Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201704109055Cylinder · low pressureR4 DOOR EMERGENCY CYLINDER PRESSURE BELOW LIMITS. SERVICED THE CYLINDER IAW AMM 52-13-00. ACCOMPLISHED SATISFACTORY OPS CHECK.SDR AALA201704109052Cylinder · low pressureR2 DOOR CYLINDER PRESSURE BELOW LIMITS. SERVICED THE R2 DOOR CYLINDER IAW AMM 52-22-00.SDR DALA2017041002883Spring · brokenR1 EXTERNAL DOOR HANDLE PUSH LATCH SPRING WAS FOUND BROKEN. REPAIRED IAW ERA 557498-14, REV ORIG. REPLACED R1 DOOR HANDLE EXTERNAL PUSH LATCH RETAINER SPRING. OPS CHECKED GOOD.SDR WVER2017040702Striker · corrodedGALLEY SERVICE DOOR LOWER SEAL STRIKER CORRODED BEYOND REPAIRABLE LIMITS.SDR AALA201704079002Damper · low pressureR2 DOOR DAMPNER, HAD LOW PRESSURE. SERVICED THE R2 DOOR DAMPNER IAW AMM 52-10-00.SDR AALA201704079008Cylinder · low pressureCIDS PANEL SHOWS TO CHECK THE R1 DOOR PRESSURE, BOTTLE PRESSURE IS IN GREEN. SERVICED R1 DOOR DAMPER.SDR AALA201704079009Cylinder · low pressureR4 DOOR DAMPER REQUIRES SERVICE. SERVICED THE R4 DAMPER.SDR AALA201704079013Bottle · low pressureR1 DOOR EMERGENCY CYLINDER ACCUMULATOR HAD LOW PRESSURE. CHARGED THE BOTTLE IAW AMM 52-10-00.SDR AALA20170406006Damper · low pressureR4 DOOR DAMPER HAD LOW PRESSURE. SERVICED THE R4 DOOR DAMPER IAW 52-10-00.SDR AALA20170406001Bottle · low pressureR3 DOOR EMERGENCY ACTUATOR PRESSURE FOUND TO BE LOW. SERVICED THE R3 DOOR ACTUATOR BOTTLE IAW 52-22-00.SDR DALA2017040602762Beam · crackedCRACKED BEAM NR 3, BS 160 BETWEEN UPPER & LOWER HINGE YOKE, FORWARD RIGHT GALLEY SERVICE DOOR STRUCTURE. THE BEAM WAS REPAIRED IAW SRM 52-00-00 2R.SDR R61A201704010263Cable · dirtyR2 SERVICE DOOR REPORTED VERY DIFFICULT TO ARM. CLEANED DEBRIS FROM CABLE ON R2 DOOR IAW AMM 52-42-00. OPS GOOD.SDR AALA20170401001Cylinder · low pressureR2 DOOR EMERGENCY CYLINDER HAD LOW PRESSURE. SERVICED THE CYLINDER.SDR FDEA201703311378Skin · tornR4 DOOR INTERNAL SKIN TORN ON AFT MID SECTION OF DOOR BETWEEN BS 1647 - 1652. REPAIRED IAW EA F-5210-T0332532.SDR FDEA201703311377Skin · crackedR4 DOOR HAD THREE STOP DRILLED CRACKS ON INTERNAL SKIN BETWEEN BS 1665 - 1679 AND STOPS 4 - 5. REPAIRED IAW EA F-5210-T0332532.SDR FDEA201703311376Skin · damagedR4 DOOR INTERNAL SKIN TORN ON FWD MID SECTION OF DOOR CRACKS BETWEEN BS 1647 - 1652 AND BEAMS 2 -3. REPAIRED IAW EA F-5210-T0332532.SDR AALA201704039005Track · lack of lubeR4 DOOR ARMING LEVER DIFFICULT TO OPERATE. LUBRICATED THE DOOR ARMING TRACK.SDR AALA201704029001Cylinder · low pressureDURING CHECK OF EMERGENCY CYLINDER PRESSURE, FOUND IT TO BE LOW AT THE R2 DOOR. SERVICED CYLINDER IAW AMM 52-10-00. AIRCRAFT WAS GROUNDED.SDR AALA201704039013Bottle · low pressureCIDS PANEL SHOWING R2 DOOR CHECK PRESSURE. SERVICED THE DOOR BOTTLE WITH NITROGEN.SDR AALA201703319003Cylinder · low pressureR2 DOOR DAMPER PRESSURE FOUND IN LOWER RED ZONE. SERVICED THE R2 DOOR DAMPER TO GREEN ZONE, NO LEAKS FOUND IAW AMM 52-22-00. OK FOR SERVICE.SDR ASOA201703303064Channel · corrodedSERVICE DOOR LOWER CHANNEL CORRODED. THE CHANNEL WAS REPLACED IAW SRM 51-40-02.SDR SWAA2022011407186Door · crackedFORWARD GALLEY SERVICE DOOR MECHANISM LOWER MACHINE BEAM FWD I/B FASTENER AREA HAS A APPROX. 1.5 INCH CRACK AT THE RADIUS. / REMOVED AND REPLACED FORWARD GALLEY SERVICE DOOR PER AMM. 52-41-00 TAG NO: 225495 PN ON: 141A6516-18 SN ON: 002081 PN OFF: SN OFF: 0017SDR QXEA2017040300205Link · malfunctionedAFT SERVICE DOOR IS HARD TO OPEN. INNER LINER IS CATCHING ON THE AFT SURROUND STRUCTURE. REPLACED THE LOWER SWING LINK IAW AMM 52-41-16-400-801.SDR AALA201703319029Handle · unsecureF/A REPORTS FWD GALLEY DOOR EXTERIOR HANDLE MOVED TO UNSTOWED SOMETIME IN FLIGHT. OPERATED AND INSPECTED R-1 DOOR EXTERNAL HANDLE. HANDLE AND RETENTION SPRING. OPS CKS NORMAL IAW FIM 52-10-810. NO DEFECTS NOTED. THE AIRCRAFT WAS NOT GROUNDED.SDR AALA201703309015Indicator · contaminatedR1 DOOR DAMPER CYLINDER GAUGE SIGHT GLASS IS OPAQUE AND MAKES GAUGE UNREADABLE. REMOVED AND REPLACED THE CYLINDER.SDR R61A201703280255Seal · looseR2 DOOR SEAL MAKING FLAPPING NOISE IN FLIGHT. CLEANED AND LUBED DOOR SEAL IAW 52-00-21. PERFORMED CABIN PRESSURIZATION INSPECTION, CANNOT DUPLICATE NOISE IAW 21-31-00.SDR I5PA2017032813Skin · corrodedFORWARD ACCESS DOOR 113AL CORRODED AT AFT EDGE AND NEAR DRAIN VALVE, CORROSION LEVEL 2. REPAIRED PER ER 17-01609 REV 1R WORK DOCUMENTED ON JOB 722361 CARD 00124.SDR SIMA20170327002Profile · corrodedSERVICE DOOR UPPER AND LOWER U PROFILES NUTPLATE HOLES CORROSION. REPAIRED SERVICE DOOR UPPER AND LOWER U PROFILES NUTPLATE HOLES CORROSION IAW ERS-EM-52MR-720.SDR AALA20170328001Cylinder · low pressureR1 DOOR EMERGENCY CYLINDER PRESSURE WAS LOW. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR SWAA2017032812788Bracket · brokenR1 DOOR SLIDE BRACKET BROKEN. REPAIRED THE BRACKET IAW AMM.SDR SIMA20170326010Profile · corrodedSERVICE DOOR CORRODED AROUND LOWER NUTPLATE HOLES. REPAIRED SERVICE DOOR LOWER PROFILE IAW ERS-EM-52MR-739.SDR SIMA20170326011Frame · chafedSERVICE DOOR FWD FRAME WEB PAINT DAMAGED BTW NR 3 AND NR 5 STOP. REPAIRED SERVICE DOOR FWD FRAME WEB CHAFE BTW NR 3 AND NR 5 STOP IAW ERS-EM-52MR-738.SDR AALA201703289014Cylinder · low pressureR4 DOOR EMERGENCY CYLINDER PRESSURE LOW. SERVICED THE DOOR EMERGENCY CYLINDER IAW AMM 52-10-00.SDR VQI2017F00014Bushing · wornMX FOUND THE R1 DOOR GUST LOCK STICKING DUE TO WORN BUSHINGS. MX REPLACED THE BUSHINGS IAW AMM 52-11-12 AND TBN 52-10-01. OPS CHECKED GOOD.SDR AALA201703279023Cylinder · low pressureFOWARD FLIGHT ATTENDANT STATION PANEL SHOWS CHECK DOOR PRESSURE. MAINTENANCE CONFIRMED PRESSURE LOW. SERVICED THE R2 DOOR AS REQUIRED WITH NITROGEN.SDR AALA201703279017Cylinder · low pressureR2 DOOR EMERGENCY CYLINDER FOUND IN YELLOW BAND AT 34 DEGREES F. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201703279011Bottle · low pressureR4 DOOR BOTTLE HAD LOW PRESSURE. SERVICED THE BOTTLE IAW AMM 52-22-00.SDR FDEA201703230982Door · unknownR1 DOOR SLIDE WILL NOT ARM. RAN A R1 DOOR SLIDE ARMING TEST AND TEST OF THE ASPSU IAW MM 25-61-20-06-01 AND 52-73-00-05-02. ALL CHECKS WERE NORMAL.SDR AALA201703249001Actuator · failedR2 DOOR ASSIST ACTUATOR FIRING MECHANISM MALFUNCTIONED. REMOVED AND REPLACED R2 DOOR ASSIST ACTUATOR.SDR ASOA201703233053Channel · corrodedSERVICE DOOR LOWER CHANNEL CORRODED. THE CHANNEL WAS REPLACED IAW SRM 51-40-02.SDR AALA201703249007Damper · low pressureR1 DOOR DAMPER PRESSURE BELOW LIMITS. SERVICED THE DAMPER IAW AMM 52-11-00.SDR AALA201703239019Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESSURE NEEDLE IN RED. SERVICED R2 DOOR ASSIST BOTTLE IAW 52-22-00. AIRCRAFT WAS GROUNDED.SDR AALA201703239006Bottle · low pressureCIDS PANEL SHOWING AMBER LOW PRESSURE AT THE R2 DOOR. SERVICED R2 DOOR ASSIST BOTTLE.SDR QXEA2017032200165Cam Follower · malfunctionedAFT SERVICE DOOR HARD TO OPEN. REMOVED & REPLACED UPPER AFT CAM FOLLOWER IAW AMM 52-41-11-000-801/400-801. DOOR OPEN & CLOSE FREELY. NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR AALA201703229009Cylinder · low pressureR2 DOOR EMERGENCY CYLINDER HAD LOW PRESSURE. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR A6WA201744868Door · damagedSERVICE DOOR WILL NOT OPEN FROM THE OUTSIDE. PLUNGER APPERATUS TO BE INOPERABLE AS WELLSDR AALA201703219009Cylinder · low pressureCAUTION LIGHT ILLUMINATED ON CIDS PANEL. SERVICED R2 DOOR DAMPER.SDR AALA201703219007Handle · brokenARMING HANDLE ON R2 DOOR BROKEN OFF. REMOVED AND REPLACED THE ARMING & DISARMING UNIT. AIRCRAFT WAS GROUNDED.SDR AALA201703219004Cylinder · low pressureRECIEVED CIDS CAUTION ON DOOR 3R. SERVICING OF R3 DOOR.SDR AALA201703209034Damper · low pressureR2 DOOR DAMPER LOW PSI. SERVICED DOOR DAMPER IAW AMM 52-10-00.
Back to JASC 5240