SDR VNAA0404014Switch · failedAFTER LANDING, ANTI ICE DUCT WARNINGS ILLUMINATED THEN CLEARED. AIRCRAFT WAS FERRIED TO DAY WHERE MAINTENANCE INSPECTED AND REPLACED WING LEADING EDGE THERMEL SWITCHES IN ACCORDANCE WITH BOMBARDIER MAINTENANCE MANUAL 36-21-07-710-801. OPERATIONAL CHECKS WERESDR AUS20040310Manifold · cracked(AUS) LT ENGINE HP SERVO PRESSURE SUPPLY TUBE TO MANIFOLD WELDED JOINT CRACKED.SDR AMTA200400440Controller · malfunctionedON TAKEOFF LT ENGINE BLEED OFF LIGHT ILLUMINATER. RESET UPON ARRIVAL AT KMDW SYSTEM NORMAL . REMOVED AND REPLACED REVERSE FLOW CHECK CONTROLLER IAW AMMSDR AUS20040258Valve · faulty(AUS) LT ENGINE PRESSURE REGULATING VALVE (PRV) FAULTY.SDR 2004UALA00306Bleed Valve · failedRETURNED TO FIELD DUE TO FAILED BLEED VALVE. FAN AIR VALVE CONTROL THERMOSTAT FAILED. REPLACED FAN AIR VALVE CONTROL THERMOSTAT. OPERATIONS CHECK NORMAL.SDR CA040405AAADuct · ruptured(CAN) FLIGHT CREW REPORTED A RUMBLE NOISE HEARD FROM COCKPIT AND CABIN CONTINUOUSLY WITH BLEED AIR / AIR CONDITIONING. UNABLE TO ISOLATE WITH AIR CONDITIONING PACKS. DURING INVESTIGATION, MAINTENANCE FOUND THE GROUND AIR CONDITIONING DUCT ( COMPOSITE ) RUPTURESDR 04FDEA00763Clamp · looseON CLIMBOUT BETWEEN 5000 FT AND 10,000 FT, NR 2 ENG ANTI-ICE DUCT LEVEL 3 ALERT ILLUMINATED. QRH PROCEDURES FOLLOWED, RETURNED TO KMEM. LEVEL 3 WARNING DISAPPEARS AFTER THROTTLES RETURNED TO IDLE POWER. EMERGENCY EQUIPMENT REQUESTED, LANDING UNEVENTFUL. SDR AMTA200400333Clamp · looseLT ENGINE OVERHEAT EICAS MESSAGE AT FL420, OVERHEAT INDICATION REMAINED WITH THROTTLE CLOSED, BAV CLOSED FOR APPROX 2 MINUTES EXTINGUISHED AND DID NOT REOCCUR AT ANY POWER SETTING. TROUBLESHOT PER FIM 26-11-00 FIG 103. FOUND CLAMPS LOOSE ON IP AND HP BLEED DSDR MASA200400151O-Ring · blownDIVERTED TO CLT DUE TO BLEED NR 2 LEAK MSG IN-FLIGHT. MX REPLACED A BLEED DUCT GAMMA COUPLING O-RING AND THE SYSTEM OP CHECKED GOOD.SDR C2XA04TY053Tube · looseTYS DURING CLIMBOUT THE CREW GOT A INDICATION THAT THE NR 1 ENG HAD A BLEED LEAK AND RETURNED TO THE BLOCK. MAINT FOUND A LOOSE BURST DETECT LINE ON THE LT LEADING EDGE. TIGHTENED IAW EMB135/145 MM 20-10-03. PERFORMED AIRBLEED OPS CHECK IAW 145 AMM 36-00-0SDR COMA0460197Duct · blownFLIGHT 5200 RIGHT 14TH STAGE DUCT LEAK WARNING. FOUND 14TH STAGE BLEED DUCT BLOWN APART. REPLACED DUCT.SDR P5CA0401053Seal · brokenLEFT WING L/E OVERHEAT LIGHT ON. REPLACED BROKEN SEALS ON L/E DUCT INBOARD OF NR 2 ENG AND BY THE NR 3 PDU OPS AND LEAK CHECK OK PER MM 36-11-01 AND 26-18-01.SDR P5CA0401051Relief Valve · illuminatedAT APPROX 6,000 FT NR 4 ENG LOOP FAULT LT ILLUMINATED NACELLE TEMPS A&B OBSERVED RAPIDLY CLIMBING TO 9. REMOVED AND REPLACED HIGH PRESS VLV, HIGH PRESS BLEED VLV HARNESS. REMOVED AND REPLACED PRESSURE RELIEF VLV. ENG OPS CHECKED GOOD, NO DEFECTS NOTED PER MSDR ASMF200403002Clamp · leakingDURING TRANSIT CHECK WAS DETECTED HIGH TEMPERATURE ON TAIL CONE. AIRCRAFT WAS SENT TO THE HANGAR AND DURING OVERNIGHT SERVICE AUGMENTATION VALVE AND REGULATOR PRESSURE VALVE CLAMPS WERE REPLACED IAW MM 20-10-11, GASKET AND NIPPLE OF 13A STAGE BLEED VALVE WERSDR AUS20040152Duct · cracked(AUS) NR 2 BLEED AIR SYSTEM BIFURCATED DUCT CRACKED IN AREA OF SUPPORT ATTACHING BRACKET ADJACENT TO THE PRSOV. CRACK LENGTH APPROXIMATELY 25MM (0.984IN).SDR MALA040217Periseal · leakingLEFT BLEED AIR LEAK LIGHT ILLUMINATED IN FLIGHT, HIGH PRESS BLEEDS WERE OFF AT THE TIME. REMOVED AND REPLACED LT FLAP COVE DUCT PERI SEALS IAW SF340MM 36-10-00. PERFORMED OPERATIONAL TESTS IAW SF340MM 36-23-00-5. NO DEFECTS NOTED AT THIS TIME.SDR QXEA200400164Control Valve · malfunctionedSEA - FLIGHT 2454 DIVERSION TO PDX ON FLIGHT FROM SEA TO SBA LEFT HAND BLEED AIR VALVE CYCLES. REPLACED THE LOAD CONTROL VALVE. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR RAIA00402017Seal Ring · leakingSTL - RIGHT ENGINE BLEED LEAK. MAINTENANCE REMOVED AND REPLACED BLEED LINE SEAL UNDER CARGO BAY FLOOR.SDR COMA0470016Control Valve · malfunctionedFLIGHT 5073 LEFT COWL ANTI ICE AND LEFT BLEED CAUTION MESSAGE. REPLACED THE TEMP CONTROL VALVE.SDR SWIA200412861Shutoff Valve · malfunctionedSMOKE IN COCKPIT AND CABIN WITH BOTH PACKS OFF. REMOVED AND REPLACED LT ENGINE PRESSURE REGULATOR SHUT OFF VALVE WITH SERVICEABLE UNIT IAW MM 36-10-04. OPS CHECKS GOOD AT THIS TIME.SDR AUS20040061Valve · faulty(AUS) PNEUMATIC SYSTEM SHUTOFF VALVE FAULTY. LIMITED INFORMATION PROVIDED.SDR CHQA000434Coupling · separatedDURING CLIMBOUT OF CMH PASSING THROUGH 3000 FT, ENTERED ICING CONDITIONS, ANTI-ICE SYSTEM CAME ON AND HEARD A LOUD THUD SOUND. BLD 2 LK APPEARED ON EICAS AND DID NOT GO OUT. SHUT NR 2 ENGINE DOWN IN FLIGHT. FLIGHT ATTENDANT ADVISED, SMELLED BURNING ODOR. DSDR 2004F00289Transducer · malfunctionedFLT LR622 - DURING CRUISE, BOTH ENGINES BLEED SYSTEMS FAULT ECAM WARNING CAME ON. BOTH BLEED SYSTEMS WENT TO CLOSED POSITION AND THE AIRCRAFT RETURNED TO SAL STATION. AFTER LANDING, INSPECTION WAS PERFORMED TO THE BLEED SYSTEM AND REPLACED ENGINE NR 1 TRANSDSDR C2XA04BT010Line · brokenCREW REPORTED, BLEED LEAK IN FLIGHT, LOUD DECOMPRESSION, AND ODOR OF SMOKE FROM NR 2 ENGINE. PERFORMED EMERGENCY LANDING IN NEWARK, AIRCRAFT LANDED UNEVENTFULLY. DURING TROUBLESHOOTING MAINTENANCE FOUND BLEED AIR TUBING ASSEMBLY WHICH CONTROLS NR 2 ENGINE THSDR DLM88040066Duct · rupturedTEN MINUTES AFTER TAKEOFF GOT RIGHT ENGINE FIRE WARNING WITH BELLS, AURAL WARNING, AND LIGHT IN HANDLE. PER PROCEDURE REDUCED THROTTLE TO IDLE ALL INDICATION CEASED AT 1.30 EPR. OTHER INSTRUMENTS NORMAL, NO VIBRATIONS. REPLACED 13TH STAGE ANTI-ICE DUCT ON RISDR DL738040061Control Valve · failedON CLIMBOUT, OUT OF 800 FT RIGHT BLEED TRIP OFF LIGHT ILLUMINATED. WOULD NOT RESET. FOUND RIGHT ENGINE PRE-COOLER CONTROL VALVE FAILED. REPLACED VALVE.SDR MASA200400038Clamp · looseAIRCRAFT DIVERTED TO PIT FOR AN E-2 BLEED LEAK MSG. MX WAS CALLED AND TIGHTENED A LOOSE CLAMP. OP CHECKS GOOD. NO PARTS USED.SDR 2004F00330Clamp · looseFLT CREW REPORTED, AFTER ROTATION, RT DUCT PRESSURE EXCEEDED 100 PSI, ALSO WITH NR 3 ENG BLEED CLOSED FOR APPROX 2 MIN NR 3 ENG STRUT OHEAT LIGHT ILLUMINATED, CREW RETARDED THROTTLE & LIGHT STAYED ILLUMINATED. CREW RETURNED & MADE AN UNEVENTFUL OWEIGHT LANDINSDR UIEA200400004Clamp · brokenLEFT WING OVERHEATED TWICE ON CLIMB-OUT AND THEN IN CRUISE. COMPLETED CHECKLIST TO ISOLATE LEFT WING WITH ONLY NR 2 ENGINE PYLON VALVES OFF, AND ISOLATION VALVE OPEN. FOLLOWING CLIMB FL320 TO FL350 WITH NR 1 AND NR 2 ENGINES BLEED VALVES CLOSED AND LEFT AND SDR MASA200400026Duct · separatedASH 6443 PHX, AIRCRAFT ABORTED TAKEOFF AND RETURNED TO GATE DUE TO A 14TH STAGE BLEED WARNING AND TAKEOFF CONFIG WARNING. MX FOUND DUCT BLOWN OFF AND RIGHT PYLON LOOP BAD. MX REPLACED DUCTING AND LOOP. OP CHECKS GOOD.SDR MASA200400024Control Unit · inoperativeASH 6412 PHX. RETURNED TO FIELD. RT ENGINE 14TH STAGE BLEED DUCT WARNING MSG. A/C RETURNED TO FIELD. MX REPLACED THE BLEED LEAK CONTROL UNIT. OP CHECKS GOOD.SDR RAIA00401002Seal · blown5673-STL- BLEED 2 LEAK INDICATION. MAINTENANCE REMOVED AND REPLACED BLEED LINE SEAL UNDER AFT CARGO FLOOR.SDR RAIA00401003O-Ring · blownBLEED NR 2 LEAK INDICATION. MAINTENANCE REMOVED AND REPLACED RT BLEED DUCT O-RING IN AFT CARGO BAY.SDR P5CA0401018Warning Light · false activationEICAS BLEED NR 4 OVERHEAT / PVT MESSAGE DISPLAYED AFTER START. TRANSFERRED ITEM TO DMI 32027 PER DDG MEL 36-11-8B THRUST REVERSER TRANSFERRED TO DMI 32028 PER DDG MEL 78-31-01.SDR P5CA0401019Duct · leakingBLEED AIR LEAK, APU SUPPLY DUCT AFT OF BULK CARGO COMPARTMENT. ITEM TRANSFERRED TO DMI 32017 AND MEL 49-01-01 PER DDPG.SDR 2004F00291Clamp · looseFLT 829 - TTPP-SYCJ, FLIGHT CREW REPORTED, OVERHEAT ENGINE STRUT 3 ILLUMINATED AFTER TAKEOFF, JETTISONED FUEL, 9000 LBS. FLIGHT CREW DIVERTED AIRCRAFT BACK TO TTPP AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE TROUBLESHOOTING AND INSPECTION REVEALED AN PNSDR 2003UALA00980Clamp · looseUPON LEVEL OFF AT FL340 RECIEVED A RT BLEED DUCT LEAK EICAS MESSAGE. DUCT LEAK BITE PRODUCED STORED FAULT 64 (RT WING LEADING EDGE - BOTH LOOPS IN ZONE BAD) . ERASED CODE FROM MEMORY & CLEARED STATUS MSG. FOUND BLEED DUCT CLAMP IN THE RIGHT LEADING EDGE TO SDR RAIA00312324Pressure Switch · inoperativeSTL- AIR BLEED FAULT. MAINTENANCE REMOVED AND REPLACED PRESSURE SWITCH.SDR MALA030556Duct Seal · failedDURING FLIGHT 3441, RIGHT ZONE HI TEMP ANNUNCIATOR CAME ON AT FLIGHT LEVER 350. AIR RETURN TO MSP. MAINTENANCE REPLACED Y-DUCT SEALS ON LEFT Y-DUCT AS REQ P/N 706-3-250 REF 409 215043 & CONT CARD 096333 FOR DETAILS.SDR DL757031092Shutoff Valve · failedON TAKEOFF GOT LT ENG BLEED ALERT ON EICAS, AND OFF LIGHT ON OVERHEAD BLEED PANEL. REPLACED LEFT PRSOV.SDR P5CA0301006Valve · stuckNR 1 ENG HUNG START AT 28-29 PERCENT N2. FOUND PYLON VALVE STUCK OPEN, CYCLED SAME ENG START NORMAL.SDR WRNA200300014Check Valve · faultyNR 2 ENGINE HAD SEVERE VIBRATION ON DESCENT FROM 29,000 FT. ENGINE PARAMETERS WERE ALL OK EXCEPT N1 NR1 85 PERCENT, NR 2 60 PERCENT VIBRATION STOPPED WHEN THROTTLE BOUGHT BACK BELOW 53.5 PERCENT. FUEL DUMPED. NORMAL LANDING. TROUBLESHOT TO FAULTY IP CHECK VSDR RAIA00312306O-Ring · wornSTL- BLEED 2 LEAK INDICATION. MAINTENANCE REMOVED AND REPLACED O-RING IN CARGO AREA RT SIDE.SDR RAIA00312300O-Ring · worn5663-STL- BLEED 1 LEAK INDICATION. MAINTENANCE REMOVED AND REPLACED FWD SEAL UNDER CARGO FLOORING.SDR RAIA00312297O-Ring · wornSTL- BLEED 2 LEAK INDICATION. MAINTENANCE REMOVED AND REPLACED O-RING IN CARGO AREA UNDER FLOOR RIGHT SIDE.SDR GLBA20030508Tube · failedLT BLEED AIR FAILED, REMOVED AND REPLACED BLEED TUBE PN 129-910033-15.SDR P5CA0301001Warning Light · illuminatedNR 4 ENG START BLEED 4 OVERHEAT / PRV MESSAGE STATUS MESSAGE BLEED PRV4. TRANSFERRED TO DMI 31879, MEL 36-11-86 CAT C. ALSO NR 4 REVERSER DEACTIVATED PER MEL REQUIREMENTS.SDR GLBA20030506Tube · failedLT BLEED FAIL, REPAIRED EVA TUBING PN 131823E6M02060.SDR DL757031055Duct · burstBLEED AIR Y-DUCT IN RT A/C BAY BURST CAUSING PNEUMATIC AIR ACCESS DOOR TO BE RIPPED FROM ITS HINGES DEPARTING ACFT. REPLACED DUCT AND DOOR.SDR MWEA030459Isolation Valve · not openedISOLATION VALVE WOULD NOT OPEN TO START ENGINE. PERFORMED FAULT ISOLATION TEST, NO FAULTS NOTED. OPERATIONS CHECK GOOD.
Back to JASC 3610