERVER O2 MASK TEST LEVER DOES NOT RETURN TO RESET PROPERLY.(<P>REMOVED AND REPLACED 2ND OBSERVERS O2 MASK STOWAGE BOX IAW 767 AMM 35-11-51, LEAK CHECK GOOD.</P>)SDR UIEA2022030400191Mask · inoperativeFIRST OBSERVER SEAT INOP (O2 MASK INOP)(<P>TRANSFERRED TO MDDR 162097 IAW MEL 25-11-02-01A, CAT A.</P> / <P>REPLACED OBS O2 MASK IAW AMM 35-11-51. THIS CLEARS MDDR 162097. ACL 2311Z</P>)SDR DXTA2022030357760Not Reported · not reportedOXYGEN HARDWARE: OXYGEN BOTTLE IN THE RIGHT FRONT NOSE COMPARTMENT IS SAFETY WIRED INCORRECTLY. THE ON/OFF LEVER IS NOT SAFETY WIRED TO THE ON POSITION. (ON PREFLIGHT)//CORRECTIVE ACTION// SAFETIED LEVER CORRECTLY IAW CE-560XL AMM CHAPTER 35-01-01SDR DALA2022030101307None · noneSHIP 8310 -DIV- TO DTW DUE TO CREW OXYGEN INDICATION DISPLAYS AMBER DASHES AND NOT ENOUGH FUEL FOR ALTITUDE RESTRICTIONS. CORRECTIVE ACTION: REPLACED CDC1 LRM 5, DC-18 POWER MODULE. (LP# 8583445)SDR UIEA2022022700182Mask · inoperativeSUPERNUMERARY SEAT 1 OXYGEN MASK INOP. THIS BECOMES MDDR# 161903 PER MEL 35-11-03-02A, CAT C, DUE 09MAR22. LOG 1439548 ITEM# 7: REMOVED AND REPLACED SEAT 1 SUPERNUMERARY OXYGEN MASK ASSY IAW AMM 35-11-51. OPS CHECK NORMAL. CLEARED MDDR 161903, PLACARD REMOVED.SDR 9JLA2022021734660Oxygen Mask · brokenTHE FLIGHT CREW REPORTED THAT DURING PREFLIGHT CHECKS IT WAS DISCOVERED THE PILOTS OXYGEN MASK GOGGLE PURGE LEVER WAS MISSING. THE BASE MAINTENANCE TEAM REMOVED AND REPLACED THE MASK WITH AN OVERHAULED UNIT. OPS CHECKS WERE GOOD. THE AIRCRAFT WAS RETURNED TO SSDR DALA2022021500982None · noneSHIP 3234 FIRST OFFICER OXYGEN MASK FAILED TEST. CORRECTIVE ACTION: DISCONNECTED AND RE-SEATED MASK SUPPLY LINE. OPS GOOD. NO LEAKS. (8361048)SDR IPXA2022071356953Skin Panel · damagedVERTICAL STABILIZER LEFT SKIN PANEL DAMAGE REPAIR DEFER PER EO 83598-REQ1SDR YENA2022012800027Stowage Box · failedFLT #603, EWR-SDQ (DIVERTED TO FLL). LEAK IN CREW OXY SYSTEM PSI DROPPED FROM 1150 TO 750 OVER 2.5 HRS ; FOUND LEAK AT CAPTS OXYGEN STOWAGE BOX, REMOVED AND REPLACED (10RN1) MASK STOWAGE BOX IAW AMM 35-12-41, NO LEAKS NOTEDSDR MTNA20211005001Oxygen Bottle · groovedTHE OXYGEN CYLINDER VALVE WAS FOUND TO HAVE A GROOVE AT THE REGULATOR CONNECTION CAUSING AN OXYGEN LEAK. MAINTENANCE REPLACED THE OXYGEN CYLINDER/VALVE ASSEMBLY WITH A SERVICEABLE UNIT. THE LAST HYDROSTATIC INSPECTION/OVERHAUL OF THE DEFECTIVE UNIT WAS PERFORMSDR UIEA2021091001998Oxygen Mask · failedCAPT O2 MASK 100% SWITCH STICKING. MASK EXTREMELY HARD TO BREATH THROUGH. NEEDS TO BE REPLACED.(<P>REMOVED AND REPLACED CAPT O2 MASK IAW AMM 35-11-51. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.</P>)SDR MTNA20210910002Oxygen Mask · inoperativePILOT OXYGEN MASK UNUSABLE. MAINTENANCE INSPECTED AND RESECURED LENS TO MASK AND PERFORMED OPERATIONAL CHECK.SDR CALA2021091001537Oxygen Mask · faultedFO''S OXYGEN FACE SHIELD IS DAMAGED. FO MASK DOES NOTSEAL WELLHAD TO HOLD ONFACE NIS ORD M&E REQUIRED 31-3515-9-9001 FO''S MASK HAS BEEN REPLACED SEE LOG PAGE 6965235 FOR SIGN OFFSDR UIEA2021090801987Oxygen System · malfunctionedCREW O2 INDICATION INOP.(<P>TRANSFERRED TO MDDR 153132 IAW MEL 35-11-02-01, CAT B.</P> / <P>REMOVED AND REPLACED AVERAGING UNIT IAW AMM 35-11-06. THIS CLEARS MDDR 153132.</P>)SDR UIEA2021083101919Cylinder · low pressureSERVICE CREW OXYGEN CYLINDER TO FULL(<P>SERVICED CREW OXYGEN CYLINDER AT LOWER E&E COMPARTMENT AS PER B767-300 AMM 12-15-08-603-001,</P> / <P>AMM 35-00-00-912-005, AMM 35-11-00-206-233 ADVISORY CIRCULARS. AC 43.13-1B PART 9-46 THRU 9-51</PSDR DALA2021082004874Oxygen Mask · misinstalledSHIP 3308 ALL MASKS DEPLOYED IN LDMCR. CORRECTIVE ACTION: INSPECTED PILOT AND BUNK #2 FOR ISSUES. BOTH LOCATION HAD IMPROPER OXYGEN MASK STOWED. PERFORMED ANOTHER DEPLOY. ALL LOC DEPLOYED AS INTENDED. (1917678)SDR DALA2021081904823Oxygen Box · openSHIP 3401 BUNK 2 O2 PANEL OPEN. CORRECTIVE ACTION: CLOSED PANEL. (7922525)SDR DALA2021082304972Oxygen System · no testSHIP 3314 FA1 BUNK O2 DROP TEST FAILED. CORRECTIVE ACTION: OPENED AND REPACKED MASK CONTAINERS. PERFORMED DROP TEST OF OXYGEN SYSTEM PER A330 AMM 35-21. (8919728)SDR DALA2021082304971Oxygen System · no testSHIP 3314 PILOT CREW REST BUNK INOP, NO O2 GEN, DROP TEST FAIL. CORRECTIVE ACTION: OPENED AND REPACKED MASK CONTAINER. PERFORMED DROP TEST OF OXYGEN SYSTEM PER A330 AMM 35-21. (8919727)SDR UIEA2021082001829Stowage Box · no testCAPT FLOW INDICATOR ON O2 MASK STOWAGE BOX DOES NOT TURN ON IN TEST MODE(<P>REMOVED AND REPLACED CAPT O2 MASK STOWAGE BOX IAW 767 AMM 35-11-51, OPS TEST GOOD, NO LEAKS NOTED</P>)SDR UIEA2021080401701Oxygen Mask · frayedFIRST OFFICERS OXYGEN MASK FRAYED ON RIGHT SIDE. REMOVED AND REPLACED F/O O2 MASK IAW B767 AMM 35-11-51 OPS AND LEAK CHECK GOOD AT THIS TIME.SDR UIEA2021080621679Bottle · low pressureFWD CARGO CREW OXYGEN NEED SERVICE TO FULL(<P>SERVICED CREW OXYGEN CYLINDER AT LOWER E&E COMPARTMENT AS PER B767-300 AMM 12-15-08-603-001,</P> / <P>AMM 35-00-00-912-005, AMM 35-11-00-206-228, AMM 35-11-00-206-233. ADVISORY CIRCULAR AC. 43.13-1B PAR. 9-46<SDR UIEA2021080301696Container · inoperativeFIRST OBSERVERS EMERGENCY O2 MASK INOP(<P>FIRST OBSERVERS SEAT AND EMERGENCY EQUIPMENT TRANSFERED TO MDDR # 151177 PER B 767 MEL 25-11-02-01A CAT A DUE DATE 04 AUG 21</P> / <P>LP 895909 ITEM 5 REINSTALLED FIRST OFFICERS O2 MASK MASK BOX IAW AMM 35-11-51-004SDR MTNA20210723001Oxygen Bottle · leakingDURING SERVICING OF O2 CYLINDER, IT WAS DISCOVERED THAT A LOUD STREAM OF AIR WAS ESCAPING FROM SMALL HOLE IN BACK OF CYLINDER VALVE NECK. REMOVED AND REPLACED O2 CYLINDER. PERFORMED LEAK CHECK WITH NO LEAKS DETECTED.SDR UIEA2021070801484Hose · leakingFOUND O2 LEAK BEHIND 1ST OBS O2 MASK BOX(<P>REMOVED AND REPLACED HOSE ASSY ON 1ST OBS O2 MASK BOX. NO LEAK NOTED IAW MM 20-10-10 AND 35-11-51</P>)SDR UIEA2021061301341Oxygen Mask · no testCAPTAIN 02 MASK HARNESS DOES NOT INFLATE DURING TEST(<P>REMOVED AND REPLACED CAPTAIN 02 MASK IAW AMM 35-11-51. OPS CHECK GOOD.</P>)SDR UIEA2021061101320Oxygen Bottle · low pressureFWD E & E CREW OXYGEN NEED SERVICE TO FULL. SERVICED CREW OXYGEN BOTTLE AS PER MM 12-15-08-608-801-001 AMM 35-00-00 AMM 35-11-00 AC 43-13-1B IAW 9-46 THOUGH 9-51 IAW 9-448 THOUGH 9-455 PN 1307-08. S/N 1507545 NO LEAKS.SDR UIEA2021061101321Oxygen Mask · deterioratedCOCKPIT SUPERNUMERARY PORTABLE OXYGEN FULL FACE MASK HAS DETERIORATED RUBBER ON HOSE. REMOVED AND REPLACED O2 MASK @ SUPERNUMERARY PORTABLE BOTTLE IAW B767 AMM 35-31-01.SDR UIEA2021061101322Oxygen Mask · deterioratedCOCKPIT PORTABLE OXYGEN FULL FACE MASK HAS DETERIORATED RUBBER ON HOSE(<P>REMOVED AND REPLACED O2 FULL FACE MASK IAW AMM 35-31-01.</P>)SDR UIEA2021061101323Oxygen Bottle · low pressureFWO CARGO SUPERNUMERARY OXYGEN NEED SERVICE TO FULL.(<P>SERVICE FWD CARGO SUPERNEMERARY OXYGEN BOTTLE AS PER B767-300 AMM 12-15-08, AMM 35-00-00, AMM 35-11-*00 AC 43-13-1B PER 9-46 THROUGH 9-51 PER 9-448 THROUGH 9-55 P/N 801307-00 S/N C17020688 NO LEAKS NOTEDSDR UIEA2021061101328Oxygen Bottle · low pressureFWD CARGO SUPERNUMERARY OXYGEN NEED SERVICE TO FULL. SERVICE FWD CARGO SUPERNEMERARY OXYGEN BOTTLE AS PER B767-300 AMM 12-15-08, AMM 35-00-00, AMM 35-11-00, AC 43-13-1B PER 9-46 THROUGH 9-51 PER 9-448 THROUGH 9-55. P/N 801307-00 S/N C17020688. NO LEAKS NOTEDSDR 9JLA2021061630021Unknown · leakingFLIGHT CREW REPORTS THEY ARE SUSPECT OF AN OXYGEN LEAK AFTER O2 QUANTITY DROPPED TO 76% AFTER BEING SERVICED. THE MAINTENANCE TEAM TROUBLESHOT AND DETERMINED THAT THE PILOTS SIDE AND 3RD CREW MEMBER EMERGENCY OXYGEN MASKS WERE LEAKING. THE PILOTS SIDE MASK P/N
Back to JASC 3510