JASC 5210
Service difficulty reports · 45,713
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2020071451298Intercostal · corrodedPASSENGER DOOR AFT INTERCOSTAL AT DD4 CORRODED. (C-CHECK) RO 7/10/2020 REMOVED THE CORROSION FROM THE PAX DOOR INTERCOSTAL AFT DD4 REF SRM. BLENDED AREA FOUND TO BE OUT OF LIMITS REF SRM. WET INSTALLED AND FILLET SEALED THE PAX DOOR AFT INTERCOSTAL DD4 REF SDR SWIA2020071451297Intercostal · corrodedPASSENGER DOOR CLIP FOR FWD INTERCOSTAL AT DD6, AND AT APPROX FS320 CORRODED. (C-CHECK) RO 7/10/2020 REMOVED AND INSTALLED NEW PAX DOOR CLIP / CLEAT COMMON TO INTERCOSTAL FWD DD6 AT APPROX FS320 REF SRM AND DRAWING. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA2020070151283Beam · corrodedFWD PASSENGER DOOR LOWER BEAM HAS SEVERAL AREAS OF CORROSION. (C-CHECK) RO 6/29/2020 REMOVED AND REPLACED FWD PASSENGER DOOR LOWER BEAM DUE TO OUT OF LIMITS MATERIAL LOSS OF .041" FROM A NOMINAL THICKNESS OF .0787" AND REMAINING MATERIAL OF .0377", REF SRM.SDR AALA202006109007Terminal · looseAIRCRAFT GROUNDED - L2 DOOR, EMERGENCY EXIT IDENTIFIER INOP DURING EMERGENCY LIGHT TEST. RESEATED LOOSE TERMINAL ON L2 EMERGENCY EXIT LIGHT SIGN PER FIM 33-50-F1, OPERATIONAL CHECK OKAY.SDR AALA202006109006Bottle · low pressureAIRCRAFT NOT GROUNDED - L4 DOOR, ASSIST DAMPER LOW PRESSURE. SERVICED L4 DOOR ASSIST BOTTLE PER AMM 52-13-14.SDR FDEA2020061091164Pan · gougedL1 DOOR HAS GOUGE IN PAN AROUND HANDLE BASE. REMOVED AND REPLACED L-1 PASSENGER DOOR PER AMM 52-11-01-4.SDR FDEA2020061091158Unknown · malfunctionedUNABLE TO ARM RIGHT FWD ENTRY DOOR. OPS CHECK PER AMM 52-11-00-5, TEST SATIS, A/C OK FOR SERVICE.SDR SWIA2020071451327Plate · corrodedPASSENGER DOOR SURROUND STRUCTURE: AFT ANCHOR, SERRATED MOUNTING PLATE HAS CORROSION ON ITS OUTBOARD SIDE. (C-CHECK) RO 7/10/2020 REMOVED DAMAGED SERRATED MOUNTING PLATE FROM PASSENGER DOOR AFT ANCHOR FITTING AND INSTALLED NEW P/N 600-3801-6 REF AMM, PERFORMESDR AALA202006089009Bottle · low pressureAIRCRAFT NOT GROUNDED. R1 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED DOOR ASSIST BOTTLE PER AMM 52-10-00.SDR AALA202006089005Bottle · low pressureAIRCRAFT NOT GROUNDED - L4 DOOR, DAMPER LOW NITROGEN CHARGE. SERVICED L4 DOOR ASSIST BOTTLE TO CORRECT NITROGEN CHARGE PER AMM 52-10-00.SDR AALA202006089004Bottle · low pressureAIRCRAFT NOT GROUNDED - R3 DOOR, DAMPER LOW NITROGEN CHARGE. SERVICED R3 DOOR ASSIST BOTTLE TO CORRECT NITROGEN CHARGE PER AMM 52-10-00.SDR AALA202006089003Bottle · low pressureAIRCRAFT NOT GROUNDED - R1 DOOR, DAMPER LOW NITROGEN CHARGE. SERVICED R1 DOOR ASSIST BOTTLE TO CORRECT NITROGEN CHARGE PER AMM 52-10-00.SDR AALA202006099004Arming Lever · out of rigAIRCRAFT WAS GROUNDED. L1 DOOR SLIDE ARM LEVER IS TOUGH TO ARM (OUT OF RIG). ADJUSTED L1 DOOR SLIDE ARM LEVER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-11-22-820-001A.SDR SWIA2020080751676Intercostal · corrodedPAX DOOR DD2 MID INTERCOSTAL CORRODED. INSTALLED A NEW INTERCOSTAL IAW SRM AND DWG.SDR SWIA2020080751675Intercostal · corrodedPAX DOOR DD4 MID INTERCOSTAL CORRODED. INSTALLED A NEW INTERCOSTAL IAW SRM AND DWG.SDR SWIA2020080751674Angle · corrodedPAX DOOR ANGLE DD7A FWD OF BS 325 WAS CORRODED. INSTALLED A NEW ANGLE IAW SRM AND DWG.SDR SWIA2020080751673Intercostal · corrodedPAX DOOR INTERCOSTAL DD7A AFT OF FS320 CORRODED. (C-CHECK) RO 8/5/2020 INSTALLED NEW INTERCOSTAL REF CRJ 700 SRM , AND DWG. COMPLIED WITH TASK CARDSDR SWIA2020080751672Intercostal · corrodedPAX DOOR AFT DD5 INTERCOSTAL CORRODED. INSTALLED A NEW INTERCOSTAL IAW SRM AND DWG.SDR SWIA2020080751671Intercostal · corrodedPAX DOOR AFT DD2 INTERCOSTAL CORRODED. INSTALLED A NEW INTERCOSTAL IAW SRM, AND DWG.SDR SWIA2020080751670Intercostal · dentedPAX DOOR FWD DD1 INTERCOSTAL DENTED IN RADIUS. REMOVED AND INSTALLED A NEW INTERCOSTAL IAW SRM AND DWG.SDR SWIA2020080751669Former · crackedPAX DOOR FORMER FS329 CRACKED. INSTALLED A NEW FORMER IAW SRM AND DWG.SDR SWIA2020080751668Angle · crackedPAX DOOR ANGLE FS333 CRACKED. REMOVED AND INSTALLED A NEW PAX ANGLE IAW SRM AND DWG. RESTORED FINISH IAW SRM.SDR SWIA2020080751667Former · crackedPAX DOOR FORMER CRACKED AT BS 333. REMOVED AND INSTALLED A NEW PAX DOOR FORMER IAW SRM, AND DWG.SDR SWIA2020080751666Intercostal · crackedPAX DOOR AFT DD7 INTERCOSTAL CRACKED. REMOVED AND INSTALLED A NEW INTERCOSTAL IAW SRM AND DWG,SDR ABXA20200722148Skin · crackedCRACK L1 DOOR AT AFT LOWER INNER RADIUS. AIRCRAFT WAS GROUNDED.SDR AALA2020060879001Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE - R4 DOOR DAMPER EMERGENCY CYLINDER FOUND AT 800 PSI. CHARGED R4 DOOR ASSIST BOTTLE PER AMM 52-10-00, NO LEAKS NOTED, OKAY FOR SERVICE.SDR QXEA2020060700175Bumper · brokenFORWARD MAIN CABIN DOOR OUTER RELEASE HANDLE STOP BUMPER BROKEN. REMOVED FROM SERVICE. REPLACED FWD MCD OUTER HANDLE BUMPER STOP WITH NEW FROM STOCK. OPS CK GOOD. RETURNED TO SERVICE.SDR AALA2020060539003Bottle · low pressureAIRCRAFT NOT GROUNDED - L1 DOOR EMERGENCY CYLINDER ACCUMULATOR PRESSURE IS LOW. SERVICED L1 DOOR ASSIST BOTTLE PER AMM TASK 52-10-00-614-001.SDR ASAA2020060432774Door · lack of lubeF/A REPORTS L-1 DOOR DIFFICULT TO OPEN. GROUNDED - YES. REMOVED DOOR SLIDE & LINER FROM L-1 DOOR. LUBED L1 DOOR AS REQUIRED REF AMM 25-66-07 & REF AMM 52-11-31. DOOR OPERATES NORMAL.SDR SWIA2020080751699Cup · corroded* THE PAX DOOR INTERNAL SURROUND FUSELAGE SIDE FWD HANDRAIL CUP HAS CORROSION. REMOVED CORROSION FROM PAX DOOR SURROUND FWD. CLOSING FITTING (HANDRAIL CUP). IAW SRM. FOUND TO BE OUT OF LIMITS AND REPLACED WITH NEW IAW SRM. RESTORED FINISH IAW SRM.SDR AALA2020060329013Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE. R4 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R4 DOOR ASSIST BOTTLE PER AMM 52-10-00. LEAK CHECK GOOD.SDR AALA2020060329012Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE. R3 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R3 DOOR ASSIST BOTTLE PER AMM 52-10-00, LEAK CHECK GOOD.SDR VNAA202006029991Drag Angle · crackedPAX DOOR AFT DRAG ANGLE IS CRACKED. INSTALLED NEW DRAG ANGLE.SDR VNAA202006019992Web · buckledPASSENGER DOOR AFT DRAG ANGLE REPAIR HAS A RIVET PUSHING AFT WEB AWAY FROM DRAG ANGLE, WEB SHOWS SIGNS OF BUCKLING. REPAIRED IAW EA 70-2020-111.SDR SIMA2020060131001Guide · dirtyFLIGHT ATTENDANT STILL REPORTING PAX DOOR STICKY & DIFFICULT TO OPEN, 2ND WRITE UP ON ISSUE. CLEANED DOOR GUIDES AND LUBED ROLLERS, PERFORMED DOOR OPEN AND CLOSE IAW AMM 52-18-00 SEVERAL TIMES. DOOR IS OPERATING AS REQUIRED, DOES NOT STICK, ACFT RELEASED FORSDR SWAA2020060387946Handle · looseASSIST HANDLES LOOSE AT L-1 DOOR AFT OF DOOR, ON R-1 DOOR AND ON G-1 GALLEY. TIGHTENED ASSIST HANDLES AT L-1 DOOR AFT OF DOOR, ON R-1 DOOR AND ON G-1 GALLEY IAW AMM 25-21-31-420-802 STEP 3B(6), AMM 52-41-31-400-802 STEP 3F(2) AND CMM 25-31-03 STEP 2A.SDR R61A2020060200514Flap · dirtyDOOR R2 ARM VENT FLAP LEVER VERY DIFFICULT TO ACTUATE. CLEANED AND LUBED R2 ARM VENT FLAP, OPS CHECK GOOD.SDR SWAA2020062988361Door · abnormalFWD ENTRY DOOR IS SAGGING. REMOVED FWD ENTRY DOOR IAW AMM 52-11-00-000-802. REMOVED AND REPLACED UPPER AND LOWER TORQUE TUBE BEARINGS IAW SOPM 20-50-03. REMOVED AND REPLACED UPPER AND LOWER TORQUE TUBE SPIGOTS IAW AMM 52-11-41-400-802 AND DWG 141A6270, REV ASDR AALA2020060209003Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE. R4 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2020060135189Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW PRESSURE. SERVICED L1 DOOR ASSIST ACCUMULATOR PRESSURE IAW AMM 52-10-00-614-001 TO ALLOWABLE PRESSURE RANGE. AIRCRAFT OK FOR SERVICE.SDR FDEA202005291078Battery · dischargedPOST FLIGHT INSPECTION. L-1 DOOR EPAS BATTERY PACK STATUS LIGHT NOT FLASHING. REMOVED AND REPLACED THE 2 9V BATTERIES FOR THE L-1 EPAS BATTERY PACK IAW AMM 52-11-20-4-2. RE-ARMED L-1 EPAS SYS AND GREEN STATUS LT RESTORED. NORMAL ITEM OK FOR SERVICE.SDR QXEA2020052800172Bumper · defectiveRAMP PERSONNEL UNABLE TO OPEN MAIN CABIN DOOR FROM OUTSIDE, UNABLE TO GET FINGERS IN RECESS TO GRAB THE HANDLE FASTENER, OPENED DOOR FROM INSIDE. REMOVED FROM SERVICE. REPLACED BUMPER STOP ASSY REF MCN 6520839-01, DOOR OPENS FROM OUTSIDE AS NORMAL. OK FOR SSDR GTIA2020052835188Bottle · low pressureL1 DOOR ASSIST ACTUATOR NEEDS SERVICING. SERVICED L1 DOOR ASSIST ACTUATOR IAW AMM 52-10-00.SDR SWIA2020080751642Former · corrodedPASSENGER DOOR, FWD FORMER CORRODED AROUND LOWER TENSION TIE. REMOVED AND INSTALLED A NEW PAX DOOR FWD FORMER IAW SRM, AND DWG. NO LEAKS NOTED.SDR SWIA2020062351156Intercostal · corrodedPAX DOOR MID DD3 INTERCOSTAL P/N 601R318056-1 HAS EXFOLIATED CORROSION. (C-CHECK) RO 6/21/2020 REMOVED CORRODED PAX DOOR DD3 INTERCOSTAL AND REPLACED WITH NEW REFERENCING SRM AND DWG. LEAK CHECK GOOD. COMPLIED WITH TASK CARD. COMPLIED WITH FORM M-337.SDR SWIA2020062351155Intercostal · corrodedPAX DOOR AFT DD4 INTERCOSTAL P/N 601R31902-317 HAS EXFOLIATED CORROSION. (C-CHECK) RO 6/21/2020 REMOVED CORRODED PAX DOOR DD4 INTERCOSTAL AND REPLACED WITH NEW REFERENCING DWG, SRM. LEAK CHECK GOOD. COMPLIED WITH TASK CARD. COMPLETED FORM M-337.SDR SWIA2020062351154Cleat · corrodedPAX DOOR CLEAT P/N 600-31902-269 HAS EXFOLIATED CORROSION AT F/S 320.00 BETWEEN FWD AND MID DD4 INTERCOSTAL. (C-CHECK) RO 6/21/2020 PAX DOOR CLEAT P/N 600-31902-269 REMOVED AND INSTALLED NEW CLEAT AT F/S 320.00 BETWEEN FWD AND MID DD4 INTERCOSTAL IAW SRM AND SDR SWIA2020062351153Intercostal · corrodedPAX DOOR MID DD4 INTERCOSTAL P/N 601R318081-1 HAS EXFOLIATED CORROSION. (C-CHECK) RO 6/21/2020 REMOVED CORRODED PAX DOOR DD4 INTERCOSTAL AND REPLACED WITH NEW REFERENCING SRM AND DWG. LEAK CHECK GOOD. COMPLIED WITH TASK CARD. COMPLETED FORM M-337.SDR SWIA2020062351152Cleat · corrodedPAX DOOR CLEAT P/N 600-31902-269 HAS EXFOLIATED CORROSION AT FS 321.00 BETWEEN FWD AND MID DD1A INTERCOSTAL. (C-CHECK) RO 6/21/2020 PAX DOOR CLEAT P/N 600-31902-269 REMOVED AND INSTALLED NEW CLEAT AT FS 321.00 BETWEEN FWD AND MID DD1A INTERCOSTAL IAW SRM ANDSDR SWIA2020062351150Intercostal · corrodedPAX DOOR MID DD2 INTERCOSTAL HAS EXFOLIATED CORROSION. (C-CHECK) RO 6/21/2020 REMOVED CORRODED PAX DOOR DD2 INTERCOSTAL AND REPLACED WITH NEW REFERENCING DWG, SRM. LEAK CHECK GOOD. COMPLIED WITH TASK CARD. COMPLETED FORM M-337.
Back to JASC 5210