JASC 3520
Service difficulty reports · 2,734
Reports filed under 3520 · Passenger Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3520' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3520' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021032467232Support · corrodedINSPECTION TYPE:SEGFWD CARGO CEILING LINER SUPPORTS ARE CORRODED (3EA SAME P/W#)REMOVED, FABRICATED 1EA SUPPORT & INSTALLED IAW A300-600 SRM 51-40-21SDR DALA2021030101178Container · looseSHIP 3323 42H PASSENGER SERVICE UNIT LOOSE. CORRECTIVE ACTION: REPACKED O2 MASKS. INSTALLED IN CONTAINER AND CLOSED DOOR PER A330 AMM 35-21. (1742483)SDR DALA2021022301064Oxygen Mask · unwanted deploySHIP 3505 40 DEF OXYGEN MASK DROPPED ON LANDING. CORRECTIVE ACTION: CHKS O2 MASK & CYLINDER. ALSO SECURED & STOWED. (7666808)SDR DALA2021022301057Panel · no testSHIP 3274 DURING TEST FOUND PSU OXY PANEL 16ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE.SDR DALA2021022201035Oxygen Mask · unwanted deploySHIP 3514 2B & 2C O2 MASKS FELL. CORRECTIVE ACTION: STOWED AND SECURED O2 MASKS. CHECKED NORMAL. (7666758)SDR DALA2021021600882Panel · unsecureSHIP 3307 O2 PANEL OPENED ON TAKEOFF ROW 25 CENTER SECTION. CORRECTIVE ACTION: SECURED PANEL ASSY OK FOR SERVICE. (7683968)SDR DALA2021021100816Oxygen Mask · unwanted deploySHIP 3310 OXYGEN PANEL MASK DEPLOYED / LOCATIONS:206. CORRECTIVE ACTION: STOWED MASKS IAW A330 AMM 35-21. (1726960)SDR DALA2021021100815Oxygen Mask · unwanted deploySHIP 3310 OXYGEN PANEL MASK DEPLOYED / LOCATIONS:204. CORRECTIVE ACTION: STOWED MASKS IAW A330 AMM 35-21. (1726958)SDR UIEA2021020900260Oxygen Mask · not reportedO2 MASKS IN SUPERNUMRARY SEATS #2#3#4 INOP. MOVED #3 O2 MASK TO F/O P/N MC10-25-104 S/N B126S41 F/O OLD MASK MOVED TO # 3 POS P/N MC10-08-109 S/N 121011(<P>ITEM TRANSFERRED TO MDDR 142132 PER MEL 25-25-03 DUE DATE 08JUN21. </P><P>REF LP1017426 ITEM 1: REMOVEDSDR DALA2021020900752Door · no testSHIP 3259 DURING TEST SEAT 21ABC PSU OXY PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7583873)SDR DALA2021020900751Door · no testSHIP 3259 DURING TEST SEAT 3DEF PSU OXY PANEL DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7583872)SDR DALA2021020900754Oxygen Mask · no testSHIP 3256 DURING TEST PASSENGER O2 MASK DROP 18 DEF DID NOT DROP. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD. (7488982)SDR DALA2021020300639Oxygen Mask · exposedSHIP 3501 OXYGEN MASKS IN MID GALLEY EXPOSED AFTER LANDING. CORRECTIVE ACTION: RESECURRED MASK IN MID GALLEY. CKS GOOD. (7681281)SDR DALA2021020300637Oxygen System · inoperativeSHIP 3508 OXYGEN MASKS DROPS OPEN (NO FLOW). IN DRESSING OF PILOT CREW REST AREA. CORRECTIVE ACTION: CONFIRMED OXIGEN NOT DISCHARGED. LATCH MASKS OK. STOW AND SECURED PANEL PER A350 AMM 35-21. (7694208)SDR DALA2021020400677Psu · inoperativeSHIP 3268 DURING TEST AFT RT GALLEY OXYGEN PSU MODULE WOULD NOT DROP. CORRECTIVE ACTION R & R OXYGEN GENERATOR ASSY PER A320 AMM 35-21. OPS CK GOOD.SDR DALA2021020100602Door · no testSHIP 3231 DURING TEST PSU O2 PANEL IN SEAT 27DEF DID NOT OPEN. CORRECTIVE ACTION REPACKED MASKS. OPS CK GOOD.SDR DALA2021020100601Door · no testSHIP 3231 DURING TEST PSU 02 PANEL IN SEAT 3AB DID NOT OPEN. CORRECTIVE ACTON REPACKED MASKS. OPS CK GOOD.SDR DALA2021020100598Door · no testSHIP 3231 DURING TEST PSU O2 PANEL IN SEAT 30ABC DID NOT OPEN. CORRECTIVE ACTION REPACKED MASKS. OK FOR SERVICE.SDR DALA2021020100597Door · no testSHIP 3231 DURING TEST PSU O2 PANEL IN SEAT 25DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPS CK GOOD.SDR DALA2021020100596Door · no testDURING TEST PSU/O2 PANEL IN SEAT 19DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPERATIONS CHECK GOOD.SDR DALA2021020100595Door · no testDURING TEST PSU/O2 PANEL IN SEAT 15ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPERATIONS CHECK GOOD.SDR DALA2021020100594Door · no testDURING TEST PSU/O2 PANEL IN SEAT 10ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OPERATIONS CHECK GOOD.SDR DALA2021020100593Door · no testSHIP 3231 DURING TEST PSU O2 PANEL IN SEAT 3CD DID NOT OPEN. CORRECTIVE ACTION REPACKED MASKS. OPS CK GOOD.SDR DALA2021020100600Door · no testSHIP 3269 DURING TEST FOUND SOLENOID WAS BAD AT THE PSU AT SEAT 27ABC. CORRECTIVE ACTION: R & R OVERHEAD PASSENGER OXYGEN ASSEMBLY PER A-320 AMM 35-21. OPS CK GOOD.SDR DALA2021012100424Oxygen Mask · unwanted deploySEAT 03C OXYGEN PANEL MASK DEPLOYED. CORRECTIVE ACTION: REINSTALLED O2 MASK. SECURED AS PER A350 AMM.SDR DALA2021012100423Oxygen Mask · unwanted deploySEAT 03B OXYGEN PANEL MASK DEPLOYED. CORRECTIVE ACTION: INSPECTED AND INSTALLED O2 MASK, PER A350 AMM.SDR GTIA2021012335562Oxygen Gen · malfunctionedREF HAECO SO 122070 TC 352000-02-1. FOUND FA OXYGEN GENERATOR IN POSITION 30WR WITH PIN INSTALLED. REMOVED PIN FROM FA OXYGEN GENERATOR POSITION 30WR, REF TC 352000-02-1 AND NRI 22330.SDR DALA2021011400226Psu · no testDURING TEST PSU OXY PANEL 4AB DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021011400225Psu · no testDURING TEST PSU OXY PANEL 14ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021011400224Psu · no testDURING TEST PSU OXY PANEL 28ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021011300200Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED LOCATIONS: 42G. CORRECTIVE ACTION: 42G OXY MASK PANEL RESECURED.SDR DALA2021011200184Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED, LOCATIONS: 208. CORRECTIVE ACTION: RESTOWED & SECURED PANEL. CHECK OK FOR SERVICE, PER A330 AMM 35-21.SDR DALA2021011200177Psu · no testDURING DROP TEST PSU'S AT SEATS 21 ABC AND 27ABC DID NOT OPEN. CORRECTIVE ACTION: REPLACED PSU'S OPERATIONS CHECK GOOD SECOND TIME.SDR DALA2021011100163Psu · no testDURING TEST ROWS 2AB, 12ABC, 14DEF, 21DEF, 23DEF O2 MASKS DID NOT DEPLOY. CORRECTIVE ACTION: R & R PSU AT ROWS 2AB, 12ABC, 14DEF, 21DEF, 23DEF PER A320 AMM 25-25. PASSED SECOND TEST. OK FOR SERVICE.SDR DALA2021011100172Oxygen Mask · unwanted deployROW 23 O2 PANEL DROPPED. CORRECTIVE ACTION: STOWED O2 MASKS AND SECURED THE PANEL. CHECKED NORMAL, REF A350 AMM 35-21.SDR DALA2021010800131Psu · no testDURING TEST PSU OXY PANEL 26DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021010600071Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 27 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK OK.SDR DALA2021010600070Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 26 ABC DID NOT OPEN, REPACKED PSU. OK FOR SERVICE.SDR DALA2021010600069Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 24 ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021010600076Oxygen Mask · unwanted deployO2 MASKS DROPPED IN BUNK 2 & 3 IN LOWER CREW REST FACILITY. CORRECTIVE ACTION: O2 MASKS REFITTED, IAW AMM A330 35-21, NOW FUNCTION NORMAL.SDR 2021FA0000379None · noneO2 MASKS DROPPED DURING TAXI. FITTING HOLDING CONTAINER UP BROKE. MASK DROPPED FOR SPECIFIC CONTAINER.SDR DALA2021010400036Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED, LOCATIONS: 22H. CORRECTIVE ACTION: MASK RE-STOWED, NO OK FOR SERVICE.SDR DALA2020123104351Psu · no testRT FWD ENTRY DOOR PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: FOUND PSU OXY PANEL MOUNTING SCREWS MISSING. REPLACED SCREWS. TEST OK.SDR DALA2020123104350Psu · no testDURING TEST PSU AT SEAT 32R FAILED TO OPEN. CORRECTIVE ACTION: REPACKED PSU AND PERFORMED SECOND TEST. OPERATIONS CHECK GOOD.SDR DALA2020123004343Psu · no testDURING TEST FOUND PSU AT SEAT 26 DEF WILL NOT OPEN. CORRECTIVE ACTION: REPLACED PSU PANEL. OPERATIONS CHECK GOOD.SDR DALA2020123004342Psu · no testDURING TEST FOUND PSU AT SEAT 28DEF WILL NOT OPEN. CORRECTIVE ACTION: REPLACED PSU. OPERATIONS CHECK GOOD.SDR DALA2020123004341Psu · no testDURING TEST FOUND PSU AT SEAT 2CD WILL NOT OPEN. CORRECTIVE ACTION: REPLACED PSU. OPERATIONS CHECK GOOD.SDR DALA2020123004345Psu · no testROW 32RH SIDE PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: ON SECOND TEST PSU PANEL PASSED TEST. OK FOR SERVICE.SDR DALA2020123004344Psu · no testROW 1LH PSU PANEL FAILED TO OPEN ON OXY MASK TEST. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122804316Oxygen Mask · unwanted deployO2 MASK AT ROW 24 DROPPED. CORRECTIVE ACTION: O2 MASK REINSTALLED PROPERLY.
Back to JASC 3520