JASC 5210
Service difficulty reports · 45,724
Reports filed under 5210 · Passenger/Crew Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5210' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2013102809257Angle · corrodedPASSENGER DOOR MID CAP ANGLE IS CORRODED. R & R ANGLE AT PAX DOOR MID CAP IAW SRM 51-42-06-001-001-A01.SDR SWIA201334838Lever · chafedPAX DOOR FWD PULL IN LEVER CHAFED. C-CHECK REPLACED PAX DOOR FWD PULL IN LEVER IAW AMM.SDR REXA2013092401895Lever · chafedMAIN ENTRY DOOR FWD PULL-IN LEVER IS CHAFED. BLENDED AREA WITHIN LIMITS IAW REO 670-52-11-138.SDR A6WA2013100200242Support · looseFWD HAND RAIL SUPPORT HAS LOOSE FASTENERS. R & R WITH NEW PARTS UPPER TUBE, UPPER TUBE FITTING, LOWER TUBE IAW SRM 51-40-11.SDR USAA2013092600015Bottle · low pressure2S CHECK - LEFT FORWARD EMERGENCY DOOR ASSIST BOTTLE PRESSURE LOW. REPLACED DIAPHRAM PIN & SEALS ON LT FORWARD EMERGENCY DOOR ASSIST BOTTLE & SERVICED TO PROPER PRESSURE IAW AMM 52-10-00-610-001-A.SDR R61A201309240914Mechanism · lack of lubeCREW REPORTED THAT THE L1 DOOR WAS HARD TO OPEN. MX LUBED THE L1 DOOR LOCKING MECHANISM IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.SDR N6WA20130924001Lanyard · brokenMAIN CABIN DOOR PIN LANYARD BROKEN. R & R FWD MAIN DOOR CABIN LANYARD & PIN IAW AMM 52-11-05.SDR CALA2013092400694Stop Fitting · damagedL1 DOOR STOP FITTING ASSEMBLY 4TH FROM TOP, FWD SIDE STILL DAMAGED & REQUIRES REPLACEMENT. PRE-PILOTED FITTING ASSEMBLY PN 141A610 3-5 ALREADY RECEIVED. REMOVED & INSTALLED NEW DOOR STOP FITTING ON L1 DOOR IAW SRM 51-40-02 & 52-10-90.SDR SIMA20130923007Structure · dentedMAIN PAX DOOR DENTED 10 INCHES FROM AFT EDGE 15 INCHES FROM BOTTOM. PERFORMED PERMANENT REPAIR IAW EO EM-5200-329.SDR SIMA20130923009Structure · dentedMAIN PAX DOOR DENTED. PERFORMED PERMANENT REPAIR IAW EO EM-5200-329.SDR REXA2013092301888Guide · chafedMAIN ENTRY DOOR, FWD GUIDE PLATE IS CHAFED. BLENDED OUT DAMAGE IAW SRM 51-12-00, REF MM 409, 362942 EO R52095. C/W OPS CHECK IAW AMM 52-00-00, CHECK GOOD. PN MS20426AD6-8.SDR CALA2013092491381Lens · missingDOOR 1L ARM-DISARM INDICATOR PLEXIGLAS LENS MISSING. REPLACED LENS.SDR N6WA20130923001Pin · missingPAX DOOR HANDRAIL PIN MISSING. REPLACED MAIN CABIN DOOR HANDRAIL FWD PIN IAW AMM 52-11-05.SDR CALA2013092391335Skin · crackedTHE INNER SKIN OF THE L4 DOOR IS CRACKED AT THE EDGE OF HOLE. REPAIRED L4 DOOR INNER SKIN IAW ECRA 5210-02424, APPLIED CIC.SDR CALA2013092391334Skin · crackedL4 DOOR INNER SKIN CRACKED FWD UPPER. REPAIRED L4 DOOR IAW ECRA 5210-02424 APPLIED CIC TO REPAIR AREA.SDR USAA2013092300045Bottle · low pressureCIDS CAUTION LIGHT IS ILLUMINATED. FOUND DOOR 3R DOOR DAMPER LOW. SERVICED 3R DOOR DAMPER BOTTLE IAW AMM 52-50-00-614-002A.SDR SIMA20130922002Handle · malfunctionedF/A REPORTS MAIN DOOR HANDLE ROTATES TO CLOSED POSITION WHEN DOOR ABOUT HALF OF THE WAY TO FULL OPEN POSITION. LUBRICATED DOOR HANDLE MECHANISM. NO DEFECTS NOTED.SDR GLBA2013092500323Pin · lack of lubePILOT REPORTED THAT THE FWD ENTRY DOOR IS VERY HARD TO OPEN FROM THE INSIDE AND OUTSIDE. MAINTENANCE CLEANED AND LUBRICATED LOCKING PINS OPS CHECKED GOOD IAW MM 52-11-00.SDR SWIA201334848Structure · chafedPAX DOOR VENT DOOR CHAFED ON INBD SIDE 3 PLACES. C-CHECK BLENDED IAW REO.SDR UHLA2013092000428Door · out of adjustL1 DOOR SEEMS HARD TO CLOSE. PERFORMED VERTICAL ADJUSTMENT OF L1 DOOR IAW AMM 52-11-00-820-802A, OPS CHECK GOOD.SDR ASOA2013092309071Drag Angle · crackedPAX DOOR DRAG ANGLE CRACKED. ORIGINATING FROM RIVET HOLE AND CRACK IN RADIUS , MID-POINT OF ANGLE. REPAIRED IAW REO 601R-52-11-2184, REV A.SDR GTIA20130920974Bottle · low pressureDOOR ASSIST BOTTLE LOW PRESSURE. ASSIST BOTTLES SERVICED IAW AMM 52-10-00-614-001.SDR GTIA20130920973Cylinder Damper · low pressureL1 + R1 DOOR ASSIST ACCUM PRESS LOW. SERVICED L1+R1 DOOR ASSIST TO CORRECT PRESS IAW AMM.SDR R61A201309190939Dampener · corrodedDURING HEAVY CHECK, L2 DOOR DAMPENER CORRODED. MX R & R L2 DOOR DAMPENER IAW AMM 52-12-27-04.SDR SWAA2013092320380Handle · looseL1 DOOR EMERGENCY EVAC SLIDE MANUAL RELEASE HANDLE LOOSE. SECURED HANDLE IAW MT.SDR CALA2013092091313Lens · missingAFT LT EXIT DOOR "ARMED" LIGHT MISSING. LENS ASSEMBLY IS MISSING, COULD NOT LOCATE. REPLACED DOOR 4 LEFT LENS CAP ASSEMBLY IAW AMM 52-11-96.SDR CALA2013092091289Cable · out of adjustL4 DOOR POWER RESERVOIR CABLE TRAVEL CHECK NOT WITHIN LIMITS. ADJUSTED CABLE TRAVEL IAW AMM 52-11-36. INSTALLED L4 DOOR POWER RESERVOIR BOTTLE IAW AMM 52-11-30.SDR GTIA20130919970Cylinder · low pressureL2 DOOR ASSIST CYLINDER HAS LOW PRESSURE. SERVICED L2 DOOR ASSIST CYLINDER IAW AMM 52-10-00-614-001.SDR SWIA201334804Lever · chafedPAX DOOR FWD PULL IN LEVER CHAFED. C-CHECK BLENDED DAMAGED AREA ON PAX DOOR FWD PULL IN LEVER IAW REO.SDR A6WA20131001215Hinge · corrodedDOOR UPPER STEP HINGE HAS DEEP PITTING AND REQUIRES REPLACEMENT. INSTALLED SERVICEABLE IAW SRM 51-41-02.SDR CALA2013092091308Skin · crackedL4 DOOR INNER SKIN OPENING CRACKED FWD UPPER. REPAIRED L4 DOOR INNER SKIN IAW ECRA 5210-02424. HFEC TRIMMED AREA IAW NDT MANUAL 51-00-19. NO CRACKS FOUND.SDR N6WA20130908002Step · loosePAX DOOR STEP HAS LOOSE AND MISSING HARWARE. REPLACED AND RETORQUED HARDWARE ON PAX DOOR IAW AMM 20-21-00.SDR SIMA20130918004Roller · lack of lubeMAIN CABIN ENTRY DOOR IS HARD TO OPEN. F/O FOUND IT HARD TO OPEN ALSO. PERFORMED LUBRICATION ON ROLLERS AND ACTUATING AND LOCKING MECHANISM ON MAIN DOOR IAW AMM 52-11-00.SDR SIMA20130917005Door · dirtyF/A REPORTS MAIN CABIN DOOR IS DIFFICULT TO OPERATE. CLEANED, LUBED AND PERFORMED OPS CHECK OF MAIN DOOR IAW AMM 52-10-01. CLEANED AND LUBED DOOR ROLLERS, REQUIRED 30LBS ON FISH SCALE TO OPEN.SDR UHLA2013091600475Diaphragm · puncturedL1 DOOR ASSIST BOTTLE FAILED PRESSURE CHECK. INSPECTED PNEUMATIC ASSY IAW AMM 52-11-51, FOUND DIAPHRAGM PUNCTURED. R & R DIAPHRAGM IAW AMM 52-11-53. SERVICED L1 DOOR PNEUMATIC ASSY TO 2250 PSI. LEAK CHECKED GOOD.SDR SWIA201334764Sill · corrodedPAX DOOR, ENTIRE LENGTH OF DOOR SILL AT STRINGER 18 CORRODED. C-CHECK REPLACED PAX DOOR SILL ANGLE IAW SRM.SDR N6WA20130916001Cable · frayedMAIN PAX DOOR CABLE FRAYED. R & R MAIN PAX DOOR CABLE IAW AMM 52-11-08, OP'S CHECKED GOOD AT THIS TIME.SDR SIMA20130916004Door · lack of lubeTHE MAIN CABIN DOOR IS HARD OPEN. LUBRICATED MAIN CABIN CABIN DOOR FRAME ROLLERS IAW AMM 53-21-02. TESTED SATISFACTORY.SDR JJBA20130916009Bolt · loosePASSENGER DOOR WARNING LIGHT ILLUMINATED IN FLIGHT. TIGHTENED UPPER FWD AND AFT DOOR SHELL BOLTS. SEALED BOLT HEADS. PRESSURIZATION AND OPS CHECKED GOOD.SDR USAA2013091900004Gate · corrodedC4 CHECK, CORROSION FOUND ON L4 DOOR LOWER GATE AT BS 1661, LBL 66. REPLACED GATE IAW SRM 52-10-02-1A-1 & CMM 52-11-25.SDR R61A201309150876Deflector · wornCREW REPORTED THAT THE L1 DOOR WAS MAKING A LOUD VIBRATION & HUMMING NOISE IN FLIGHT. AN EMERGENCY WAS NOT DECLARED AND CREW LANDED WITHOUT INCIDENT. MX FOUND THE L1 DOOR DEFLECTOR WORN. MX REMOVED DOOR DEFLECTOR AND PLACED ON CDL IAW AMM. ACFT IS GOOD FOR SDR GTIA20130915968Bottle · low pressureL1 DOOR ASSIST ACTUATOR PRESSURE LOW. SERVICED L1 DOOR ASSIST IAW AMM.SDR N6WA20130915002Cable · brokenPAX DOOR ASSIST CABLE BROKEN.SDR F3LA2013101500913Lock · dirtyDURING C8/S2 CHECK. AFT ENTRY DOOR FAILS OPS TEST OF THE INTERLOCK MECHANISM. DISASSEMBLED, CLEANED AND REASSEMBLED, EMERGENCY CONTROL HANDLE IAW AMM 52-13-22-000-002-A, PARA 4.A.(4), AMM 52-13-22-400-001-A, PARA 4.F (18) THROUGH (21) AND AMM 52-10-00-710-002SDR R61A201309140871Bottle · dischargedCREW REPORTED THAT THE L1 DOOR WAS NOT CLOSING ALL THE WAY. MX FOUND THE L1 DOOR ASSIST BOTTLE DISCHARGED AND THE GIRT BAR WAS ENGAGED WITH THE HANDLE IN THE OPEN POSITION. MX WAS ABLE TO GET THE DOOR CLOSED BUT DID NOT HAVE ENOUGH NITROGEN TO SERVICE THE DOSDR GTIA20130914966Bottle · low pressureL2 DOOR ASSIST PRESSURE LOW. SERVICED L2 DOOR ASSIST TO PROPER PRESSURE IAW AMM. LEAK CHECKED GOOD.SDR GTIA20130914965Bottle · low pressureL1 DOOR ASSIST PRESSURE LOW. SERVICED L1 DOOR ASSIST TO PROPER PRESSURE IAW AMM. LEAK CHECKED GOOD.SDR GTIA20130914964Bottle · low pressureR1 DOOR EMERGENCY ACTUATOR PRESSURE LOW. SERVICED R1 DOOR ACTUATOR IAW AMM TO PROPER LEVEL.SDR GTIA20130914963Bottle · low pressureL1 DOOR EMERGENCY ACTUATOR PRESSURE LOW. SERVICED L1 DOOR ACTUATOR IAW AMM TO PROPER LEVEL.SDR 9JLA2013111806425Cable · brokenFLIGHT CREW REPORTED THAT THE MAIN ENTRY DOOR LIFTING SYSTEM WAS INOPERATIVE. TROUBLESHOOTING IDENTIFIED THE DOOR LIFT CABLE BROKE. THE SYSTEM WAS DISABLED WHILE MFG SEARCHED THE WORLD FOR A REPLACMENT CABLE. POOR PARTS SUPPORT, 6 WEEKS FOR REPLACEMENT CABLE
Back to JASC 5210