JASC 3800
Service difficulty reports · 227
Reports filed under 3800 · Water and Waste System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3800' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3800' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202312116892Faucet · detachedAIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: LAVATORY FAUCET CAME OFF, UNCONTROLLABLE WATER SPRAYING EVERYWHERE. AIRCRAFT DIVERTED AND LANDED SAFELY AT MEM WITHOUT FURTHER INCIDENT. INSTALLED NEW FAUCET IN LEFT AFT LAVATORY CHECK AND LEAK CHECKSDR CALA2023120703580Valve · stuckAFT RIGHT LAV INOP RUNS CONTINUOUSLY COULD NOT DUPLICATE FAULT ON GROUND,, ITEM IS NIS IN EWR, DEACTIVATED LAV M IAW AMM 38-32-00-042-022, PULLED CANNON PLUG ON ASSEMBLY AS REQUEST BY TOMC **THIS ITEM IS CHRONIC. PREVIOUS WRITEUPS ARE FOR EITHER SPRAY BUT NO FSDR CALA2023102503172Drain · cloggedFOUL SMELLING LIQUID FROM LAV LEAKING INTO FWD GALLEY FWD GALLEY SINK DRAIN CLOGGED AND THE DRAIN STRAINER IS LEAKING FORM 46.6020 FILLED OUT BY CREW -- SEE ALL PHOTO,S INSIDE 109 WITH STANDING WATER -- SEE PHOTO,S REMOVED AND REPLACED FWD GALLEY DRAIN BASKET SDR AALA202310238601Water Heater · smokeAIRCRAFT WAS NOT GROUNDED: MID LAVATORY SMOKE CAUTION IN FLIGHT LASTED 2 SECONDS AND SELF CLEARED. HOT WATER HEATER WAS FOUND TO BE VERY WARM WITH FLASHING YELLOW LIGHT. REPLACED MID LAVATORY WATER HEATER PER AMM 38-12-16.SDR R61A2023091700514Drain Mast · smokeFA REPORTED SMOKE IN FWD GALLEY DURING CRUISE, NO ALARM, NO MESSAGE IN FLIGHT DECK. FA SAID SMOKE WAS COMING OUT OF FWD GALLEY SINK DRAIN AND SMELLED OF PLASTIC BURNING. DECLARED EMERGENCY AND LANDED WITHOUT INCIDENT. R&R FWD DRAIN MAST. NO SIGNS OF PLASTIC SMSDR AALA202309087503Toilet · inoperativeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED, AND THE AIRCRAFT DIVERTED TO AKL AND LANDED SAFELY. 5 EACH LAVATORY WENT INOPERATIVE WITH SCREEN SAYING FAULT RED.**SUPPLEMENTAL REPORT FOR (AALA202309017503): REMOVED AND REPLACED 3L LAV TOILET PER AMM 38-32-0SDR 2023F00263Water System · fault messageWATER ON FAB WAS ZERO. LAVATORIES WERE NOT AVAILABLE 31.AUG.2023 => WO 54425667 IAW TSM 38-12-00-810-815-A. WATER LEAKAGE FROM POTABLE WATER SYSTEM TASK WAS PERFORMED, POTABLE WATER SERVICING WAS PERFORMED, SYSTEM WAS PRESSURIZED, SYSTEM IS OPERATING SDR CALA2023083002664Plug · leakingBOTH REAR LAVS LEAKING CONTINUOUSLY DURING FLIGHT BRADLEY NEIL PAUL TOMC APPROVES LAVATORY K & M TOILET FLUSH SYSTEM(S) INOPERATIVE AND DEACTIVATED. ASSOCIATED LAVATORY(IES) IS NOT USABLE PER MEL 3830C. BOTH TANKS DUMPED/DRAINED AND NO LEAKS DISPATCH DESK: 349SDR CALA2023081802572Valve · inoperativeWIZ DRAIN AT AFT GALLEY AFT OF DOOR 4L IS NOT CLOSING DURING CABIN PRESSURIZATION (SINK DRAIN IS MAKING VERY LOUD NOISE). REQUEST TOMC TO APPROVE MEL3810AC FOR DEFERRAL. REQUEST TOMC TO APPROVE TO APPLY MEL 3810CQ. TOMC APPROVED DEFERRAL MEL3810CQ. ISOLATED DRSDR CALA2023081602542Waste Tank · unknownNO WATER IN ALL LAVS SERVICED POTABLE WATER, TANK APPEARED EMPTY. PER F/A CREW, ALL NOTICED NO PRE-CHARGE DURING WASTE TANK DRAINING. FLUSHED WASTE WORKED NORMAL THEN WATER QUIT AFTERR 1 HOUR INTO THE FLIGHT. TANK AND SERVICED PRECHARGE. POTABLE WATER SERVICEDSDR UIEA2023063000676Unknown · unknownFUSELAGE - STRUCTURE AROUND OPENINGS - NUMBER 1 WINDOW FRAME - POST PREVENTIVE MODIFICATION INSPECTION - SB 737-53-1335 - AD 2013-19-23 AMOC IAW ATLAS AIR EO 3853A035 REV.0, PARTS 2-3.(<P>PEFORMED POST PREVENTIVE MODIFICATION INSPECTION - SB 737-53-1335 - AD 2SDR CALA2023081102483O-Ring · unknownTHIS WRITE UP IS TO COVER AN IN DEPTH CLEAN UP FROM LEAKING WATER TANK DRAIN. LEAK IS REPAIRED. WITHIN 7 DAYS ACCOMPLISH EC/RA 2011-01000, CARGO COMPARTMENT SPILL, SECTION 2.B, IN DEPTH CLEANUP, IN THE APPROXIMATE AREA OF STA 9500/FR24 TO STA 15367/ FR35. FROMSDR CALA2023073102373Water Heater · leakingAFT LAV FLOODED. AFT LEFT LAV-D WATER HEATER LEAKING AND CREATED A VERY LARGE WATER LEAK RUNNING DOWN TO CARGO PIT AND COMING OUT OF BELLY DRAINS. SEE LOG 5261867 FOR CLEAN UP AND LOG 5261798 FOR LAV-D SINK INOP. AFT LAV-D WATER HEATER INOP -- S/OFF VALVE TO TSDR CALA2023072102291Clamp · corrodedOBSERVED LK FROM BILGE DRAIN AT CENTER OF AIRCRAFT, AFTER INVESTIGATION FOUND LK FWD OF GRAY WATER HOLDING TANK.PERFORM CLEANUP AS PER ECRA 2011-01000 DUE TO GRAY WATER LEAK FOUND. COMPLETED SPILL CLEAN UP THROUGH STEP 2 B (13) ECRA 2011-01000. ADD EMP:U411446SDR DALA2023071905822Unknown · unknownSHIP 1603 -ATB- DUE TO NO POTABLE WATER AVAILABLE AT SINKS OR GALLEY LOCATIONS. CORRECTIVE ACTION: R/R POTABLE WATER SYSTEM PRESSURIZATION SYSTEM CHECK VALVE AND PRESSURE RELIEF VALVE. POTABLE WATER SYSTEM COMPRESSOR FAILED AND DEFERRED PER MEL 38-10-01A (18JUSDR CALA2023071902279Float Valve · cloggedFWD LAV NOW LEAKING TWICE THE RATE THEN EXPLAINED. VERY NASTY ODOR UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK.MAC METER INITIATED FOR WITH VENDOR ID V929091 MAC RELATED WORK ORDER 000000003080619 AND PRTR CHAVEZSDR WX0A1900010031794Heater · unknown(EMERGENCY DECLARED) AT CRUISE AFT FA NOTED LAV G WAS VERY HOT INSIDE SINK AREA WAS VERY HOT TO TOUCH. CABINET BELOW SINK WAS OPENED AND VERY STRONG ELEC BURN SMELL OCUED + CONTINUED ALL THE WAY UNTIL LANDING. FA TOUCHED THE WATER HEATER AND WAS EXTREMELY HOT SDR SIMA20230711002Unknown · unknownBURNING PLASTIC SMELL AFT CABIN-C/A-IDENTIFIED ODOR COMING FROM LAV VACCUM GENERATOR.. DEFERRED PER MEL 38-09, AUTH#070355DM-C "M" PROCEDURES / DEACTIVATION C/WSDR HALA2023063000138Unknown · unknownATB - AIR TURN BACK MAJOR HAZMAT LEAK LAV G. LOCK LAV G - TOILET INOP - NOT USABLE. AREA CLEANED & SECURED BY CABIN SERVICE. REMOVED & REPLACED LAV G TOILET ASSY PER AMM 38-31-41-801-A. OPS & LEAK TEST GOOD. PLACARD REMOVED, MIC SHEET UPDATED.SDR CALA2023062802053Unknown · inoperativeDUE TO RETURN TO FIELD FOR ALL 3 LAV TANKS SHOWING FULL PLEASE A CP THE FOLLOWING: MAKE SURE THE VACUUM BLOWER CB''S ARE IN P110 Z 1, P210 Z1. ACP BITE CHECK OF ALL 3 LCM''S AMM 38-33-00-501. INSP ECT TANK FOR BROKEN VACUUM OR VENT LINES SEE IPC38-32-07-001 ITSDR CALA2023062802052Toilet · crackedON CLIMBOUT FA REPORTED URINE FLOWING FROM UNDER CARTS AND FA SE ATS FOUND TOILET ASSEMBLY CRACKED AND DAMAGED. TURNED WATER TO OFF POSITION AND LOCKED LAVATORY DOOR. LAVATORY CANNOT BE USED. PLACING ON DEFERRAL IN REF WITH MEL 3802D. FOSTER, RENE (V912208) DISDR CALA2023062802047Adapter · damagedAFT LAV LEAK IS REOCCURING PER F/AS. LEFT AFT LAV. ***TECH SUPPORT UPDATE*** WITH LAV D SINK PARTIALLY FULL FOUND 2 LEAKS TO BE FROM SMALL OVERFLOW LINE AND FROM DRAIN VALVE UNDER SINK. NEED TO REPLCE SINK DRAIN ASSY AND FLEX LINE GOING TO OVERFLOW.THANKS REPLSDR ASAA2023061943649Unknown · unknownAT 23:10 (APROX) AFT F/A SMELLED "DIRTY SOCK" SMELL AT ABOUT 1,500FT ON TAKEOFF. BLEEDS WERE IN NORMAL T/O POSITION (ENG 1+2 BLEED ON, AFT BLEED OFF L. PACK AUTO, ISOL AUTO, R PACK AUTO). SEEMED TO BE IN THE AFT LEFT GALLEY IT WAS A LEVEL 3 AIR QUALITY EVENT. SDR R61A2023070600378Panel · corrodedWATER WASTE DOOR PANEL CORRODED @ FR 86-89 STR 27R. REPLACED SERVICE PANEL IAW AMM 53-03-60SDR CALA2023061401853Unknown · inoperativeFLIGHT CREW REPORTS ALL LAVS WILL NOT FLUSH. VARGAS TOMC LOCKED BY TOMC TO BE WORKED WITH LMC LOG PAGE 4852252 UNLOCKED FOR CLEARING CB 33MG AND 35MG PULLED @ 2001VU REMOVED 38 MG REF SSM38-31-10. ADD EMP:U123409 RPL 36MG AND 300RH7 AFFECTING 300RH8 THAT IS INSDR YENA2023052600556Drain Mast · damagedFLT#1238, AUS-BOS. ' GO HIT FWD DRAIN MAST WITH BELT LOADER BREAKING IT APART FROM THE A/C; INSPECTED FWD FUSELAGE FOR DAMAGE - FOUND FWD DRAIN MAST BROKEN, ITEM TRANSFERRED TO DEFECT 3648863, ITEM 2 (REMOVED AND REPLACED FWD DRAIN MAST PER AMP 38-33-01). ALSOSDR CALA2023051801553Water Heater · unknownFLASH OF LIGHT SMOKE AND ACRID SMELL FROM FOWARD LAV AT CRUISE PERFORMED VISUAL INSPECTION OF LAVATORY ( A ) WIRING AND CREW. REMOVED AND REPLACED FIRST CLASS LAVATORY ( A ) WATER COMPARTMENTS FOR BURNING & ARCING, NONE FOUND. TROUBLESHOT HEATER, REF AMM 3SDR R61A2023042600257Toilet · unknownINSTALLATION OF REVOLUTION TOILET IN AFT LAV. PER STC ST02700LA AND 170EO-25-44-0003_1 (MAJOR)SDR R61A2023042600256Toilet · unknownINSTALLATION OF REVOLUTION TOILET IN FWD LAV. PER STC ST02700LA AND 170EO-25-44-0001_1 (MAJOR)SDR DALA2023041503000Unknown · unknownSHIP 0178 -DIV- TO LAX DUE TO 3 LAVATORIES INOPERATIVE WITH TANK INOP LIGHT ILLUMINATED. SECOND TANK IND HALF FULL. CORRECTIVE ACTION: VERIFIED ONE TANK FULL AND SECOND TANK HALF FULL. SYSTEM SERVICED AND OPS NML. (4779011)SDR CALA2023041201097Potable Water · unknownWATER SERVICE WAS OVERSERVICED. WATER WAS IN AFT CABIN GOING FORWARD 10 ROWS OF SEATS FROM AFT LAVS. BODY STATION 780 TO BODY STATION 1016, BETWEEN BUTT LINE LBL 50 AND RBL 50. WITHIN 7 DAYS , ACCOMPLISH EC/RA 2011-01000, GALLEY SPILL , SECTION 2.B., IN-DEPTH SDR CALA2023040401042Unknown · lowALL 4 LAVS INOP WATER PRESSURE LOW RAMP SERVICED AFT TOILETS BEFORE MX ARRIVED HOWEVER FORWARD TOILET WAS FOUND TO BE NOT PRIOR SERVICED. VERIFIED FORWARD TOILET HAD NOT BEEN SERVICED , AFTER RAMP SERVICE TOILET WORKS NORMAL WITH NO DEFECTS . UNABLE TO VERIFY SDR CALA2023033100958Vacuum Sys · odorFWD LAV INOP NOW FUNNY SMELL OF ELECTRICAL BURN ING REQUEST MEL 3802D. LAV NOT USABLE. PERFORMED CONDITIONAL INSPECTION. ODOR NOTICED WHEN FLUSH MOTOR EVIDENCE OF BURNING OR ARCING. REF AMM 05-51-26-800-801-C1. IS ACTIVATED AND DISAPATES QUICKLY. VISUAL INSP SDR CALA2023032700893Unknown · shortedNONE OF THE LAVS FLUSH VERIFIED VACUUM WASTE CONTROLL CIRCUIT BREAKER POPPED ON ARIVAL ISOATED SYSTEM FOUND PIN 1 ON D11702 SHORTED INTERMITTANTLY TO AND LAV DUMP HANDLE NOT SEATED FULLY.SEE PICTURES. GROUND. FOUND WIRE W5146-0101-18 CHAFFED APROX 18 INCHES AFSDR CALA2023032700891Unknown · unknownALL LAVS INOP. NO FLUSH FOUND CB EXTENDED FOR VACUUM WASTE CONT ON ARRIVAL FOUND VACUUM WASTE CIRCUIT BREAKER POP,RESET BREAKER AND REPLACED CONTROLLER AND ALL LAVS FLUSH NORMAL.MULTIPLE FLUSH AND FLUSH ONE TOILET AND BREAKER POPS AGAIN,DUE TO PREVIOUS PERFORMSDR CALA2023032400852Plug · unserviceableAFT LAV E SMOKE DET SOUNDED ON TAXI IN FA REPORTED ELEC SMOKE OD OR (D10) TRIPPED AND WILL NOT RESET WITH DOOR SWITCH AND TASK LIGH TS DISCONNECTED. TECH REMOVED AND REINSTALLED DOOR SWITCH. TASK LIGHTS IN NAPKIN COMPARTMENT REMAIN DISCONNECTED. UPDATED MAA COSDR CALA2023031700780Handle · missingPDA 3 T-HANDLE MISSING FROM LAV SVC STATION. APPLIED MEL APPLIED MEL. APPROVED SEE ATTACHED PHOTO. HANDLE 29-3830-3-0002. SLEEVE 29-3832-3-0042. WASHER 29-3832-3-0041. SCREW 00-0584-3-0788. REF IPC 38-32-51-04 REPLACED BROKEN T-HANDLE FOR LAV SERVICING. OPS CHSDR CALA2023020800371Vacuum Sys · not reportedNONE OF LAVATORIES WILL FLUSH APON ARRIVAL INTO MCO , FOUND VACUUM WASTE CONTROL CIRCUIT C11 VACCUM WASTE CONT C/B PER WDM 38-32-12-6 PG 6. SERVICED LAV BREAKER C11 OUT ON THE P91 BOARD. PREFORMED FIM 38-30 TASK 811 TANK AND OPERATED LAV SYSTEM SEVERAL TIMES. SDR ASAA2023012641652Unknown · unknownFWD LAV AND ACFT RH AFT LAV UNABLE TO FLUSH IN FLT NOTED WASTE LEVEL INDICATOR INDICATING FULL.UPON LANDING INDICATOR INDICATED 1/2 FULL SERVICED REPEATED THEY REMOVED 1/4 WASTE. GROUNDED - YES. DIVERSION -- SERVICED WASTE TANK MULTIPLE TIMES REF B737-800 AMM SDR CALA2023011600127Drain Line · leakingLARGE POTABLE WATER SPILL DETECTED 1/14/23 IN AFT CARGO BELOW CENTER FLOOR FROM FUSELAGE POTABLE WATER TANK OVERFLOW DRAIN PORT HOSE AT AFT SIDE OF AFT CARGO AFT BULKHEAD STA. 947 TO AFT CARGO FWD BULKHEAD STA. 727 FROM S25L-S25R. PERFORMED EC/RA 2011-01000 CASDR DALA2022110107078Tube · damagedDURING INSPECTION FOUND CORROSION ON TUBE, DECLAM AT LAV FWD. TUBE DECLAM AT LAV FWD WAS REPAIRED PER ERA 582489-14TR REV A.SDR CALA2022102402935None · noneLAV E CONTINUOSLY FLUSHING IN FLT LAV D DOES NOT FLUSH BOTH REAR LAVS INOP FOUND WATER TO AFT LAV TURNED OFF. OPS CHK LAV NUMEROUS TIMES NO FAULTS FOUND REF AMMSDR GTIA2022091936669Lavatory · inoperativeDIVERTED TO DEN BECAUSE ALL LAVS INOP IN FLIGHT-PERFORMED OPS TEST OF THE WASTE WATER DRAIN SYS PER AMM 38-32-00-710-002-A OPS CHECK GOOD AT THIS TIME NO FURTHER DEFECTS NOTED ALL LAVS NOW OPERATE AS DESIGNED ACFT OK FOR SERVICESDR SWIA202266614None · corrodedDURING REMOVAL OF WASTE TANK LOWER DRAIN TUBE, FOUND CORROSION DAMAGE TO LAV WASTE SERVICING SURROUND STRUCTURE (FOR REFERENCE SEE SRM 53-51-23), DAMAGE IS BETWEEN FS953.00 AND 969.00 AND BETWEEN STR23R AND STR24R. (FILED CLOSED) STRUCTURAL REPAIR - COMPLISDR CALA2022090202237None · leakingFOUND LAV E TOILET FULL OF WATER AND OVER FLOWING OPENED AFT CARGO PIT AFT BULKHEAD PANEL, R/H AFT SIDEWALL PANEL, DRAINED TOILET AND CLEANED LAV E INTERIOR AND CABIN FLOOR FROM AFTER TROUBLE SHOOTING FOUND TOILET RINSE VALVE LEAKING IN TO AND AFT FLOORBOARD. SDR CALA2022083102232None · cloggedALL LAVS CLOGGED EXCEPT AFT TWO LAVS TROUBLESHOOTING WITHOUT HELP ITEM NEED A DEFERRAL ACC MEL WATER SHUTOFF VALVES CLOSED. ITEM DEFERRED ACC MEL 3830 AV MMP PERFORMED 3830AV. MEL MAINTENANCE PROCEDURE PERFORMED. PLACARDS INSTALLED DISPATCH DESK: 3367 NAME: I.SDR CALA2022082902219None · noneALL LAVS INOP/WILL NOT FLUSH ON ARRIVAL FOUND FAP INOP LIGHT ON AND WASTE TANK INDICATION PRECHARGE OF 5 GALLONS AND TANK READ 15% AT FAP PANEL. ALLOWED FULL 100%. HAD LAV SERVICE DRAIN AND FLUSH TANK. TANK READ OVER 15% WITH 3 GALLONS. ALL 20% EMPTY. HAD LAVSDR CALA2022082602180None · noneWASTE DISPOSAL AFT LAV M - TOILET DOES NOT FLUSH AND RINSE SERVICED LAVS. OPS CHECK GOODSDR AALA202209012786Waste Tank · faultyAIRCRAFT WAS GROUNDED: LAVATORY HOLDING TANK NUMBER 2 SHOWED FULL (ALL RED) AFTER TAKE OFF, LOSS OF LAVATORIES: 1L, 3L, 4L. AIRCRAFT DIVERTED TO SEA. RELIABILITY OF TANK 1 AND 3 QUESTIONED. **SUPPLEMENTAL REPORT FOR AALA202208162786: REPLACED NUMBER 2 WASTE TASDR AALA202208162786None · noneAIRCRAFT WAS GROUNDED: LAVATORY HOLDING TANK NUMBER 2 SHOWED FULL (ALL RED) AFTER TAKE OFF, LOSS OF LAVATORIES: 1L, 3L, 4L. RELIABILITY OF TANK 1 AND 3 QUESTIONED. **SUPPLEMENTAL REPORT REQUIRED** (OPEN)
Back to JASC 3800