What was found
HNL - FLT 22 - INFORMATION TAKEN FROM LOG PAGE 3657248 - REAR LAVATORIES, DENSE SMOKE, STEAM, AND ODOR. FOUND HOSE, PN 159445, PUNCTURED IN NR 3 AFT LAVATORY, REMOVED AND REPLACED HOSE. OPS CHECK, LEAK CHECK OK. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.