Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2019082000320Beam · crackedSERVICE DOOR #2 BEAM CRACKED BETWEEN FASTENERS. REPLACED #2 BEAM ON AFT SERVICE DOOR WITH NEW PART PN 85217419-104 IAW SRM 51-20-00-00-01, 51-23-00-00-01, 51-40-07-02-01, 51-40-15-02-01, 51-42-05-02-01 AND 51-42-45-02-01.SDR AALA201908129006Damper · low pressureAIRCRAFT WAS NOT GROUNDED: RIGHT HAND AFT CREW DOOR DAMPER REQUIRED SERVICING. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-10-00.SDR AALA2019081219001Damper · low pressureAIRCRAFT WAS NOT GROUNDED: CIDS PANEL LOW PRESSURE 4R DOOR. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER JOB CARD 26L80052001.SDR DALA2019081684821Panel · detachedPASSENGER SLIDE DOOR R3 PANEL FELL OFF OF DOOR AT TOUCH DOWN. RESECURED DOOR PANEL SYSTEM OPERATION IS NORMAL.SDR AALA2019081209004Damper · low pressureAIRCRAFT WAS NOT GROUNDED: 3L DOOR DAMPER PRECHARGE PRESSURE LOW. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR GTIA2019081284543Bottle · low pressureDEU B INOPERATIVE R1 DOOR INDICATION ON FAP PANEL. CABIN INTERCOMMUNICATION DATA SYSTEM (CIDS) CIDS DEU B. FOUND THE R1 DOOR ASSIST PRESSURE LOW. SERVICED IAW AMM 52-10-00. OPS CHECKED AND INDICATION GOOD.SDR AALA201908099013Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW 1000 PSI. SERVICED R4 DOOR EMERGENCY CYLINDER ACCUMULATOR. PER AMM 52-10-00-614-001.SDR AALA201908099012Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR EMERGENCY CYLINDER ACCUMULATOR PRESSURE LOW 600 PSI. SERVICED R1 DOOR EMERGENCY CYLINDER ACCUMULATOR. PER AMM 52-10-00-614-001.SDR SWIA2019082746219Striker · corrodedSERVICE DOOR LOWER SEAL STRIKER CORRODED. REMOVED & REPLACED SERVICE DOOR STRIKER IAW SRM. ALL CHECKS GOOD.SDR DALA2019080604602Door · dirtyRT FWD DOOR OPEN INDICATION JUST AFTER TOUCHDOWN THEN EXTINGUISHED ON TAXI IN. REMOVED DEBRI FROM DOOR AREA CHECKED GOOD.SDR SWAA2019081335817Beam · crackedR1 DOOR #5 BEAM CRACKED IN FILLET AREA. / R&R R1 DOOR #5 BEAM IAW DWG.SDR SWAA2019081335816Beam · crackedR1 DOOR #4 BEAM CRACKED IN FILLET AREA. R&R R1 DOOR #4 BEAM IAW DWG.SDR REXA2019081341176Housing · crackedDURING NDT INSPECTION, CRACK OF 0.500 INCH WAS FOUND ON MAIN AVIONICS COMPARTMENT DOOR HANDLE HOUSING. NEW DOOR HANDLE HOUSING WAS REPLACED PER CRJ-900 S.R.M. 51-42-21-001-001-A01SDR DALA2019080964685Arm · fodR1 DOOR WON'T ARM. REMOVED DEBRIS FROM 1R DOOR ARMS OK PER AMM 52-11.SDR DALA2019080754642Door Sill · dirtyUNABLE TO ARM THE R1 DOOR. CLEANED DOOR SILL FROM DEBRIS. OPS NORMAL B757 AMM 52-11.SDR AALA2019080549014Damper · low pressureAIRCRAFT IN BASE MAINTENANCE: FOUND R3 DOOR DAMPER PRESSURE BELOW LIMITS. SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR AALA2019080549013Damper · low pressureAIRCRAFT IN BASE MAINTENANCE: FOUND R2 DOOR DAMPER PRESSURE BELOW LIMITS. SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR AALA2019080549008Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED: R1 CABIN DOOR EMERGENCY OPERATIONAL CYLINDER CHARGE PRESSURE WAS LOW. MAINTENANCE SERVICED DOOR ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00.SDR SWAA2019091336865Beam · crackedR1 DOOR #4 (LOWER) BEAM TO BE CRACKED IN THE RADIUS ON THE INBOARD SIDE COMMON TO THE FORWARD MOST ATTACH POINT FOR THE DOOR HANDLE BOX ASSEMBLY. REPAIRED DOOR IAW WO.SDR SWIA2019091846329Intercostal · corrodedSERVICE DOOR INTERCOSTAL AT HINGE ARM MECHANISM HAS CORROSION. (C-CHECK) RO: 09/14/19 BLENDED OUT CORRISION ON THE SERVICE DOOR INTERCOSTAL IAW SRM. ALL CHECKS GOOD AND THE CORROSION DAMAGE FOUND IS ACCEPTABLE IAW REO.SDR SWIA2019091846328Hinge Arm · chafedSERVICE DOOR HINGE ARM CHAFED. (C-CHECK) RO: 09/14/19 REMOVED CHAFE ON SERVICE DOOOR HINGE ARM IAW REO. ALL CHECKS GOOD.SDR GTIA2019080134515Door · underservicedRH REAR DOOR REQUIRES SERVING. SERVED DOOR ASSIT ON RH REAR DOOR IAW 52-10-00SDR SWAA2019081435871Access Door · corrodedSTAB TRIM ACCESS DOOR 311BL SKIN SURFACE CORRODED ON SEVERAL INBOARD AREAS. / R&R DOOR PER AMM.SDR SWAA2019073135458Beam · crackedR1 DOOR BEAMS #4 LOWER BEAM CRACKED. R&R #4 LOWER BEAM IAW SRM & DWG.SDR SWAA2019073135457Beam · crackedR1 DOOR #5 UPPER BEAM CRACKED. REPAIRED R1 DOOR UPPER #5 BEAM IAW AMM, SRM AND DWG.SDR SWAA2019073035415Beam · crackedCRACK IN DOOR HANDLE BOX LOWER ATTACH BEAM AT INBOARD ATTACH BOLT HOLE IN INSPECTION AREA. R&R THE #4 BEAM IN THE R1 DOOR IAW DWG AND CCO.SDR SWAA2022031232245None · corroded***CORROSION*** CORROSION AT R2 DOOR INNER CORD STA. 951- STA. 992.8; WL 208 RBL 43 / CORROSION ON AFT SERVICE DOR LWR SILL INNER CHORD STA 951-992.8 WL 208 208 RBL 43 FOUND TO BE OUT OF LIMITS DUE TO DAMAGE BEING WITHIN 20X OF A FASTENER HOLE IAW SRM 53-70-15SDR SWAA2022031167268Beam · crackedREF CUSTOMER CARD I14079 INSPECTION FWD SERVICE DOOR #4 AND #5 BEAMS. DURING NDT INSPECTION FOUND CRACK INDICATION IN THE INSPECTION AREA ON #5 UPPER BEAM. / REMOVED AND REPLACED #5 BEAM ON FWD SERVCIE DOOR IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND BOEING DSDR SWAA2022031167269Beam · crackedREF CUSTOMER CARD I14079 INSPECTION FWD SERVICE DOOR #4 AND #5 BEAMS. DURING NDT INSPECTION FOUND CRACK INDICATION IN THE INSPECTION AREA ON #4 LOWER BEAM. / REMOVED AND REPLACED #4 BEAM ON FWD SERVICE DOOR IAW SRM 51-40-02-0-0G-0; SRM 51-40-05-0G-0; AND BOEINSDR SWAA2019072935316Beam · crackedR1 DOOR #4 BEAM CRACKED IN RADIUS. R&R #4 BEAM IAW SRM AND DWG.SDR SWAA2022031109787Support Bracket · crackedAFT SERVICE DOOR LOWER HINGE ACCESS COVER HAS 2EA CRACKED SUPPORT BRACKETS. / REMOVED & REPLACED AFT SERVICE DOOR LOWER HINGE ACCESS COVER PANEL BRACKETS PER SRM 51-40-02-0G-0D STEP 4. FIGURE 8 & BOEING DRAWING 411A2119.SDR QXEA2019072400280Beam · crackedSERVICE DOOR 2 BEAM CRACKED. REMOVED CRACKED BEAM 2 ON SERVICE DOOR IAW SRM 51-42-05-02-01, 51-42-45-02-01 AND 51-40-07-02-01. FIT AND INSTALLED NEW BEAM 2 ON SERVICE DOOR IAW SRM 51-23-00-00-01, 51-40-07-02-07, 51-42-05-02-01, 51-42-45-02-01, 51-40-15-02-01 ASDR DALA2019070104010Service Door · corrodedSHIP 652 FWD LAV SERVICE PNL DOOR HAS CORROSION UNDER IB HINDGE. CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION REMOVED CORROSION REF SRM. FOUND LEVEL 2 CORROSION TO THE SHIMS, FABRICATED AND INSTALLED SHIMS PER DWG. (1146622)SDR CALA2019063001103Hook · worn(SUPPORT TASK) R2 DOOR HANDLE GEAR BOX HOOK WORN. REFER TO AAR N /R: 9620410. REMOVED AND REPLACED R-2 DOOR HANDLE GEAR BOX HOOK IAW CMM 52-13-15.SDR SIMA20190627001Skin · dentedTDMI PERFORM PERMANENT REPAIR OF DENT LOWER AFT CORNER OF SERVICE DOOR-C/A-PERFORMED PERMANENT REPAIR OF SERVICE DOOR LOWER AFT CORNER IAW ERS-EM-52MR-998SDR AALA201906279011Seal · failedAIRCRAFT WAS GROUNDED: ON DESCENT RIGHT AFT CABIN DOOR LEAKED LARGE AMOUNT OF WATER INTO CABIN. FLIGHT ATTENDANTS REPORTED LOUD SQUEALING NOISE. MAINTENANCE FOUND R2 DOOR SEALTO HAVE FAILED AND REPLACED SEAL PER 52-13-18 OF A320 AMM AND APPLIED SEALANT TO DOORSDR AALA201906259024Damper · low pressureAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK FOUND R2 DOOR DAMPER BELOW PRESSURE LIMITS. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER 52-22-00.SDR AALA201906259023Damper · low pressureAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK FOUND R3 DOOR DAMPER BELOW PRESSURE LIMITS. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER 52-22-00.SDR AALA201906259022Damper · low pressureAIRCRAFT WAS NOT GROUNDED: DURING PS CHECK FOUND R4 DOOR DAMPER BELOW PRESSURE LIMITS. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER 52-10-00.SDR DALA2019062503838Handle · out of alignmentR1 DOOR OUTSIDE HANDLE VISIBLE FROM INSIDE. OUTSIDE HANDLE IN BOTTOM OF WINDOW . FOUND HANDLE ON EXTERIOR NOT ALIGNED. RESEATED THE R1 DOOR HANDLE. DOOR OPS CHECKED GOOD. NO DEFECTS NOTED IAW AMM 52-11-00.SDR AALA2019062549022Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR DAMPER PRESSURE LOW. MAINTENANCE SERVICED DOOR DAMPER TO PROPER PRESSURE PER AMM 52-10-00, NO LEAKS NOTED.SDR AALA201906249026Damper · low pressureAIRCRAFT WAS NOT GROUNDED: DURING PERIODIC SERVICE CHECK, FOUND R3 EMERGENCY DOOR DAMPER LOW. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR AALA201906249028Damper · corrodedAIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS FWD SERVICE DOOR DAMPENER IS CORRODED. REMOVED AND REPLACED FWD DOOR DAMPER IAW AMM 52-41-27 AND AMM 52-41-27-820-801-A. ADJUSTMENT OKAY.SDR AALA201906249029Damper · corrodedAIRCRAFT IN BASE VISIT: MAINTENANCE REPORTS AFT SERVICE DOOR DAMPENER IS CORRODED. REMOVED AND REPLACED AFT SERVICE DOOR DAMPER IAW E190 AMM 52-42-27 AND AMM 52-42-27-820-801-A. ADJUSTMENT OKAY.SDR DALA2019062003840Handle · not seatedDURING CRUISE, THE R1 OUTSIDE DOOR HANDLE CAN BE SEEN FROM THE INSIDE OF THE ACFT. ABOUT 1 INCH OUT AND CAN SEE 2 INCHES OF THE HANDLE . OPERATED THE R1 DOOR. OPS OK. OK FOR SERVICE.SDR AALA201906219019Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R1 DOOR EMERGENCY ACCUMULATOR (DAMPER) WAS BELOW LIMITS. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR AALA201906219017Damper · low pressureAIRCRAFT WAS NOT GROUNDED: R3 DOOR EMERGENCY ACCUMULATOR WAS BELOW LIMITS. MAINTENANCE SERVICED DAMPER TO PROPER PRESSURE PER AMM 52-22-00.SDR SWAA2019070834647Beam · crackedR1 DOOR #4 BEAM CRACKED. R&R R1 DOOR #4 BEAM IAW SRM AND DWG.SDR AALA201906189002Dampener · low pressureAIRCRAFT IN BASE MAINTENANCE: R1 DOOR DAMPENER PRESSURE WAS LOW. SERVICED DOOR DAMPENER TO PROPER PRESSURE PER STANDARD PRACTICES.SDR AALA201906189004Dampener · low pressureAIRCRAFT IN BASE MAINTENANCE: R2 DOOR DAMPENER PRESSURE WAS LOW. SERVICED DOOR DAMPENER TO PROPER PRESSURE PER STANDARD PRACTICES.
Back to JASC 5240