What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RH VERT STAB SKATE ANGLE AT STA 1766-1780 AND L2R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-5, 51-1-26. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).