SDR DALA2026101905742Beam · corrodedR4 DOOR BEAM BETWEEN FR 75 TO 76 UNDER THRESHOLD HAS CORROSION ON TOP INBOARD SURFACE. CORRECTIVE ACTION: REPLACED BEAM PER A330 SRM 51-42-00. (1869995) AIRCRAFT WAS GROUNDED.SDR AALA202610199773Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR 1R CHECK DOOR PRESSURE INDICATION BEFORE PUSHBACK. MAINTENANCE CHARGED R1 DOOR TO THE CORRECT PRESSURE PER AMM 52-10-00. OPS CHECKED GOOD. NO LEAKS NOTED AT THIS TIME.SDR JR2R20261015739Fitting · chafedAFT SERVICE R2 DOOR VENT FLAP INTERNAL HANDLE FITTING IS CHAFED. REPAIRED PER ETD.