SDR CALA2019010600023Not Reported · leakingBLUE WATER ON FWD CARGO STRUCTURE AND FEW SECTIONS OF INSULATION FROM STA 560 TO STA 900 LT SIDE FROM STR 22L TO 28R. CLEANED BLUE WATER ON FWD CARGO STRUCTURE FROM STA 560 TO STA 900 LT SIDE FROM STR 22L TO 28R IAW EC/RA 2011-01000. INSULATION BLANKET HAS BEESDR DALA2019011600304Line · cloggedSHIP 3841 - DIV - DIVERTED TO SLC DUE TO ALL LAVS INOP. TANKS SHOW FULL. CORRECTIVE ACTION: FOUND DUMP LINE CLOGGED UPSTREAM FROM DUMP VALVE. CLEARED BLOCKAGE (DIAPER). DRAINED AND FLUSHED TANK. ALL LAVS OPERATE NORMALLY. OK FOR SERVICE. (5006480).SDR F3LA2018122100482Valve · faultyDISCREPANCY: LP11766619-1 DURING #1 ENGINE START WITH APU BLEED AIR AN UNKNOWN ODOR ENTERED THE AIRCRAFT AND WAS
IMMEDIATELY REPORTED BY THE FA'S. QRH PROCEDURES C/W, BTB.
CORRECTIVE ACTION: AIRCRAFT WAS GROUNDED DUE TO EVENT, AND THEN A MAINTENANCE FERRY SDR AALA2018121189001Hose · severedDIRTY SOCK ODOR REPORTED BY F/AS IN THE AFT CABIN. ODOR NOT NOTICEABLE IN THE COCKPIT. THE AIRCRAFT WAS GROUNDED. MAINTENANCE ACCOMPLISHED SMOKE ODOR FUMES MCM CARD 05-96-70 AND FOUND SEVERED GRAY WATERLINE LEAKING ONTO RECIRCULATION FILTER. REMOVED AND REPSDR DALA2018112746860Sink · cloggedSHIP 6810 -DIV- DIVERTED INTO SLC DUE TO AFT LAV SINKS OVERFLOWING. WATER HAS BEEN SHUT OFF TO THE AFT SINKS. CORRECTIVE ACTION: FOUND BOTH SINKS CLOGGED, UNCLOGGED AFT RIGHT DRAIN. MEL'D AFT LEFT DRAIN. AFT LEFT DRAIN CLEARED IN SFO.SDR AALA201810309001Float Valve · cloggedSTRONG VOMIT ODOR NEAR THE L1 DOOR. NO VOMIT PRESENT. MAINTENANCE FOUND FWD SILL DRAIN FLOAT VALVE CLOGGED. REMOVED AND REPLACED IAW AMM 38-31-06. OPS CHECKED NORMAL.SDR AALA2018102659015Float Valve · cloggedDURING CRUISE FLIGHT, AT 2 HOURS AND 30 MIN, THE FLIGHT ATTENDANT REPORTED A ROTTEN ODOR COMING FROM THE VENTS IN THE FORWARD 1ST CLASS, NEAR LAVATORY. THE AIRCRAFT WAS GROUNDED. FOUND A CLOGGED DRAIN FLOAT VALVE. REPLACED THE FLOAT VALVE IAW AMM 38-31-06SDR ANCF2018F00138Toilet · inoperativeTHREE TOILETS ARE INOPERATIVE.SDR AALA2018101219011Drain Line · cloggedDURING CLIMBOUT OUT OF 10,000 FT. FLIGHT ATTENDANTS REPORTED A VERY STRONG DIRTY SOCK, RANCID CHEESE ODOR IN THE FORWARD CABIN. THE FLIGHT DECK CREW DONNED OXYGEN MASKS AND DECLARED AN EMERGENCY. ODOR STARTED TO DISSIPATE SLOWLY AT LEVEL OFF AT 14,000 FT ANSDR SIMA2018100128002Unknown · odorNOXIOUS FUMES EMANATING FROM FWD LAV. SERVICING AND CLEANING ONLY MASK THE FUMES / SMELL AND THEY RETURN PROMPTLY AFTER SERVICING AND CLEAN8ING OF THE FWD LAV. FUMES ARE NOTICABLE IN THE CABIN BACK TO ROW 3-C/A-DEFERRED FWD LAV M PROCEDURES
C/W MEL 38-11 AUTSDR SIMA2018100128005Unknown · odorWHEN AFT LAV IS FLUSHED NOXIOUS FUMES AND SMELLS ARE PUSHED INTO THE CABIN SMELL AND FUMES SLOWLY DISSIPATE SEVERAL MINUTES AFTER FLUSHING THE AFT LAV-C/A-PERFORMED TROUBLESHOOT ON AFT LAV FLUSH SYSTEM IAW FIM 25-40-00. NO DEFECT FOUND. PERFORMED FLUSH VACUUM SDR CALA2018100102005Not Reported · leaking(B757-53-3-0547) LT FLIGHT DECK FLOOR STRUCTURE AREA COVERED BY LT FLIGHT DECK PANELS FROM APPROX. STA 310 TO 200, TO INCLUDE LT CREASE BEAM AND STA 310 BULKHEAD OF FLIGHT DECK FLOOR , DIRTY WITH BLUE WATER STAIN CLEANED, NEUTRALIZED, PERFORMED DVI OF, AND APPSDR AALA201809259018Toilet · leakingPHL FLT 717 EN-ROUTE MUC - PHL. THE AIRCRAFT WAS GROUNDED. CREW REPORTS URINE ODOR THROUGHOUT THE ENTIRE CABIN FROM PUSHBACK TO TAXI IN. MAINTENANCE ACCOMPLISHED J/C 33L00021001 AND J/C 33L13038001. R&R L74 TOILET ASSY AND CLEANED THOROUGHLY UNDER TOILET. SDR AALA201809049064Toilet · leakingLAVATORY L61 & L62 HAVE A STRONG ODOR. CLEANED LAV L61. THE AIRCRAFT WAS GROUNDED. MAINTENACE REMOVED AND REPLACED LEAKING TOILET ASSY LAV L61 IAW AMM 38-31-41-0401.SDR AALA201808229050Transmitter · defectiveLEFT LAVATORY TANK LEVEL WENT TO 100% AFTER TAKEOFF. LEFT SIDE SYSTEM SHUTDOWN FLUID IN BOWLS SPILLED OUT. AN EMERGENCY WAS DECLARED AND RETURNED TO FIELD. THE AIRCRAFT WAS GROUNDED. MAINTENANCE REPLACED LEFT WASTE LEVEL TRANSMITTER IAW AMM 33-31-11-400-801ASDR AALA2018082209039Toilet · defectiveLEFT LAVATORY TANK LEVEL WENT TO 100% ON AFTER TAKEOFF, LEFT SIDE SYSTEM SHUTDOWN, FLUID IN BOWLS SPILLED OUT. DECLARED AN EMERGENCY, AND RETURNED TO FIELD. THE AIRCRAFT WAS GROUNDED. MAINTENANCE REPLACED LEFT WASTE LEVEL TRANSMITTER IAW AMM 33-31-11-400-80SDR CALA2018082001832Drain · cloggedROWS 7 - 27, BOTH AISLES AND CENTER CARPET SOAKED WITH WATER FROM OVERFLOWING FAUCET IN LAV J. CHECKED FAUCET NO FAULTS NOTED, FOUND OVERFLOW DRAIN IN SINK PLUGGED UP. CLEARED BLOCKAGE AND VERIFIED WATERFLOW OUT OF DRAIN MAST. INSPECTED AND FOUND WATER DRIPPINSDR AALA201808019014Sensor · faultyONLY THREE LAVATORIES HAD NORMAL OPERATIONAL FLUSH 2F-1R, 2F-1L, AND 4F-R. TWO WERE COMPLETELY UNUSABLE AND NO FLUSH: 1A-L AND 3F-1L THREE WERE VERY WEAK NEARLY USABLE 3F-2R, 3F-1R, 4F-L. AIRCRAFT ABOVE 16000. THE FLIGHT DECLARED AN EMERGENCY AND DIVERTED TO SDR AALA2018072769003Blanking Plate · missingONLY THREE LAVATORIES HAD NORMAL OPERATIONAL FLUSH 2F-1R, 2F-1L, AND 4F-R. TWO WERE COMPLETELY UNUSABLE AND NO FLUSH: 1A-L AND 3F-1L THREE WERE VERY WEAK NEARLY USABLE 3F-2R, 3F-1R, 4F-L. AIRCRAFT ABOVE 16000. THE FLIGHT DECLARED AN EMERGENCY AND DIVERTED WITSDR ASAA2018072325485Circuit Breaker · trippedAFTER LEVEL OFF FA REPORTS ALL LAVS WILL NOT FLUSH. GROUNDED - YES. DIVERSION TIME 63 MINUTES - FOUND VAC WASTE CNTRL C/B ON P91 PNL OPEN, RESET C/B AS PER AMM 20-60-01. ACCOMPLISHED OPS CHK OF ALL LAVS OPS CHK GOOD OK FOR SERVICE REF FIM 38-30 TASK 811.SDR AALA2018041809041Relay · faultyAFT LAVATORY WONT FLUSH, ELECTRICAL SMELL IN AFT LAV/GALLEY AREA MX SAYS VACUUM PUMP IS NOT FUNCTIONING CORRECTLY. REPLACED MOTOR START RELAY IAW AMM 38-31-36.SDR AALA2018041809040Pump · faultyAFT TOILET WON`T FLUSH, ELECTRICAL ODOR IN THE AFT LAVATORY. MX FOUND THE VACUUM PUMP IS NOT FUNCTIONING CORRECTLY. REPLACED VACUUM GENERATOR IAW AMM 38-31-64.SDR CALA2018041801184Lavatory · malfunctionedLAVATORIES E, G, AN J TOILETS BACKING UP AND NOT FLUSHING AFTER SERVICING OPS CHECKED OK.SDR CALA2018022800828Toilet · malfunctionedCABIN CREW REPORTED THAT RT FWD LAVATORY INSIDE HAD A PLASTIC ODOR, NOTICED ON UPPER LEFT SIDE. CREW CHECKED TRASH COMPARTM ENT, NO ISSUES NOTICED. FOUND FLUSH CONTROL UNIT ON TOILET ASSY CAUSING ODOR WHENEVER TOILET WAS FLUSHED. REPLACED THE TOILET ASSY ISDR AALA201802149002Bladder · odorAIRCRAFT HAD VERY STRONG ACRID,OFFENSIVE ODOR COMING FROM FORWARD GALLEY AND FORWARD ENTRY AREA. ONE HOUR INTO FLIGHT THE THE WAS STILL PERVASIVE. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED SIC 05-96-70. FOUND FORWARD SILL DRAIN BLADDER THE CAUSE OF ODOR. RSDR SWAA2018012419293Control Module · faultyLAVATORYIES STOPPED WORKING IN FLIGHT. R & R THE LOGIC CONTROL MODULE IAW AMM.SDR AALA20180121009Drain Line · brokenAIRCRAFT WAS GROUNDED: FOUL SMELL REPORTED IN CABIN. MAINTENANCE FOUND WASTE DRAIN LINE ABOVE RECIRCULATION FILTER LEFT HAND BROKEN, WHICH WAS LEAKING ONTO RECIRCULATION FILTER. MAINTENANCE REPLACED WASTE DRAIN LINE ABOVE LEFT HAND RECIRCULATION FILTER PER AMSDR CALA2017122004547Generator · odorFLIGHT ATTENDANTS REPORT SCORCHED PLASTIC SMELL COMING FROM AFT GALLEY OR LAVS. REPLACED WASTE VACUUM GENERATOR PER AMM 38-31-64. OPS CHECKS GOOD, NO BURNING SMELL NOTED.SDR SIMA20171112001Sensor · dirtyINFLIGHT BOTH LAVS OVERFLOWING. CLEANED TOP WASTE TANK LEVEL SENSOR IAW AMM 38-32-20. OPS CHECK GOOD.SDR DALA2017110107897Drain Mast · corrodedAFT FUSELAGE DRAIN MAST REMOVED ON WORK CARD 5683351 HAS CORROSION ON UPPER MOUNTING SURFACE AT CORRODED SCREW. REMOVED AND REPLACED DRAIN MAST FOR AFT FUSELAGE AND PERFORMED OPS CHECK IAW AMM 38-31-01.SDR DALA2017072405670Blower · failedAT GATE PRIOR TO PUSH BACK, A STRONG ELECTRICAL ODOR EMANATED FROM THE AFT LAVATORY AREA IN THE CABIN. MAINTENANCE FOUND THE LAVATORY BLOWER MOTOR CIRCUIT BREAKER HAD TRIPPED OPEN. MAINTENANCE REPLACED THE LAVATORY WASTE VENT SYSTEM BLOWER.SDR AALA20170603003Waste Tank · blockedEMERGENCY DECLARED. FLIGHT DIVERTED DUE TO 4 OF 6 LAVATORIES READING FULL. LANDING UNEVENTFUL. ACCOMPLISHED LAVATORY LEVEL SENSOR AND CONTROLLER RESET IAW AMM 38-33-00. ISSUE REPEATED ON LAVATORIES FS3, M2, AND A5 FIVE HOURS INTO CONTINUED FLIGHT. REMOVSDR DALA2017053104522Check Valve · corrodedFWD AND AFT VAC WASTE TANK CHECK VALVES HAVE CORROSION ON INNER SURFACE. REMOVED AND REPLACED FWD AND AFT VACUUM WASTE TANK CHECK VALVE ASSY'S PER MM 38-32-36. NO DEFECTS NOTED.SDR AALA20170407007Not Reported · inoperativeDFW-NRT DIVERTED TO ANC ACCOUNT 5 OF THE LAVATORIES WERE INOPERATIVE. AN EMERGENCY WAS DECLARED AND THE FLIGHT LANDED OVERWEIGHT WITHOUT INCIDENT. MAINTENANCE SERVICED LAVATORIES. THE AIRCRAFT WAS NOT GROUNDED.SDR AALA201703109009Connector · looseAFT LAVATORY FLUID INJESTED IN THE APU DUE TO WASTE PLUMBING LINE LEAKING. TIGHTENED WASTE SYSTEM 3 WAY CONNECTOR IAW AMM 20-10-11. SERVICED AND DRAINED AFT LAVATORIES AND ACCOMPLISHED APU WASH. LEAK AND OPERATIONAL CHECK GOOD. AIRCRAFT WAS GROUNDED.SDR AALA20170215022Drain Valve · faultyAIRCRAFT WAS GROUNDED. AFTER TAKEOFF, STRONG ODOR IN COCKPIT AND IN CABIN, DISSIPATED AFTER 10 MINUTES. REMOVED AND REPLACED FORWARD GRAY WATER DRAIN VALVE IAW AMM 38-31-02. OPERATIONAL CHECK GOOD.SDR UIEA2017020800162Mast · corrodedCORROSION ON FUSELAGE LT LOWER SIDE MAST AND COVER POTABLE WATER SYSTEM. REPLACED THE DRAIN MAST IAW AMM 38-31-61-004-002 REV 88 AND AMM 38-31-61-404-013 REV 88. PERFORMED A TEST OF DRAIN MAST IAW AMM 38-31-61-404-013 REV 88.SDR HALA2016111900517Water Heater · leaking4L LAV LEAKING, UNABLE TO STOP WITH SHUTOFF VALVE. 4L LAV WATER LINE BENEATH WATER HEATER HAD UNCONTROLLABLE WATER LEAK. CLOSED LAV SUPPLY S/O VALVE AND LAV BLOCKED PER MEL 38-30-1B CAT C. INSPECTED AFT CARGO AREA, NO WATER FOUND. R&R WATER HEATER AT 4L LAV PSDR AALA201611079013Generator · damagedAIRCRAFT WAS NOT GROUNDED. VACUUM GENERATOR EMITS ELECTRICAL SMELL AND SOUNDS DAMAGED. REPLACED VACUUM GENERATOR PER AMM 38-31-64.SDR AALA20161016002Restrictor Valve · failedAIRCRAFT WAS GROUNDED. LHR, AIR INTERRUPT, FCO-ORD. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT OVERWEIGHT. DURING CRUISE THE 4L AND 4R LAVATORY SINKS FILLED THEN OVERFLOWED WITH WASTE WATER. REMOVED AND REPLACED DRAIN MAST GRAY WATER RESTRICTOR VALSDR AALA20161011013Valve · bindingDURING CRUISE MULTIPLE LAVATORIES REPORTED INOPERATIVE. EMERGENCY DECLARED. LANDING UNEVENTFUL. MAINTENANCE VERIFIED ALL WASTE TANKS WERE EMPTIED. MOST AFT LEFT DRAIN VALVE FOUND HARD TO OPERATE. EXECISED VALVE LEVER. ALL LAVATORIES FUNCTION NORMAL IAW AMM SDR R61A201609240595Service Panel · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, MAINTENANCE REPORTED LEVEL 2 CORROSION ON THE WASTE SERVICE PANEL AND INTERNAL DOUBLER. MAINTENANCE PERFORMED MAJOR REPAIR. REMOVED AND REPLACED THE WASTE SERVICE PANEL (P/N 170-86668-403) DOUBLER (P/N 170-86655-003) ANSDR HALA2016081700150Unknown · malfunctionedAIRCRAFT DIVERTED DUE TO THE LT SIDE LAVS WOULD NOT FLUSH AND THE RT LAVS HAD NO WATER. SERVICED WATER SYSTEM AND LOCKED OUT LT LAVS AND DEFERRED IAW MEL 38-30-1B-HNL. RESET LAV SYSTEM, OPS CHECK OK.SDR SIMA20160725005Valve · corrodedTOILET WASTE VALVE SUPPORT BUCKET IS CORRODED. REMOVED AND REPLACED TOILET WASTE VALVE SUPPORT BUCKET IAW SRM 51-40-02SDR AALA20160720001Lavatory · underservicedDURING CLIMB FLIGHT ATTDENDANTS REPORTED ALL LAVATORIES INOPERATIVE. EMERGENCY DECLARED. LANDING UNEVENTFUL. LAVATORIES SERVICED. SYSTEM CHECKED NORMAL.SDR ASMF201608002Coupler · leakingDURING TRANSIT CHECK, A WATER LEAK WAS DETECTED IN THE LOWER FUSELAGE. MAINTENANCE PERSONNEL PERFORMED REVISION DETECTING WATER LEAK IN THE LT AFT CARGO COMPARTMENT LINE AND COVER AND IN AFT DRAIN VALVE LINE. THE COVER, COUPLER AND DRAIN VALVE LINE SEALS WERSDR AALA20160616009Drain Valve · defectiveACFT WAS GROUNDED. AFTER TAKEOFF THERE WAS A STRONG SMELL OF VOMIT COMING FROM THE COCKPIT AIR DUCTS AND IN THE FORWARD GALLEY AREA. FOUND FWD AND AFT DOOR SILL DRAINS CLOGGED. MAINTENANCE FOUND THE FORWARD SILL DRAIN VALVE BAD. R & R VALVE IAW AMM 38-31-0SDR SWIA201642190Lavatory · leakingSTRINGER 27, BS 954 - 969 CORRODED DUE TO AFT LAV WASTE WATER LEAK. COMPLETED REPAIR IAW RE. PRESSURE CHECKED GOOD.SDR R61A201605060353Clamp · corrodedDURING HEAVY CHECK, FOUND LWR CLAMP ON WASTE DRAIN LINE CORRODED. EAMS MAINTENANCE REMOVED OLD CLAMP AND ATTACHED NEW TO AFT WASTE PIPE FOR LATER INSTALL IAW AMM 38-32-15, REF TASK 1552 EO-170, EO-53-10-0020, STEP 5 FOR INSTALLATION OF WASTE TUBE. CLAMP PN 1SDR R61A2016050600345Clamp · corrodedWHILE ACFT WAS IN FOR HEAVY CHECK, FOUND LOWER CLAMP ON WASTE DRAIN LINE IS CORRODED. EAMS MAINTENANCE R & R LOWER CLAMP ON WASTE DRAIN LINE PN 19000-086,