Service difficulty reports · 272

Reports filed under 3530 · Portable Oxygen System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR REXA2016100101974Oxygen Bottle · inoperativePORTABLE OXYGEN BOTTLE S/N: 184341 FAILED OPS CK. REMOVED & REPLACED PORTABLE OXYGEN BOTTLE S/N 184341 IAW TS000340-2012. C/W OPERATIONAL CHECK IAW AMM 35-31-01-710-801. CHECKS GOOD.Oct 1, 2016 · N8908D · Cndair CL6002B19SDR REXA2016092101805Oxygen Bottle · damagedPORTABLE OXYGEN BOTTLE KNOB BROKEN OFF. REPLACED THE OXYGEN BOTTLE IAW AMM 35-30-00Sep 21, 2016 · N801AY · Cndair CL6002B19SDR REXA2016080201455Oxygen Mask · defective1 EA BLUE 4LPM MASK FAILS LEAK CHECK ON 1 EA PORTABLE OXYGEN BOTTLE. R & R 1 EA 4LPM BLUE OXYGEN MASK IAW TS 000340-2012 & AMM 35-31-01.Aug 2, 2016 · N8839E · Cndair CL6002B19SDR UIEA2016051600296Hose · deformedFOUND PORTABLE OXYGEN CYLINDER MASK HOSE DEFORMED AT L4 AFT CREW REST TOTAL 2 EA. IAW AMM TASK 35-31-00-206-011 REV 86 REPLACED PORTABLE OXYGEN CYLINDER MASK HOSE.May 15, 2016 · N322SG · Boeing 747481SDR REXA2016040600555Oxygen Mask · tangledFORWARD FLIGHT ATTENDANTS MASKS WERE TANGLED & FLIGHT ATTENDANT INDICATES SHE COULD NOT PULL ON THEM TO USE. ALL PAX OXY MASKS DEPLOYED. SEE LOG PAGE 3300044 FOR CORRECTIVE ACTION TAKEN.Apr 6, 2016 · N601LR · Cndair CL6002D24SDR FDEA201512304108Oxygen Mask · unknownSMOKE MASK ON WALK AROUND, BOTTLE FACE MASK OFF. R & R SMOKE MASK IAW SMP. OK FOR SERVICE. ALSO REF AMM 35-30-01-4.Dec 30, 2015 · N609FE · Doug MD11FSDR REXA2015101100924Oxygen Bottle · lowAFT EMER O2 BOTTLE NEEDS TO BE SERVICED, O2 LEVEL AT OR BELOW MINIMUM LEVEL. SERVICED AFT PORTABLE O2 CYLINDER TS 000432-2013.Oct 11, 2015 · N925XJ · Cndair CL6002D24SDR UIEA2015100200565Oxygen Mask · damagedPASSENGER CABIN, FOUR EACH PORTABLE OXYGEN BOTTLE MASKS ARE DAMAGED. R & R DAMAGED PORTABLE OXYGEN BOTTLE MASK IN PAX CABIN AS NEEDED IAW AMM 35-31-00.Oct 2, 2015 · N641GT · Boeing 76738ESDR REXA2015091400861Oxygen Mask · failedONE PORTABLE O2 MASK, RED, FAILED TO INFLATE. R & R ONE PORTABLE O2 MASK, RED, IAW AMM 35-31-01.Sep 14, 2015 · N8970D · Cndair CL6002B19SDR REXA2015070600665Oxygen Mask · damagedDURING 12 MONTH INSPECTION OF PORTABLE OXYGEN BOTTLES, FOUND 4LPM MASK DAMAGED ON OXY BOTTLE SN A2001. R & R 4LPM MASK IAW AMM 35-31-01TS000340-2012.Jul 6, 2015 · N8964E · Cndair CL6002B19SDR REXA2015050900471Oxygen Bottle · low pressureMEDICAL O2 LOW, TANK IN FRONT OF CLOSET. R & R PORTABLE O2 BOTTLE IAW AMM 35-30-00.May 9, 2015 · N8936A · Cndair CL6002B19SDR GTIA2015021001502Oxygen Mask · unwanted deployDURING TAXI OUT, O2 MASK DEPLOYED FROM FWD LAV. OPS CHECKED GOOD IAW AMM 35-23-00.Feb 10, 2015 · N506NK · Airbus A319132SDR CALA2014121692830Oxygen Bottle · unserviceableAFT CABIN LT SIDE BEHIND LAST ROW OF SEATS HAVE BOTH PORTABLE O2 BOTTLE CANNULA TIGHTLY TIE WRAPPED TO BOTTLES RENDERING BOTTLES USELESS. REMOVED TIE WRAPS FROM BOTH BOTTLES & REPLACED UPPER BOTTLE.Oct 12, 2014 · N809UA · Airbus A319131SDR REXA2014092601000Oxygen Bottle · low pressureEMERGENCY MEDICAL PORTABLE OXYGEN BOTTLE IS LOW. REPLACED O2 BOTTLE IAW AMM 35-11-03 DM 008656 CLOSED PLACARD REMOVED.Sep 26, 2014 · N836AY · Cndair CL6002B19SDR YYFA20140923001Oxygen Bottle · low pressureFORWARD OXYGEN WALK AROUND BOTTLE REQUIRES SERVICING.Sep 23, 2014 · N306FA · Doug MD83SDR F3LA2014090801063Bottle · dischargedLOUD NOISE & RUSH OF AIR IN AFT GALLEY AREA RT SIDE OVERHEAD. BLOCK RETURN. FOUND PORTABLE OXYGEN BOTTLE IN AFT CABIN POSITION TO HAVE SUDDENLY DEPRESSURIZED TO ZERO PSI. REPLACED AFT PORTABLE OXYGEN BOTTLE IAW AMM 35-32-42 PAGE BLOCK 401. FLIGHT ATTENDANTSep 7, 2014 · N929FR · Airbus A319111SDR CALA2014062091321Oxygen Bottle · damagedEMPTY O2 BOTTLE AT 1L. BOTTLE HAS BEEN DAMAGED MISSING STRAPS & THREAT PROTECTOR FOR FILL PORT BOTTLE. REMOVED FROM ACFT, REPLACED REMOVED O2 BOTTLE.Jun 19, 2014 · N558UA · Boeing 757222SDR UIEA2014010700002Oxygen Bottle · unserviceablePORTABLE OXYGEN BOTTLE AT POSITION R4 UPPER READS 1600 PSI. R & R O2 BOTTLE IAW AMM 25-31-01.Jan 5, 2014 · N641GT · Boeing 76738ESDR REXA2013112702189Pbe · unserviceableAFT PBE VACUUM SEAL BROKEN. REPLACED AFT PBE PN OFF ON MR10047N IAW AMM 35­31­06.Nov 27, 2013 · N903XJ · Cndair CL6002D24SDR REXA2013112202274Oxygen Mask · missingPASSENGER O2 BOTTLE USED IN FLIGHT & NOW PRESS IS LOW & BLUE MASK IS MISSING. R & R PORTABLE OXYGEN CYLINDER IAW CRJ 200 AMM 35-31-01, AIRCRAFT OK FOR SERVICE.Nov 22, 2013 · N8894A · Cndair CL6002B19SDR CALA2013102392298Clamp · brokenCLAMP ON FIRST CLASS OXYGEN BOTTLE BROKEN.Oct 22, 2013 · N474UA · Airbus A320232SDR CALA2013102192218Oxygen Mask · missingOXYGEN MASK FOR AFT CABIN WALK AROUND BOTTLE MISSING. REPLACED MASK WITH NEW ONE.Oct 19, 2013 · N671UA · Boeing 767322SDR CALA2013101692129Oxygen Bottle · low pressureCREW OXYGEN BOTTLE PRESS BELOW NR 2 SVC LIMITS. REPLACED OXYGEN BOTTLE IAW AMM, CHECKED OKAY.Oct 15, 2013 · N665UA · Boeing 767322SDR CALA2013100991917Oxygen Bottle · low pressureTWO EACH PORTABLE OXYGEN PRESSURE BELOW RED BAND. REPLACED R1 TWO EACH PORTABLE O2 IAW AMM.Oct 8, 2013 · N215UA · Boeing 777222SDR CALA2013092691490Oxygen Bottle · low pressureO2 BOTTLE LOW AT DOOR 4L. REPLACED O2 BOTTLE & MASK.Sep 25, 2013 · N780UA · Boeing 777222SDR UIEA2013081900453Oxygen Bottle · emptyTWO PORTABLE OXYGEN CYLINDERS DEPLEATED. SERVICED OXYGEN CYLINDERS IAW GMM 3-28-3.Aug 19, 2013 · N642GT · Boeing 7673Y0SDR CALA2013081990551Oxygen Bottle · depletedINFANT PORTABLE OXYGEN BOTTLE AT 903 DEPLETED. SERVICED O2 BOTTLE LOCATED AT POS 903. ALL OPS OK.Aug 18, 2013 · N666UA · Boeing 767322SDR UIEA2013080600431Bottle · low pressurePORTABLE OXYGEN BOTTLE AT 1000 PSI AT MID CABIN LT SIDE MIDDLE BOTTLE. R & R OXYGEN BOTTLE IAW AMM 35-31-01.Aug 5, 2013 · N767MW · Boeing 767277SDR CALA2013073090094Indicator · damagedIN STOW BIN 1AB, O2 BOTTLE AND O2 BOTTLE NEXT TO AFT FWD LAV, HAVE INDICATION PRESSURE NEEDLES BENT OVER TO INDICATE FULL. REPLACED BOTH O2 BOTTLES.Jul 27, 2013 · N537UA · Boeing 757222SDR UALA2013071805037Oxygen Bottle · emptyOXYGEN BOTTLE EMPTY. REPLACED.Jul 17, 2013 · N496UA · Airbus A320232SDR UALA2013071204866Oxygen Bottle · emptyR5 DOOR OXYGEN BOTTLE READS 0 PSI. REPLACED O2 BOTTLE.Jul 11, 2013 · N180UA · Boeing 747422SDR UALA2013062604459Oxygen Mask · missingOXYGEN MASK MISSING FROM OXYGEN BOTTLE OVER 1A. REPLACED OXYGEN MASK ON OXYGEN BOTTLE.Jun 25, 2013 · N418UA · Airbus A320232SDR REXA2013060201039Pbe · damagedPBE IS DAMAGED. R & R COCKPIT PBE IAW AMM 35-30-00. NO FURTHER DEFECTS NOTED. ACFT OK FOR SERVICE.Jun 2, 2013 · N8968E · Cndair CL6002B19SDR UALA2013053003783Bottle · missingOXYGEN BOTTLE MISSING. REPLACED BOTTLE.May 28, 2013 · N511UA · Boeing 757222SDR REXA2013052500917Seal · brokenCAPTAINS PBE GREEN SEAL CLIP BROKEN. REPLACED SEAL, PBE CHECK OK IAW AMM 35-30-00.May 25, 2013 · N8771A · Cndair CL6002B19SDR REXA2013050700875Pbe · unserviceableCOCKPIT PBE TORN OPEN. REMOVED AND REPLACED PBE IAW AMM 35-30-00.May 7, 2013 · N8836A · Cndair CL6002B19SDR UALA2013040302186Oxygen Bottle · low pressureONE O2 BOTTLE PRESSURE LOW AT 4R. NO TIME TO SERVICE, DF PER MEL. REPLACED O2 CYL FULL WITH MASK.Apr 1, 2013 · N182UA · Boeing 747422SDR UALA2013032701944Oxygen Bottle · missingOXYGEN BOTTLE MISSING, AFT CABIN. SERVICED O2 PRESSURE. OK FOR SERVICE.Mar 26, 2013 · N449UA · Airbus A320232SDR UALA2013032501857Oxygen Bottle · missingOXYGEN BOTTLE MISSING, REPLACED CYLINDER.Mar 24, 2013 · N488UA · Airbus A320232SDR UALA2013032501843Oxygen Bottle · emptyO2 BOTTLE ABOVE 34C DEPLETED. REPLACED PORTABLE O2 BOTTLE ABOVE 34C IAW GMM. REPLACED MASK. OK TO CONTINUE.Mar 23, 2013 · N852UA · Airbus A319131SDR UALA2013031801647Oxygen Bottle · low pressure2L OXYGEN BOTTLE PRESSURE LOW. REMOVED AND REPLACED OXYGEN BOTTLE AT DOOR 2L. OK TO CONTINUE FOR SERVICE. .Mar 17, 2013 · N672UA · Boeing 767322SDR UALA2013031501579Oxygen Bottle · dischargedOXYGNE BOTTLE DISCHARGED. REPLACED OXYGEN BOTTLE AMM.Mar 15, 2013 · N214UA · Boeing 777222SDR UALA2013022601144Bottle · faultyOXYGEN BOTTLE MISSING - USED AT LOCATION NOT SPECIFIED CREW COMMENTS: ONE O2 BOTTLE USED AND ONE THE KNOB TO START THE FLOW OF O2 WOULD NOT TURN. REPLACED BOTH O2 BOTTLES.Feb 25, 2013 · N815UA · Airbus A319131SDR R61A201302190169Pbe · damagedCREW REPORTED PBE DAMAGED. MAINTENANCE REMOVED AND REPLACED AFT LEFT PBE PER BOMBA AMM. NO DEFECTS NOTED.Feb 19, 2013 · N502LX · Bombdr DHC8402SDR UALA2013021800965Oxygen Bottle · low pressurePSX PORTABLE OXYGEN CYLINDER(S) PRESS IS LOW OR ZERO (AT 01 LOCATIONS). AFT LEFT DOOR REPLACED AFT POB.Feb 15, 2013 · N665UA · Boeing 767322SDR UALA2013010700106Oxygen Bottle · low pressureO2 BOTTLE HAS LOW PRESSURE. REPLACED O2 BOTTLE.Jan 7, 2013 · N827UA · Airbus A319131SDR UALA2012122107363Bottle · low pressureAFT O2 BOTTLE WAS USED PRESSURE IS LOW. PRESSURE IS LOW. REMOVED BOTTLE AND INSTALLED STICKER TO BRACKET.Dec 20, 2012 · N571UA · Boeing 757222SDR UALA2012121407225Oxygen Mask · unknownFWD CABIN SMALL O2 BOTTLE MASK NEEDS TO BE REPLACED. REPLACED O2 MASK AS REQUIRED.Dec 12, 2012 · N528UA · Boeing 757222SDR UALA2012101705930Oxygen Mask · faultyOXYGEN BOTTLE MISSING-USED AT 37A. OXYGEN PRESSURE WAS GOOD. MASK WAS BAD. REMOVED AND REPLACED 02 MASK.Oct 16, 2012 · N436UA · Airbus A320232SDR UALA2012101505881Oxygen Mask · unknownTHE 3L PORTABLE O2 MASK NEEDS TO BE REPLACED. REPLACED MASK.Oct 14, 2012 · N213UA · Boeing 777222
Back to JASC 3530