Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2016091101588Bottle · low pressureR3 DOOR ASSIST BOTTLE EMPTY. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00.SDR SWIA201642668Plate · corrodedRIGHT SERVICE DOOR SILL PROTECTOR PLATE HAS CORROSION ON THE TOP INSIDE OF PLATE. REPLACED THE PLATE IAW SRM.SDR UHLA201609100446Gusset · gougedMAJOR REPAIR - GOUGE ON FWD SERVICE DOOR INTERIOR SKIN STRUCTURE CENTER GUSSET, AREA COVERED BY SLIDE. R&R CENTER GUSSET RT FWD SERVICE DOOR REF SRM 51-41-01 AND 51-43-05.SDR SWAA2016091355744Casting · crackedR1 DOOR CRACKED IN CASTING BELOW THE BOX ASSEMBLY HOUSING AT THE FORWARD INBOARD ATTACH BOLT. R & R R1 DOOR IAW MM.SDR SWAA2016090955641Door · crackedR1 DOOR UPPER AND LOWER DOOR HANDLE MECHANISM MOUNTING MACHINED BEAMS CRACKED AT THE UPPER AND LOWER FORWARD INBD FASTENERS. R & R DOOR IAW AMM.SDR AALA20160908002Cylinder · low pressureR4 DOOR CYLINDER ACCUMULATOR PRESSURE BELOW ALLOWABLE LIMITS. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR SCNA20160904111Bracket · crackedR2 DOOR AFT SWEEPER SEAL BRACKET IS CRACKED. REMOVED AND REPLACED SEAL BRACKET.SDR A6WA201644281Unknown · malfunctionedSERVICE DOOR WILL NOT OPEN FROM OUTSIDE.SDR DALA2016102607677Angle · corrodedCORROSION ON ANGLE, AFT SERVICE DOOR, LEFT LOWER CORNER OF DOOR. REPLACED STOP ANGLES PER DWG 9915565.SDR DALA2016082606220Handle · obstructedR3 DOOR KNUCKLE BUSTER DOES NOT COME OUT WHEN DOOR IS ARMED. CYCLED DOOR AND FOUND PLACARD ON TOP OF "KNOCKER" TO BE HANGING UP KNOCKER. ADJUSTED GAP & CK'S OK. (8887280)SDR ASOA2016082415311Door · out of adjustSERVICE DOOR WILL NOT OPEN PROPERLY. SECURED THE SERVICE DOOR PROPERLY FOR SECURE FIT IAW AMM 52-41-00. OPS CHECKED GOOD.SDR GTIA2016082301576Bottle · low pressureR3 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED THE R3 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR DALA2016082106131Pan · crackedCRACKED PAN ON BEAM NR 4 AT FWD GALLEY SERVICE DOOR. PAN ON BEAM NR 4 WAS REPAIR IAW SRM 52-03D, FIG 3.SDR DALA2016082106125Beam · crackedCRACKED FWD EDGE ON BEAM NR 1 AT GALLEY SERVICE DOOR. R1 BEAM WAS REPLACED IAW SRM 51-30-1, 51-30-2, 51-30-4 AND 51-30-5.SDR DALA2016082106124Fitting · crackedCRACKED FWD EDGE CLIP OVERBEAM 1 AT FWD SERVICE DOOR (R1). NEW CLIP WAS INSTALLED IAW SRM 51-30-5 AND DWG 9911579, REV 1.SDR AALA201608219004Bottle · low pressureDURING DOOR ARMING, THE FLIGHT ATTENDANT REPORTED THAT THE CIDS PANEL MESSAGE INDICATED CHECK R2 DOOR PRESSURE, AMBER PRESSURE. REPLACED R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-22-14-0401.SDR AALA201608309010Gusset · chafedAIRCRAFT IN BASE MAINTENANCE: FORWARD SERVICE DOOR GUSSET PLATE IS CHAFED AT DOOR BEAM NR 3. REPLACED GUSSET PLATE DWG 170-68200-411 AND SRM 51-40-02,51-41-01 & 51-42-01.SDR AALA201608199007Lever · detachedDISARM LEVER R3 DOOR DETATCHED. THE AIRCRAFT WAS GROUNDED. REPLACED IAW SRM AMM 52-22-22.SDR AALA201608199006Bottle · low pressureR4 DOOR ASSIST BOTTLE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001.SDR DALA2016081405999Beam · crackedFORWARD GALLEY SERVICE DOOR FORWARD END OF BEAM NR 4 CRACKED. REPLACED IAW SRM 51-30-02 AND 51-30-05.SDR AALA201608159010Bottle · low pressureCIDS PANEL FAULT MESSAGE FOR R4 DOOR LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00. CIDS PANEL FAULT MESSAGE CLEARED.SDR AALA201608159008Bottle · low pressureFORWARD FLIGHT ATTENDANT PANEL SHOWS 4R AMBER FOR DOOR PRESSURE. MAINTENANCE SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A. FAULT MESSAGE CLEARED.SDR ASAA2016081217681Roller · damagedR1 DOOR WON'T SHUT. FOUND R1 DOOR AFT FRAME, UPPER AND LOWER LATCH ROLLER RECEIVERS DAMAGED. FOUND R1 DOOR AFT FRAME, CENTERING GUIDE AND CENTERING GUIDE ROLLER DAMAGED. ACFT GROUNDED. REMOVED AND REPLACED R1 DOOR FRAME AFT UPPER AND LOWER LATCH ROLLER RECSDR AALA201608309018Gusset · chafedAIRCRAFT IN BASE MANITNENACE, AFT SERVICE DOOR, UPPER FORWARD FRAME GUSSET HAS CHAFE DAMAGE. REPLACED GUSSET PLATE IAW SRM 51-43-03 AND DWG 170-69500-417.SDR FDEA201608112875Intercostal · crackedNR 3 ACM DOOR 114AR UPPER CENTER STR CRACK. R & R DAMAGE INTERCOSTAL WITH NEW ONE, IAW DWG ACA3820.SDR C77A20160810023Gusset · corrodedAFT SERVICE DOOR INTERIOR SKIN STRUCTURE GUSSET AT THE AFT LOWER CORNER OF DOOR HAS CORROSION. REMOVED CORROSION IAW SRM 51-40-01.SDR IPXA2016082807527Skin · crackedINSPECTION TYPE: 3C, R3 DOOR INNER FRAME SKIN CRACKED AT UPPER AFT CORNER CRACKED. REPAIRED IAW EA 011-5310-01-A6388 REV. IR AND EO MD11-5310-61688-A. MAJORSDR A6WA201644186Handle · obstructedSERVICE DOOR OUTER HANDLE IS DIFFICULT TO POP OUT. DOOR OPENS NORMAL WHEN HANDLE IS OUT. FOUND EXCESSIVE PRIMER ON OUTER DOOR HANDLE TARGET. REMOVED EXCESS PRIMER AND DOOR HANDLE OPERATES SMOOTHLY, REF AMM 52-40-00.SDR A6WA201644181Handle · dirtyGALLEY SERVICE DOOR WILL NOT OPEN FROM OUTSIDE, OPENS NORMALLY FROM INSIDE. CLEANED AND LUBED SERVICE DOOR OUTER HANDLE AND R & R OUTER HANDLE SPRING IAW AMM 52-41-03. OPS CHECK GOOD.SDR FDEA201608042815Gate · corrodedMAIN DECK FWD RT SERVICE DOOR LOWER GATE IS CORRODED ACROSS LOWER SURFACE. REMOVED AND REPLACED THE GATE IAW-SRM-52-11-38-4.SDR FDEA201608042812Gate · gougedR4 DOOR HAS GOUGES ON MATING AREA AS MARKS. REMOVED AND REPLACED R4 DOOR LWR GATE ASSY IAW AMM-52-11-38-4, ADJUSTED THE DOOR IAW AMM-52-11-00-5.SDR A6WA201644185Handle · dirtySERVICE DOOR HANDLE WILL NOT OPEN FROM OUTSIDE. CLEANED AND LUBRICATED SERVICE DOOR OUTER HANDLE AS REQUIRED. OPS CHECK GOOD AT THIS TIME.SDR A6WA201644176Door Seal · lack of lubeUNABLE TO OPEN SERVICE DOOR FROM EXTERIOR. LUBRICATED SERVICE DOOR SEAL, HANDLE, AS REQUIRED. OPS CHECK NORMAL. DOOR OPENS FROM OUTSIDE, ACFT OK FOR SERVICE.SDR VNAA2016080200002Door Seal · damagedSERVICE DOOR SQUEALED AFTER TAKEOFF. CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED, FERRIED ACFT TO NEAREST MAINTENANCE FACILITY. MAINTENANCE INSPECTED AND REPAIRED THE SERVICE DOOR SEAL. OPS CHECK GOOD. CLEARED FERRY AND CW O/SDR AALA201608039001Spring · bindingR1 DOOR COVER OFF AND SLIDE WOULD NOT DISARM. AIRCRAFT GROUNDED. MAINTENANCE FOUND THE AFT LEAF SPRING BINDING, STRAGHTENED SPRING AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 25-66-01. MAINTENANCE INSTALLED SLIDE COVER.SDR AALA201608029001Bottle · low pressureCIDS PANEL SHOWS R2 DOOR PRESSURE NEEDS TO BE CHECKED. SERVICED R2 DOOR ASSSIT BOTTLE IAW AMM 25-10-00.SDR AALA201608019011Cover · looseR4 DOOR SLIDE ARMING MECHANISM BINDING BETWEEN ARMED & UNARMED. PARTS AT FLOOR ARE MISALIGNED. MAINTENANCE FOUND THE ESCAPE SLIDE COVER LOOSE, INSTALLED THE ESCAPE SLIDE COVER IAW AMM 52-11-02-904 AND ACCOMPLISHED A SATISFACTORY OPS CHECK.SDR SWIA201642425Door · delaminatedRT FWD UPPER EQUIPMENT COMPARTMENT DOOR DELAMINATING ON FORWARD EDGE. REPAIRED RT FWD UPPER EQUIPMENT COMPARTMENT IAW SRM AND STS EA.SDR DALA2016080105741Door · obstructedR3 DOOR WILL NOT ARM OR OPEN. FOUND BLANKET TO BE OBSTRUCTING DOOR. REMOVED BLANKET AND OPS CHECKED NORMAL.SDR AALA201607299048Bottle · low pressureCIDS PANEL CAUTION, R1 DOOR PRESSURE MESSAGE, SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001A.SDR ASOA2016080115153Door · bindingCANNOT OPEN SERVICE DOOR FROM OUTSIDE. OPS CHECKED SERVICE DOOR IAW AMM 52-40-00. NO DEFECTS NOTED.SDR AALA20160726004Bottle · low pressureR3 DOOR EMERGENCY ACTUATOR PRESSURE IS LOW. SERVICED ACTUATOR IAW AMM 52-22-00.SDR AALA20160726003Bottle · low pressureL3 DOOR EMERGENCY ACTUATOR PRESSURE IS LOW. SERVICED ACTUATOR IAW AMM 52-22-00.SDR N6WA2016072601Door · out of adjustSERVICE DOOR WILL NOT OPEN. ADJUSTED DOOR IAW AMM 52-49-01. OPS CHECKED GOOD.SDR AALA201607259001Bottle · low pressureAFTER DEPARTING THE GATE, FLIGHT ATTENDANT REPORTED THE R2 DOOR SLIDE PRESSURE LOW FAULT MESSAGE. AIRCRAFT GROUNDED. MAINTENANCE SERVICED R2 DOOR DAMPER IAW AMM 52-22-00-614-002-A AND ACCOMPLISHED A SATSIFACTORY OPERATIONAL CHECK.SDR IPXA2016072506329Bottle · low pressurePRIOR DEP FOUND R1 DOOR PRESSURE BELOW GREEN BAND. TRANSFERRED IAW MEL 52-10-3-2. R1 DOOR INOPERATIVE EMERGENCY ASSIST BOTTLE IAW MCC REQUEST. SERVICE R1 DOOR ASSIST BOTTLE, PN MM 12-25-04-600-801.SDR IPXA2016072306194Skin · dentedTWO DENTS ALONG UPPER EDGE OF R3 DOOR PLUG CENTERED AT BS 1285. FWD DENT MEASERES 2.0"X.40"X.105" DEEP. OK FOR CONTINUED SERVICE PER VTSAA EA011-5210-01-A6365 REV IR AND EO MD11-5210-61812-A.SDR A6WA201644139Door Seal · pinchedSERVICE DOOR IS DIFFICULT TO OPEN FROM OUTSIDE (POPS OUT HARD TO TURN). INSPECTED SERVICE DOOR AND FOUND SEAL PINCHED AGAINST DOOR FRAME AFT TOP POSITION, CAUSING SEAL TO RIP.SDR A6WA201644112Unknown · malfunctionedSERVICE DOOR WILL NOT OPEN FROM OUTSIDE.SDR AALA20160719001Battery · inoperativeTHE WIRELESS CONTROL UNIT BATTERY AT R3 DOOR FAILED OPS CHECK. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED BATTERY IAW AND ACCOMPLISHED SUCCESSFUL OPS CHECK IAW AMM 33-51-07.
Back to JASC 5240