JASC 5100
Service difficulty reports · 4,244
Reports filed under 5100 · Standard Practices/Structures, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5100' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5100' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA200120005Track · corrodedSBP - AIRSTAIRS TRACK CORRODED. REMOVED AND REPLACED CORRODED TRACK IAW SRM. (M)SDR SIMA200120004Angle · corrodedSBP - LEFT ANGLE AT STATION 258 IS CORRODED. REMOVED AND REPLACED ANGLE IAW SAAB SRM 51-40-21. (M)SDR SIMA200120002Angle · corrodedSBP - LEFT ANGLE THAT ATTACHES TO THE RIGHT INTERCOSTAL IS CORRODED FROM STATION 236.5 TO STATION 258. REMOVED AND REPLACED LEFT ANGLE IAW SAAB SRM 51-20-21, 51-20-41 AND 51-20-50. (M)SDR SIMA200120001Intercostal · corrodedSBP - RIGHT INTERCOSTAL CORRODED FROM STATION 236.5 TO STATION 258.0. REMOVED AND REPLACED INTERCOSTAL IAW SAAB SRM 51-20-21, 51-20-41 AND 51-20-50. (M)SDR AALA20011480Track · corrodedTUL - FOUND CORROSION BEYOND MM LIMITS SEAT TRACK NR 1 STATION 1174-1307. INSTALLED NEW SECTION OF TRACK PER SRM 51-10.SDR C2XA01BT136Doubler · corrodedYUL---CO4370, DURING 3C CHECK IN YUL MAINTENANCE FOUND AT FRAME 39 RIGHTHAND SIDE STATION 14 DOUBLER CORRODED....REMOVED AND REPLACED DOUBLER IAW ATR42 SRM 51-25-01 AND ATR42 SRM 51-25-04.SDR AALA20011354Stiffener · crackedTUL - FOUND CRACK IN VERTICAL STIFFENER 4 INCHES FROM BOTTOM RIGHT WHEEL WELL AT APU DISCHARGE CUT OUT. REMOVED AND REPLACED VERTICAL STIFFENER PER DRAWING 65-18636 AND ESO 11697 6/28/2001. (M)SDR AALA20011399Web · crackedTUL - FOUND RIGHT NOSE GEAR PRESSURE DECK HAS VISUAL INDICATION OF CRACK AT RIVET ABOVE PANEL AT STATION 203. INSTALLED DOUBLER PER SRM 51-40-2 USING .063 2024 T-3 WITH .1875 INCH MS20470D RIVETS AND SIX .1875 INCH HI-LOCKS. (M)SDR AALA20011312Beam · corrodedTUL - FOUND STATION 265 LBL CORROSION ON FLOORBEAM. INSTALLED REPAIR PER ESO 11697 DATED 6/25/2001. (M)SDR AALA20011379Stiffener · dentedTUL - FOUND VERY DEEP DENTS IN FUSELAGE FRAME ON AFT SIDE STATION 1287 BELOW LONGERON 17L. REMOVED OLD STIFFENER/SHEAR TIE. INSTALLED DUPLICATED PART OF 2024-T0, HEAT TREATED TO T-3, .050 THICK DUPLICATED (DUPLICATED ON SHOP ORDER 2202530 DATED 6/21/01). INSDR AALA20011302Stiffener · corrodedTUL - FOUND VERTICAL STIFFENER CORRODED OUTBOARD OF NR 2 LEADING EDGE FLAP ACTUATOR AT NR 2 TANK PRESSURE SWITCHES AT WFS 244. REPLACED STIFFENER PER SRM 51-10-1. (M)SDR AALA20011300Stringer · corrodedTUL - FOUND STRINGER 28R IS CORRODED ON OUTBOARD SIDE. REMOVED CORRODED STRINGER AT STATION 950C PLUS 9,5 INCH AND 950 PLUS 8 INCHES. INSTALLED STRINGER FILLERS SPLICE ANGLES PER ESO 11697 DATED 6-22-2001. (M)SDR AALA20011387Stiffener · crackedTUL - FOUND FS 1338 PRESSURE BULKHEAD FORWARD FACE UPPER 12 O'CLOCK STIFFENER IS CRACKED .75 INCH AT UPPER MOST END OF ATTACHMENT. REMOVED AND REPLACED VERTICAL STIFFENER ABOVE VAULT DOOR PER MM 51-01. (M)SDR AALA20011313Stiffener · corrodedTUL - FOUND VERTICAL STIFFENER CORRODED. REMOVED AND REPLACED STIFFENER 51-10-00. (M)SDR RRXA11314Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT BATH TUB FITTING AT STA.310 AND L32R-L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8SDR AALA20011304WebTUL - FOUND RIGHT LOWER TORQUE BOX VERTICAL WEB ROUTED OUT AT LIGHTENING HOLE WITHOUT REPAIR. INSTALLED DOUBLER REPAIR ON WEB PER SRM 51-40-2 FIG 1, PAGE 1. (M)SDR RRXA11306Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATH TUB FITTING AT STA.315-340 AND L32R-L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SSDR RRXA11304Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO BATH TUB FITTING AT STA.313 AND L33R-L32R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-SDR QXEA0101084Structure · corrodedPDX - CORROSION AROUND NUT PLATE, UNDER RIGHT-HAND 144HZ, INBOARD AFT CORNER. REPAIRED IAW DHC-8 1-GEN-5, CHAPTER 4, SRM 51-20-11 AND MM 20-32-02.SDR RRXA11299Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO R/H SIDE OF VERT. STAB LWR SKATE ANGLE AT STA.1750-1790, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED SDR RRXA11272Fitting · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO B-PIT SPLICE FITTING AT STA.440-460 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 5SDR RRXA11271Intercostal · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO B-PIT INTERCOSTAL AT STA.440 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20DSDR RRXA11268Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT FRAME BANNANA FITTING AT STA.340 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-SDR AALA20011269Spar · corrodedTUL - FOUND CORROSION ON FRONT SPAR AT NR 2 SLAT ACTUATOR CUT OUT LOWER SIDE. FABRICATED STRAP .040-17-7 PH STAINLESS STEEL. INSTALLED 6 EACH FASTENERS EITHER SIDE OF BLEND AREA WET. INSTALLED PER ESO 11697 DATED 6/07/2001. (M)SDR RRXA11241Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO B-PIT FRAME AT STA.400 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 53SDR RRXA11235Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT CROSS SLIDE TORQUE BOX BATHTUB FITTING AT STA.320 AND L33R-L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART SDR RRXA11233Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT FWD TORQUE BOX BATHTUB FITTING AT STA.270 AND L32R-L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTSDR AALA20011240Beam · corrodedTUL - FOUND CORROSION UNDER DOOR STOPS AT AFT CARGO DOOR LOWER CUTOUT. COMPLETED DOOR JAMB REPAIR PER AARD 53-10-00-3 AND SRM 51-10-3. (M)SDR AALA20011147Splice · crackedTUL - FOUND STRINGER SPLICE CRACKED. REMOVED AND REPLACED STRINGER SPLICE. (M)SDR AALA2001148Web · corrodedTUL - FOUND LEFT HORIZONTAL WALKWAY CORRODED 9 INCHES BY 3 INCHES UNDERSIDE BETWEEN STATION 303 TO 312. REMOVED CORRODED AREA OF WALKWAY. INSTALLED DOUBLER PER SRM. (M)SDR AALA20011149Strap · corrodedTUL - FOUND CORROSION 4 INCHES BY 12 INCHES, ON BUTT SPLICE STRAP AT STATION 680, BETWEEN 28L AND 28R. REMOVED CORRODED STRAP AND INSTALLED NEW STRAP. (M)SDR AALA20011154Stringer · corrodedTUL - FOUND STRINGER CORRODED AND SPLIT AT THE DRAIN MAST. INSTALLED STRINGER REPAIR AS PER SRM 53-10-3. INSTALLED NEW DRAIN MAST PAN PER SRM 51-10-1. (M)SDR AALA20011078Angle · corrodedTUL - FOUND ANGLE AT TOP OF TRAPEZOIDAL PANEL CORRODED AROUND FASTENERS STATION 951-955. REMOVED AND REPLACED ANGLE SRM 51-01. (M)SDR AALA20011068Fitting · corrodedTUL - FOUND CORROSION ON DOOR CUTOUT FORWARD LOWER CORNER FITTING. INSTALLED NEW CORNER FITTING SRM 51-01. (M)SDR AALA20011064Bracket · corrodedTUL - FOUND CORROSION ON DOOR CUTOUT FORWARD LOWER CORNER CURVED BRACKET. INSTALLED NEW BRACKET SRM 51-01. (M)SDR RRXA11114Skin · dentedDURING A MAINTENANCE VISIT FOUND DENT DAMAGE TO SKIN AT STA.1240 BETWEEN L30R-L27R, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-1 FIG#SDR RRXA11042Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RH VERT STAB SKATE ANGLE AT STA 1766-1780 AND L2R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-SDR AALA20001741Service difficultyTUL - FOUND STATION 950E FORWARD SIDE OF FRAME BETWEEN STRINGER 25L-26L SHEAR TIE CORRODED. RENOVED AND REPLACED SHEAR TIE PER SRM 51-10-1. (M)SDR QXEA0000192Seat Track · corrodedPDX - LEFT INBOARD CABIN SEAT TRACK HAS .25 INCH AREA OF CORROSION INSIDE CHANNEL AT 5 FORWARD OF FRAME 8805. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9, PARAGRAPH B 1-2.SDR QXEA0000157unknownPDX - CORROSION ON INBOARD FLANGE OF SEAT TRACK 1147R BETWEEN FRAMES 8305 AND 9305. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9, PARAGRAPH B, 1-2.SDR AALA990805Stringer · corrodedTUL - FOUND CORROSION ON STRINGER 28L AT STATION 720 PLUS 15 INCHES. REMOVED CORROSION INSTALLED REPAIR STRAP PER ESO 11697 DATED 5-27-99. (M)SDR P2EA98286Stiffener · crackedSJO - RIGHT HORIZONTAL STAB, STAB STATION 101.9, NR 4 STIFFENER LOWER CHORD CRACKED. DEFECT SIZE LENGTH 1.75 INCH. REPLACED STAB CHORD AT STAB STATION 101.9, BETWEEN FRONT AND REAR SPAR PER SRM 51-10-1 PAGE 5 AND SRM 51-30-2. (M)SDR QXEA9700849Clip · crackedPDX - CRACK IN CLIP AT FRAME 15205 STRINGER 26. REPAIRED IAW FOKKER SRM 53-02-13 PAGE 4 FIGURE 2.SDR QXEA9700804Angle · crackedPDX - CRACK IN ATTACH ANGLE AT FRAME 5305 3 INBOARD OF STRINGER 17 ON FORWARD SIDE OF FRAME. REMOVED AND REPLACED WEB IAW SRM 51-31-01.
Back to JASC 5100