What was found
CAPT FLOW INDICATOR ON O2 MASK STOWAGE BOX DOES NOT TURN ON IN TEST MODE(<P>REMOVED AND REPLACED CAPT O2 MASK STOWAGE BOX IAW 767 AMM 35-11-51, OPS TEST GOOD, NO LEAKS NOTED</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CAPT FLOW INDICATOR ON O2 MASK STOWAGE BOX DOES NOT TURN ON IN TEST MODE(<P>REMOVED AND REPLACED CAPT O2 MASK STOWAGE BOX IAW 767 AMM 35-11-51, OPS TEST GOOD, NO LEAKS NOTED</P>)