Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2017032112578Beam · crackedR1 DOOR NR 4 BEAM CRACKED BELOW DOOR HANDLE. REPAIRED THE BEAM IAW EA.SDR IPXA2017030514717Torque Tube · chafedINSPECTION TYPE: 2C, R4 DOOR LOWER TORQUE TUBE CHAFED. REPAIRED THE TORQUE TUBE IAW EA 011-5210-01-A6673, REV I/R, AND EO MD11-5210-63432-A.SDR AALA201702129016Bottle · low pressureR4 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R4 DOOR ASSIST BOTTLE AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201702129015Bottle · low pressureR3 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R3 DOOR ASSIST BOTTLE AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201702129014Bottle · low pressureR2 DOOR ASSIST BOTTLE PRESSURE LOW. SERVICED R2 DOOR ASSIST BOTTLE AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201702129005Actuator · looseR3 DOOR EMERGENCY ASSIST ACTUATOR HAS EXCESSIVE PLAY. REPLACED THE ACTUATOR IAW AMM 52-32-14.SDR AALA20170209002Cylinder · low pressureR2 DOOR EMERGENCY CYLINDER IS LOW. SERVICED DOOR CYLINDER IAW AMM 52-10-00.SDR AALA20170210018Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. R4 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-10-00. LEAK AND OPERATIONAL CHECK GOOD.SDR AALA20170210015Cylinder · low pressureR4 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-10-00. LEAK AND OPERATIONAL CHECKED GOOD.SDR AALA201702109002Bottle · low pressureR2 DOOR SLIDE PRESSURE INDICATOR ON. SERVICED R2 DOOR ASSIST BOTTLE .SDR C77A20170209002Gusset · gougedEO E175-52MR-003 WAS ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF GOUGE DAMAGE TO THE R1 DOOR INTERNAL GUSSET PLATE, WHICH WAS DISCOVERED AT A BASIC CHECK. THE ORIGINAL APPROXIMATE GOUGE DIMENSIONS WERE 0.8 INCH X 0.3 INCH TO A MAXIMUM SDR R61A201702070102Door · dirtyCREW REPORTED THAT THE R1 DOOR VENT FLAP AND ARMING HANDLE WERE HARD TO OPERATE. MAINTENANCE CLEANED AND LUBED R2 DOOR PER EMB AMM AND OPS CHECKED GOOD.SDR AALA201702089012Bottle · low pressureAIRCRAFT IN BASE MAINTENANCE, R1 SERVICE DOOR PNEUMATIC BOTTLE NEEDS SERVICING. SERVICED R1 SERVICE DOOR PNEUMATIC BOTTLE PER AMM 52-41-51-614-801.SDR AALA201702059001Lanyard · out of positionR1 DOOR WILL NOT ARM. MAINTENANCE INSPECTED THE DOOR, REPOSITIONED LANYARD IAW AMM 25-66-00 AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR SWAA2017022211965Structure · corrodedR2 DOOR INNER STRUCTURE CORRODED. REPAIRED THE STRUCTURE IAW SRM AND DWG.SDR SWAA2017021411881Beam · crackedR1 DOOR LOWER BEAM OUTBD FORWARD CORNER CRACKED. R&R LOWER BEAM IAW SRM AND DWG.SDR SIMA20170201005Beam · crackedSERVICE DOOR FWD LWR STOP BACK UP STRUCTURE BRACKET HAS CRACK. REMOVED AND REPLACED SERVICE DOOR FWD LWR BEAM IAW SRM 51-40-02.SDR SCNA20170201011Pan · damagedR2 DOOR LOWER PAN DAMAGED. REMOVED R2 DOOR LOWER PAN. INSTALLED A NEW PAN.SDR WVER2017013100001Striker · corrodedSERVICE DOOR LOWER SEAL STRIKER IS CORRODED.SDR VNAA2017013000041Handle · crackedSERVICE DOOR OUTER HANDLE CRACKED. REMOVED AND REPLACED THE OUTER DOOR HANDLE.SDR AALA201701319014Bottle · low pressureR3 DOOR ASSIST BOTTLE HAS PRESSURE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR VNAA2017012900040Skin · damagedSERVICE DOOR LOWER PANEL DAMAGED.SDR DALA2017012900772Fitting · crackedR1 DOOR CRACKED FITTING ON BEAM NR 4 AFT EDGE. THE FITTING WAS REPLACED IAW SRM 51-30-01, 51-30-05, AND DWG 9911582 REV. T.SDR AALA201701299005Bottle · low pressureDOOR PRESSURE ON R4 DOOR AND FORWARD CABIN SCREEN SHOWS ARMED OK. MAINTENANCE SERVICED DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201701299004Bottle · low pressureR2 DOOR PRESSURE LOW. MAINTENANCE SERVICED THE R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR AALA201701299001Door · unsecureDURING CLIMBOUT, RECEIVED OPEN MESSAGE AT FORWARD SERVICE DOOR SERVICE. APPROXIMATELY 15000 FEET AND DISAPPEARED ABOUT10000 FEET. PRESSURIZATION APPEARED NORMAL, NO HISSING SOUNDS OBSERVED. MAINTENANCE PERFORMED TROUBLE SHOOTING PER FIM 52-41-00-810-803-A. INSSDR AALA201701289010Bottle · low pressureCHECK R4 DOOR PRESSURE MESSAGE. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00.SDR VNAA2017012600036Roll Pin · missingSERVICE DOOR CLOSE LATCH HANDLE FREE SPINNING. INSTALLED LOWER LATCH ROLL PIN.SDR AALA201701279002Cylinder · damagedMISSING GAUGE SEAL ON R1 DOOR ASSIST BOTTLE. REPLACED DOOR DAMPER CYLINDER IAW AMM 52-11-14-400-001-B.SDR AALA20170126010Cylinder · reads lowAIRCRAFT WAS NOT GROUNDED. R1 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-22-00. OPERATIONAL CHECK GOOD.SDR AALA201701269024Cylinder · low pressureR4 DOOR ASSIST CYLINDER IS NOT IN GREEN BAND. SERVICED R4 DOOR CYLINDER IAW AMM TASK 52-10-00-614-001.SDR AALA201701269018Reservoir · low pressureR4 DOOR ASSIT BOTTLE HAS LOW PRESSURE INDICATION. REPLACED EMERGENCY POWER RESERVOIR FOR R4 DOOR IAW AMM 52-11-30.SDR JR2R20170125271Fitting · crackedR1 DOOR HAS A CRACKED CLIP, INSIDE NEAR DOOR HANDLE. REMOVED AND REPLACED DAMAGED CLIP IAW SRM 51-30-4 AND 51-30-5.SDR SWAA2017020611724Beam · crackedR1 DOOR CRACKED ON INTERNAL STRUCTURE ON HORIZONTAL BEAM. R&R DOOR IAW AMM.SDR AALA201701249007Reservoir · low pressureDURING INSPECTION, FOUND THE L1 DOOR EMERGENCY POWER RESERVOIR PRESSURE UNSATISFACTORY. REPLACED L1 DOOR EMERGENCY POWER RESERVOIR IAW AMM 52-11-30.SDR DALA2017012300568Angle · crackedCRACKED ANGLE ON AFT SERVICE DOOR MID ZONE. THE ANGLE WAS REPLACED IAW DWG 5937918 REV Z AND SRM 51-30-1.SDR DALA2017012300535Stop Fitting · missingR4 DOOR MISSING 3 DOOR STOP PLATES ON FWD SIDE OF DOOR. INSTALLEDTHE STOP FITTING PLATES IAW AMM 52-11. OK FOR SERVICE.SDR DALA2017012000516Cam · corrodedR1 DOOR HAS SURFACE CORROSION ON THE UPPER AND LOWER CAM PLATES. REPAIRED IAW ER/A 476391-14MA, REV C, SECTION I.SDR DALA2017012000514Cam · corrodedR2 DOOR HAS SURFACE CORROSION ON THE UPPER AND LOWER CAM PLATES. REPAIRED THE CAM PLATES IAW ER/A 476391-14MA, REV C, SECTION I.SDR DALA2017012000513Cam · corrodedR4 DOOR HAS SURFACE CORROSION ON THE UPPER AND LOWER CAM PLATES. REPAIRED THE CAM PLATES IAW ER/A 476391-14MA, REV C, SECTION I.SDR DALA2017012000520Handle · malfunctionedR2 DOOR SHOWS CLOSED WITH HANDLE IN OPEN POSITION. HANDLE WILL NOT MOVE AND DOOR WILL NOT OPEN. REPOSITIONED THE R2 DOOR HANDLE TO CLOSED POSITION IAW AMM 52-11. OPS CHECKED GOOD, OK FOR SERVICE.SDR R61A201701190052Linkage · out of adjustCREW REPORTED THAT THE R2 DOOR WOULD NOT ARM. MAINTENANCE ADJUSTED THE DOOR ARM - DISARM LINKAGE IAW AMM AND OPS CHECKED GOOD.SDR DALA2017012100529Door Frame · crackedR1 SRVC DOOR HAS A CRACKED BEAM INSIDE THE CAVITY AT THE DOOR HOLD OPEN RELEASE HANDLE. REPLACED R1 SERVICE DOOR FRAME INSIDE THE CAVITY AT THE DOOR HOLD OPEN RELEASE HANDLE IAW DRAWING 9911580 AND SRM 51-41-01-OG, 51-41-02 FIG 13, AND 51-41-05 FIG 2.SDR AALA20170120009Cylinder · low pressureR4 EMERGENCY DOOR DAMPER CYLINDER PRESSURE IS LOW. SERVICED CYLINDER IAW AMM 52-10-00. LEAK AND OPERATIONAL CHECKED GOOD.SDR VQI2017F00024Lock · out of adjustTHE R1 ENTRY GUST LOCK WILL NOT ENGAGE. TECHNICIANS ADJUSTED THE DOOR LOCK ASSEMBLY IAW AMM 521112.SDR GTIA2017011601745Bottle · low pressureR3 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR VNAA2017011500018Sensor · out of adjustSERVICE DOOR CAUTION MESSAGE DURING CLIMB OUT. ADJUSTED SENSOR PX38.SDR SWAA2017012711505Beam · crackedR1 DOOR HORIZONTAL BEAM UNDER HANDLE BOX FORWARD INBOARD ATTACH BOLT CRACKED IN RADIUS. R&R BEAM IAW SRM AND DWG.SDR AALA20170113032Reservoir · low pressureR2 DOOR EMERGENCY POWER ASSIST SYSTEM RESERVOIR IS BELOW LIMITS. REMOVED AND REPLACED THE RESERVOIR IAW AMM 52-11-22. OPERTIONAL CHECKED GOOD.SDR AALA201701139007Bottle · low pressureCIDS CAUTION ON FORWARD FLIGHT ATTENDANT PANEL. R2 DOOR ASSIST BOTTLE LOW PRESSURE. SERVICED DOOR ASSIST BOTTLE PER AMM 52-22-00.
Back to JASC 5240