JASC 3830

Service difficulty reports · 747

Reports filed under 3830 · Waste Disposal System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3830'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR QXEA200700512Timer · malfunctionedDEN - FLIGHT 4277 - ON TAXI LAVATORY RUNS ALL THE TIME AND IS LEAKING FLUID. RETURNED TO THE GATE. MAINTNEANCE REPLACED THE GASKETS AND TIMER. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.Apr 5, 2007 · N606QX · Cndair CL6002C10SDR HALA0700150Valve · stuckATB - PER FLT ATTNEDANT- AFT WASTE TANK AFT F/A PANEL DOES NOT TEST PROPERLY. REFERENCE ITEMS 93, FOUND LAV H FLUSH VALVE STUCK IN THE OPEN POSITION, SECURED LAV H VALVE CLOSED. ALSO, RECALIBRATED AFT WASTE TANK CONTINUOUS LEVEL SENSOR PER AMM 38-33-00 TEST Apr 3, 2007 · N583HA · Boeing 76733ASDR ANCF200600044Toilet · malfunctionedPILOT REPORT: ALL TOILETS FAILED TO FLUSH, AIRPLANE WAS 16,000 FT OR ABOVE. PERFORMED INSPECTION AND CHECK, TOILET SERVICE ACCOMPLISHED. WASTE TANK WAS DRAINED AND CLEANED IAW AMM 38-32-00. OPERATIONAL CHECK WAS PERFORMED ON GROUND, IT SHOWED NORMAL CONDITJan 23, 2007 · N948AV · Boeing 7673Y0SDR FCPR20060027Heater · burnedAFT TOILET RELIEF TUBE HEATER ELEMENT FAILED WITH EXTERNAL POWER APPLIED BURSTING INTO FLAMES. IPC REFERENCE 38-30-00 FIG 3 ITEM 16.Dec 15, 2006 · N523BT · Cessna 525ASDR TRAX200601027Motor · odorLAV MOTOR HAS A ELECTRICAL SMOKE ODOR.Nov 14, 2006 · N851AS · Cndair CL6002B19SDR SIMA200631901Receptacle · corrodedDISC - FOUND LAVATORY RECEPTICLE CORRODED ON SKIN ATTACHMENT. REMOVED AND REPLACED CUP ASSEMBLY IAW EMB SRM 51-40-02. AIRCRAFT RETURNED TO SERVICE.Oct 23, 2006 · N642AE · Emb EMB145LRSDR CALA0600385Drain Mast · corrodedCORRODED LAVATORY DRAIN MAST AT STA 986.5-1006, STR 24L-25L. REPLACED MAST PER SRM 51-40-02.Oct 11, 2006 · N14336 · Boeing 7373T0SDR SWAA063503Toilet · leakingDECLARED EMERGENCY, BURNING SMELL REPORTED IN AFT GALLEY, TURNED POWER OFF, SMELL DISSIPATED. PRIOR TO LANDING, THE FRONT LAV WAS LEAKING AROUND THE BASE, ALL WATER VALVES TURNED OFF. DURING DESCENT L/E TRANSIT LIGHT ILLUMINATED, THE MACH TRIM FAIL LIGHT ALSSep 15, 2006 · N755SA · Boeing 7377H4SDR DL76G060313Control Panel · unknownAFT WASTE TANK FAIL 4 OF 6 TOILETS FAILED TO FLUSH. PULLED AND RESET C/B R8 ON P11 OVERHEAD PANEL AND M1 ON THE P34 PNL. NO HELP. FOUND AFT TOILETS WASTE FULL, DUMPED SAME. ALL OPS OK. BITE CK OK. REPLACED AFT TANK WASTE TANK CONTROL BOX AND DUMPED ACETIApr 22, 2006 · N394DL · Boeing 767324SDR QXEA200600985Socket · shortedSEA - ON FLIGHT 2299, RETURNED TO GATE, ELECTRICAL SHORT NEAR LAV SERVICE PORT AFTER SPILL OF BLUE JUICE DURING LAV SERVICE. MAINTENANCE FOUND LAV SERVICE INDICATOR SOCKET SHORTED. REMOVED TERMINAL CAPS FROM WIRES AND INSTALLED NEW SERVICE INDICATOR LIGHT INApr 11, 2006 · N614QX · Cndair CL6002C10SDR COMA0660232Reducer · faultyFLIGHT 5145 - EN ROUTE CVG-AVP A NUISANCE SQUEALING NOISE EMITTING FROM GALLEY AREA, FLIGHT RETURNED TO THE FIELD. REPLACED THE GALLEY DRAIN REDUCER.Mar 6, 2006 · N952CA · Cndair CL6002B19SDR IXXA06SMN065SDrain Mast · pluggedDURING ROUTINE C-CHECK INSPECTION, INSTL; FWD LAV DRAIN MAST PLUG AT LOWER CENTER LINE. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 01-19-06, ATI DWG H74-102 REV B DATED 01-19-06, EO SEMAN 2006114 DATED 01-19-06. REMOVED EXISTING DRAIN MAST IAW DC8 SRMFeb 16, 2006 · N722CX · Doug DC872SDR UPS06445929Pan · corrodedCORROSION FOUND AT LAV DUMP PAN AREA. RMVD CORRODED FRAMES & INTERCOSTALS. CKD INNER SKIN-NO DISCREPANCIES - OK TO REPLACE CORRODED PARTS. INSTALLED NEW FRAMES & INTERCOSTALS PER SRM 51-30-02 & EO B747-5330-23587A. DRILLED RT INTERCOSTAL FROM HOLES, DRILLEDJan 9, 2006 · N682UP · Boeing 747121SDR MWEA050123Nipple · brokenLAVATORY FILL/SERVICE NIPPLE WAS DAMAGED. MAINTENANCE REPLACED FRANGIBLE NIPPLE.Nov 14, 2005 · N807ME · Doug DC981SDR UPS05845353Motor · overheatedLAV FLUSH MOTOR OVERHEATED CAUSING SMOKE IN CABIN. REMOVED AND REPLACED LAV TIMER AND FLUSH MOTOR PER MM 20-10-03, 20-16-00-2. OPS CK NORMAL PER MM 38-30-00-1. NO LEAKS NOTED.Sep 2, 2005 · N818UP · Doug DC873FSDR AALA20050483Pan · corrodedMCI - CORROSION FOUND AROUND FORWARD LAVATORY DUMP CHUTE BETWEEN FORWARD LAVATORY SERVICE PAN AND UPPER PAN IN AREA 12 INCHES BY 12 INCHES. REPLACED FORWARD LAVATORY SERVICE PANEL UPPER PAN.Jul 27, 2005 · N702TW · Boeing 7572Q8SDR MALA050507Lavatory · leakingTHE FWD F/A REPORTED THAT BLUE JUICE IS COMING OUT OF THE FWD LAVATORY. F/A NOTED THAT THE FLUID LOOKED LIKE IT WAS COMING OUT OF THE FLOORBOARDS. RETURNED TO MSP. DRAINED FWD LAVATORY.Jun 24, 2005 · N518XJ · Bac AVRO146RJ85ASDR AWXA200500567Dump Valve · obstructedLAS - AIR TURNBACK - FLT 113 - ON CLIMB-OUT OF LAS EN ROUTE TO LAX, VISUAL INDICATION OF LAVATORY BLUE JUICE WAS OBSERVED COMING FROM THE FRONT LAVATORY. MX COMPLIED WITH LAVATORY CLEAN UP PER AWA TASKCARD I1D38001. MX REMOVED PLASTIC BAG FROM DUMP VALVE. OMay 15, 2005 · N160AW · Boeing 7373G7SDR 05FDEA01213Tube · not closedAFT CARGO - REFERENCE EA 1-2520-7-78127 ITEM 39, AFTER REMOVAL OF WASTE TANK AND PLUMBING FOUND VACUUM PUMPS OUTLETS AND TANK DUMP TUBE OUTLET NOT BLANKED. REMOVED AND DISCARD AS PER AMM 20-50-02 AND SMR 51-33-01 VOL II, NEW PANEL AND COVER PLATE FABRICATEMay 5, 2005 · N576FE · Doug MD11SDR 2005UALA00160Housing · brokenMALFUNCTIONING LAVATORY. FWD LAV AT DOOR 3L WASTE COMING UP FROM TOILET BOWL IN FLIGHT AT APPROX 3000 FEET. BLOCKAGE ON THE WASTE LINE DOWNSTREAM TO THE WASTE TANK CAUSED ALL THE LAVS ASSOCIATED TO THE WASTE TANK TO BE INOPERABLE. WITH LAV 3L FLUSH VALVE HOFeb 15, 2005 · N769UA · Boeing 777222SDR 2004UALA01250Toilet · inoperativeDIVERTED DUE TO LAVATORY FLUSH SYSTEM INOPERATIVE. CAUSED BY CLOG / BLOCKAGE IN PLUMBING. SERVICED LAVATORIES, ALL OPS NORMAL. NO FLUID SPILLAGE NOTED.Dec 22, 2004 · N538UA · Boeing 757222SDR MALA040898Dome · corrodedDURING 4K INSPECTION IN BNA, LAVATORY DUMP DOME IS CORRODED OUT OF LIMITS PN 7253680117. DOME HAS BEEN REMOVED AND REPLACED IAW SRM 51-40-21 AND SRM 51-40-22. REFER EAMS WO NR 211236/TASK1534 FOR ADDITIONAL INFORMATION. AIRCRAFT RETURNED TO SERVICE 12/24/04Dec 15, 2004 · N410XJ · Saab 340BSDR DL76L041076Bpcu · inoperativeALL LAVS INOP, NO RINSE WATER, NO VACUUM. A/C DIVERTED TO JFK. REMOVED AND REPLACED RELAY K546 AND THE BPCU. ALL LAVS OPERATE NORMALLY.Dec 2, 2004 · N179DN · Boeing 767332SDR P9RA20040028Waste Tank · overservicedFLT NUMBER 315, SLC-AMA, AT APPROXIMATELY 15,000 FEET, 280 KTS, SMOKE WAS REPORTED IN AFT CABIN BY AFT FLIGHT ATTENDANT STATION. SOURCE AND TYPE UNKNOWN AT THAT TIME. EMERGENCY DECLARED. RETURNED TO SLC. AIRCRAFT INSPECTED AND DETERMINED SAFE TO TAXI TO GATE.Aug 8, 2004 · N960PG · Doug DC983SDR DL76G040194Drain Line · cloggedLEFT FWD LAV FLUID (2 GALS) CAME UP FROM UNDER FLOORBOARDS AT FWD ENTRY DOOR. FOUND FWD LAV, FWD GALLEY AND LEFT DOOR DRAIN LINE CLOGGED. CLEARED LINE, OPS CHECK GOOD. INSPECTED E/E COMP, ALL CHECK NORMAL.Feb 27, 2004 · N152DL · Boeing 7673P6SDR ASAA0480049Flange · crackedOKC - DURING 15K CHECK, FOUND LEFT AFT LAVATORY WASTE CHUTE MOUNTING FLANGE CRACKED. STOP-DRILLED CRACKS AND INSTALLED DOUBLER PER EA 2540-01116. (M)Jan 27, 2004 · N958AS · Doug DC983SDR REXA03009Odor · detectedAMMONIA ODOR/SMOKE COMING FROM LAV REPORTED BY F/A. PERFORMED COMPLETE INSPECTION OF ENTIRE LAV SYSTEM FLUSHED LAV HOLDING TANK TWICE RESERVICED WITH BLUE JUICE. COMPLETE EXTENSIVE GROUND RUN A/C RELEASED FOR FLIGHT. (M)Dec 26, 2003 · N8783E · Cndair CL6002B19SDR AUS20030972Drain Valve · leaking(AUS) FORWARD TOILET DRAIN VALVE LEAKING. FOUND DURING INSPECTION IAW AD/737/25.Sep 20, 2003 · Boeing 73733ASDR AWXA200300927Baffle · cloggedAT CRUISE ALTITUDE EN ROUTE FROM IAD TO PHX FLIGHT ATTENDANTS REPORTED ALL LAVATORIES INOPERATIVE. LAVATORIES WOULD NOT FLUSH PROPERLY. AIRCRAFT DIVERTED TO CMH WHERE MAINTENANCE FOUND EXCESSIVE PAPER TOWELS CLOGGING THE DUCTING AT AN ELBOW TO TANK CONNECTIONAug 15, 2003 · N821AW · Airbus A319132SDR AWXA200300069Lavatory · inoperativeEN ROUTE FROM EWR TO PHX ALL FOUR LAVATORIES BECAME INOPERATIVE, DIVERTED TO ORD. SERVICING PERSONNEL SERVICED LAVATORIES AND DRAINED SYSTEM; RESET CIRCUIT BREAKERS FOR LAVATORY VACUUM SYSTEM, AND CLEARED BLOCKAGE FROM FORWARD LAVATORY; OPERATIONAL CHECK OF FOJan 23, 2003 · N653AW · Airbus A320232SDR 2003UALA00049Sensor · failedFIRE IN THE LEFT AFT LAV UNDER THE SEAT SHROUD. LIQUID LEVEL SENSOR FAILED INTERNALLY CAUSING A FIRE THAT DAMAGED THE SENSOR ITSELF ALONG WITH THE TOILET SEAT SHROUD AND A NEARBY AIR VENT. REPLACED LIQUID LEVEL SENSOR, TOILET SHROUD, AND VENT ASSEMBLY AND RJan 10, 2003 · N551UA · Boeing 757222SDR DL73K021341Check Valve · leakingON ARRIVAL FOUND RIGHT HORIZONTAL STABILIZER LEADING EDGE DENTED. SUSPECT DAMAGE FROM BLUE ICE CAUSED BY LEAKING FWD LAV SERVICE PANEL. REPLACED STAB L/E ASSY AND REPLACED LAV SERVICE LINE CHECK VALVE.Nov 19, 2002 · N245WA · Boeing 737247SDR QXEA0201440Odor · detectedPDX- BAD SMELL WAFTING THROUGHOUT CABIN, SEEMS TO BE COMING FROM THE LAVATORY. FLUSHED AND SERVICED LAVATORY TANK. NO WAFTING SMELL NOTED. NO PARTS REPLACED. AIRCRAFT RETURNED TO SERVICE.Sep 15, 2002 · N401QX · Bombdr DHC8401SDR DL73K021082Diaphragm · missingIRR/ NR 2 ENG HIGH VIBES AT FL 350. FLT DIVERTED TO RDU. VISUAL INSP FOUND EXTENSIVE FAN DAMAGE AND BLUE ICE COMING FROM FWD LAV SVC PANEL AND BLUE STAINS AT NR 2 ENG INLET. NR 2 ENG REPLACED RDU PER TRANS 3T214AD. FOUND FWD LAV TANK FILL VALVE LINE CHECK Sep 12, 2002 · N318DL · Boeing 737232SDR A6WA200230016Sink · corrodedTHE LAVATORY SINK HAS CORROSION AT THE SINK STOPPER. MAINTENANCE REMOVED CORROSION ON LAVATORY SINK STOP IAW DO 328 SRM 51-21-00 AND FIXED REPAIR OF PAINT COATING IAW DO 328 51-93-21. (M)Sep 7, 2002 · N341PH · Dorner DO328100SDR SWAA022012Stud · looseAFTER DEPARTURE AN ELECTRICAL FUME WAS NOTICED, CABIN CREW CONFIRMED FUME. NO CB'S TRIPPED, AC AND DC LOADS ALL NORMAL. FUMES DIMMISHED BUT NOT ELIMINATED. FOUND BLUE FLUID FROM FWD LAV LEAKING AT PRESS FILL. FOUND LOWER ENTRY LIGHT SHORTED OUT DUE TO LAV Aug 31, 2002 · N673AA · Boeing 7373A4SDR 2002UALA01288Valve · failedMID CABIN LAV TOILET OVERFLOWED, WATER SHUTOFF. RINSE VALVE ON TOILET ASSY FAILED IN THE OPEN POSITION. REPLACED TOILET ASSEMBLY.Aug 8, 2002 · N620UA · Boeing 767222SDR SWAA021394Toilet · cloggedDIVERSION, BOTH LAV'S (FWD AND AFT) WOULD NOT FLUSH. UNCLOGGED AFT LAV AND REMOVED AND REPLACED FWD LAV PER MM.Jun 22, 2002 · N705SW · Boeing 7377H4SDR AUS20020366Clamp · missing(AUS) FORWARD GALLEY SINK DRAIN HOSE FOUND NOT CONNECTED TO FLOOR HOSE DUE TO A MISSING CLAMP, CAUSING LEAKAGE THROUGHOUT GALLEY AREA. PERSONNEL/MAINTENANCE ERROR.Apr 4, 2002 · Boeing 737800*SDR SIMA200209422Venturi · corrodedSAW - DURING CPCP2 INSPECTION, FOUND LAVATORY VENTURI TUBE CORRODED. REPLACED LAVATORY VENTURI TUBE IAW SRM 51-25-02. (M)Mar 27, 2002 · N319AM · Aerosp ATR42300SDR DLM11020291Flush Motor · faultyLAV SMOKE WARNING ILLUMINATED. FLT ATTN FOUND NO SMOKE BUT ODOR L4 LAV. FOUND L4 TOILET VALVE MOTOR SMOKING. REPLACED TOILET ASSY.Mar 9, 2002 · N804DE · Doug MD11SDR 2001UALA02503Valve · failedAFT MID LAV CONTINUOUSLY FLUSHING. LAV WATER OVERFLOWED AND FLOODED AREA INCLUDING MID GALLEY. AIRCRAFT DIVERTED TO ORD FOR REPAIR. TOILET RINSE VALVE FAILED IN THE OPEN POSITION. REMOVED AND REPLACED TOILET ASSY.Dec 31, 2001 · N608UA · Boeing 767222SDR SIMA200123401Pan · corrodedSBP - DURING MBV INSPECTION, MAINTENANCE FOUND THE LAVATORY SERVICE BOX IS CORRODED. REMOVED AND REPLACED LAVATORY SERVICE BOX IAW SAAB SERVICE BULLETIN 340-53-050. (M)Aug 14, 2001 · N343SB · Saab 340BSDR GTIA011009Pump · failedFTW - RIGHT AFT LAVATORY SMOKE DETECTOR SOUNDS WHEN ENGINE POWER IS APPLIED. NOTED STRONG SMELL OF EXHAUST FUMES AND LAV WILL NOT FLUSH. REPLACED PUMP ON RIGHT AFT LAV IAW MD80 MM 38-30-00. (M)Jul 8, 2001 · N803NK · Doug DC982SDR DL76L010859Lavatory · inoperativeDIVERTED TO CCS DUE TO LAV SYSTEMS INOP. SERVICED LAVS.May 28, 2001 · N176DN · Boeing 767332SDR GTIA010987Drain Mast · corrodedFTW - E/E BAY, STATION 200 LONGERON 29R, WASTE WATER DRAIN HAS CORROSION. REMOVED CORROSION. VERIFIED OUTER OF LIMITS. FABRICATED NEW DOUBLER. INSTALLED DOUBLER IAW MD-80 SRM 51-30-02. (M)May 21, 2001 · N803NK · Doug DC982SDR DLM11010658Tank · collapsedALL LAVS INOP. CREW HEARD LOUD BANG IN AFT CARGO COMP. 1 1/2 HOURS FROM ARRIVAL IN LAX. FOUND TANK COLLAPSED, AND CRACKED WILL REQUIRE REQUIRE REPLACEMENT P/N 380001285 NASI LAX. WILL ALSO NEED APPROXIMATELY 25 FT OF BELLY BLANKTS REPLACED FWD OF AFT LAV TANK.Apr 22, 2001 · N809DE · Doug MD11SDR QXEA0100307Pan · corrodedYYC-CORROSION ON BOTTOM OF LAV DRAIN TUB INSIDE AFT CARGO PIT. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9 AND SRM 53-01-01, PAGE 6, AND SRM 51-10-04, PAGE 7.Mar 2, 2001 · N497US · Fokker F28MK4000SDR AWXA0001452Line · cloggedLAS - AIR TURNBACK - 2/22/01 - ALL LAVS WOULD NOT FLUSH (CIDS PANEL RED LIGHT WAS ON, WASTE AT 0 PERCENT FULL, WATER AT 40 PERCENT FULL); AIRCRAFT DESTINATION WAS JFK SO THE FLIGHT RETURNED TO LAS. THE LAV SYSTEM HAD PREVIOUSLY BEEN PLACED ON MEL 38-30-01 FORMar 1, 2001 · N640AW · Airbus A320231SDR DL76L010069Module · failedAFTER T/O FIRST CLASS AND RT AFT LAV INOP. AFT WASTE SHUT DOWN. REPLACED AFT WASTE TANK LOGIC CTL MODULE, OPS NORMAL. ALSO FOUND AFT RT-R2- LAV VLV STUCK OPEN. ABLE TO CLOSE SAME MANUALLY, CONNECTED FLUSH SWITCH AND INOPED LAV. NEEDS NEW TOILET. FWD MCO Jan 14, 2001 · N193DN · Boeing 767332
Back to JASC 3830