JASC 3800
Service difficulty reports · 226
Reports filed under 3800 · Water and Waste System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3800' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3800' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026070217533Faucet · looseCREW REPORTS FWD LAV FAUCET BROKE REQUEST MEL FOR FWD LAV FAUCET. APPROVED FOR MEL 3810A PLACED FWD LAV FAUCET INOP PER MEL FOUND HOT WATER SPIGOT ATTACHED TO FAUCET LOOSE. REVERSED MEL 3810A FWD LAV. INSTALLED FAUCET IAW AMM 38-12-41SDR CALA2026070717596Lavatory · leakingAFT CABIN SATURATED WITH WATER TO ROW 38 FROM LAV E APPROXIMATE AREA OF LAV E SPILLAGE IS FROM BS 907 TO 787 S-23L TO S-23R PERFORMED IMMEDIATE CLEANUP OF SPILLAGE AREA, THE WATER IS CLEAN WATER NOT WASTE WATER, THROUGHLY CLEANED LAV AREA AND CARPET OF ALL SDR CALA2026050415939Water Heater · odorDO THE SMOKE OR FUMES IN THE CABIN, SOURCE UNKNOWN - FAULT ISOLATION PER FIM 21-00 TASK 806. TOMC PL CREW BRIEFED THAT SMELL WAS COMING FROM LAV E, SAID THEY BELIVE THE SMELL WAS COMING FROM UNDER THE SINK. FOUND CB 18-3 F15 LAVATORY E WATER HEATER POPPED. PUSSDR CALA2026041715426Drain · corrodedWASTE TANK DRAIN ENCLOSURE HAS CORROSION AT THE AFT ANGLE THAT ATTACHES TO THE SKIN AND UNDER THE STAINLESS STEEL RING AT THE DRAIN DUCT. INSTALLED NEW PAN ASSY AT WASTE TANK DRAIN AS PER 51-40-02-0G-0 AND DRAWING 146A7400.SDR CALA2026040315052Drain · inoperativeTWO FORWARD LAVATORIES, BY DOOR 1 AS WELL AS FRONT GALLEY SINK NOT DRAINING AND OVERFLOWING WITH A FOUL ODOR. FOUND LAV B VACUUM INOPERATIVE, VALVE STAYS OPEN. REQUEST MEL FOR LAVATORY B AND LAV IS UNSUABLE. PLUG VACUUM PART # K38002-1 HAS BEEN INSTALLED INSDR CALA2026032314751Valve · leakingFWD GALLEY FWD WATER FILTER ASSY LEAKINGR&R FWD GALLEY WATER FILTER ASSY. REF AMM 38-11-41, PERF LEAK TEST REF AMM 25-31-00 NO LEAKS NOTED TRHU GALLEY FILTER ASSY. AT THIS TIME INSPECTED GALLEY GRAY WATER INTERFACE VALVE, VALVE CYCLES REPEATEDLY EVEN WITHOUT WSDR CALA2026011412950Unknown · leakingFLOOR OUTSIDE LAV D CONTINUES TO GET WETTER AFTER CLEAN UP. SEE PREVIOUS WRITE UP. THERE IS NO ACTIVE WATER LEAK FOUND. THIS EVIDENCE OF A POSSIBLE WATER LEAK CAME FROM LAV D CLOGGED SINK EARLIER THAT OVERFLOWED & CAUSED WATER SPILLAGE IN SURROUNDING AREA. SDR CALA2026011112854Lavatory · odorLAV A VERY FOUL ODOR SINCE TAKEOFF LAVATORY A CLEANED AS REQUIRED. NO FOUL ODOR AT THIS TIME. OK FOR SERVICE.SDR QXEA2025103100334Valve · damagedDURING REPLACEMENT OF THE FILL DRAIN VALVE FAOUND THE WATER HEATER VALVE TO BE DAMAGED AND THE INSULATION BURNT. INSTALLED NEW WATER HEATER FILL VALVE IAW E175 AMM 30-71-05-400-801-A AND REPAIRED INSULATION IAW E175 AMM 20-15-300-801-A. RETURNED TO SERVICE.SDR AALA202510030718Lavatory · odorAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY REPORTED AS STRONG ODOR FROM FLIGHT ATTENDANTS. ODOR IS STILL PRESENT AFTER A DEEP CLEANING, REPEAT WRITEUP. (OPEN).SDR CALA2025100209522Toilet · odorLAVATORY TOILET BOWL SMELLS BAD AT DR-1L FWD CABIN LAV A. REMOVED TOILET SHROUD NO LEAK DETECTED, SERVICED LAV A TWICE, CLEANED TRASH CAN AND CLEANED LAV A .SDR AALA202509256714Hose · leakingAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED STRONG ODOR ON TAKEOFF AND ON CLIMB OUT, THAT SMELLED LIKE DIRTY SOCKS. GOT BETTER IN CRUISE AND WORSE ON DESCENT. FOUND LEAKING GREY WATER HOSE ABOVE LT RECIRCULATING FAN FILTER. REMOVE AND REPLACED HOSESDR CALA2025090408467Lavatory · odorFWD LAV RANCID SMELL POSSIBLY FROM DRAINS. FLUSHED TOILET AND SINK DRAINS WITH SANI/CLEANER FLUIDS. NO LEAKS OR SPILLAGE AROUND DRAINS/FLOOR. OK TO CONTINUE SERVICE.SDR AALA202508220812Sill Drain · cloggedAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTS DURING DESCENT A STRONG ODOR ON THE LEFT AFT GALLEY AREA. FOUND AFT GALLEY THRESHHOLD DRAINS CLOGGED. CLEARED AFT GALLEY L2 (AALA202508228549) AND R2 (AALA202508220812) DOOR THRESHHOLD DRAINS.SDR CALA2025080507291Lavatory · dirtyFWD LAV EMITS STENCH AFTER FLUSHING NO FOUL ODOR DETECTED AFTER LAV SERVICING WAS PERFORMEDSDR CALA2025072806940Line · out of positionUNUSUAL PLASTIC ODOR IN FWD LAV AFTER START FOUND ORANGE SINK DRAIN LINE COMING IN CONTACT WITH WATER HEATER.REROUTED DRAIN LINE AWAY FROM HEATER, BURNING SMELL WENT WAY.NO DMG TO DRAIN LINE FOUND.SDR CALA2025070706228Lavatory · odorFWD LAV LEAKING WATER, STRONG ODOR. REMOVED SHROUD AND VERIFIED RINSE WAS ISSUE, NO LEAKS WITH RINSE VALVE OFF. REQUESTING DRY FLUSH FOR LAV A MEL 3802. CAPTAIN REQUESTED LAV BE AVAILABLE. COMPLIED WITH MEL 3802B PLACARD INSTALLED. FWD LAV A DRY FLUSH. REVERSDR CALA2025061805653Unknown · odorBACK OF AIRCRAFT AND AFT GALLEY HAD FECAL ODOR ON TAKEOFF. SMELL SUBSIDED AFTER CRUISE. INSPECTED AREA FOUND NO EVIDENCE OF SPILL, FLUSH LAVS D&E NO LEAKS NOTED. GALLEY AREA FOUND TO BE DRY.SDR CALA2025052704948Drain Mast · cloggedFA REPORT A BAD SMELL IN GALLEY AREA. POSSIBLY COMING FROM CLOSE T. STRONG ODOR FROM FWD GALLEY AREA AND FIRST CLASS. COMPARTMENT 109 DRAIN STRAINER AREA CLOGGED. FIRST CLASS CARPET WET ROW 1AB. LOOSENED 2 CLAPS ON DRAIN HOSE BELOW Y LINE FOR TROUBLESHOOTING PSDR CALA2025052604940Drain · cloggedFOUL ODOR IN AFT GALLEY ENTIRE FFLT. ON LANDING LIQUID BACKWASHED FROM DOOR FLOOR DRAINS CLEARED BLOCKAGE IN AFT GALLEY DOOR DRAINS. DRAINS OPERATING NORMAL. REF AMM SUBTASK 38-31-06-860-002SDR CALA2025042804253Unknown · leakingNEAR DOOR 1L GIRT BAR SEWAGE LIQUID LEAKING DIRTY BAD SMELL PERFORMED GV OF DOOR L1 FLOOR DRAINS NO BLOCKAGE FOUND. CLEANERS CLEANED FLOOR AND DRAIN AREA.SDR CALA2025041103694Drain · cloggedON TAKEOFF SMELLY WATER COMES UP AND PUDDLES ON FLOOR FROM LEFT FLOOR DRAIN BY DOOR 1L CLEANED L1 FWD AND AFT FLOOR DRAIN WITH DRAIN SCRUB.SDR CALA2025040203456Line · leakingWATER LEAKING FROM OVHD DOOR 4R FOUND WATER LINE ABOVE LAV AT 4R DISCONNECTED. SEE PHOTOS. ADD EMP:U412608,U416150 WIGGINS FITTING REPLACED NO LEAKS NOTED. ALL MX COMPLETE AND CLEAN UP COMPLETE. A/C BIS.SDR AALA202503175562Water Heater · defectiveAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT REPORTED A BURNING RUBBER SMELL AT ROW 22 STARTING AROUND 10,000 FEET UNTIL AFTER LANDING. MAINTENANCE FOUND THE MID LAVATORY WATER HEATER WAS THE SOURCE OF THE BURNING SMELL AND REPLACED IT PER AMM 38-12-16. A SATISFACTSDR CALA2025031402812Water Heater · faultedREF LP 4141729, ASSOCIATED FWD LAVATORY WATER HEATER HAS BEEN DEFERRED IN COMPLIANCE WITH MEL CARD 38005. PLACED FWD LAV WATER HEATER ON MEL 3801F. MEL DDP C/W. PLACARD INSTALLED. TOMC APPROVED MEL 3801F. PLACED FWD LAV WATER HEATER ON MEL 3801F. MEL DSDR CALA2025021002253Sink · cloggedAFTER TAKE OFF ABOUT 2.5 HOURS IN FLIGHT WATER STARTED COMING OUT OF THE FWD LAV SINK DRAIN AND FILLING SINK TO POINT OF OVERFLOW. TOMC REQUESTS TO CONFIRM DRAIN LINES ARE CLEAR TO FWD DRAIN MAST AND TO VERIFY PROPER OPERATION OF FWD DRAIN MAST HEATER. REF LOGSDR CALA2024121003050Shroud · crackedLARGE POTABLE WATER LEAK FROM WATER LINE, FWD E&E COMPARTMENT, BETWEEN RH STA. 254-269, ABOVE NOSE WHEEL WELL AND CABIN FLOOR, SEE PICS. LEAK MAY BE FROM 2 LOCATIONS: WATER LINE COUPLING JUST BELOW FLOOR LINE, AS SEEN IN PHOTO, AND WATER LINE IN CABIN AREA, BESDR CALA2024102800939Blower · faultedLAVS 2L 2R 3R 3C 4L WILL NOT FLUSH PLACED ITEM ON MEL FOR CENTER WASTE TANK. DISPATCH DESK: 60 .NAME: PP.DATE: 25-OCT-24. APPROVED PLACED ITEM ON MEL. LAV FLUSHES NORMALY ON GROUND. R&R VACUUM BLOWER SYSTEM #2 RLY (K38201), REF: FIM 38-30 TASK 818, AND R&R VACSDR CALA2024103000965Waste Tank · leakingREF LP 9680021 , WASTE WATER LEAKED FROM AFT WASTE TANK LEVEL TRANSMITTER BEHIND AFT BULKHEAD, DOWN AND ALONG BELLY SKIN GOING FOWARD BELOW AFT PIT FLOOR , AND COMING OUT FROM FWD DRAIN OF AFT CARGO PIT. LEAK WAS RPRD, NEED TO ACP IN-DEPTH CLEAN UP OF SPILL ANSDR AALA202410028839Software · faultyAIRCRAFT WAS NOT GROUNDED: AIRCRAFT HAD MEL 38-01D FOR WATER QTY INOP. AIRCRAFT WATER WAS TOP OFF AT DEPARTING STATION. DURING CRUISE ALL WATER STOPPED WORKING. FLIGHT WAS DIVERTED TO LHR. MAINTENANCE SUSPECTS FAULTY SOFTWARE: MAINTENANCE RELOADED SOFTWARE ISDR DALA2024091008906Control Module · odorMID LAVATORY FACING FORWARD HAS VERY ODD CHEMICAL OR FERTILIZER SMELL. VERY STRONG ODOR THAT AFFECTS EYES AND THROAT. CORRECTIVE ACTION: R/R FAUCET CONTROL MODULE. IAW B767 AMM REF 38-11 NO FAULT FOUND . NO SMELL NOTED. OPS CHK NML.SDR CALA2024090300538Valve · faultyWATER LEAKING IN ALL 3 GALLIES CEILING CUBBIES AND FLOOR FLAGGING 4-1 GWIV FAULT 38-18235 PERFORMED FIM B787-A-38-30-F1-72A-421A-A VERIFIED SOFTWARE PN BCG41-CCS0-01V3 INSTALLED SUSPECT GWIV FAULTY PART IN STOCK IN IAD. PERFORMED WIRE CHECKS REF FIM. DMC-B78SDR CALA2024082700502Tank · faultyDUE TO REPORT OF BANGING NOISE UNDER THE FLOOR IN THE AFT AREA OF THE CABIN, GAIN ACCESS & INSPECT POTABLE WATER TANK MOUNT ATTACH POINTS (4 EA) AND WATER TANK ANTI-SWAT STRUT ATTACH POINT & SHEAR PIN AS DEPICTED IN MM38-11 01-004-078-001. CARRIED BY ELB ACCOMSDR AALA202408037625Shutoff Valve · leakingAIRCRAFT WAS GROUNDED: ,WATER LEAK LAV 3F-1R WATER TO LAV SHUT OFF. MAINTENANCE REPLACED GRAY WATER VALVE ON LAV 3F-1R. PILOTS DIVERTED TO PHL DUE TO A LAVATORY LEAK. EMERGENCY WAS DECLARED AIRCRAFT LANDED WITHOUT INCIDENT.SDR CALA2024071700226Unknown · leakingDUE TO WATER LEAK AT LAV D THE CENTER SECTION OF CARPET WAS FLOODED. CENTER SECTION OF CARPET TO 11 WINDOWS FWD OF AFT LAV. SCRUBS CLEANED AREA AND DRIED . INSPECTED AFT PIT FOUND NO SIGNS OF WATER PASSING THROUGH FLOOR AND NO ELECTRONICS IN AREA. REQUIRES IN SDR CALA2024070101932Water System · leakingFWD LAV HAS A WATER LEAK . WATER COMING FROM UNDE R THE PANELS A ROUND THE TOILET. LEAK IS NOT URINE. LEAK IS CLEAN WATER. POSITIONED WATER VALVE MEL APPLIED. WATER SHUTOFF. WATER HEATER SHUTOFF, CB PULLED UNDER SINK TO OFF. CLEANED UP SMALL AMOUNT WATER USDR AALA202406274112Drain Valve · cloggedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: ORDER FUME IN AFT OF PLANE, WORSE IN AFT GALLEY OILY MUSTY SMELL THAT MADE EYES WATER. COULD NOT DETERMINE SOURCE; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT ELP. ACCOMPLISHED SOF TROUBLESHOOTING WORKCARDSDR DALA2024061806192Tube · corroded(LOG 5973176) DURING CRV FOUND CORROSION AT LOWER AFT AISLE CORNER OF LAV MODULE. REMOVED AND REPLACED AFT TUBE AND BOTTOM ATTACHMENT ANGLE REF. B/E AEROSPACE CMM 25-40-63.SDR DALA2024061806191Tube · corroded(LOG 5973175) DURING CRV FOUND CORROSION AT LOWER AFT AISLE CORNER OF LAV MODULE 204. REMOVED AND REPLACED AFT TUBE AND BOTTOM ATTACHMENT ANGLE REF. B /E AEROSPACE CMM 25-40-59.SDR DALA2024053005629Lavatory · odorSHIP 3235 DISC: FA IN AFT CABIN COMPLAINED OF AN ODOR. COULD NOT BE SENSED IN FRONT OF CABIN OR FLIGHT DECK. C/A: PERFORMED W/C 0550-2002, TYPE 9 MISCELLANEOUS ODOR IN THE AFT CABIN. FOUND AFT LAVS TO HAVE A STINK SMELL, CLEANERS WERE ABLE TO CLEAN & REMOVE SMSDR CALA2024052901619Lavatory · inoperativeALL LAVS/TOILET AND FAUCETS/ STOPPED WORKING. FOUND LAV TO BE FULL/OVERFULL. ALL LAV/SINKS WORK NORMAL AFTER A FULL LAV SERVICE.SDR CALA2024042201153Drain Mast · crackedDURING SERVICE CHECK, WALK AROUND INSPECTION FOUND FWD DRAIN MAST DAMAGE, PERFORMED ADDITIONAL WALK AROUND INSPECTION, NO ADDIDIONAL DEFECTS NOTED. REMOVED AND REPLACED FWD DRAIN MAST REF AMM 38-31-01/401. DRAIN MAST OPS CHECK GOOD.SDR CALA2024041801134Controller · faultedALL TOILETS STOPPED WORKING AT SAME TIME IN FLIGHT FOUND VACUUM WASTE CONTROL C.B. POPPED ON P 91 PANEL,RESET AND POPPED AGAIN. DISCONNECTED LOGIC CONTROL MODULE AND BREAKER STAYS RESET. WITH J4 CANNON PLUG OF LCM CONNECTED,VACUUM WASTE CNTRL C/B ON P91 PANEL SDR AALA202404155098Rod · looseAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO CLT DUE TO A VERY LOUD METALLIC GRINDING SOUND COMING FROM FLOOR LEVEL, BEHIND THE WALL, OR UNDER THE FLOOR IN THE AREA OF THE MID LAVATORY ON LEFT SIDE. THE NOISE WAS HEARD DURING FSDR SWIA202402270005Faucet · leakingD; FORWARD LAV FAUCET LEAKING BEHIND SINK.C; MEL 38-10-0ACAT: "C" DUE 3/6**** DUE TO ODI EVENT****MANAGEMENT APPROVAL IS REQUIRED VIA MXC SUPERVISOR PRIOR TO RETURN TO SERVICE AFTER CLEARING THIS DEFERRAL. **** (FLIGHT 5618 FILED CLOSED)FEB 25, 2024 STATION: SDR CALA2024011200082Plate · corrodedGEN ITEM: 63-3810-1-2801 AFT POTABLE WATER SERVICE PANEL HAS CORROSION IN MULTIPLE SPOTS MARKED REF AMES NR 165631-0100-0038 REMOVED DAMAGED PANEL AND FOUND TO BE OUT OF LIMITS AND REPLACED WITH NEW PANEL IAW B767 SRM 52-40-01-1A-7 AND SRM 51-40-02 PARA GRAPHSSDR CALA2023122903752Tank · fullALL LAVS HAVE BEEN REPORTED AS NOT FLUSHING BY FLT ATTENDANTS LIQUID DOES NOT DRAIN ALL LAVS FLUSH EXCEPT RT AFT ON MEL. LAV TANKS VERY FULL, HAD LAV SERVICE DUMP AND RESERVICE LAVS EXCEPT RT. AFT. ALL CK NORMAL NOW OK TO CONTINUE.SDR AALA202312279260Unknown · unknownAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: ALL 3 TOILETS WOULD NOT FLUSH. AIRCRAFT DIVERTED AND LANDED SAFELY AT CLT WITHOUT FURTHER INCIDENT.**SUPPLEMENTAL REPORT WILL BE SUBMITTED**(OPEN).SDR CALA2023122603729Coupling · failedSTRONG SMELL NOTED IN CABIN. REF. AAR N/R:9760404 INSPECTED AFT CARGO COMPT WASTE TANK COMPT FOR STRONG SMELL NOTED ORIGIN. AFTER WASTE TANK BULKHEAD PANELS REMOVAL FOUND EVIDENCE OF WASTE SPILL, WORKED EC/RA 2011-01000 IN DEPTH CLEANUP. REMOVED FLOOR PANELS FSDR AALA202312116892Faucet · detachedAIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: LAVATORY FAUCET CAME OFF, UNCONTROLLABLE WATER SPRAYING EVERYWHERE. AIRCRAFT DIVERTED AND LANDED SAFELY AT MEM WITHOUT FURTHER INCIDENT. INSTALLED NEW FAUCET IN LEFT AFT LAVATORY CHECK AND LEAK CHECK
Back to JASC 3800