JASC 3830
Service difficulty reports · 747
Reports filed under 3830 · Waste Disposal System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013090991141Valve · leakingLT CENTER LAVATORY RINSE VALVE LEAKING. WATER SHUT OFF. PLACED LAVATORY ON IAW MEL 38 -30M. WATER SHUTOFF & LAVATORY SECURED. LT AFT CENTER LAVATORY PC NR 160-9511.SDR CALA2013083090878Drain Valve · jammedAFT LAVATORY HAS OVER FLOWING BLUE WATER. BLUE WATER CONTAINED IN LAVATORY. DID LIQUID CLEAN UP & PLACED AFT LAVATORY ON MEL. WASTE TANK DRAINED VALVE ASSEMBLY JAMMED. REPLACED IAW MM38-32-16. OPERATIONS CHECKED OKAY, NO LEAKS NOTED.SDR CALA2013081390382Pipe · corrodedRAMP REPORTED BLUE FLUID LEAKING INTO AFT CARGO PIT REMOVED WASTE TANK COUPLING AT TANKS FWD END. FOUND END OF PIPE CORRODED OFF THE TANK. NEED NEW WASTE TANK.SDR UALA2013070904782Drain Line · cloggedBUSINESS CLASS GALLEY DRAIN CLOGGED. FOUND CLOGGED BETWEEN SINK AND DRAIN STRAINER. HAD TO STOP WORK DUE TO CATERING AMD AC MOVE. IS FIRST CLASS GALLEY DRAIN CLOGGED.SDR UALA2013062504394Hose · leakingLAVATORY TOILET HOSE FROM PUMP TO BOWL HAS A LARGE HOLE. SECURED AND SAFTIED ALL HOSES AND ATTACH POINTS. LAVATORY LEAK AND OPS CHECKED OK.SDR USAA2013061200024Unknown · odorPASSENGERS IN LAST ROW AND AFT GALLEY COMPLAINED OF DIRTY/MUSTY ODOR. 6 PASSENGERS AND 3 F/A`S EXPERIENCED DIZZINESS/NAUSEA AND 1 F/A ALMOST FAINTED. ACCOMPLISHED TROUBLESHOOTING, AIR QUALITY JOB CARDS, FOUND AFT LAVATORIES TO BE SOURCE OF ODOR. ACCOMPLISHED SDR UALA2013050103049Tank · blockedLAVATORY TANK NR 3, CABIN INDICATOR SHOWS FULL WHEN LAVATORY SERVICE CLAIMS TANK EMPTY. TANK WAS DUMPED TWICE, VERIFIED TO HAVE NO LEAKS. REMOVED BLOCKAGE FROM WASTE TANK NR 3, AMM 38-32-00, OPS NORMAL.SDR UALA2013050203068Line · leakingLAVATORY SERVICE REPORTED WHEN SERVICING LAVATORY WITH BLUE WATER, FLUID STARTED TO COME OUT OF DRAIN HOLE IN FRONT OF SERVICE PANEL. REPLACED FILL LINE FOR FWD TANK FROM FILTER TO PRECHARGE SHUTOFF VALVE IAW MM 20-11-00 AND LEAK CHECKED GOOD.SDR UALA2013050103042Tube · leakingAFT LAVATORY "Y" TUBE ABOVE SERVICE PANEL IN AFT CARGO BAY AREA IS LEAKING. BLUE LAVATORY WATER DRAINING FROM AFT LAV ACCESS PANEL REMOVED DAMAGED "Y" TUBE. REPLACED RUPTURED LAVATORY WASTE Y DUCT AT AFT DUMP VALVE CHECKED OKAY.SDR UALA2013050203058Motor · faultyAFT FORWARD LAV INOP - LEVEL 1. DUE TO REPEAT GRIPES OF AFT FORWARD LAVATORY FLUSH MOTOR WEAK OR NEEDS SERVICE, PLEASE ACCOMPLISH MM 38-32-00,PG 501,TOILET SYSTEM TEST. LOOK FOR POSSIBLE LEAKS AT THE FILL AND DRAIN LINES. IF NO DISCREPANCIES FOUND THEN REPLSDR UALA2013042202777Blower · inoperativeFOUND SYSTEM 2&3 BLOWER INOP. CHANGED BLOWERS PER MM. VACUUM STILL VERY WEAK. REF FOR MORE INFO SEE DF0640. PANELS IN AFT PIT ARE OPEN FOR MAINTENANCE. UPDATED MR NUMBERS.SDR UALA2013042202779Hose · leakingBLUE FLUID LEAKING FROM BELLY DRAIN JUST FWD OF SERVICE PANEL WHEN RINSING LAV TANKS. REPLACED FILL LINE HOSE PER AMM 38-00 AND LEAK CHECKED.SDR UIEA2013041900246Wastegate Valve · stickingLAV D WASTE FLAP STICKING AND WILL NOT RETURN TOP CLOSED POSITION. WASTE COMP. DOOR LATCH NOT WORKING AND LOOSE HARDWARE. CLEANED LAV D WASTE FLAP HINGE- OPS CHECK GOOD. REPLACED MISSING SCREWS IN TRASH DOOR AT LAV D AS NEEDED - DOOR OPS CHECK GOOD REF 25-0SDR UALA2013041602600Lavatory · shutdownLAVS SHUTDOWN, FLT DIVERTED.SDR UALA2013041202511Control Module · faultyINOP FORWARD TANK LIGHT ON REAR FLT ATTEND PANEL. REPLACED ALTITUDE PRESSURE SWITCH (SEQ 9312011) LOGIC CONTROL MODULE AND CHECK VALVE (SEQ 9312012) AIRCRAFT RETURNED TO GATE. BITE CHECK OF NEW LOGIC CONTROL MODULE SHOWED LOGIC CONTROL MODULE IS BAD. REPLACSDR UALA2013041202504Rod · defectiveWASTE HOLDING TANK VALVE HANDLE WILL NOT MOVE THE DUMP VALVE. ROD ASSY PARTS.SDR UALA2013040902363Control Unit · faultyH2O POURING OUT FWD LAV INTO COCKPIT. REMOVED AND REPLACED FLUSH CONTROL UNIT REF AMM 38-31-12. REMOVED AND REPLACED RINSE VALVE FWD LAV 'A'. OPS AND LEAKS CHECK GOOD. NO FURTHER CLEAN UP IS REQUIRED.SDR UALA2013040902370Toilet · failedLAVATORY ISSUES, FLT DIVERTED. LEFT REAR INBD DISABLED TOILET WAS INOPERATIVE AND BLOCKED. ALL OTHER TOILETS OPERATED OK AND TANKS BOTH SHOWED LESS THAN HALF FULL. CLEARED BLOCKAGE FROM TOILET. REPLACED TOILET SEAT ASSEMBLY AND CARRIED OUT LEAK CHECKS SDR RAIA201304040002Cup · corrodedDURING SCHEDULED MAINTENANCE THE LAV WASTE CUP ASSY WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE LAV WASTE CUP ASSY.SDR UALA2013040302187Toilet · obstructedAFT LAV OVERFLOW, RTFL. CLEARED DEBRIS AND TANK DRAINED NORMALLY. FILLED AND DRAINED SEVERAL TIMES. BLUE WATER CONTAINED IN LAV. CLEANED AREA LAV, OP CKS GOOD.SDR UALA2013032701968Blower · faultyAFT LEFT, AFT LEFT CENTER AND RIGHT BUSINESS LAVS WILL NOT FLUSH. NO VACUUM, FORWARD SYSTEM. VACUUM AVAILABLE ABOVE 16K FEET. REMOVED AND REPLACED FWD SYSTEM 2 BLOWER PER MM, OPS CHECK NORMAL.SDR HALA2013031900030Lavatory · cloggedAIR TURNBACK, LAVATORY 3L OVERFLOWING INTO CABIN AND GALLEY. REMOVED CLOG OPS CHECKS OK.SDR UALA2013030701357Toilet · cloggedAFT LEFT LAV OVERFLOWING. REMOVED DEBRIS AND UNCLOGGED LAV, OPS CHECKS OKAY.SDR UALA2013030501308Controller · faultyCREW REFUSAL. MUST FIX DF0451 PRIOR TO DEPARTURE. TOILET VACUUM MOTOR STARTED RUNNING CONTINUOUSLY AFTER TAKEOFF. REMOVED AND REPLACED LAV BLOWER MOTOR CONTROLLER.SDR UIEA2013022600106Waste Tank · inoperativeDUE LAVS INOPERATIVE, DIVERED, FWD LAV TANK SERVICED, MID CTR, MID RT & AFT LT OPS NORMAL IAW AMM 12-17-01 TRANSFERED AFT WASTE TANK TO MDDR 38112 CT FWD , MID LT; AFT RT ARE INOPERATIVE.SDR UALA2013022501125Toilet · leakingF/C LAV LEAKING, RTFL. REPLACED TOILET ASSY PER AMM. HOT WATER HEATER TURNED ON. NEED TO CHECK BELOW DECK TO CONFIRM WATER FROM LAV DID NOT LEAK BELOW DECK. NO EVIDENCE OF WATER SEEPAGE INTO R&E COMPT.SDR UALA2013021900989Duct · obstructedBOTH AFT LAVS INOPERATIVE, FLIGHT DIVERTED. REMOVED LARGE BLOCKAGE OF PAPER TOWELS FROM TOP INLET TO WASTE TANK. OPS CHECKED EXCELLENT.SDR UALA2013021901009Flapper Valve · brokenAFT LAV DUMP VALVE FLAPPER ON WASTE DRAIN IS BROKEN OFF. REMOVE ALL BOLTS OUTSIDE HOLDING LAV DOOR FLAPPER. NEEDS REPLACEMENT OF FLAPPER ASSY PARTS ON TOOL CART IN BACK OF PLANE. REMOVED VALVE PER AMM. VALVE NEEDS TO BE INSTALLED AFTER HEATER GASKET HAS BESDR UALA2013021100779Drain Mast · obstructedFWD LAVATORY OVERFLOWED, RETURNED TO FIELD. FOUND PLASTIC CAP IN FWD DRAIN MAST. REMOVED CAP, CLEARED DRAINS. CHECKED FWD SINKS AND GALLEY DRAINS FOR CLOGS, OPS CHECKED GOOD.SDR UALA2013020500714Toilet · leakingFORWARD LAVATORY HAS A LARGE WATER LEAK. REPLACED TOILET ASSY.SDR QXEA2013013100203Drain Mast · inoperativeLAVATORY DRAIN MAST HEAT INOPERATIVE. REMOVED PANELS TO GAIN ACCESS TO DRAIN MAST AND SPLICES REF AMM 25-25-01-000-802 AND 53-23-01-000-801. REMOVED AND INSTALLED NEW DRAIN MAST IAW AMM 38-32-00-000-801 AND 38-32-00-400-801.SDR R61A201301300138Service Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE WASTE SERVICE BOX CORRODED. MAINTENANCE REMOVED AND REPLACED THE WASTE BOX IAW EMB 170 SRM 51-43-03, AND 51-43-04. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR ASAA2013012793768Valve · stuckAFTER TAKEOFF FAS CALLED WITH VERY LOUD AIR NOISE FROM AFT RT LAV. VERIFIED FLUSH VALVE ON RT AFT LAV IS STUCK OPEN. REMOVED AFT RT TOILET ASSY REF MM 38-32-01-000-838-002 INSTALLED SERVICEABLE AFT RT TOILET ASSY REF MM 38-32-01-400-838-002.SDR UALA2013012200378Drain · leakingBLUE WATER LEAKING FROM LOWER FUSELAGE AFT DRAIN HOLES. WATER COMING FROM AFT FWD LAV TANK. DISCONNECTED APU AIR DUCT AND EQUIP COOLING DUCT IN RIGHT AFT AREA OF AFT CARGO PIT TO FACILITATE REMOVAL OF WASTE TUBE ELBOW. REPLACED ELBOW DRAIN HOLES.SDR ASAA2013010693635Unknown · unknownDURING FLIGHT, LAVATORY INOPERATIVE LIGHT ILLUMINATED ON AFT F/A PANEL, DEACTIVATING ALL TOILETS FROM FLUSHING OR DRAINING. ON ARRIVAL SERVICE PERSONNEL NOTED LARGE AMOUNT OF WASTE WAS DUMPED. PERFORMED TOILET FLUSH SYS. ALL TOILETS DO NOT FLUSH REF MM 38-3SDR UALA2013010700086Module · faultyINVALID DATA SHOWS FOR WASTE. MSG IS 23-024-03 REPLACED OEU 3-1-1 NO HELP, REINSTALL ORIGINAL OEU. LAVS 1L CENTER ,2L OUTBD, 3L FWD AND 4R OUTBD ALL FLUSH NORMAL. NO LEAKS AT WASTE TANKS. NEEDS ZMU MR23319 NONE AT IADJL. RPL'D ZMU NR 3. INDICATION CHECKSSDR ASMF201301001Valve · leakingDURING TRANSIT CHECK, MX DETECTED A WATER LEAK IN THE FORWARD LAVATORY FOR RINSE VALVE. FORWARD RINSE VALVE WAS REPLACED IAW MM 38-32-01, TESTED CORRECT.SDR UALA2012122407382Unknown · malfunctionedALL WASTE TANKS SHOW INVALID DATA ON CACP - CSCP. TRIED CYCLING ZMU CBS, NO HELP. SEE PREVIOUS HIS ZMU 3 HAS JUST BEEN REPLACED. NO LEAKS ON SYSTEM AND ALL LAVS OPERATE NORMALLY. DF PLACARD ON CSCP. NOTE JUST PRIOR TO TRANSMITTING DEFERRAL ALL INDICATIONSSDR HNAA2012121901118Clamp · corrodedLAVATORY FLOOR DRAIN LOWER HOSE CLAMP CORRODED. FOUND SMALL SECTION OF CLAMP CORRODED. CLEANED AS REQUIRED.SDR UALA2012121407241Unknown · leakingBLUE WATER LEAKING FROM WEEP HOLE UNDER AFT PIT. AFT PIT PANELS WAS OPENED BY PREVIOUS SHIFT, DID NOT FIND ANY SOLID EVIDENCE OF BLUE WATER LEAK (WITH THE DUMP VALVES OPENED, HAD LAV SERVICE PERSON CYCLE THRU 30-40 GALS THRU FILL LINE. NO LEAKAGE NOTED. LAVSDR R61A201210230620Structure · corrodedWHILE IN HEAVY CHECK CORROSION WAS FOUND ON WASTE BOX. WASTE BOX WAS REMOVED AND REPLACED PER EMB 190 SRM WHILE IN HEAVY CHECK.SDR CHQA20121023401Housing · corrodedDURING INSPECTION, THE LAVATORY DUMP HOUSING WAS FOUND TO BE CORRODED UNDER THE DUMP CHUTE FLANGE. THE LAVATORY DUMP HOUSING WAS REPLACED IN ACCORDANCE WITH AMM 38-32-04.SDR UALA2012101205819Panel · damagedINTERIM REPAIRS TO AFT LAV PANEL COMPLETED PER ECRA 534101022. WELDING REPAIR LOOKS GOOD AND MEETS ECRA 534101022. ACP NDT PER 51-10-21 INTERNAL AND EXTERNAL INSPECTION FOUND NO CRACKS. ACP INTERNAL HFEC AND OPEN HOLE INSPECTIONS NO CRACKS FOUND.SDR UALA2012100905728Tube · cloggedAFT- AFT LAV DUMP TUBE CLOGGED. CLEARED DUMP TUBE WITH VACUUM TRUCK.SDR UALA2012092705458Toilet · noisyCREW REPORT: FORWARD AFT LAV EXTREMELY LOUD - AS IF A PRESSURE LEAK. CABIN PRESSURIZATION SHOWS NORMAL. REPLACED THE TOILET ASSY IAW AMM AND TOILET FLUSHES NORMALLY.SDR UALA2012091005063Duct · cloggedTOILET DOES NOT FLUSH, IN LAV NR 111 AIRPLANE ABOVE 16000FT ALTITUDE. SEE CABIN MAINTENANCE FORM FOR LOCATION CODES. LAV FLUSH INOP ON GROUND ALSO. BOWL IS EMPTY SUSPECT CLOGGED DUCT ALL THE OTHER LAVS CHECK OKAY. CLEANED WASTE LINE AND UNCLOGGED, WASTE SYSDR UALA2012091005078Drain Line · cloggedFIRST CLASS GALLEY DRAIN CLOGGED. CLEANED LINE - OPS OKAY.SDR ASAA2012090592844Tank · obstructedALL LAVATORIES INOPERATIVE. PERFORMED TROUBLESHOOTING. R & R CONT LEVEL SENSOR IAW AMM 38-30-00-810-809 & 38-33-02-400-801. WHEN SENSOR REMOVED FOUND LAVATORY TANK PLUGGED WITH CLOTH TOWELS. REMOVED ALL BLOCKAGE FROM DRAIN VALVE. DRAINED , FILLED, CLEANEDSDR VNAA2012090400019Motor · malfunctionedCREW REPORTED LAVATORY SMOKE DETECTOR MESSAGE WITH SMOKE VISABLE. MAINTENANCE TROUBLESHOT, REMOVED AND REPLACED THE LAVATORY WASTE MOTOR ASSEMBLY USING THE AIRCRAFT MANUALS. OPERATIONAL CHECKS WERE PERFORMED USING THE AIRCRAFT MAINTENANCE MANUALS. AIRCRAFT SDR UALA2012082104661Unknown · malfunctionedEN ROUTE LAVS STARTED TO OVERFLOW. LAV WASTE LEVEL INDICATOR SHOWS FULL. INDICATOR SHOWS OK BEFORE AND AFTER SERVICING LAVS. SENSOR CLEANED OFF FROM LAST SEVERAL DAYS SERVICING.
Back to JASC 3830