Service difficulty report · Control Valve · Cndair CL6002C10

Difficulty date
February 22, 2004
Submitted
February 24, 2004
Operation
Air carrier
Aircraft
N607QX
Make and model
Cndair CL6002C10
Aircraft serial
10024
Aircraft time
5,942 hours, 4,533 cycles
Part
Control Valve
Part number
32912104
Part serial
326
Condition
Malfunctioned
Location
Bleed Air Sys
Part time
5,179 hours, 3,179 cycles
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found