JASC 3530
Service difficulty reports · 272
Reports filed under 3530 · Portable Oxygen System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012101105777Bottle · missingOXYGEN BOTTLE MISSING, USED AT R2 DOOR. REPLACED CYLINDER.SDR UALA2012100305609Oxygen Bottle · missingOXYGEN BOTTLE MISSING USED AT AFT CABIN. REPLACED BOTTLE AND O2 MASK.SDR HALA2012082800214Oxygen Bottle · depletedSMALL O2 WALKAROUND BOTTLE AT 3H STORAGE COMPARTMENT EMPTY, COMPLETE DISCHARGE AT 41000 FT. R & R PORTABLE OXYGEN CYLINDER ASSY AND REPLACE WITH SERVICABLE ASSY IAW AMM 35-32-42, PG 401. INBOUND LOCATION AT 3H STORAGE COMPARTMENT. OK FOR SERVICE.SDR FDEA201208243149Oxygen Bottle · lowPERFORMED TRANSIT CHECK. PORTABLE CREW OXYGEN BOTTLE LOW. REQUIRES REPLACEMENT. R & R FLIGHT CREW PORTABLE OXYGEN BOTTLE OPS NORMAL IAW MM35-30-000-0-0. R/I FROM FACT PREMATURE REMOVAL/INSTALLATION. R & R FLIGHT CREW PORTABLE OXYGEN BOTTLE OPS NORMAL IAWSDR UALA2012081304435Oxygen Bottle · low pressureFIRST CLASS O2 BOTTLE GAUGE SHOWS LOW PRESSURE. REPLACED O2 BOTTLE.SDR USAA2012072300020Oxygen Bottle · depletedAFT OXYGEN BOTTLE DEPLETED. REPLACED PORTABLE OXYGEN BOTTLE WITH SERVICEABLE UNIT.SDR ASOA20120718122Line · brokenDIVERTED. DISCOVERED AFT PORTABLE O2 BOTTLE HAD A PARTIALLY CRACKED & BROKEN LINE FROM THE BOTTLE TO THE MASK.SDR UALA2012070903679Oxygen Mask · detachedO2 BOTTLE ABV SEAT 37E, MASK IS NOT ATTACHED. REPLACED O2 BOTTLE.SDR UALA2012051802822Oxygen Bottle · emptyOXYGEN BOTTLE FOUND EMPTY AT DOOR 5R. SERVICED BOTTLE AND MASK REPLACED.SDR FDEA201205171826Oxygen Mask · damagedDURING PRE-FLIGHT, FOUND PORTABLE O2 MASK HAD A HOLE IN THE HOSE. INSTALLED NEW OXYGEN MASK IAW MM 35-30-000-0. OK FOR SERVICE.SDR UALA2012043002544Oxygen Bottle · usedLARGE O2 BOTTLE 5AB USED, REPLACED O2 ROW 5A.SDR UALA2012043002543Oxygen Bottle · usedSMALL O2 BOTTLE USED FROM ROW 20ABC, REPLACED O2 ROW 20A.SDR UALA2012043002539Oxygen Bottle · failedOXYGEN BOTTLE MISSING, USED AT AFT CABIN, FWD CABIN FLIGHT ATTENDANT REPORTED THAT THE OXYGEN BOTTLE WAS FULL BUT FAILED TO PROVIDE OXYGEN TO PASSENGER. REPLACED OXYGEN BOTTLE AT AFT CABIN.SDR REXA2012041000490Pbe · damagedPBE IN COCKPIT APPEARS VIOLATED. DISK IS NOT LIGHT BLUE BUT DARK IN COLOR. BAG IS NO LONGER VACUUM SEALED AND RED DUCK TAPE IS NO LONGER HOLDING SECURELY AROUND BAG. REMOVED AND REPLACED CREW PBE IAW ESSEX CREW PBE CMM. OK FOR SERVICE.SDR REXA2012040900495Bottle · lowPAX EMERGENCY O2 LOW. SERVICED PORTABLE OXYGEN BOTTLE IAW AMM 35-31-01. ACFT OK FOR SERVICE.SDR REXA2012040800485Pbe · damagedCOCKPIT PBE IS MUSHY AND INDICATOR IS NOT LIGHT BLUE. REMOVED & REPLACED COCKPIT PBE IAW CMM PRM-01 AND AMM 35-30-00, OK FOR SERVICE.SDR USAA2012032900011Mask · missingSMOKE MASK MISSING. MAINTENANCE REPLACED SMOKE MASK AS REQUIRED.SDR UALA2012031401671Bottle · defectiveFOUND 3 EACH PORTABLE O2 BOTTLES NOT CONNECTED TO O2 MASK. ONE IN FRONT HAD CANNULA STRAPPED TO IT. THE TWO BACK HAD NO MASK CONNECTION AND GREEN ELBOWS WERE ALL INSTALLED BACKWARDS. INSTALLED AND CORRECTED ALL DISCREPANCIES ON PORTABLE O2 BOTTLES IN CABIN.SDR UALA2012030501336Oxygen Bottle · missingOXYGEN BOTTLE MISSING-USED AT VID-MONITOR MID-CBN CTR NR 1. 3 OXYGEN BOTTLES USED FROM AFT COACH :DISTRIBUTED BOTTLES EVENL Y TO ALL THREE STATIONS, PLACED DF STICKERS ON BOTTLE BRACKETS AND PLACED STICKER DF ON EMPTY BOTTLES, EMPTY BOTTLES LOCATED AT 1AB , 2SDR USAA2012020800016Oxygen Bottle · brokenFOUND MID LEFT SIDE PORTABLE OXYGEN BOTTLE GAUGE BROKEN. REPLACED PORTABLE OXYGEN BOTTLE.SDR DALA1201360911Battery Pack · dischargedDURING LINE CHECK, MAINTENANCE FOUND THAT THE EMERGENCY PATHWAY LIGHTING IN THE VENTRAL STAIRWAY WERE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACKS (B-25-28 & B5-27) AND THE LIGHTS RETURNED TO AN OPERATIONAL CONDITION.SDR UALA2011122707121Oxygen Bottle · missingOXYGEN BOTTLE MISSING. REPLACED OXYGEN BOTTLESDR MASA2011122364259Oxygen Bottle · low pressurePORTABLE O2 BOTTLE LOW AT 1000 PSI. SERVICED TO 1800 PSI.SDR SIMA201134801Oxygen Bottle · defectiveON FLIGHT 4387 THE CREW REPORTED A PASSENGER’S PORTABLE OXYGEN BOTTLE WAS OPERATING AT AT 1100 PSI. THE CREW ELECTED TO DECLARE AN EMERGECNY AND DIVERT TO CRW. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACESDR UALA2011112906560Oxygen Mask · defectivePORTABLE OXYGEN BOTTLE MASK DEFECTIVE - OXYGEN CREW COMMENTS: AFT BOTTLE MISSING FACE MASK, HAS CANULA. REPLACED AND SECURED.SDR UALA2011110305959Latch · brokenOXYGEN BOTTLE STORAGE BIN DREW LATCH BROKEN AND WONT STAY CLOSED. RT SIDE FORWARD OF COAT CLOSETS. EMERGENCY EQUIPMENT IS ALSO DEFFERED. COMPLIED WITH MEL. REPLACED LATCH ASSY AND FACE PLATE ASSY. OP'S CHECK NORMAL.SDR UALA2011100305352Oxygen Mask · missingO2 MASK MISSING FOR PORTABLE O2 BOTTLE AT DOOR 1L. REPLACED MASK.SDR MASA2011091663696Oxygen Bottle · emptyAFT PORT O2 BOTTLE EMPTY. R2 PORTABLE O2 BOTTLE.SDR MASA2011091563692Oxygen Bottle · emptyAFT PORT O2 BOTTLE EMPTY. R2 PORTABLE O2 BOTTLE AND REGULATOR ASSY.SDR UALA2011082504553Oxygen Bottle · dischargedO2 BOTTLE USED DOOR 1L *FIX JP :TO DF FOR REPLACEMENT. MEL 3531J APPLIED REPLACED O2 BOTTLE.SDR UALA2011080804143Oxygen Bottle · odorMID GALLEY RIGHT AISLE ELECTRICAL BURNING SMELL. SMELL GETS STRONGER THEN DISSIPATES. RAN ALL OVENS, RE-HEATERS, LIGHTS, VIDEOS, AND CHILLERS. NO BURNING SMELL NOTED. CHECKED LAV WATER HEATERS. CH'D ALL CB'S NONE TRIPPED. CHECKED CLOSET LIGHT AND OVERHEADSDR ABXA2011051251Pbe · unserviceablePBE LOST VACUUM SEAL. DEF DI 68682 CODE 27 DEFERRED IAW GMM & B767-2A PLACARD INSTALLED.SDR UALA2011042502017Oxygen Bottle · low pressurePSX PORTABLE OXYGEN CYLINDER(S) PRESS IS LOW OR ZERO. CREW COMMENTS: BOTTLE AT 2R USED. DF O2 BOTTLE INOP AT DOOR 2R DUE TO NO SPARE IN FRA. REPLACED O2 BOTTLE.SDR UALA2010102503935Oxygen Mask · defectivePORTABLE OXYGEN BOTTLE MASK DEFECTIVE - OXYGEN. O2 MASK MISSING OR USED ROW 24ABC. MASK APPEARS TO BE USED, OXY BOTTLE CONSIDERED INOP PER MEL. RPL'D O2 MASK. BOTTLE WAS NORMAL.SDR SIMA201028101Pbe · unserviceableFOR FLIGHT 3498 THE FLIGHT ATTENDANT REPORTED THE FORWARD PERSONAL BREATHING EQUIPMENT SEAL TO BE BROKEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE PERSONAL BREATHING EQUIPMENT WITH ESSEX PBE IAW EO CR-2500-080 R1 PT D. THE AIRCRAFT WASDR UALA2010090703287Oxygen Bottle · lowCABIN PORTABLE OXYGEN BOTTLE AT SEAT 26ABC, LOW PRESSURE INDICATION. REPLACED WITH NEW BOTTLE.SDR AMCR201008Mask · wrong partFOUND PORTABLE O2 MASK TO BE THE INCORRECT TYPE. EVEN THOUGH CUSTOMER BULLETIN 213 DID NOT LIST THIS ACFT IN THE EFFECTIVITY SECTION, AN INSP REVEALED THE WRONG MASK ANYWAY. ANOTHER BAD MASK WAS FOUND ON ANOTHER ACFT IN THE FLEET ALSO NOT LISTED IN THE BULLETISDR SIMA201021401Pbe · unserviceableDURING MAINTENANCE BASE VISIT FOUND THE FORWARD CABIN PERSONAL BREATHING EQUIPMENT HAD LOST ITS VACUUM SEAL. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE FORWARD CABIN PERSONAL BREATHING EQUIPMENT AS REQUIRED AND IN REFERENCE EO CR-2500-08SDR SIMA201016701Pbe · unserviceableDURING MAINTENANCE BASE VISIT FOUND THE AFT CABIN PROTECTIVE BREATHING EQUIPMENT VACUUM SEAL TO BE BROKEN. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE AFT CABIN PROTECTIVE BREATHING EQUIPMENT. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR ASOA201000511Oxygen Bottle · lowUSED PORTABLE O2 BOTTLE TO BELOW LIMITS, 2ND BOTTLE WOULD NOT WORK. SERVICED BOTH PORTABLE O2 BOTTLES IAW CMM 35-31-01. OK FOR SERVICE.SDR AALA20100114MIA02Oxygen Bottle · low pressurePORTABLE OXYGEN BOTTLE LOW AT OVERHEAD SEAT 41GFDC. REPLACED PORTABLE O2 BOTTLE AT OVERHEAD SEAT 41G, F, D, C.SDR UALA2009061501684Oxygen Bottle · low pressureDOOR 2R O2 BOTTLE LOW PRESSURE. REPLACED O2 BOTTLE.SDR C2XA09SH010Oxygen Bottle · brokenAFT PORTABLE OXYGEN CYLINDER HAS BROKEN KNOB. R&R AFT OXYGEN BOTTLE IAW EMB 145 XR AMM 35-30-01. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR 2008UALA06340Oxygen Bottle · misinstalledALL PORTABLE O2 CYLINDERS IMPROPERLY STOWED. STRAPS ARE CAUGHT UNDER CLAMPS. SECURED O2 BOTTLES.SDR 2008UALA06247Oxygen Bottle · low pressureTHE O2 BOTTLE LOW AT FIRST CLASS LOCATION. REPLACED O2.SDR MASA200800440Oxygen Bottle · dischargedASH FLT 1906 HNL-LIH. PORTABLE O2 BOTTLE AT ZERO PSI. MX REPLACED THE PORTABLE O2 BOTTLE ASSEMBLY.SDR AALA200801380Oxygen Bottle · lowMIA - EMERGENCY OXYGEN BOTTLE AT LT NR TWO DOOR PRESSURE LOW. REPLACED OXYGEN BOTTLE AT LT NR TWO DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (A)SDR 2008UALA02872Oxygen Bottle · lowFOUND PORTABLE OXYGEN BOTTLE LOW AT SEAT ROW 26 ABC. REPLACED O2 BOTTLE.SDR UPS08852001Seal · missingINSPECTION TYPE:N/A CREW PBE MISSING THE UPPER GREEN LOCKED SEAL. REPLACED LOCK SEAL.SDR MASA200800218Pbe · openASH FLT 7149 IAD-BNA - CAPTAIN’S PBE WAS OPENED. MX REPLACED THE PBE.
Back to JASC 3530