SDR AALA2020052989013Damper · defectiveAIRCRAFT IN BASE MAINTENANCE: DURING OPERATIONAL TEST FOR DAMPING FUNCTION AT R2 DOOR, DAMPER AND EMERGENCY OPERATION CYLINDER DOES NOT DECREASE SPEED AT THE END OF DOOR OPENING TRAVEL. REPLACED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 25-13-14.SDR AALA202005299006Bottle · low pressureAIRCRAFT NOT GROUNDED. L2 DOOR ASSIST BOTTLE, LOW PRESS (1500 PSI). SERVICED L2 DOOR ASSIST BOTTLE PER AMM 52-10-00.SDR AALA202005299005Bottle · low pressureAIRCRAFT NOT GROUNDED. R4 DOOR ASSIST BOTTLE, LOW PRESS (1500 PSI). SERVICED R4 DOOR ASSIST BOTTLE PER AMM 52-10-00.SDR AALA202005299004Bottle · low pressureAIRCRAFT NOT GROUNDED. R3 DOOR ASSIST BOTTLE, LOW PRESS (1550 PSI). SERVICED R3 DOOR ASSIST BOTTLE PER AMM 52-22-00.SDR AALA202005299003Bottle · low pressureAIRCRAFT NOT GROUNDED. R1 DOOR ASSIST BOTTLE, LOW PRESS (1500 PSI). SERVICED R1 DOOR ASSIST BOTTLE PER AMM 52-10-00.SDR AALA2020052989002Damper · low pressureAIRCRAFT NOT GROUNDED. LEFT AFT DOOR (832) ASSIST BOTTLE, LOW PRESSURE. REMOVED AND REPLACED DOOR DAMPER/DOOR ASSIST CYLINDER PER AMM TASK 52-10-00-614-001-A.SDR SWAA2020061580609Beam · crackedCRACK INDICATION FOUND AT FWD SERVICE DOOR INTERNAL LWR BEAM #4 UPPER FILLET REGION. / REMOVED AND REPLACED BEAM AT FWD SERVICE DOOR INTERNAL LOWER AS PER B737-7 SRM 51-40-02-0G-0 DRAWING # 141A6535SDR GTIA2020052835187Bottle · low pressureL2 DOOR ASSIST REQUIRES SERVICING. SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECK GOOD.SDR AALA202005279005Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R4 DOOR ASSIST BOTTLE AT 0 PSI. SERVICED R4 DOOR ASSIST BOTTLER IAW AMM 52-10-00.SDR AALA202005279004Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - L3 DOOR ASSIST BOTTLE AT 0 PSI. SERVICED L3 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA202005279003Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE - L3 DOOR FAILED EPAS (EMERGENCY POWER ASSIST SYSTEM) BATTERY PACK TEST. ACCOMPLISHED JOB CARD 8300, PASSENGER ENTRY DOOR EPAS BATTERY OPERATIONAL CHECK, CHECK PASSED.SDR AALA202005279002Battery Pack · dischargedAIRCRAFT IN BASE MAINTENANCE - R3 DOOR FAILED EPAS (EMERGENCY POWER ASSIST SYSTEM) BATTERY PACK TEST. ACCOMPLISHED JOB CARD 8300, PASSENGER ENTRY DOOR EPAS BATTERY OPERATIONAL CHECK, CHECK PASSED.SDR AALA2020052969003Damper · failedAIRCRAFT IN BASE MAINTENANCE. L2 AFT PASSENGER CREW DOOR (832), DAMPER AND EMERGENCY OPERATION CYLINDER FAILED OPERATIONAL TEST. REPLACED DOOR DAMPER ASSEMBLY PER AMM TASK 52-13-14-400-001-B.SDR AALA2020052969002Damper · failedAIRCRAFT IN BASE MAINTENANCE. L1 FORWARD PASSENGER CREW DOOR (831), DAMPER AND EMERGENCY OPERATION CYLINDER FAILED OPERATIONAL TEST. REPLACED DOOR DAMPER ASSEMBLY PER AMM TASK 52-11-14-400-001-B, AND JOB CARD 26C83152007.SDR SWIA2020062351147Intercostal · corrodedPASSENGER DOOR INTERCOSTAL DD7A HAS CORROSION ON WEB SURFACE. (C-CHECK) RO 6/21/2020 REMOVED CORRODED PAX DOOR DD7A INTERCOSTAL AND REPLACED WITH NEW REFERENCING DWG, SRM. LEAK TEST GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. COMPLETED FORM M-33SDR SWIA2020062351168Fitting · corrodedFWD AND AFT PAX DOOR ENTRANCE FLOOR CLOSING FITTINGS ARE CORRODED AROUND THE FASTENER HOLES. (C-CHECK) RO 6/21/2020 AFTER REMOVAL OF CORROSION, FWD PAX DOOR CLOSING FITTING FOUND OUT OF LIMITS, AFT PAX DOOR CLOSING FITTING FOUND WITHIN LIMITS. REMOVED AND RESDR SWIA2020062351132Angle · corroded*PAX DOOR SURROUND LWR INBD SILL ANGLE IS CORRODED (MARKED) (C-CHECK) RO 6/21/2020 BLENDED PAX DOOR SURROUND LOWER INBD SILL ANGLE REF CRJ700 SRM. OUT OF LIMITS REF CRJ700 SRM. REPLACED PAX DOOR SURROUND LOWER SILL ANGLE (KICK PLATE ANGLE) REF BOMBARDIER SDR GTIA2020052135184Bottle · low pressureR1 DOOR DOOR REQUIRES SERVICING-SERVICED R1 DOOR ASSIST TO PROPER LEVEL IAW AMM 51-10-00SDR VNAA2020052099910Intercostal · corrodedPAX DOOR INTERCOSTAL DD4 CORRODED, PN:601R318081-1. LOCATED,DRILLED,NEW SERVICEABLE PAX DOOR INTERCOSTAL DD4 PN:601R318081-1 IAW CRJ 700 SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE INTERCOSTAL DD4 PN:601R318081-1 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR VNAA202005209999Intercostal · corrodedPAX DOOR INTERCOSTAL DD3 IS CORRODED PN:601R318056-1. LOCATED,DRILLED,NEW SERVICEABLE PAX DOOR INTERCOSTAL DD5 PN:601R5138056-1 IAW CRJ 700 SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE INTERCOSTAL DD3 PN:601R318056-1 IAW CRJ 700 SRM 51-42-06-001-001-A0SDR VNAA202005209998Former · corrodedPAX DOOR AFT FORMER FS347.27 CORRODED AT PAX DOOR WHEEL SUPPORT MOUNT AREA, FORMER PN:601R318034-3. REPAIRED IAW REO CL600-2C10-52-L06437 DATED 4/23/20.SDR VNAA202005209997Intercostal · crackedPAX DOOR INTERCOSTAL DD7 CRACKED PN:601R318825-1. REMOVED INTERCOSTAL DD7 IAW CRJ700 SRM 51-42-06-001-001-A01. LOCATED AND DRILLED UP NEW PAX DOOR INTERCOSTAL P/N: 601R318825-1 IAW CRJ700 SRM 51-40-11-001-001-A01, REV.37 AUG 15/2019. INSTALLED INTERCOSTAL DD7SDR VNAA202005209996Intercostal · corrodedPAX DOOR INTERCOSTAL CORRODED, AFT SIDE OF DOOR PN:601R31402-317. REMOVED INTERCOSTAL IAW CRJ700 SRM 51-42-06-001-001-A01. LOCATED AND DRILLED UP NEW PAX DOOR INTERCOSTAL P/N: 601R31902-317 ON AFT SIDE IAW CRJ700 SRM 51-40-11-001-001-A01, REV.37 AUG 15/2019. SDR VNAA202005209995Intercostal · crackedPAX DOOR INTERCOSTAL DD1 IS CRACKED, PN:601R31902-318. LOCATED AND DRILLED UP NEW INTERCOSTAL DD1 P/N: 601R31902-318 ON PAX DOOR. INSTALLED INTERCOSTAL DD1 IAW CRJ700 SRM 51-42-06-001-001-A01.SDR VNAA202005209994Intercostal · corrodedPAX DOOR INTERCOSTAL DD6 IS CORRODED PN:601R318057-1. LOCATED,AND DRILLED NEW SERVICEABLE PAX DOOR INTERCOSTAL PN:601R318057-1. INSTALLED NEW SERVICEABLE INTERCOSTAL DD6 IAW CRJ 700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01.SDR VNAA202005209993Skin · corrodedUPON REMOVAL OF PAX DOOR STAIR WEB ASSY, FOUND INNER SKIN TO HAVE SEVERAL ELONGATED HOLES AND AREAS OF CORROSION. LOCATED, AND DRILLED FASTENER HOLES ON NEW INNER SKIN PN:601R318024-7. INSTALLED PAX DOOR INNER SKIN IAW CRJ700 SRM 51-42-14-001-001-A01, 51-42-0SDR VNAA202005209992Stiffener · crackedUPON REMOVAL OF PAX DOOR FWD WEB, FOUND STIFFENER 2ND FROM BOTTOM TO BE CRACKED. LOCATED AND DRILLED NEW STIFFENER 601R317742-1 AND INSTALLED IAW CRJ 700 SRM 51-40-11-001-010-A01 AND 51-42-06-001-001-A01.SDR VNAA202005209991Former · corrodedPAX DOOR FWD FORMER IS CORRODED JUST INSIDE CUTOUT FOR 832FL PANEL. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE PAX DOOR FWD FORMER PN:601R318031-5SDR SWIA2020060951012Drag Angle · crackedPASSENGER DOOR AFT DRAG ANGLE IS CRACK IN PREVIOUS REPAIR AREA. (C-CHECK) RO 4/23/2020 PASSENGER DOOR AFT DRAG ANGLE WAS PREVIOUSLY REPAIRED PER REO. REMOVED DAMAGE ANGLE SECTION AND INSTALLED NEW SERVICEABLE ANGLE SECTION P/N 670-52-11-072-1 ON PASSENGER DOOSDR GTIA2020052135183Bottle · low pressureL2 DOOR ASSIST BOTTLE PRECHARGE LAW.-SERVICED L2 DOOR ASSIST BOTTLE TO PROPER PSI IAW AMM 52-10-00SDR GTIA2020052135182Diaphragm · brokenL1 DOOR ASSIST DIAPHRAM BROKEN-REPLACED L1 DOOR ASSIST BOTTLE DIAPHRAM IAW AMM 52-22-00 ALL CHECKS ARE GOOD.SDR AALA2020052289010Damper · failedAIRCRAFT IN BASE MAINTENANCE: DURING OPERATIONAL TEST R-1 DOOR DAMPING FUNCTION DOES DECREASE DOOR SPEED DURING OPENING TRAVEL. REPLACED R-1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-11-14.SDR VNAA2020051901101Door Seal · damagedDURING CLIMB OUT OF PNS, AT FL200 CREW BEGAN HEARING POPPING NOISE AND BEGAN TO FEEL PRESSURE DROPPING. CREW NOTICED CABIN ALT RISING. CREW DONNED O2 MASKS, BEGAN EMERGENCY DESCENT AND DECLARED AN EMERGENCY WITH ATC. CREW RECEIVED NO WARNINGS AND CABIN ALT NSDR AALA202005189005Bottle · low pressureAIRCRAFT NOT GROUNDED - R3 DOOR ASSIST BOTTLE, LOW PRESSURE. SERVICED R3 DOOR ASSIST BOTTLE PER A321 AMM 52-10-00.SDR AALA202005189004Bottle · low pressureAIRCRAFT NOT GROUNDED - R2 DOOR ASSIST BOTTLE, LOW PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE PER A321 AMM 52-10-00.SDR AALA202005189003Bottle · low pressureAIRCRAFT NOT GROUNDED - L2 DOOR ASSIST BOTTLE, LOW PRESSURE. SERVICED L2 DOOR ASSIST BOTTLE PER A321 AMM 52-10-00.SDR SWIA2020062651256Fairing · crackedPAX DOOR HINGE FAIRING 141AL IS CRACKED. (C-CHECK) RO 6/24/2020 ORDERED, RECEIVED AND LOCATED/DRILLED NEW PAX DOOR HINGE FAIRING 141AL REF SRM. SEE JOB 710158105 & 20979966 FOR FAIRING INSTALLATION.SDR GTIA2020051835177Bottle · low pressureDURING WEEKLY CHECK . FOUND L1 DOOR ASSIST BOTTLE BELOW -SERVICED L1 DOOR TO PROPER LIMITS IAW AMM 52-10-00-614-001 NO LEAKS DETECTED AT THIS TIME.SDR GTIA2020051835176Bottle · lowRH FWD PASS DOOR ASSIST BOTTLE RIQ SVC -SERVICED R/H FWD DOOR ASSIST IAW AMM 52-10-00SDR AALA202005189018Roller · out of adjustAIRCRAFT IN BASE MAINTENANCE: AFT ENTRY DOOR LIGHT ILLUMINATED DURING POST CHECK TEST FLIGHT. DOOR VERIFIED CLOSED AND HANDLE STOWED. ADJUSTED LATCH ROLLERS PER AMM 52-13-00.SDR SWIA2020062651181Intercostal · corrodedCORROSION FOUND ON PAX DOOR INTERCOSTAL DD4 AT APPROX FS320.163. (C-CHECK) RO 6/24/2020 BLENDED OUT DAMAGE AND RESTORED FINISH TO INTERCOSTAL DD4. REF SRM AND INSTALLED 2 EA FASTENERS IN REPAIR AREA PER REO. COMPLIED WITH TASK CARD AND M-337.SDR SWIA202061251103Intercostal · corrodedINTERCOSTAL ON FWD SIDE DD4 CORRODED MARKED WITH GREEN TAPE (C-CHECK) RO 6/8/2020. REPLACED CORRODED INTERCOSTAL WITH NEW P/N: 601R318093-1 REF DWG AND SRM. TASK CARD COMPLIED WITH. ALL CHECKS GOOD.SDR SWAA2020051978486Screw · missingFORWARD ENTRY DOOR ASSIST HANDLE MISSING SCREW / RESECURED FWD ENTYR DOOR ASSIST HANDLE AS REQ'D S.I.P.SDR GTIA2020051835175Door · damagedDAMAGE ON BOTTOM OF R1 DOOR ( GENERAL WATCH ITEM )-PERFORMED PERMANENT REPAIR IAW SRM 52-10-00-300-003 REV.133.FOR ALL WORK PERFORMED PLEASE REF TO LTPR DO 5000999675-0010;1003177552-0010/SPIRIT EO 5211-2002 REV.00.THE REPAIR IS CAT"B" IAW SRM SRI 52-10-00-205SDR SWIA2020062651257Fastener · corrodedPASSENGER DOOR LATCH MECHANISM HAS MULTIPLE (7 EACH) CORRODED HARDWARE ON MULTIPLE COMPONENTS. (C-CHECK) RO 6/24/2020 REMOVED AND INSTALLED NEW HARDWARE ON MULTIPLE COMPONENTS AT PASSENGER DOOR LATCH MECHANISM REFERENCE AMM.SDR GTIA2020051835174Accumulator · low pressureR1 DOOR ASSIST ACCUMULATOR -SERVICED R1 DOOR ASSIST ACCUMULATOR TO PROOPER PRESSURE IAW AMM 52-10-00.SDR AALA202005159003Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R4 PAX/CREW DOOR, EMERGENCY ASSIST BOTTLE BELOW ALLOWABLE PRESSURE LIMITS. SERVICED R4 DOOR ASSIST BOTTLE PER AMM 52-10-00, OKAY FOR SERVICE.SDR AALA202005159002Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - L4 PAX/CREW DOOR, EMERGENCY ASSIST BOTTLE BELOW ALLOWABLE PRESSURE LIMITS. SERVICED L4 DOOR ASSIST BOTTLE PER AMM 52-10-00, OKAY FOR SERVICE.SDR AALA202005159001Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R2 PAX/CREW DOOR, EMERGENCY ASSIST BOTTLE BELOW ALLOWABLE PRESSURE LIMITS. SERVICED R2 DOOR ASSIST BOTTLE PER AMM 52-10-00, OKAY FOR SERVICE.SDR IPXA2020051555284Unknown · malfunctionedINSPECTION TYPE:N/AMAIN CABIN ENTRY DOOR WOULD/DID NOT SHOW DISARMED IN THE WINDOW ABOVE THE ARMING HANDLE AFTER DISARMING THE DOOR ECAM SHOWED DISARMED.INSPECTED AND FOUND DOOR OPERATING NORMAL AS PER 52 10 30 WINDOWS ABOVE ARMORY HANDLE SHOW THE DOOR IT LOCK
Back to JASC 5210