JASC 5246
Service difficulty reports · 694
Reports filed under 5246 · Fluid Service Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5246' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026100505506Door · missingTOILET SERVICE DOOR MISSING ON ARRIVAL. DEFERRED PER CDL 52-40-08, (LP 9028123 - AIRCRAFT WAS GROUNDED)SDR R61A2026092700287Door · corrodedWHILE ACFT WAS IN FOR HVY CK, FOUND CF3 WASTE SERVICE PANEL CORRODED AT MULTIPLE LOCATIONS. MX REPLACED WASTE SERVICE PANEL IAW AMM 53-03-60-440-801, SUBTASK 53-03-60-440-002-A.SDR R61A2026092700286Door · corrodedWHILE ACFT WAS IN FOR HVY CK, FOUND CF3 WATER SERVICE PANEL CORRODED AND GOUGED AT MULTIPLE LOCATIONS. MX REPLACED WATER DERVICE PANEL IAW AMM SUBTASK 20-10-01-910-001-A, TABLE 206.SDR DALA2026093005432Pad · corrodedLAVATORY WASTE BOX ACCESS DOOR LATCH (WEAR PADS) HAVE CORROSION. LOCATED ON THE AFT SIDE OF THE WASTE BOX CUT OUT. REMOVED AND REPLACED WASTE BOX DOOR LATCH P ADS PER ASRP 51-42-06 (LP# 1833042; AIRCRAFT WAS GROUNDED)SDR DALA2026093005431Spring · corrodedLAVATORY WASTE BOX ACCESS DOOR HINGE SPRINGS HAVE CORROSION. REMOVED AND REPLACED SPRINGS REF A220 AMP 52-47-06.SDR DALA2026093005430Door · corrodedLAVATORY WASTE BOX ACCESS DOOR HAS TWO LARGE AREAS OF CORROSION. REMOVED AND REPLACED WASTE SERVICE DOOR REF AMP 52-47-06. (LP# 1833038; AIRCRAFT WAS GROUNDED)SDR CALA2026100520123Door · missingPDA 2 FOUND CENTER TANK SUMP DOOR MISSING FROM AIRCRAFT AFTER ARRIVAL. COMPLETED PART 1 INTERIM REPAIR REF EC/RA #5249-01306 INTERIM REPAIR MADE TO CENTER FUEL TANK SUMP DRAIN ACCESS DOOR PER ECRA 5249-01306 PART 1. REMOVED DOOR LATCH ASSY AND BROKEN LOCKINGSDR MASA20261001225Door · corrodedDURING HEAVY CHECK, CFLLL, INSPECTIONS OF AFT EXTERNAL SKIN, CORRODED WASTE ACCESS DOOR BETWEEN FR 88 & 89, STR 25R, EXTERNAL, R & R WITH NEW, IAW AMM 20-10-01. TABLE 202. NRG 4502700-8000-004, REV 103.SDR CALA2026090719254Skin · crackedEXTERNAL POWER RECEPTACLE (112A) MISSING SECTION AT INNER DOUBLER INITIAL RUBBING BLOCK. REPAIR ACCOMPLISHED IN ACCORDANCE WITH SRM 53-10-15-2R-4 REPAIR 4, PAGE 1-13, FIG 201-204 . C/W FOR EXT PWR RECEPTACLE DOOR REPAIR DOUBLER FABRICATED AND INSTALLED REPAISDR VNAA2026083143Hinge Arm · corrodedAFT LAVATORY SERVICE DOOR 196ER OTBD HINGE ARM CORRODED AND OTBD & INBD HINGE BRACKET ASSEMBIES & ATTACHING HARDWARE ARE CORRODED. INSTALLED A NEW LWR SERVICE ARM AND HARDWARE IAW SRM 52-45-01-000-801-A01 AND AMM 20-51-00-400-801-A01.SDR SWAA2026092549928Door · corrodedTOILET SERVICE DOOR, EXTERNAL SIDE WAS CORRODED. REMOVED AND REPLACED THE LAV SERVICE DOOR IAW AMM 52-49-07-400-801. BONDED AND OPS CHECKED GOOD.SDR SWAA2026092533629Door · corrodedWATER SERVICE DOOR, EXTERNAL SIDE WAS CORRODED. IAW EA 26-152-02445 THE DAMAGE IS ACCEPTABLE AS A CONTINUE-IN-SERVICE CONDITION WITHOUT REPETITIVE INSPECTIONS AND NO TERMINATING ACTION REQUIREMENTS.SDR BAGA2026083100009Door · corrodedHVY CHECK SUBMISSION - REAR FUSELAGE WASTE DOOR 146 BR FOUND CORROSION. REAR WASTE DOOR REPLACED.SDR VNAA202608200001Door · crackedDOOR WASTE ASSEMBLY WAS REPAIRED PER EA NO: 2542-2026-0913 REV. -SDR KY7A20260722001Door · inflt separationFLIGHT CREW REPORTED SERVICING DOOR MISSING DURING POST FLIGHT INSPECTION. UPON INVESTIGATION, IT WAS DISCOVERED THAT APU OIL WAS SERVICED PRIOR TO THE FLIGHT. MECHANIC CONFIRMED THAT THE DOOR WAS LATCHED AND SECURE PRIOR TO FLIGHT. INVESTIGATION REVEALED THATSDR MASA20260807207Door · corrodedDURING HEAVY CHECK INSPECTIONS FOR CFIII WASTE SERVICE DOOR INTERNAL, EXTERNAL AND HINGE HAS BEEN REPLACED IAW SRM 51-41-02 YQG.SDR R61A2026072200199Door · corrodedDURING HEAVY CHECK WASTE ACCESS DOOR FOUND WITH CORROSION. REMOVED AND REPLACED WASTE ACCESS DOOR IAW EMB 170/175 AMM 53-03-60SDR SWAA2026071586714Panel · crackedCRACKED HOLD OPEN STRUT ON REFUELING PANEL 621GB. REMOVED AND REPLACED HOLD OPEN STRUT ON REFUELING PANEL 621GB IAW AMM 52-49-21-400-801 STEP 3.E.(6).SDR SWIA2026061577708Angle · gougedFORWARD WATER-WASTE DOOR SURROUND STRUCTURE ANGLE GOUGED FROM DRAIN VALVE ASSY. REMOVED AND INSTALLED NEW FORWARD WATER-WASTE DOOR SURROUND STRUCTURE ANGLE IAW SRM 51-42-06-001-001-A01 AND DWG SH670-32280, REV H COMPLIED WITH TASK CARD 51-900-1002-SKY, LEAK SDR CALA2026061217050Door · missingLAVATORY SERVICE DOOR MISSING AFTER RON IN CID. (FLIGHT UA1923)SDR DALA2026062503775Door · missingTOILET SERVICE DOOR MISSING. INSTALLED NEW LAV SERVICE DOOR PER B737 AMM 52-49. (LOG 8051507 - AIRCRAFT WAS GROUNDED).SDR F3LA202605260420Door · inflt separationLAV SERVICE DOOR MISSING. INBOUND FLIGHT NUMBER 3022. FOUND DURING WALKAROUND INSPECTION. AC WAS NOT GROUNDED. PLACED ON CDL 52-01B. AC WAS OK FOR SERVICE.SDR 2026FA0000403Access Door · missingCREW RECEIVED AN ADVISORY "SERVICE DOOR" CAS MESSAGE IN FLIGHT AND CONTINUED PER AFM DIRECTION. EXTERNAL LAVATORY ACCESS PANEL DISCOVERED MISSING ON POST FLIGHT INSPECTION.SDR R61A2026060100146Door · corrodedDURING HEAVY CHECK REAR FUSELAGE WASTE ACCESS DOOR FOUND WITH CORROSION. REAR FUSELAGE WASTE DOOR HAS BEEN REPLACED IAW AMM 20-10-01-910-801-A00SDR SWAA2026052092184Skin · corrodedCORROSION ON THE INTERNAL SKIN, TOILET SERVICE DOOR 145AL PERFORMED PERMANENT REPAIR LOCATED ON EXTERNAL SKIN TOILET SERVICE DOOR 145AL AT LOWER FUSELAGE IAW SRM 52-40-01-2R-8, REPAIR 8.SDR MASA20260420077Door · corrodedDURING HEAVY CHECK INSPECTIONS ON CFIII, CORROSION FOUND ON WASTE ACCESS DOOR. WASTE ACCESS DOOR REMOVED AND REPLACED IAW AMM 53-03-60-040-801-A AND AMM 53-03-60-440-801-A REV 105 DATE JUNE 27/2025 AAR YQG NRC4502583-8000-0002SDR CALA2026041315305Door · corrodedCORROSION AT WASTE SERVICE DOOR BONDING WIRE ATTACHMENT AT DOOR SIDE. REMOVED WASTE SERVICE DOOR IAW AMM 52-49-07-000-801, INSTALLED HINGES AND LATCH AT NEW WASTE SERVICE DOOR IAW SRM 51-40-02-0G-0, INSTALLED NEW WASTE SERVICE DOOR IAW AMM 52-49-07-400-801 SDR MASA20260318006Door · corrodedWASTE SERVICE DOOR FOUND CORRODED. REPLACED THE WASTE SERVICE DOOR IAW AMM 53-03.60, AMM 53-03-60-040-801-A, AMM 53-03-06-440-801-A.SDR SWAA2026031067085Doubler · corrodedLAV SERVICE DOOR HAS CORROSION ON EXTERIOR SURFACE ON PREVIOUS REPAIR DOUBLER. REMOVED AND REPLACED LAV SERVICE DOOR IAW AMM 52-49-07-000-801; AMM 52-49-07-400-801. BOND CHECK GOOD. BONDING METER: ATS312 11/2026. OPS CHECK GOOD.SDR CALA2026020413544Access Door · missingFOUND WASTE SERVICE ACCESS PANEL COMPLETELY MISSING. APPLIED CDL 52D ON WASTE SERVICE PANEL. CDL 52D SDR REQUIRED INSPECTED WASTE SVC PNL AREA, NO FURTHER DAMAGE FOUND. APPLIED CDL 52D ON WASTE SVC PNL. INSTALLED PLACARD. C/W DDP INSTALLED NEW WASTE TANK SERSDR VNAA20260304020Door · missingFORWARD LAVATORY SERVICE DOOR MISSING. FORWARD LAV SERVICE DOOR INSTALLED IAW SRM 51-42-06-001-001-A01, AND AMM 52-45-17-400-801,CONFIG A02.SDR SWAA2026021262178Door · corrodedCORRODED WASTE SERVICE DOOR 145AL. PERFORMED A PERMANENT REPAIR ON THE WASTE SERVICE DOOR IAW SRM 52-40-01-2R-8, REPAIR 8.SDR REXA2026011500004Beam · crackedDURING MAINTENANCE TO LT HYDRAULIC BAY SKIN, CRACKED LT NLG DOOR BEAM AT LBL 13.40. REPLACED BEAM PER APPLICABLE SRM STANDARD PRACTICES AND DRAWINGS, BEAM IS FCBS & WAS DOCUMENTED AS A MAJOR REPAIR.SDR CALA2026010812802Door · missingMIGRATED SHIM (P/N) 311A2103-4) AT RIGHT PYLON THRUST REVERSER STRUT FAIRING. PERFORM AN INSPECTION OF THE INBOARD SHIM AT THE RIGHT PYLON THRUST REVERSER STRUT FAIRING INSTALLATION PER PART 2 OF ECRA 5450-0302. 9 PERFORM AN INSPECTION OF THE INBOARD SHIM ATSDR CALA2026010812798Bracket · gougedPOTABLE WATER SERVICE PANEL, HAS 2EA LATCH BRACKETS WITH GOUGES. REPAIRED POTABLE WATER SERVICE PANEL LATCH BRACKETS PER EC/RA# 5 360-02082. REF NRC 139021. INSPECTION APPROVEDSDR CALA2026010412650Door · detachedLAVATORY SERVICE DOOR MISSING UPON ARRIVAL TO AUS. REPLACED THE LAVATORY SERVICE DOOR PANEL IAW AMM 52-49-07.SDR CALA2025122412419Door · missingOPS REPORTED ON ARRIVAL TO LIR EXTERIOR LAV SERVICE DOOR MISSING. MISSING LAV SERVICE DOOR ASSY ON ARRIVAL TO LIR. SERVICE DOOR PLACED ON CDL 52D AND PDA CONDITIONAL INSPECTION COMPLETED REF AMM TASK 05-51-59-200-801 SDR SELECTED AS REQUIRED PER GMM 02-30-95.SDR SWIA2025121075164Angle · corrodedCORROSION PRESENT ON IMPACT ANGLE AT FWD WASTE WATER SERVICE DOOR INSIDE STRUCTURE BETWEEN FS379 - FS394 STR 23R (C-CHECK RO 02/01/2026)REMOVED AND INSTALLED NEW REPLACEMENT IMPACT ANGLE AT FWD WASTE WATER SERVICE DOOR INSIDE STRUCTURE BETWEEN FS379 - FS394 SSDR REXA2026052700753Angle · corrodedCORROSION AT FWD WASTE SERVICE DOOR INTERNAL STRUCTURE, INCLUDING IMPACT ANGLE, FWD FRAME, AFT FRAME, UPPER & LOWER MEMBRANE.RMENT DOOR. CORROSION AT FWD WASTE SERVICE DOOR INTERNAL STRUCTURE, INCLUDING IMPACT ANGLE, FWD FRAME, AFT FRAME, UPPER & LOWER MEMBRANSDR DALA2026020900941Door · corrodedER/A 603892-14, REV B, LOWER AFT FUSELAGE, FR 75-76, WASTE SERVICE COMPART & DOOR CORRODED. REPAIR REQUIRES FOLLOW-ON ACTION.ACCOMPLISH 603892-14 REV B, SECTION II REPETITIVE INSPECTION WITHIN EVERY 1,000 FLIGHT HOURS FROM 14,907 TOTAL FH UNTIL SECTION ISDR CALA2025120311727Service Panel · missingRAMP REPORTS LAV SERVICE PANEL IS MISSING. INSPECTED TAIL SECTION AFT OF CUTOUT AND STAB AREA. NO FURTHER DAMAGE NOTED. COMPLETED INSTALLATION WASTE TANK SERVICE PANEL REF AMM 52-49-07.SDR REXA2026052800808Hinge · damagedMANUFACTURE HINGE PN:CC670-39109-1 OF AFT LAVATORY WASTE SERVICE ACCESS PANEL 196ER NEW BRACKET HINGE P/N: CC670-39109-1 WAS FABRICATED PER EA CRJ952-20941 REV: IR.SDR DALA2025111708383Door · corrodedSHIP 5657 MID LAV SERVICE DOOR 121AL HAS CORROSION ON INTERIOR SIDE, BOTTOM EDGE OF PANEL. CORRECTIVE ACTION: BLENDED CORROSION ON RH LAV ACCESS DOOR 121AL, PANEL OUT OF LIMITS PER B757-200 SRM 52-40-01 FIG 101 DETAIL II. REPAIRED DOOR PER PRI 630026-14 REV 2 SDR R61A2025121700529Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND WASTE SERVICE PANEL CORRODED AT MULTIPLE LOCATIONS. WASTE SERVICE PANEL HAS BEEN REPLACED IAW EMB 170 AMM 20-10-01-910-801-400.SDR IPXA2025111955197Door · corrodedLAVATORY SERVICING PANEL ACCESS DOOR OPEN / CLOSE LATCH FROM CTR EXTERNAL FOUND DAMAGED ( UN SERVICEABLE ) LAVATORY SERVICE DOOR REMOVED IAW A300-600 SRM 51-40-21.FABRICATED, LOCATED AND DRILLED NEW REPAIR PARTS (DOUBLER AND SHIM) IAW A300-600 SRM 52-42-11/FISDR SWAA2025121030762Skin · corrodedCORROSION ON INTERNAL SKIN TOILET SERVICE DOOR 145AL, LOWER FUSELAGE. PERFORMED REPAIR ON TOILET SERVICE DOOR 145AL AT LOWER FUSELAGE IAW SRM 52-40-01-2R-8, REPAIR 8, FIGURE 202.SDR CALA2025110210805Service Door · missingLAVATORY SERVICE DOOR MISSING. REPLACED LAVATORY SERVICE DOOR IAW AMM 52-42-11-400-001-A AND ECRA 52-42-01073. OPS CHECK OF LIMIT SWITCH GOOD.SDR CALA2025103110790Service Door · missingLEFT LAVATORY SERVICE DOOR MISSING, DEFERRED REF LOGPAGE CDL 6683578.SDR DXTA2025103005456Service Door · openDURING CLIMB OUT THE WHITE EXTERNAL DOOR OPEN CAS MESSAGE ILLUMINATED. ON THE POST FLIGHT WE DISCOVERED THE LAVATORY SERVICE DOOR WAS MISSINGSDR IPXA2025120998823Access Door · corrodedCORROSION AT LOWER HINGE OF LAV DUMP ACCESS DOOR. AIRFRAME SIDE. INSTALLED 1EA FWD TOILET SERVICE DOOR AND (1EA) LOWER HINGE ASSY FROM FORWARD TOILET SERVICE PAN IAW AMM 52-49-06-404-012 AND SRM 51-40-02-0G-0
Back to JASC 5246