Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2017092202177Bottle · low pressureR1 DOOR ASSIST BOTTLE BELOW 1500 PSI . SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR CALA2017092203288Insert · missingR4 DOOR SAFETY STRAP BROKEN. WARNING RIBBON ATTACH SCREW INSERT MISSING FROM DOOR LINING. INSTALLED THE INSERT AND BOLT.SDR YENA201709210784Linkage · out of adjustR2 DOOR SLIDE ARMED INDICATION GOES OFF AND ARMED WITH HANDLE IN THE ARMED POSITION. ARMING HANDLE DOES NOT FULLY STAY DOWN, BOUNCES UP SLIGHTLY FROM CLOSED (ARMED) POSITION; ADJUSTED RELEASE MECHANISM BOTTOM LINKAGE ON R2 DOOR. OPS CHECKED GOOD. PRESSURIZSDR AALA201709229003Cylinder · low pressureR1 DOOR EMERGENCY CYLINDER ACCUMULATOR IS BELOW LIMITS. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201709229029Cylinder · low pressureR4 DOOR DAMPNER DISCHARGED, PRESSURE LOW. CHARGED THE DOOR DAMPNER IAW MM 52-10-00.SDR AALA201709229028Cylinder · low pressureR2 DOOR DAMPNER DISCHARGED, IN YELLOW BAND. CHARGED THE DOOR DAMPNER IAW MM 52-10-00.SDR R61A201709190716Pushrod · chafedR2 DOOR ARMING LEVER PUSH ROD IS CHAFFED. R&R ROD ASSY FOR EMERGENCY MECHANISM IAW AMM 52-42-52. OPS TEST GOOD.SDR WVER2017091800008Angle · corrodedSERVICE DOOR MOUNTING ANGLE CORRODED.SDR AALA201709189032Cylinder · low pressureR2 DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED AS REQUIRED IAW AMM 52-22-00.SDR AALA201709189031Cylinder · low pressureR1 DOOR CYLINDER PRESSURE IS LOW. SERVICED AS REQUIRED IAW AMM 52-10-00.SDR AALA201709189030Cylinder · low pressureR3 DOOR R3 CYLINDER PRESSURE LOW. SERVICED CYLINDER TO PROPER PRESSURE IAW AMM 52-22-00.SDR AALA20170916002Cylinder · low pressureR4 ENTRY DOOR EMERGENCY CYLINDER PRESSURE READS LOW. CHARGED THE R4 CYLINDER IAW 52-10-00.SDR AALA20170916001Cylinder · low pressureR1 ENTRY DOOR EMERGENCY CYLINDER PRESSURE READS LOW. CHARGED THE BOTTLE IAW 52-10-00.SDR AALA201709189010Cylinder · low pressureWHEN DOORS ARE ARMEDK THE CIDS PANEL INDICATES CHECK DOOR PRESSURE. SERVICED THE R1 DOOR IAW AMM.SDR IPXA2017091521759Cable · damagedR1 DOOR FWD UPPER CABLE, UPPER ROD ASSY DAMAGED. R & R THE ROD ASSY IAW AMM 32-11-03.SDR IPXA2017091521754Connector · damagedR1 DOOR ELECTRICAL ACTUATOR DAMAGED AT CONNECTOR SHROUD. R&R THE ACTUATOR IAW MM 52-11-01-401, THRU STEP F(1)(D) TH 0557558 9-11-17, AND AMM 52-11-01.SDR IPXA2017091521752Torque Tube · scoredR1 DOOR FWD DRIVE TORQUE TUBE FOUND SCORED, CIRCUMFRENTIALLY NEAR SPLINED END. REMOVED AND REPLACED THE TORQUE TUBE.SDR IPXA2017091521751Cable · disconnectedR1 DOOR FOLLOW UP PANEL CABLE DISCONNECTED. CONNECTED THE CABLE AT CLEVIS.SDR AALA201709189028Cylinder · low pressureRIGHT AFT DOOR EMERGENCY CYLINDER HAD LOW PRESSURE. CHARGED THE CYLINDER TO CORRECT PRESSURE IAW AMM 52-10-00.SDR SWAA2022013109867Service Door · crackedFORWARD SERVICE GALLEY DOOR LOWER BEAM CRACKED APPROX. 1.5 INCHES AT FORWARD CAM BOX ATTACH POINT. / R&R FWD SERVICE DOOR ASSY IAW MM 52-41-00 TAG NO: 271522 PN ON: 141A6516-18 SN ON: BN001785 PN OFF: SN OFF: 1873SDR SWIA201743817Striker · corrodedLOWER SERVICE DOOR SEAL STRIKER HAS SEVERAL SPOTS OF CORROSION. INSTALLED A NEW SERVICE DOOR LOWER SEAL STRIKER IAW SRM. PRESSURIZATION LEAK CHECKED GOOD.SDR AALA201709159014Damper · low pressureR4 DOOR DAMPER PRESSURE WAS BELOW LIMITS. SERVICED THE DAMPER IAW AMM 52-22-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR IPXA2017091421712Relay · inoperativeR1 DOOR WILL NOT OPERATE. REPLACED THE R1 DOOR ACTUATOR CONTROL RELAY IAW FIM 52-11-03. TESTED GOOD.SDR SWAA2022013150972Bracket · crackedR2 AFT GALLEY DOOR LOWER PAN FWD SUPPORT BRACKET CRACKED / R&R'D R2 LOWER PAN ASSY PER AMM 52-41-31AMT 34693 INSP 33055SDR AALA201709149001Cylinder · low pressureFORWARD R1 DOOR EMERGENCY CYLINDER PRESSURE FOUND LOW. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA20170911002Bottle · low pressureR1 DOOR POWER ASSIST BOTTLE PRESSURE IS LOW. SERVICED THE BOTTLE TO NORMAL LIMITS AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR IPXA2017091221658Drive Assy · failedR1 DOOR INTERCOSTAL DAMAGED DUE TO DRIVE MECHANISM FAILURE. REPAIRED IAW EO MD11-5310-65637-ASDR IPXA2017091221663Guard · brokenR1 DOOR AFT CABLE DRUM AND SUPPORT ASSY ROLLER CHAIN GUARD BRACKET BROKEN. R & R THE CHAIN GUARD ASSY IAW MM 20-50-02.SDR AALA201709119030Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER LOW. SERVICED R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER.SDR AALA201709119029Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. L3 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER LOW. SERVICED L3 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER.SDR AALA201709119028Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. L2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER LOW. SERVICED L2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER.SDR SWIA2017100243807Plate · corrodedSERVICE DOOR STEP PLATE IS CORRODED ON THE BACKSIDE. REPLACED SERVICE DOOR STEP PLATE IAW SRM.SDR DALA2017091206840Handle · unknownDURING APPROACH, FLIGHT ATTENDANT NOTED THE HANDLE FOR THE R3 DOOR WOULD CREEP UP OUT OF DETENT. NO LIGHTS IN COCKPIT. CHECKED THE R3 DOOR FOR OPERATION, NO DEFECTS NOTED, DOOR CLOSES AND LOCKS AS REQUIRED, NO EICAS OR INDICATION IN COCKPIT WAS NOTED. OK FOR SSDR AALA201709089013Bottle · low pressureF/A REPORTS FWD CIDS PANEL DISPLAYED CHECK R2 DOOR PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM.SDR SWAA2017090816209Fitting · crackedR1 DOOR HANDLE HOUSING LOWER FITTING CRACKED. R & R THE DOOR IAW AMM.SDR AALA201709079004Lens · missingRIGHT FOWARD EXIT DOOR CABIN PRESSURE LENS IS MISSING. REPLACED R1 DOOR LENS IAW AMM.SDR AALA201709069020Lever · brokenR3 DOOR ARMING LEVER HANDLE BROKEN, YELLOW ARMED PADDLE, AND 1ST PART OF HANDLE LEVER UNATTACHED. REPLACED THE R3 DOOR ARMING LEVER IAW EA 273154.SDR QXEA2017090600548Seal · out of positionAFT GALLEY SERVICE DOOR IS TOUGH TO OPEN. BOTH INSIDE AND OUTSIDE DIFFICULT. REMOVED FROM SERVICE. R & R THE AFT SERVICE DOOR SEAL. DOOR RIG OPS CHECKED GOOD, NO FURTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR AALA201709059029Bottle · low pressureR3 DOOR ASSIST BOTTLE LOW. SERVICED THE DOOR ASSIST BOTTLE.SDR AALA20170903010Cylinder · low pressureR3 DOOR EXIT ASSIST CYLINDER PRESSURE WAS LOW, IN YELLOW BAND. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA20170903002Bottle · low pressureR1 DOOR DAMPER BOTTLE PRESSURE BELOW LIMITS. SERVICED THE BOTTLE IAW AMM 52-10-00.SDR AALA20170902003Cylinder · low pressureR4 DOOR ACCUMULATOR PRESSURE LOW. SERVICED R4 DOOR ACCUMULATOR (ACTUATOR) TO PROPER LEVEL PER AMM 52-10-00.SDR AALA20170902002Cylinder · low pressureR2 DOOR ACUMULATOR PRESSURE LOW. SERVICED THE R2 DOOR ACCUMULATOR IAW AMM 52-10-00.SDR AALA20170902001Cylinder · low pressureR1 DOOR ACCUMULATOR HAD LOW PRESSURE. SERVICED THE R1 DOOR ACCUMULATOR IAW AMM 52-10-00.SDR AALA201709019011Cylinder · low pressureR1 DOOR HAS A MESSAGE FOR CHECK DOOR PRESSURE ON THE CIDS PANEL. SERVICED THE R1 DOOR IAW AMM.SDR AALA201708319016Cylinder · low pressureR2 DOOR DAMPER CYLINDER PRESSURE LOW. SERVICED R2 DOOR DAMPER IAW AMM.SDR AALA201708319015Cylinder · low pressureR1 DOOR DAMPER CYLINDER HAS LOW PRESSURE. SERVICED R1 DOOR DAMPNER IAW AMM.SDR DALA2017083006482Door Frame · crackedCRACK INDICATION ON R1 DOOR FRAME, REPLACED THE FRAME ON R1 DOOR IAW SRM 51-72-11 AND PRI 558682-14, REV 0, REV 5 AND ER/A 558682-A14AD, REV ORIGINAL.SDR AALA20170830003Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. R1 DOOR EMERGENCY CYLINDER ACCUMULATOR PRESSURE IS LOW. SERVICED DOOR CYLINDER IAW AMM 52-10-00.SDR AALA201708309008Cylinder · low pressureINDICATION FOR CHECK SLIDE PRESSURE ANNUNCIATED ON FORWARD F/A PANEL. SERVICED THE R4 DOOR IAW AMM.
Back to JASC 5240