JASC 3520
Service difficulty reports · 2,734
Reports filed under 3520 · Passenger Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3520' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3520' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020122404255Oxygen Box · no testDURING TEST FOUND PSU OXY PANEL 32ABC WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122404254Oxygen Box · no testDURING TEST PSU OXY PANEL FOR SEAT 23 DEF WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122404253Oxygen Box · no testDURING TEST PSU OXY PANEL 28ABC WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122604260Panel · no testPSU/ OXYGEN PANEL DID NOT OPEN DURING TEST: LT SEAT ROW 3, 13, 16, 17, 18, 26, 28 AND RT SEAT ROW 2, 3, 10, 14, 17, 18, 20, 21, 22, 23, 25, 28, REF W/C 2527-01041-02 STEP 1 & 2. CORRECTIVE ACTION: C/W W/C 2527-01041-02. SECOND OPERATIONAL CHECK PASSED. ALL SDR DALA2020122304243Oxygen Mask · unwanted deployO2 MASK DEPLOYED AT SEAT 22D. CORRECTIVE ACTION: RE-PACKED MASK AT 22D, PER CMM 35-21-62.SDR DALA2020122404257Oxygen Box · openOXYGEN PANEL IN CENTER AISLE OF ROW 25 DROPPED DOWN AND HUNG ON 2 LATCHES DURING TAKEOFF, LATCHES SEEM TO BE BARELY ABLE TO KEEP THE PANEL SECURED. CORRECTIVE ACTION: REINSTALLED AND SECURED PSU PANEL ABOVE CENTER SEATS ROW 25, NO DEFECTS NOTED.SDR DALA2020121604113Oxygen Box · no testUPON TEST FOUND PSU OXY PANEL 24DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 24 DEF, AS PER A320 AMM35-21. OPERATIONS CHECK GOOD.SDR DALA2020121604112Oxygen Box · no testUPON TEST FOUND PSU OXY PANEL 31DEF NOT OPEN. CORRECTIVE ACTION: REPACKED PSU PANEL 31DEF, AS PER A320 AMM 35-21. OPERATIONS CHECK GOOD.SDR DALA2020121604110Oxygen Box · no testUPON TEST FOUND SEAT 12 DEF PSU OXY PANEL NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 12 DEF, PER A320 AMM 35-21. OPERATIONS CHECK GOOD.SDR DALA2020121604109Oxygen Box · no testUPON TEST FOUND SEAT 23 ABC PSU OXY PANEL NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 23 ABC, PER A320 AMM 32-21. OPERATIONS CHECK GOOD.SDR DALA2020121604108Oxygen Box · no testUPON TEST FOUND SEAT 1AB PSU OXY PANEL NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 1AB, PER A320 AMM 35-21. OPERATIONS CHECK GOOD.SDR DALA2020121704129Oxygen Mask · no testSEAT 29ABC O2 MASK DIDN`T DEPLOY PERFORMING O2 MASK TASK CARD 2527-01041-02. CORRECTIVE ACTION: R & R PASSENGER OXYGEN PANEL UNIT, REF A319 AMM 25-25. REMOVED OXYGEN GENERATOR FROM OLD OXYGEN PANEL & REINSTALLED IT ON NEW OXYGEN PANEL, REF A319 35-21. OPERASDR DALA2020121404087Oxygen Box · no testDURING TEST FOUND SEAT 13ABC DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 13ABC, PER A320 AMM 35-21. PERFORMED OPERATIONS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020121404086Oxygen Box · no testDURING TEST FOUND SEAT 24ABC DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 24ABC, PER A320 AMM 35-21. PERFORMED OPERATIONS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020121404085Oxygen Box · no testDURING TEST FOUND SEAT 23 DEF DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 23DEF, PER A320 AMM 35-21. PERFORMED OPERATUIBS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020121404084Oxygen Box · no testDURING TEST FOUND SEAT 22DEF DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 22DEF, PER A320 AMM 35-21. PERFORMED OPERATIONS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020121404083Oxygen Box · no testDURING TEST FOUND SEAT 17DEF DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 17DEF, PER A320 AMM 35-21. PERFORMED OPERATIONS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020121404082Oxygen Box · no testDURING TEST FOUND SEAT 17ABC DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 17ABC, PER A320 AMM 35-21. PERFORMED OPERATIONS CHECK, PER A320 AMM 35-23. OPERATIONS CHECK GOOD.SDR DALA2020122904335Psu · inoperativeFOUND OXYGEN PANEL AT 11ABC INOPERABLE DURING FORECAST NR 31-0525-8-0780. CORRECTIVE ACTION: REPLACED OXYGEN PSU PANEL AT SEAT ROW 11 ABC, REF A-319 AMM 25-25-43. OPERATIONS CHECK REF 35 -23-00 OK FOR SERVICE.SDR DALA2020120803998Oxygen Mask · unwanted deployO2 MASKS AT SEAT 26ABC WAS FOUND DEPLOYED. CORRECTIVE ACTION: R & R O2 PANEL ASSEMBLY. OPERATIONS CHECK GOOD.SDR DALA2020120403968Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED/LOCATIONS: 607. CORRECTIVE ACTION: RESECURED MASK INTO PANEL AND CLOSED AND SECURED PSU DOOR. OK FOR SERVICE.SDR DALA2020113003903Panel · inoperativeFOUND PSU OXY PANEL 15ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 15ABC. OK FOR SERVICE.SDR DALA2020112703889Panel · no testFOUND PSU OXY PANEL 30 ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 30 ABC. OK FOR SERVICE.SDR DALA2020112703888Panel · no testFOUND PSU OXY PANEL 26ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 26ABC. OK FOR SERVICE.SDR DALA2020112703887Panel · no testFOUND PSU OXY PANEL 23ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL 23ABC. OK FOR SERVICE.SDR DALA2020113003915Oxygen Mask · unwanted deploy25FED PAX 02 MASKS DROPPED. CORRECTIVE ACTION: RE-SECURED PSU DOOR AT PAX SEAT 25FED. NO FAULT NOTED. OK FOR SERVICE, PER A319/320 AMM 35-21.SDR DALA2020112403845Oxygen Mask · unwanted deployPASSENGER OXYGEN MASK DROPPED ROW 1 SEATS BC ON TAKEOFF. CORRECTIVE ACTION: VERIFIED O2 GEN NOT USED. REPACKED MASKS AND STOWED, IAW A319 AMM 35-20. OK FOR SERVICE.SDR DALA2020112403843Oxygen Mask · unwanted deployO-2 PANEL DEPLOYED ROW 17 D-E-F. CORRECTIVE ACTION: STOWED O-2 MASKS AT ROW 17 DEF, PER A319 AMM 35-21. A/C OK FOR SERVICE.SDR DALA2020112303832Oxygen Mask · unwanted deployO2 MASK OVER 2AB FELL OPEN ON TAXI IN. CORRECTIVE ACTION: RESTOWED O2 MASK OVER 2AB. OK FOR SERVICE.SDR DALA2020112303831Oxygen Mask · unwanted deployPASS O2 MASK ON ROW 25 A B C DROPPED. CORRECTIVE ACTION: STOWED MASKS AT ROW 25 A B C. A/C OK FOR SERVICE.SDR DALA2020112003798Oxygen Mask · unwanted deploy02 MASK DROPPED ROW 20. CORRECTIVE ACTION: INSPECTED ALL PAX O2 STORAGE AT ROW 20, IAW A350 AMM 35-21. OPERATIONS NORMAL.SDR DALA2020111903795Oxygen Box · no testFOUND PSU 02 PANEL AT 11ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 11ABC. OPERATIONS CHECKED GOOD.SDR DALA2020111903794Oxygen Box · no testFOUND PSU 02 PANEL AT 13ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 13ABC. OK FOR SERVICE.SDR DALA2020111903793Oxygen Box · no testFOUND PSU 02 PANEL 17DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 17DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111903792Oxygen Box · no testFOUND PSU 02 PANEL 10DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 10DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111903790Oxygen Box · no testWHILE IN MTC FOUND PSU OXY PANEL AT SEAT 27 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 27DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111903789Oxygen Box · no testFOUND PSU OXY PANEL AT SEAT 19DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 19DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111903788Oxygen Box · no testFOUND PSU OXY PANEL AT SEAT 25ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 25ABC. OPERATIONS CHECKED GOOD.SDR DALA2020111903787Oxygen Box · no testFOUND PSU OXY PANEL AT SEAT 23ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXY PANEL AT SEAT 23ABC. OPERATIONS CHECKED GOOD.SDR DALA2020112503872Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED IN FWD LAV. CORRECTIVE ACTION: RESTORED OXYGEN MASK IN FWD LAV. OPERATIONS CHECK GOOD.SDR DALA2020112503871Oxygen Box · openPSU/O2 PANEL DID NOT OPEN ON MASK RELEASE AT SEAT 28 LT. CORRECTIVE ACTION: UPON TESTING PSU/O2 PANEL AT SEAT 28 LT. OPERATIONS CHECKED GOOD.SDR DALA2020112303820Latch · brokenFOUND PSU LATCH BROKEN ON AFT LEFT LAV LAVATORY OXYGEN MODULE. CORRECTIVE ACTION: REMOVED AND REPLACED AFT LEFT LAV PSU OXYGEN MASK/ GENERATOR CONTAINER. OPERATIONS CHECKED GOOD.SDR DALA2020111903784Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED. CORRECTIVE ACTION: R & R F/C LAV EMERGENCY OXYGEN CONTAINER. OK FOR SERVICE.SDR DALA2020111903786Oxygen Box · no testPSU/O2 PANEL DID NOT DROP ON MASK RELEASE AFT F/A LT. CORRECTIVE ACTION: REPAIRED BROKEN WIRE ON PSU SOLENOID AFTER WIRE REPAIR PSU, OPERATIONS CHECK OK.SDR DALA2020111903785Oxygen Box · inoperativePSU/O2 PANEL DID NOT OPEN ON MASK RELEASE AT SEAT 11 LT. CORRECTIVE ACTION: RAN TEST AND PSU AT SEAT 11H. OPERATIONS CHECKED GOOD, OK FOR SERVICE.SDR DALA2020110503601Oxygen Mask · unwanted deployO2 MASKS IN THE PILOT BUNK AREA OF THE CREW REST MODULE DEPLOYED. CORRECTIVE ACTION: RESTOWED OPERATIONS TEST CARRIED OUT NO FAULTS.SDR DALA2020110203545Panel · abnormalOXYGEN PANEL ABOVE 35ABC FELL OUT OF CEILING. CORRECTIVE ACTION: SECURED O2 PANEL ABOVE ROW 35ABC.SDR DALA2020102903518Oxygen Box · inoperativePSU O2 PANEL IN SEAT 26 DEF DID NOT DROP. CORR REPACKED PSU 02 PANEL IN SEAT 26 DEF.SDR DALA2020102903517Oxygen Box · inoperativePSU O2 PANEL IN SEAT 24 DEF DID NOT DROP. CORR REPACKED PSU 02 PANEL IN SEAT 24 DEF.SDR DALA2020102903516Oxygen Box · inoperativePSU O2 PANEL IN SEAT 23 ABC DID NOT DROP. CORR REPACKED PSU 02 PANEL IN SEAT 23 ABC.
Back to JASC 3520