Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3820' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3820' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM88091641Water Heater · overheatedAFT LT LAV SMOKE DETECTOR CHIRPING AT GATE. FOUND AFT LT LAV WATER HEATER OVERHEATING. FWD ITEM TO NEF 381.043 FOR REPLACEMENT-ALSO DETERMINED EXTERNAL START CART CONTRIBUTING FUMES INTO THE CABIN. REMOVED START CART (14138)-NO FURTHER ISSUES.SDR YENA20090225017Water Heater · defectiveFLT 125 - JFK-DEN - EN ROUTE, IN FLIGHT CREW MEMBERS COMPLAINED OF BURNING ELECTRICAL SMELL FROM LAV E. TRIED TO ISOLATE SMELL BY REMOVING INCANDESCENT LIGHT BULB, WHICH WAS CONSTANTLY ON AND HOT. IT SHOULD TURN OFF WHEN DOOR IS OPEN AND UNLOCKED. LAV SYSTESDR CA081009001Water Heater · damaged(CAN) ON CLIMB OUT SMOKE WAS OBSERVED COMING OUT OF THE FUEL CONTROL PANEL IN THE FORWARD GALLEY. THE WATER HEATER INSULATION BLANKET IN THE FORWARD GALLEY HAD EVIDENCE OF HEAT DAMAGE. INSTALLATION OF THIS PART IN THE FORWARD GALLEY OF THE ACFT IS A PART OF SDR 2007UALA01498Water Heater · failedNO H2O PRESSURE TO LAVS OR GALLEYS. 1:10 INTO FLT AFT LAV H2O HEATER. AFT LAV, LAV 'R', LAV IS WHERE ACRID ODOR WAS COMING FROM. FOUND WATER HEATER OVERTEMP CONDITION TRIPPED CIRCUIT BREAKER INSIDE HEATER. LAV IS WHERE ACRID ODOR WAS COMING FROM. CB ON PNSDR CA070403005Water Heater · odor(CAN) WHILE EN ROUTE, A BURNING ODOR WAS NOTICED BY THE CREW AND PASSENGERS. NO SMOKE WAS APPARENT IN THE CABIN OR COCKPIT. THEN SEARCHED THE LAVATORY AND BAGGAGE COMPARTMENT. A TRACE OF SMOKE WAS FOUND IN THE BAGGAGE COMPARTMENT. A QUICK VISUAL INSPECTIONSDR DL777060935Water Heater · overheatedAFT LEFT LAVATORY WATER HEATER OVERHEATED IN FLIGHT. STRONG ODOR, LAVATORY LOCKED OUT. HEATER DISABLED. ODOR PERSISTS. REPLACED LAVATORY WATER HEATER. OPS NORMAL. EXAMINED WIRING. NO FAULTS. AIRED LAVATORY AND ODOR MINIMIZED.SDR DL76G060333Faucet · stuckON TAXI OUT ACFT BEHIND OURS REPORTED FLUID LEAKING FROM LOWER CENTER FUSELAGE AREA BY DRAIN MAST. FOUND SINK FAUCET STUCK OPEN IN FWD MID ECONOMY LAV. FAUCET NOW OPERATING NORMALLY. ETOPS CATEGORY (F): ANY OTHER EVENT DETRIMENTAL TO ETOPS.SDR 2005FA0001279Water Heater · failedFA COMPLAINED ABOUT NO HOT WATER AT GALLEY SINK SHORTLY BEFORE LANDING. ONCE ON GROUND, MAINTENANCE EXPOSED WATER HEATER, GOT HEAVY BURNED SMELL. REMOVED FALSE PANEL COVERING WATER HEATER, NOTED THAT NO CB EITHER ON UNIT OR ON GALLEY CB PANEL HAD TRIPPED. DSDR DLM88050033Water Heater · shortedDURING DESCENT FWD LAV SMOKE DETECTOR WENT OFF. F/A NOTED A CHEMICAL SMELL WHEN THE DOOR WAS OPENED. REPLACED OVERHEATED WATER HEATER.SDR CALA0400058Connector · shortedTHE FORWARD LAV WATER HEATER CIRCUIT BREAKER POPPED WHILE ON DESCENT INTO EWR. THE LAV SMOKE DETECTOR ACTIVATED AND THE FLIGHT ATTENDANTS NOTICED SMOKE IN THE FORWARD LAV SHORTLY AFTER THE C/B POPPED. AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED AT EWR WSDR ASAA0380843Water Heater · shortedLAS - DURING TAXI TO GATE, SMOKE OBSERVED IN RIGHT AFT LAVATORY. DETERMINED TO BE ELECTRICALLY SHORTED WATER HEATER CAUSE BY LEAKING HEATER ASSEMLBY HOSE. TURNED OFF ALL AIRCRAFT ELECTRICAL POWER DURING REMAINDER OF TAXI. REPLACED WATER HEATER. (M)SDR CA031021001Heat Tape · burned(CAN) WATER LINE P/N 10-61998-310 OUTER WOVEN COVERING BURNED THROUGH AND PLASTIC INNER CORE PARTIALLY BURNED. ALL FOUR WIRE STRANDS WERE BURNED THROUGH ON THE HEATER TAPE. IN SECTION 45H20 LINE AND HEATER TAPE REPLACED.SDR 2003F00611Mount · crackedDURING MAINTENANCE IT WAS NOTED THAT THE FORWARD AND AFT MOUNT STRUCTURES FOR THE AFT WATER HEATER WERE FOUND DAMAGED. WATER HEATER IS SUSPENDED AT 6 POINTS. THE REAR MOUNT WHICH PREVENTS LATERAL MOVEMENT AND THE FORWARD MOUNT WAS FOUND TO BE CRACKED. THE HSDR 2003FA0001042Relief Valve · failedRELIEF VALVE IS INSTALLED ON HEATER ASSY: FAILURE CAUSED ENTIRE WATER SYSTEM TO DRAIN INTO FUSELAGE. THIS RELIEF VALVE SHOULD BE PLUMBED INTO EXISTING AIRCRAFT DRAIN SYSTEM, SO WATER FLOWS OUT DRAIN MAST INSTEAD OF OUT THE FUSELAGE DRAIN HOLES.SDR 2003F00612Mount · crackedSTRUCTURE FOR WATER HEATER AFT MOUNT FOUND DAMAGED. WATER HEATER IS SUSPENDED BY 6 POINTS. THE REAR MOUNTING STRUCTURE PREVENTS LATERAL MOVEMENT. IT APPEARS THE POSSIBLE CAUSE FOR THE DAMAGE IS A BURR AT THE SUBJECT MOUNTING HOLE. ALSO COULD BE DUE TO IMPROSDR DL76L021135Line · leakingF/C LAV LEAKED WATER INTO E/E COMPARTMENT CAUSING DAMAGE TO ELECTRICAL COMPONENTS. REPAIRED LEAK.SDR CHQ00076Cap · out of positionAFTER TAKEOFF, F/A NOTICED LOUD AIR RUSHING FROM BEHIND LAV MIRROR, CAPT AND F/O VERIFIED AND TURNED OFF EACH PACK SEPARATELY, AND TRIED APU BLEED, NOISE CONTINUED. NOTICED WHILE AIRCRAFT WAS PRESSURIZED, FOUND AIR COMING FROM WATER TANK, FOUND CAP THAT ATTACSDR USAAD01111Water Heater · malfunctionedPHL-IND - FLT 1787 - DURING DESCENT, AN ELECTRICAL BURNING SMELL WAS DETECTED IN THE LAVATORY AREA. THE AFT LAVATORY WATER HEATER CIRCUIT BREAKER WAS PULL BUT THE SMELL CONTINUED. THE AIRCRAFT CONTINUED TO ITS DESTINATION AND LANDED WITHOUT INCIDENT. MAINTESDR 2000UALA00671Heater · overheatedELECTRICAL ODOR IN FORWARD CABIN DUE TO WATER HEATER OVERHEATING.SDR 2000UALA00668Heater · overheatedRIGHT MAINT GEAR GREEN LIGHT DID NOT ILLUMINATE FOR LANDING. AIRCRAFT COMPLETED FLYBY TO VERIFY GEAR DOWN. AMBER ALERT DECLARED. UNEVENTFUL LANDING. *S/D* MAINTENANCE FOUND WATER SYSTEM FILL VALVE IN OPEN POSITION, INHIBITING PRESSURIZATION OF THE WATER SSDR 2000UALA00291Heater · failedCREW REPORTS SMOKE DETECTOR ALARM SOUNDING CONTINUOUSLY WITH NO ELECTRONIC CENTRALIZED AIRCRAFT MONITORING SMOKE WARNING. *S/D* REPLACED HOT WATER HEATER.SDR DL76G000952Compressor · inoperativePRIOR TO BOARDING STRONG SMELLY SMOKE POSSIBLE ELECTRICAL WAS NOTED BY FLT ATTENDANT IN RT REAR OF CABIN. FOUND WATER COMPRESSOR FROZEN AND C/B POPPED AND MELTED PLASTIC INSIDE HOUSING. REPLACED COMPRESSOR.SDR MWEA00036Heater · malfunctionedFLIGHT CREW NOTICED SMOKE COMING FROM THE LEFT LAVATORY AT THE GATE. EVIDENCE OF ELECTRICAL FIRE. MTC REMOVED AND REPLACED LAV WATER HEATER, FLUSH TIMER, WATER HEATER CIRCUIT BREAKER, AND INSTALLED GROUNDING STRAP.SDR 99ZZZX838Heating Blanket · failedAFTER TAXI AND ENGINE SHUT DOWN WITH APU OPERATING, FLIGHT CREW NOTED STRONG ODOR FROM CABIN AREA. FURTHER INVESTIGATION REVEALED ODOR EMANATING FROM LAVATORY VANITY AREA. CREW IMMEDIATELY REMOVED ELECTRICAL POWER FROM AIRCRAFT. AIRCRAFT WAS SENT TO MAINTENSDR GTIA9800019Water Heater · failedSMOKE NOTED IN LAVATORY, AIRCRAFT RIGHT. DISCOVERED SMOLDERING INSULATING MATERIAL IN TAIL COMPARTMENT. FOUND LAV WATER HEATER INTERNAL LEAK AND SHORTED, DEFERRED PER MEL 25-12 DMI NR 492. PLACARDS INSTALLED. REMOVED AND REPLACED RIGHT LAV. WATER HEATER ISDR AALA971602Water Heater · defectiveDFW - FLT 570 - EN ROUTE COS/DFW - DURING CRUISE, LOUD POP HEARD FROM FORWARD LAVATORY FOLLOWED BY SMOKE SMELL WHICH DISSIPATED QUICKLY. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED TO DFW, LANDING WITHOUT INCIDENT. PLACARDED FORWARD LAVATORY HOT WATSDR USAASB97225Water Heater · odorPHL - FL 1268 - FLIGHT ATTENDANT REPORTED, ELECTRICAL SMELL IN FORWARD AND AFT LAVS ON APPROACH INTO PHL. THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. SERVICED/OPERATIONALLY CHECKED WATER HEATER SYSTEM. SYSTEM CHECKS OK. NO FAULTS FOUND. (M)SDR DLM88970736Water Heater · over heatedSMOKE DETECTOR IN RIGHT AFT LAV WENT OFF ON SHORT FINAL. PULLED ALL LAV C/B. CREW AND PASSENGERS REPORTED ELECTRICAL SMELL. C/B WAS PULLED FOR WATER HEATER AND ALARM STOPPED. INSPECTED AREA, FOUND OK. FORWARD WATER HEATER TO MCO/PLAC PER MEL 25-00-12 C/B SDR IXXA9700027Water Heater · failedDURING DESCENT, THE FLIGHT ATTENDANT REPORTED VIA INTERPHONE TO COCKPIT, THAT THE RIGHT AFT LAVATORY SMOKE DETECTOR WAS SOUNDING AND A SMELL OF SMOKE. THE FLIGHT ENGINEER WAS DISPATCHED TO INVESTIGATE. THE FLIGHT ATTENDANT DISCHARGED A PORTABLE FIRE EXTINGUISDR 96ZZZM52Water Heater · smokingMCO - FLT NR 265 - DURING DESCENT, SMOKE WAS DETECTED IN AFT LAVATORIES. LAVATORY CIRCUIT BREAKERS WERE PULLED, SMOKE IMMEDIATELY CEASED AND DISSIPATED. THE LAVATORY WATER HEATERS WERE FOUND WITH NO WATER IN THEM. HEATERS WERE PURGED AND OPERATIONIONALLY CHSDR HAL95150Hose · puncturedHNL - FLT 22 - INFORMATION TAKEN FROM LOG PAGE 3657248 - REAR LAVATORIES, DENSE SMOKE, STEAM, AND ODOR. FOUND HOSE, PN 159445, PUNCTURED IN NR 3 AFT LAVATORY, REMOVED AND REPLACED HOSE. OPS CHECK, LEAK CHECK OK. (X)SDR COM60507Water Heater · malfunctionedCARGO COMPARTMENT BULKHEAD VERY HOT TO TOUCH. FOUND LAVATORY WATER HEATER OVERHEATING. DISABLED WATER HEATER AND PLACED ON DEFERRED MAINTENANCE LIST.SDR DLL13951606Hot Water Heater · malfunctionedDURING CLIMB, FLIGHT ATTENDANT REPORTED SMOKE IN AFT LAVATORY. RETURNED TO DFW. FOUND LAV SINK OVERFLOWING WITH EXTREMELY HOT WATER DUE TO FAULTY WATER HEATER. REPLACED WATER HEATER OPERATION NORMAL.
Back to JASC 3820