JASC 3830
Service difficulty reports · 747
Reports filed under 3830 · Waste Disposal System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3830' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2011030700132Circuit Breaker · pulledREF PREVIOUS L/P, MEL 38-02, AFTER T/O, LAVS ON BOARD A/C STILL DID NOT FUNCTION/OPERATE AT ALL, AS PER MEL GUIDELINES. UNABLE TO COMPLETE FLIGHT TO DESTINATION. AIR RETURN TO EWR. INSPECTED P91 PANEL FOR DDPG COMPLIANCE AND FOUND C/B C-11(VAC WASTE CONT) PSDR UALA2011020300578Sensor · faultyFWD WASTE TANK FAILURES. DUE TO NUMEROUS LAV FAILURES IN FLIGHT PLEASE COMPLETE THE FOLLOWING CALLOUT BEFORE FURTHER REVENUE FLIGHT. REPLACE BOTH POINT LEVEL SENSORS ON THE FWD WASTE TANK CHECK ALL CONNECTORS AND WIRES ASSOCIATED WITH THE WASTE TANK LEVEL SENSSDR REXA201100071Fastener · brokenDURING REPLACEMENT OF THE GALLEY HEATED (FORWARD) DRAIN MAST (P/N 4E3160-1), ONE OF THE SIX ATTACH SCREWS (MS35191-292) WAS BROKEN OFF INSIDE THE UNDERLYING NUT PLATE. TEMPORARY REPAIR IAW STS ENGINEERING EA 9-2011-24. REPEAT INSPECTIONS EVERY 150 FLIGHT HOUSDR UALA2011011700243Line · inoperativeALL LAVS INOP, RTFL. NO LAV-FLUSH FLUID AVAILABLE IN ECONOMY OR BUSINESS LAVS. ONLY 1ST LAV WORKS CORRECTLY. ALL LAVS IN BUS CLASS AND ECONOMY ARE DRY FLUSH ONLY. NO RINSE WATER WITH FLUSH. TRIED PRIMING BY POURING WATER INTO TOILET BOWL-NO HELP. NORMAL WSDR UALA2011011200165Lavatory · underservicedLAVS INOP, FLIGHT DIVERTED. APPEARS FWD TANKS (LT AND RT) ARE SHUTDOWN. NO AHM DATA SHOWING ANY FAILURES. SENSOR "INOP" LIGHTS ARE ILLUMINATED ON ACCESS PANEL (R2 DOOR) FOR LAV BOTH FWD LAV TANKS. LAVATORY TANKS SERVICED PROPERLY AND ALL LIGHTS WENT OUT WISDR IPXA0M63928Tank · leakingLAV TANK LEAKED INTO E&E COMPARTMENT CAUSING WIRES TO SHORT AND DAMAGE TO SEVERAL COMPONENTS. R & R WASTE TANK ASSY REF MM CHAP 38-31-02-4 THROUGH 3E(1)(D) XFER TO LMECA 020807. REF L/P 423363/3 FOR C/A. R & R THE FOLLOWING: AUX IRU, NR2 ADF RECEIVER, NR2 FSDR C2XA10SH404Support · corrodedSHV - DURING C-CHECK TOILET DUMP VALVE SUPPORT HAS CORROSION. REMOVED AND REPLACED TOILED DUMP VALVE SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR YENA20101022147Generator · malfunctionedFLT 1795 FLL-CUN - SPORADIC AFT LAV OPERATION WITH NO PERSON IN THE LAVATORY COMBINING WITH ODOR OF MELTING PLASTIC AND STRONG ELECTRICAL. ACCOMPLISHED TSM 25-30-00-801A.IDENTIFIED THE AFT LAVATORY VACUUM GENERATOR RUNNING CONTINUOUSLY, DEACTIVATED AFT VACUUMSDR CA101008002Relay · burnedAFTER ABC STRUCTURAL INSP AND FOLLOWING SEVERAL ENGINE RUNS, WHEN THE ACFT WAS CONNECTED TO GROUND POWER DURING SERVICING IN THE HANGAR, THE AME WORKING ON THE ACFT NOTED DENSE SMOKE COMING OUT OF THE ENGINE NACELLE AND LANDING GEAR AREA. ACFT POWER WAS REMOVSDR UALA2010090803322Drain · cloggedFWD GALLEY SINK DRAIN LEAKING BEHIND GALLEY. GALLEY HAS TO BE REMOVED TO ACCESS LEAK. DRAIN SYS MADE INOPERATIVE. FWD GALLEY AND FWD LAV DRAIN CLOGGED, WATER BACK-UP, OVERFLOW BEHIND AND UNDER CHILLER. NO LEAKS NOTED. FOUND BAD SECTION OF HOSE IN E&E COMPT SDR UALA2010083003211Lavatory · underservicedWATER LEAK IN CABIN. FLIGHT DIVERTED. RIGHT AFT LAV WASTE TANK SHOWS FULL AND LAVS 124,101 AND 102 HAVE SHUT DOWN. SERVICED RIGHT AFT LAV WASTE TANK. OPS CHK OK. ACP WATER LEAK CHECKS AROUND THE LAVS AND NO LEAKS FOUND. CLEANING AND DISINFECTANT BY SERVICE AISDR YENA20100828120Line · misinstalledFLT 41 JFK-MCO, PUTRID ODOR COMING FROM AIR VENT AT CABIN ROWS 15 AND AFT, STRONGEST ODOR FROM AFT GALLEY GASPER AIR VENT. FOUND AT LAV 'D', THE AIR OUTLET SUPPLY LINE AND THE WASTE WATER DRAIN LINES TO BE INSTALLED BACKWARDS, INSTALLED CORRECTLY AND DRAINED SDR MASA2010080900865Unknown · odorW/FLUSH FWD LAV SMELL LIKE BURNT PLASTIC. MX RE-SERVICED LAV, OPS CHECK GOOD.SDR UALA2010071902563Toilet · leakingWATER LEAK AT MID CABIN LAV, RTFL. LEAK FROM COMMODE ASSY. REPLACED LEAKING TOILET ASSEMBLY. OPS ARE NORMAL.SDR R61A20100253Stand Off · corrodedWHILE AC WAS IN FOR HEAVY CHECK, LEVEL TWO CORROSION WAS FOUND ON AFT SIDE OF THE LAV DUMP BOX STANDOFF. MAINTENANCE REMOVED CORRODED STANDOFF, FABRICATED NEW STANDOFF AND REPLACED ON AC PER EMB SRM. AC STILL OUT OF SERVICE FOR REMAINDER OF HEAVY CHECK.SDR QXEA2010051800305Toilet · leakingAFTER ROTATION LAV FLUID LEAKED FROM UNDERNEATH LAV DOOR. RETURNED TO THE FIELD. LANDING UNEVENTFUL. REMOVED TOILET SURROUND, CLEANED RESIDUAL FLUID, REINSTALLED SURROUND, AND SEALED WITH WHITE RTV 102. RETURNED TO SERVICE.SDR UALA2010042201343Module · faultyLT FWD WASTE TANK INDICATION INOP ON DOOR 2R FA PANEL. WASTE TANK MODULE REMOVED DUE TO ELECTRICAL SMELL AND SECURED BY TAPE ON THIS AREA. CONFIRMED LAV SERVICE DONE BY CLEANER AND AFFECTED LAVS FLUSH SYS, OPS CK'D OK. REMOVED MODULE PLACED IN DOOR 2L PARTS BSDR YENA20100311037Generator · defectiveFLT JB724 WEIRD GRINDING NOISE IN BACK GALLEY WHEN TOILETS FLUSHED WITH A SMOKE ODOR. AFTER LANDING JFK MX INSPECTED AREA AND FOUND VACUUM GENERATOR TO BE AT FAULT. INSPECTED FOR SMOKE PER AMM TSM 24-00-00-810-823, ODOR WAS RELATED TO THE VACUUM GENERATOR. SDR DL76G100479Module · malfunctionedDURING CRUISE -RT FWD - MID AFT AND AFT LT LAV INOP, FOUND SYS 2 WASTE LVL IND SHOWS FULL ON AFT PNL SERVICED AND FLUSHED BOTH LAV SYS. ALL LAVS OPS NORMAL. R & R SYS 2TANK LOGIC CONTROL MODULE IAW AMM AS PRECAUTION. SVC ALL LAVS WITH VINEAR. ETOPS CATEGOSDR C2XA10SH069Support · corrodedSHV - DURING C-CHECK WASTE DRAIN VALVE SUPPORT HAS CORROSION. REMOVED AND REPLACED SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR DL76L092038Tank · failedALL LAVS INOPERATIVE AFTER TAKEOFF. FOUND BOTH AFT AND FWD LAV TANKS INDICATING FULL UPON ARRIVAL. DRAINED TANKS AND BOTH NOW INDICATE EMPTY. FLUSHED TANKS AND PERFORMED OPS CHECKS. ALL LAVS OPS OK. ETOPS CATEGORY 'E' PROBLEMS WITH SYS CRITICAL TO ETOPS.SDR C2XA09SH438Support · corrodedSHV - DURING C-CHECK, LAV WASTE DRAIN VALVE SUPPORT CORRODED. REMOVED AND REPLACED LAV WASTE DRAIN VALVE SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH422Bowl · corrodedSHV - DURING C-CHECK LAV PAN CORRODED (LEVEL 2 LOCAL) FWD WASTE DRAIN VALVE. MAINTENANCE REMOVED AND REPLACED WASTE DRAIN DUMP BOWL ASSY IAW EMB-145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH411Support · corrodedSHV - DURING C-CHECK, TOILET WASTE DRAIN VALVE CORRODED. REMOVED AND REPLACED TOILET WASTE DRAIN VALVE SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR DL76G091745Drain · cloggedBROWNISH SEMI SOLID PRODUCT CAME OUT NEAR 1L DOOR. DRAIN CLOGGED BELOW FLOOR LEVEL. SOLID ON FLOOR CLEANED WITH ABSORBENT FROM UPK KIT. DRAIN CLOGGED BELOW FLOOR LEVEL. BLOCKED OFF GALLEY DRAIN AND FIRST CLASS SINK SHUT OFF. FWD TO MCO AND PLACARD PER MELSDR C2XA09SH410Support · corrodedSHV - DURING C-CHECK, LAV WASTE DRAIN VALVE SUPPORT CORRODED. REMOVED AND REPLACED LAV WASTE DRAIN VALVE SUPPORT IAW EMB 145 SRM 51-40-02. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA09SH399Support · corrodedSHV - DURING C-CHECK DUMP VALVE SUPPORT CORRODED (LEVEL 2 LOCAL) "INTERNAL". MAINTENANCE REMOVED AND REPLACED WASTE DRAIN DUMP VALVE SUPPORT ASSY IAW EMB-145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR UALA2009083102730Lavatory · inoperativeLAVS SHUTDOWN, FLT DIVERTED. LAVS WERE NOT SERVICED IN ORD. SERVICED ALL LAV TANKS, CHECKED ALL TOILETS AND OPS OKAY.SDR UALA2009081702520Lavatory · overflowLAV OVERFLOW, FLIGHT DIVERTED. SERVICED ALL LAVS.SDR AALA20090809MIA01Blower Motor · faultyMIA - CREW REPORTED LAVATORIES WOULD NOT FLUSH IN FLIGHT. EMERGENCY DECLARED RETURNED MIA WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND SENSOR FAULT AND BLOWER MOTOR POPPING CIRCUIT BREAKER. REPLACED BLOWER MOTOR. SYSTEM GROUND CHECKED NORMAL OPESDR C2XA09SH240Support · corrodedSHV - DURING C-CHECK WASTE VALVE SUPPORT HAS CORROSION (LEVEL 2 LOCAL). MAINTENANCE REMOVED, REPLACED AND COMPLETED INSTALLATION OF NEW WASTE VALVE SUPPORT IAW EMB-145 AMM 38-32-04 AND SRM 51-10-03. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR USAA20090427SB068Drain Line · unsecureEN ROUTE FROM GEG TO PHX, CREW REPORTED SOAPY WATER LEAKING ON THE FORWARD LAVATORY FLOOR WITH ASSOCIATED LOSS OF SOME NAVIGATIONAL AND AUTO PILOT RELATED ITEMS ON THE FIRST OFFICER'S SIDE OF AIRCRAFT. FLIGHT DIVERTED TO LAS AND LANDED WITHOUT FURTHER INCIDENSDR UALA2008111305933Toilet · intermittentLAVATORY TOILET BOWL FLUSH SYSTEM INOPERATIVE AT AFT CABIN LIGHT AFT LAV. CREW COMMENTS: BOTH AFT LAV TOILETS FLUSH SYSTEMS ARE INTERMITTENT. WASTE TANK SERVICED. RESET PWR TO LAVS. ALL LAVS FLUSH NORMALLY. NO HISTORY IN AMIS.SDR 2008UALA05933Toilet · intermittentLAVATORY TOILET BOWL FLUSH SYSTEM INOPERATIVE AT AFT CABIN LIGHT AFT LAV. CREW COMMENTS: BOTH AFT LAV TOILETS FLUSH SYSTEMS ARE INTERMITTENT.SDR DL76L081246Fitting · cloggedA/C RTB DUE TO WATER COMING OUT OF AFT FLOOR DRAINS WHENEVER WATER IS POURED INTO AFT GALLEY DRAINS. ALSO HAD A PROBLEM WITH A WATER LEAK FROM A FWD GALLEY COFFEEMAKER. TURNED OFF WATER IN AFT GALLEY AND DEFERRED WATER PER MEL. PUT FWD COFFEEMAKER ON NEF. SDR 2008UALA03632Valve · stuckFWD LAV TANK INDICATING FULL. HALF OF LAVS NOW NOT WORKING. ECONOMY LAVATORY BY DOOR 2L TOILET WILL NOT STOP FLUSHING, FOUND STUCK VALVE. USED A WET PILLOW PER SAM. FLUSHED BOTH TANKS THRU SEVERAL TIMES WITH HONEY-BEE AND PRESERVICE. RESET TOILET TANK LOGICSDR HALA0800611Flush Motor · inoperativeAIRCRAFT DIVERTED INTO LAX - ALL LAVATORY FLUSH MOTORS INOP. AIRPLANE WAS 16000 FEET OR ABOVE. FOUND TANKS LIGHTS ILLUMINATED AT AFT ATTENDED PNL. SERVICED AND RESERVICE IAW AMM 12-17-01. OPS CHECK NORMAL. OK FOR SERVICE.
SDR 2008UALA02766Tank · fullMID LAV FULL PER CREW. FLT DIVERTED. SERVICED LAVS, OPS NORMAL.SDR DALA1202200931Seal · damagedFWD & AFT WASTE DRAIN VALVE SEAL REPAIRED IAW ERA 468214-14.SDR SAJFCALS097010Waste Tank · damagedINSPECTION FOUND ACFT B-18617 WASTE TANK OUTLET FLANGE DAMAGED. WASTE TANK OUTLET FLANGE BROKEN-OFF, REPLACE NEW WASTE TANK. MANUFACTURER AND VENDOR EDO WILL CHANGE WASTE TANK DRAIN FITTING MATERIAL, FROM NYLON TO STAINLESS STELL THAT WOULD GREATLY IMPROVE THSDR 08FDEA00879Waste Tank · leakingFWD ELECTRONIC COMPARTMENT RIGHT SIDE HAS EVIDENCE OF LEAK; BLUE WATER THROUGHOUT THE E/E COMPARTMENT. REMOVED AND REPLACED THE LAV TANK ASSY P/N 1-119095-55; S/N 10-52-05 IAW DC-10-30 AMM 38-31-05-02. COMPLIED WITH EA 8-3831-116953 PT 1; " WATER AND WASTSDR 2008UALA00030Dump Valve · obstructedFLIGHT DIVERTED DUE TO FORWARD LAVATORY OVERFLOW. FOUND FOREIGN OBJECT IN DUMP VALVE ALLOWING FLUID TO BYPASS VALVE. REMOVED OBJECT.SDR HNAA0800072Service Panel · corrodedCORROSION FOUND ON LAVATORY SERVICE PANEL. REPLACED LAVATORY SERVICE PANEL.SDR 2007UALA04248Toilet · inoperativeFOUR OUT OF EIGHT LAVS INOP THE 4 GOOD LAVS FLUSH CLEAR FLUID. *S/D* AFTER 10 DAYS & CONSIDERABLE TROUBLESHOOTING & TANK SERVICING, DETERMINED LEFT AFT TOILET HAD VALVE PROBLEM WITH CONTINUOUS FLUSHING PROBLEM. REPLACED TOILET ASSEMBLY. LAV SYSTEM CHECKEDSDR UIEA200700358Drain Valve · corrodedDURING SCHEDULED TIME REMOVAL OF THE TOILET SERVICE DRAIN VALVE FOUND HEAVY CORROSION ON THE BRACKET ABOVE THE PAN AND SERVICE DOOR INSTALLATION. REMOVED ALL BRACKET THAT HAD CORROSION DAMAGE. REPAIRED INTERNAL STRAPS PER SRM 53-30-03. REPAIRED INTERNAL SECSDR 2007UALA02533Drain · cloggedRTFL DUE TO AFT LAV TANK INOP LIGHT ILLUMINATED. CREW REPORTED LAVS FULL AND OVERFLOWING. RETURNED TO FIELD DUE TO NO FUNCTIONING LAVS. FOUND DRAINS CLOGGED. UNPLUGGED DRAINS. FOUND 9 CLOTH NAPKINS, 2 RUBBER LAV DOOR SEAL, AND 2 PIECES OF POLYURETHANIC SDR 2007UALA02326Flapper Valve · stuckFLIGHT DIVERTED DUE TO ALL LAVATORIES NEED SERVICING. MID LAV TOILET FLAP STUCK. SERVICED MID LAV FLAPPER TO UNSTUCK POSITION.SDR 2007UALA02314Toilet · malfunctionedFLIGHT DIVERTED DUE TO INABILITY TO FLUSH BOTH AFT LAVS.SDR HNAA0700133Drain Line · corrodedCORROSION FOUND ON LAV DRAIN TUBE FLANGE.SDR 2007UALA01512Lavatory · inoperativeFLIGHT DIVERTED DUE TO ALL LAVATORIES GOING INOP. HISSING SOUND NOTED BELOW 1R. TRIED TROUBLESHOOTING TO NO AVAIL. [SUP 06-06-07] EXISTING SERVICE BULLETIN 747-38-2109 DIRECTS TO REPLACE RELAY R8432 (LEVEL SENSING TRANSFER RELAY). THIS RELAY IS IDENTIFIED
Back to JASC 3830