What it covers
For reports indicating a problem with wiring specific to the Water/Waste System.
Service difficulty reports · 63
Reports filed under 3897, newest first.
| 1998 | 1 |
|---|---|
| 2002 | 3 |
| 2003 | 1 |
| 2004 | 4 |
| 2005 | 2 |
| 2006 | 4 |
| 2007 | 2 |
| 2008 | 2 |
| 2009 | 4 |
| 2010 | 4 |
| 2011 | 6 |
| 2012 | 5 |
| 2013 | 3 |
| 2014 | 4 |
| 2016 | 1 |
| 2017 | 2 |
| 2018 | 2 |
| 2019 | 3 |
| 2020 | 1 |
| 2022 | 1 |
| 2023 | 2 |
| 2024 | 2 |
| 2025 | 1 |
| 2026 | 3 |
SDR CALA2026100620165Logic Card · faultedAFT LAV WASTE INDICATES ZERO AFTER FLT, SEWAGE ODOR INFLIGHT, LAV INDICATORS ERONIOUS. ACCOMPLISHED INSPECTION OF WASTE WATER TANK, NO ACTIVE LEAKS NOTED, SERVICED WASTE SYSTEM WITH NO DEFECTS. NO SEWAGE NOTED. REMOVED AND REPLACED THE WASTE TANK LOGIC ASSDR YENA2026061500478Elec Connector · faultedFLT # 2930 MCO-DCA (AIRTURN BACK TO MCO). NO LAVS WOULD FLUSH AFTER AIRBORNE AND REACHING FL370. MULTIPLE WASTE AND WATER ERRORS NOW SHOWING ON CMS PANEL; AIRCRAFT ARRIVED WITH NUMEROUS CAN NETWORK MESSAGES OF TOILET SYSTEM. T/S FOUND CAN LOW PIN AT PLUG A431 SDR YENA2026030600273Interface Unit · odorFLT # 1131 CHS-FLL." RETURNED TO GATE FOR BURNING RUBBER SMELL IN AFT LAV C ( LAVATORY WASTE SYSTEM CENTER AFT LAV (LAV C) ).;FOUND MANUAL THERMOSTAT CONTROL AT MAX SETTING ADJUSTED PER AMP J38-12-34-01-01-AAA-720-A NO ODOR NOTED OPS CK GOOD THIS CLEARS MDDR#