JASC 3530

Service difficulty reports · 272

Reports filed under 3530 · Portable Oxygen System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR VNAA2020021281102Hose · cutAFT PORTABLE OXYGEN MASK NOT CONNECTED/HOSE CUT. REMOVED AND REPLACED AFT PORTABLE OXYGEN MASK.Feb 8, 2020 · N552NN · Cndair CL6002D24SDR UIEA2019122056081Oxygen Bottle · emptyPORTABLE O2 BOTTLE READS ZERO BESIDE F/A SEAT R2 DOOR. (<P>REMOVED AND REPLACED O2 BOTTLE,<SPAN> AND REGULATOR </SPAN><SPAN>(OFF PART: P/N </SPAN><SPAN>801160-3</SPAN><SPAN>, S/N </SPAN><SPAN>34579</SPAN><SPAN>), </SPAN><SPAN>PER B747 AMM 35-31-00-900-801 AT FDec 18, 2019 · N464MC · Boeing 747446SDR UIEA2019110505853Oxygen Mask · damagedPORTABLE MASK RUBBER CRACKED.(<P>REMOVED AND REPLACED PORTABLE O2 MASK IAW LOPA DRAWING #B767F 25-EEL REV 11. OPS CHK NORMAL AT THIS TIME. </P>)Nov 5, 2019 · N1427A · Boeing 767306SDR UIEA2019081435146Oxygen Bottle · low pressureEMERGENCY O2 TANK BY ACCESSORY PANEL BELOW THE REQUIRED MARK. REMOVED O2 BOTTLE. INSTALLED THE PORTABLE OXYGEN BOTTLE AS REQUIRED PER AMM 35-31-01. BOTTLE PRESSURE CHECKED OK AND NO LEAKS NOTED.Aug 13, 2019 · N1373A · Boeing 76731KSDR CALA2019061400941Oxygen Gen · missingIDTINSPECTION REQUIRED REFERENCE WORK CARD 63-3500-1-2100 F/C FWD CENTER, LEFT CLOSET SUPPLEMENTAL OXYGEN UNIT MISSING O2 GENERATORS INSTALLED 2 EACH O2 GENERATORS AS REQUIRED REF AMM 35-35-98-000-801C1. OK FOR SERVICE.Jun 13, 2019 · N641UA · Boeing 767322SDR UIEA201902263335Lens · crackedGALLEY PORTABLE OXYGEN BOTTLE GAUGE LENS CRACKED. REMOVED AND REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01.Feb 24, 2019 · N1709A · Boeing 767375SDR REXA2018091700861Oxygen Bottle · leakingDURING INSTALLATION OF 4LPM MASK TO A PORT ON BOTTLE, HISSING SOUND NOTED. BOTTLE PRESSURE BECAME TO LOW TO USE. REPLACED WITH NEW O2 BOTTLE AND O2 4LPM MASK (BLUE) IAW JOB CARD 35-900-750.Sep 15, 2018 · N8839E · Cndair CL6002B19SDR REXA2018082800720Hose · cutPORTABLE OXYGEN MASK HOSE WAS CUT. REMOVED AND REPLACED THE OXYGEN MASK IAW AMM 35-30-00-02.Aug 28, 2018 · N8877A · Cndair CL6002B19SDR REXA2018082870726Oxygen Bottle · low pressurePORTABLE OXYGEN BOTTLE HAD LOW PRESSURE. REMOVED AND REPLACED THE PORTABLE OXYGEN CYLINDER IAW AMM 35-31-01.Aug 27, 2018 · N916XJ · Cndair CL6002D24SDR REXA2018081000681Cylinder · low pressurePORTABLE OXYGEN CYLINDER PRESSURE 1500, REMOVED & REPLACED THE CYLINDER IAW AMM 35-31-01-00-801.Aug 10, 2018 · N398CA · Cndair CL6002C10SDR REXA2018070300587Oxygen Mask · leakingPORTABLE O2 4LMP MASK IS LEAKING FROM GREEN INDICATOR AREA. R&R PORTABLE O2 4LPM MASK IAW AMM 35-31-01.Jun 30, 2018 · N8694A · Cndair CL6002B19SDR REXA2018052200404Oxygen Bottle · emptyDURING MORNING PREFLIGHT BY FLIGHT ATTENDANT FOUND PORTABLE 02 BOTTLE TO BE ON AND EMPTY. REMOVED AND REPLACED PORTABLE 02 BOTTLE WITH NEW UNIT. PN ON & OFF 5500-C1A-Y0EE SN ON 191291 SN OFF 174826 IAW AMM 35-31-01.May 22, 2018 · N8894A · Cndair CL6002B19SDR REXA201805010328Oxygen Bottle · low pressureFWD PORTABLE OXYGEN BOTTLE HAD LOW PRESSURE. REMOVED & REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-00.Apr 29, 2018 · N678CA · Cndair CL6002D24SDR REXA2018031500192Oxygen Mask · missingFWD FA POB MISSING FACE MASKS. REPLACED TWO O2 BOTTLE MASK IAW AMM 35-31-04.Mar 15, 2018 · N909XJ · Cndair CL6002D24SDR REXA2018021000110Oxygen Bottle · emptyFWD PORTABLE OXYGEN BOTTLE READS ZERO PSI. REMOVED AND REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01.Feb 10, 2018 · N902XJ · Cndair CL6002D24SDR REXA2018020900109Oxygen Bottle · low pressurePORTABLE OXYGEN BOTTLE HAD LOW PRESSURE. R & R THE OXYGEN BOTTLE IAW AMM 35-31-01. LEAK CHECKED GOOD. OK FOR SERVICE.Feb 9, 2018 · N902XJ · Cndair CL6002D24SDR REXA2018011100017Oxygen Bottle · emptyAFT PORTABLE OXYGEN BOTTLE DEPLETED. REMOVED & REPLACED THE OXYGEN BOTTLE IAW 35-31-61.Jan 11, 2018 · N931XJ · Cndair CL6002D24SDR REXA2017122001266Hose · damagedPORTABLE OXYGEN BOTTLE 4LMP MASK HOSE DAMAGED. REMOVED AND REPLACED THE MASK ASSEMBLY.Dec 20, 2017 · N8905F · Cndair CL6002B19SDR REXA2017121701254Oxygen Bottle · emptyAFT PORTABLE OXYGEN BOTTLE READS ZERO. REMOVED AND REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01.Dec 17, 2017 · N904XJ · Cndair CL6002D24SDR REXA2017121601253Oxygen Bottle · reads highPORTABLE O2 BOTTLE ABOVE SEAT 20 IS DISPLAYING QUANTITY IN THE RED ZONE. REMOVED AND REPLACED THE AFT PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01.Dec 16, 2017 · N904XJ · Cndair CL6002D24SDR REXA2017110101139Oxygen Mask · leakingO2 BOTTLE S/N ST65420 BLUE MASK (4LPM) LEAKING. REPLACED 4LPM BLUE MASK OF O2 PORTABLE BOTTLE IAW AMM 35-31-01.Nov 1, 2017 · N8986B · Cndair CL6002B19SDR REXA2017101701102Oxygen Mask · leakingTHE LPM MASK, FLOW INDICATOR LEAKS. REMOVED AND REPLACED PORTABLE OXYGEN BOTTLE MASK IAW AMM 35-31-01. CHECKED GOOD.Oct 17, 2017 · N8869B · Cndair CL6002B19SDR REXA2017101101085Oxygen Mask · leakingOXYGEN MASK LEAKING AT RESERVOIR BAG INDICATOR. R & R THE OXYGEN MASK ON THE PORTABLE OXYGEN BOTTLE IAW AMM 35-30-00. LEAK CHECKED GOOD.Oct 11, 2017 · N8883E · Cndair CL6002B19SDR REXA2017091801011Oxygen Bottle · low pressureFA REPORTED FOWARD EMERGENCY OXYGEN BOTTLE PRESSURE APPEARS LOW. REMOVED & REPLACED THE OXYGEN BOTTLE IAW AMM 35-31-01. NO DEFECTS NOTED. ACFT OK FOR SERVICE.Sep 18, 2017 · N309PQ · Cndair CL6002D24SDR REXA2017091501005Oxygen Bottle · low pressureBOTH PORTABLE OXYGEN CYLINDERS ARE LOW. REMOVED AND REPLACED THE OXYGEN BOTTLES IAW AMM 35-31-01-000-801, AND 35-31-01-400-801. OK FOR SERVICE.Sep 15, 2017 · N309PQ · Cndair CL6002D24SDR REXA2017091000998Gauge · brokenFORWARD PORTABLE OXYGEN BOTTLE GAUGE BROKEN. REMOVED & REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01. OPS CHECKED GOOD.Sep 10, 2017 · N602LR · Cndair CL6002D24SDR REXA2017090100965Oxygen Bottle · emptyFWD FA PORTABLE O2 BOTTLE EMPTY. REPLACED FWD FA PORTABLE O2 BOTTLE P 5500-C1A-Y0EE SER P14082952 WITH FULL BOTTLE IAW AMM 35-331-01.Sep 1, 2017 · N921XJ · Cndair CL6002D24SDR REXA2017082200924Oxygen Mask · inoperativeOXYGEN BOTTLE MASK QD BALLS STICK RETRACTED. R & R THE OXYGEN MASK, OP'S CHECKED GOOD IAW 35-900-700.Aug 22, 2017 · N832AY · Cndair CL6002B19SDR REXA2017082200919Oxygen Bottle · emptyAFT PORTABLE OXYGEN BOTTLE READS ZERO PRESSURE. R & R THE OXYGEN BOTTLE IAW AMM 35-31-01.Aug 22, 2017 · N915XJ · Cndair CL6002D24SDR UIEA2017080901445Hose · deterioratedUPPER DECK PORTABLE OXYGEN BOTTLE SUPPLY HOSE IS DETERIORATED. REMOVED AND REPLACED OXYGEN BOTTLE SUPPLY MASK IAW AMM 35-31-00-900-801.Aug 19, 2017 · N473MC · Boeing 74745ESDR DALA2017081206161Gauge · brokenBROKEN PRESSURE GAUGE ON PORTABLE OXYGEN CYLINDER S/N 587131 ALSO ON S/N 241191 AT CABIN PAX. REPLACED BY S/N 684325 AND 821117 DATE OF EXPIRATION 5/2019 AND 8/2019 P/N 9700C2CF20D. (LP 0160731)Aug 11, 2017 · N904DL · Doug MD88SDR REXA2017080700863Oxygen Bottle · emptyAFT OXYGEN BOTTLE DEPLETED. REPLACED THE AFT OXYGEN BOTTLE IAW AMM 35-31-01.Aug 7, 2017 · N601LR · Cndair CL6002D24SDR REXA2017080100846Oxygen Bottle · emptyFA REPORTED FWD CABIN PORTABLE O2 BOTTLE AT 0. REPLACED FWD CABIN O2 BOTTLE IAW MM 35-31-01-400-801-A05. ALSO REF TS000755-2013. VERIFIED PRESS FULL.Aug 1, 2017 · N929XJ · Cndair CL6002D24SDR REXA2017073100844Pbe · unserviceableFLIGHT DECK PBE OTS SOFT TO THE TOUCH HAS LOST VACCUM SEAL. R&R CAPT PBE IAW AMM 35-31-06.Jul 31, 2017 · N605LR · Cndair CL6002D24SDR REXA2017073000841Oxygen Bottle · emptyDURING WAKE UP CK NOTED FWD PORTABLE O2 EMPTY. R&R FWD 02 PORTABLE BOTTLE IAW AMM 35-31-01 P/N OFF ON 5500CLAY0EE S/N # ST 22555 OFF S/N # P07052119.Jul 30, 2017 · N916XJ · Cndair CL6002D24SDR REXA2017072600811Oxygen Bottle · brokenPORTABLE O2 BOTTLE KNOB FELL OFF. R&R PORTABLE O2 BOTTLE IAW AMM 35-31-01.Jul 26, 2017 · N311PQ · Cndair CL6002D24SDR REXA2017071400784Oxygen Bottle · emptyONE PORTABLE OXYGEN BOTTLE READS 0 PSI. R & R DEPLETED OXYGEN BOTTLE IAW AMM 35-31-01.Jul 14, 2017 · N927EV · Cndair CL6002B19SDR REXA2017070400770Oxygen Bottle · damagedBROKEN ON & OFF KNOB ON PORTABLE OXYGEN BOTTLE. REPLACED THE PORTABLE OXYGEN BOTTLE IAW AMM 35-30-00.Jul 4, 2017 · N8694A · Cndair CL6002B19SDR CALA2017060201658Oxygen Mask · crackedDURING A CHECK, FOUND PORTABLE OXYGEN MASK DAMAGED. THE MASK WAS REPLACED IAW AMM 35-3 1-00Jun 1, 2017 · N78001 · Boeing 777224SDR REXA2017053100649Hose · damagedPORTABLE OXYGEN BOTTLE, OXYGEN MASK HOSE DAMAGED. REMOVED & REPLACED THE OXYGEN MASK IAW AMM TS 000340R1May 31, 2017 · N8694A · Cndair CL6002B19SDR REXA2017053100646Gauge · damagedENTRANCE AREA OXYGEN BOTTLE HAS DAMAGED GAUGE. REMOVED AND REPLACED PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01.May 31, 2017 · N980EV · Cndair CL6002B19SDR REXA2017050800574Oxygen Bottle · low pressureFLIGHT ATTENDANT PORTABLE OXYGEN BOTTLE BELOW 1500 PSI. MX NOTIFIED. REMOVED AND REPLACED FLIGHT ATTENDANT PORTABLE OXYGEN BOTTLE AND OXYGEN MASK IAW AMM 35-31-01 AND 35-31-04, RESPECTIVELY. O2 BOTTLE P/N ON/OFF 5500-CIA-Y0EE S/N OFF P13102682 S/N ON P14082952May 8, 2017 · N311PQ · Cndair CL6002D24SDR REXA2017050700572Oxygen Bottle · low pressureFWD PORTABLE OXYGEN BOTTLE HAD LOW PRESSURE. REPLACED FWD PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01. ACFT OK FOR SERVICE.May 7, 2017 · N905XJ · Cndair CL6002D24SDR MASA2017042012749Oxygen Bottle · inoperativeAFT PORTABLE O2 BOTTLE VALVE W/N OPEN DURING MEDICAL EMERGENCY. REPLACED BOTTLE.Apr 20, 2017 · N248LR · Cndair CL6002D24SDR REXA2017041400504Oxygen Bottle · emptyDURING WAKE-UP, NOTED FWD PORTABLE OXYGEN CYLINDER. HAD 0 PSI. INSTALLED NEW SERVICEABLE PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01 AND T.S. 00340R1. OPS TESTED GOOD.Apr 14, 2017 · N836AY · Cndair CL6002B19SDR REXA2017040800487Oxygen Mask · tornPORTABLE OXYGEN BOTTLE HAS A TORN MASK. R & R THE OXYGEN MASK IAW AMM 35-31-01 OP CHECKED GOOD.Apr 8, 2017 · N8688C · Cndair CL6002B19SDR REXA2017030200312Oxygen Mask · unserviceablePORTABLE O2 BOTTLE S/N ST 60291 HAS UNSERVICEABLE 4 LPM MASK. REMOVED & REPLACED O2 BOTTLE MASK IAW AMM 35-31-01.Mar 2, 2017 · N8943A · Cndair CL6002B19SDR VQIA2017080900036Oxygen Bottle · failedEXPERIENCED A MEDICAL EMERGENCY WHERE A PAX REQUIRED OXYGEN. ACCORDING TO THE FLT ATTENDANT THE PORTABLE OXYGEN BOTTLE FAILED WITH THE VALVE FULLY OPENED, ALL THE OXYGEN LEAKED OUT.Feb 22, 2017 · N854VA · Airbus A320214SDR REXA2017011700071Oxygen Bottle · brokenTABS TO HOLD HOSE ON PORTABLE OXYGEN BOTTLE BROKE. REMOVED AND REPLACED OXYGEN MASK ON PASSENGER PORTABLE OXYGEN BOTTLE IAW TECHNICAL SUPPLEMENT TS 000755-2013.Jan 17, 2017 · N925XJ · Cndair CL6002D24SDR FDEA201612054326Oxygen Mask · unserviceableCOCKPIT PORTABLE OXYGEN MASK FOUND DRY-ROTTED. REMOVED AND REPLACED COCKPIT PORTABLE OXYGEN MASK IN REF TO AMM 35-30-01-4. ACFT OK FOR SERVICE.Dec 5, 2016 · N365FE · Doug MD1010F
Back to JASC 3530