JASC 5250
Service difficulty reports · 4,106
Reports filed under 5250 · Fixed Inner Doors, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5250' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5250' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202208269051Door · lack of lubeAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR HARD TO OPEN. LUBED FORWARD LAVATORY DOOR PER AMM 25-40-00.SDR AALA202208253124Door Latch · lack of lubeAIRCRAFT WAS GROUNDED: FLIGHT DECK DOOR DIFFICULT TO OPEN/CLOSE. CLEANED AND LUBED LATCH MECHANISM, FLIGHT DECK DOOR FUNCTIONS NORMAL PER AMM 52-50-00SDR AALA202208243200Handle · inoperativeAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR STICKS. DIFFICULT TO OPEN. INSPECTED AND ADJUSTED FORWARD LAVATORY DOOR HANDLE. OPERATIONS CHECK NORMAL. OPENS AND CLOSES NORMALLY.SDR AALA202208234624Spring · out of positionAIRCRAFT WAS NOT GROUNDED: MID LAVATORY DOOR NOISY AND DIFFICULT TO OPEN/CLOSE. RE-POSITIONED LAVATORY DOOR SPRING AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202208242709None · inoperativeAIRCRAFT WAS NOT GROUNDED: 2F1L LAVATORY LOCK GETTING STUCK IN LOCKED POSITION (PAX GETTING TRAPPED). REPLACED LAVATORY 2F-1L DOOR ASSEMBLY IN ACCORDANCE WITH AMM 25-41-10.SDR AALA202208233766Door · inoperativeAIRCRAFT WAS NOT GROUNDED: LAVATORY DOOR DIFFICULT TO OPEN OR CLOSE. PERFORMED ADJUSTMENT AND TEST AT LAVATORY 5R DOOR IN ACCORDANCE WITH CMM 25-45-77.SDR AALA202208235971Door · out of positionAIRCRAFT WAS NOT GROUNDED: LAVATORY E DOOR STUCK. PUT LAVATORY E DOOR BACK ON TRACK.SDR AALA202208230309Door · out of adjustAIRCRAFT WAS NOT GROUNDED: RIGHT HAND AFT LAVATORY AIRCRAFT DOOR JAMMED. ADJUSTED DOOR PER AMM 52-50-00.SDR AALA202208188282Door · out of positionAIRCRAFT WAS NOT GROUNDED: LAVATORY DOOR LATCH DIFFICULT TO OPERATE. AFT,LEFT. PUT AFT LEFT LAVATORY DOOR BACK IN TRACK AS REQUIRED. OPERATIONS CHECK GOOD.SDR AALA202208189678None · looseAIRCRAFT WAS NOT GROUNDED: THE 2L LAVORATORY DOOR HAS LOOSE TRIM THAT IS INTERFERING WITH THE LATCHING MECHANISM CAUSING THE DOOR TO GET STUCK CLOSED. RESECURED LAVORATORY 2L DOOR TRIM RUBBER OPERATIONS NORMAL REFERENCE 25-00-00.SDR AALA202208187091Screw · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR WILL NOT OPEN IN FLIGHT FROM THE INSIDE. LATCH OPERATES NORMALLY. INSPECTED FLIGHT DECK DOOR AND FOUND DOOR JAMB SCREWS LOOSE, SECURED AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-51-00.SDR AALA202208224912Screw · looseAIRCRAFT WAS NOT GROUNDED: AFT RIGHT LAVATORY DOOR STICKS AT BOTTOM WHEN OPENING OR CLOSING. **SUPPLEMENTAL REPORT FOR AALA202208174912: RESECURED TRIM SCREWS. OPERATIONAL CHECK NORMAL.** (CLOSED)SDR AALA202208172220Door Latch · inoperativeAIRCRAFT WAS GROUNDED: FLIGHT DECK DOOR WOULD NOT OPEN FROM INSIDE THE FLIGHT DECK IN FLIGHT. OPENED AT THE GATE BY MOVING FLIGHT DECK DOOR SWITCH TO UNLOCK POSITION. REPLACED FLIGHT DECK DOOR LATCH MECHANISM PER AMM 52-51-21. A SATISFACTORY OPERATIONAL CHECK SDR AALA202208178263Door Latch · inoperativeAIRCRAFT WAS GROUNDED: FLIGHT DECK DOOR LOCKED FROM THE INSIDE, PILOTS CANNOT GET OUT. HAD TO CRAWL THROUGH DEPRESS DOOR MAINTENANCE REPLACED FLIGHT DECK DOOR LATCH MECHANISM PER AMM 52-51-21. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202208174912None · noneAIRCRAFT WAS NOT GROUNDED: AFT RIGHT LAVATORY DOOR STICKS AT BOTTOM WHEN OPENING OR CLOSING. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202209152090Door Seal · unserviceableAIRCRAFT WAS NOT GROUNDED: OVERHEAD FLIGHT ATTENDANT REST DOOR DIFFICULT TO OPEN AND CLOSE. **SUPPLEMENTAL REPORT FOR AALA202208162090: REPLACED DOOR SEAL PER SOPM 20-50-24..** (CLOSED)SDR AALA202208162090None · noneAIRCRAFT WAS NOT GROUNDED: OVERHEAD FLIGHT ATTENDANT REST DOOR DIFFICULT TO OPEN AND CLOSE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202208152048Door Latch · sticksAIRCRAFT WAS NOT GROUNDED: 1ST CLASS LAVATORY DOOR STICKS CLOSED. LUBED LAVATORY DOOR LATCH AS REQUIRED.SDR AALA202208156586Door · stickingAIRCRAFT WAS NOT GROUNDED: FIRST CLASS LAVATORY DOOR HARD TO OPEN/CLOSE. MAINTENANCE LUBRICATED FIRST CLASS LAVATORY DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-45-19.SDR AALA202208156124Spring · lack of lubeAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY DOOR SPRING NOT WORKING DOOR DIFFICULT TO OPEN AND CLOSE. MAINTENANCE LUBRICATED LEFT LAVATORY DOOR SPRING AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202208157695Lock · out of adjustAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT SAYS PASSENGERS LOCKING THEMSELVES IN AFT RIGHT LAVATORY DUE TO DOOR LOCK STICKING. ADJUSTED LAVATORY DOOR LOCK PER AMM 52-50-00.SDR AALA202208150774Striker · bindingAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR DIFFICULT TO OPEN AND CLOSE DUE TO LOCK BINDING. MAINTENANCE LUBRICATED FLIGHT DECK DOOR LOCK STRIKERS AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202208153856Door Latch · unsecureAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR IS DIFFICULT TO OPEN AND CLOSE. MAINTENANCE SECURED LAVATORY DOOR LATCH AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202208122993None · inoperativeAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVORATORY DOOR LOCK DOES NOT LOCK PROPERLY. PASSENGER LOCKED IN LAVORATORY DUE TO INOPERABLE LOCK ON INSIDE OF DOOR. LAVORATORY DOOR LOCK ASSEMBLY OPERATION CHECK NORMAL IN ACCORDANCE WITH CMM25-40-65.SDR AALA202208123742Bolt · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR DIFFICULT TO CLOSE AND OPEN. UPPER PART OF THE DOOR RUBS AGAINST THE FRAME. MAINTENANCE SECURED LOOSE BOLTS ON FLIGHT DECK DOOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-51-00.SDR AALA202208112143None · lack of lubeAIRCRAFT WAS NOT GROUNDED: COCKPIT DOOR HARD TO OPEN. LUBRICATED COCKPIT DOOR HANDLE AND LOCKING MECHANISM. OPERATIONS CHECK NORMAL IN ACCORDANCE WITH AMM 52-51-00.SDR AALA202208116453Door · lack of lubeAIRCRAFT WAS NOT GROUNDED: LAVATORY 4F-1L DOOR IS HARD TO OPEN. LUBED DOOR AT LAVATORY 4F-1L IN ACCORDANCE WITH AMM 25-41-00.SDR AALA202208112231Hinge · lack of lubeAIRCRAFT WAS NOT GROUNDED: LAVATORY D DIFFICULT TO OPEN/CLOSE (ENTRY DOOR). LUBRICATED LAVATORY D DOOR HINGE ASSEMBLY. DOOR OPS CHECKS GOOD IN ACCORDANCE WITH AMM 25-40-14.SDR AALA202208091327Door Latch · out of adjustAIRCRAFT WAS NOT GROUNDED: LAVATORY 2F1L DOOR STUCK CLOSED. HARD TO UNLOCK. ADJUSTED DOOR LATCH. DOOR OPERATIONAL CHECKED OK PER AMM 25-41-01.SDR AALA202208082828Door Seal · not seatedAIRCRAFT WAS NOT GROUNDED: LAVATORY 2L SLIDING DOOR DIFFICULT TO OPEN AND CLOSE. RESEATED DOOR SEAL AT LOWER EDGE OF DOOR FRAME PER AMM 25-41-01. OPERATIONAL CHECK GOOD.SDR AALA202208057163Door Latch · unserviceableAIRCRAFT WAS NOT GROUNDED: MAIN DECK CREW REST DOOR CANNOT OPEN FROM INTERIOR. SECURED DOOR KNOB, OPERATIONAL CHECK NORMAL.SDR AALA202208058214Door Frame · out of adjustAIRCRAFT WAS NOT GROUNDED: LAVATORY 3L DOOR HARD TO OPEN AND CLOSE. ADJUSTED AND SECURED HINGE PER AMM 52-5-00. OPERATIONAL CHECK OK.SDR AALA202208052331Door Frame · warpedAIRCRAFT WAS NOT GROUNDED: LAVATORY 2L DOOR DIFFICULT TO MOVE. ADJUSTED FRAME AND REMOVED OBSTRUCTION FROM DOOR CATCH PER A.M.M 52-50-00. DOOR WORKS NORMALLY.SDR AALA202208087513Door · unserviceableAIRCRAFT WAS NOT GROUNDED: LAVATORY 2F-1L DOOR DOES NOT LOCK, HARD TO OPERATE. REPLACED DOOR PER CMM 25-45-80. WORKS AS INTENDED, NO ISSUES NOTED AT THIS TIME.SDR AALA202208044020None · looseAIRCRAFT WAS NOT GROUNDED: LAVATORY 4L ENTRY DOOR HANDLE WILL NOT OPEN FROM INSIDE. FOUND DOOR HANDLE HARDWARE LOOSE. RESECURED DOOR HANDLE PER JAMCO CMM 25-45-81. OPERATIONAL CHECK GOOD.SDR DALA2022080205306None · noneCOCKPIT DOOR STUCK CLOSED AT CRUISE. ELECTRONIC LOCK WORKED. DOOR SEEMED JAMMED AT UPPER RIGHT CORNER. COULDN'T OPEN THE DOOR UNTIL AFTER LANDING AND DEPRESSURIZING A/C. FOUND DOOR FRAME SCREW IN UPPER RIGHT CORNER BACKED OUT. RE-SECURED SCREW. DOOR OPS NML I/SDR AALA202208019504Door · detachedAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY DOOR INOPERATIVE. RE-ATTACHED LAVATORY DOOR AS REQUIRED.SDR AALA202208014536None · lack of lubeAIRCRAFT WAS NOT GROUNDED: LEFT AFT LAVATORY IS HARD TO UNLOCK. LUBRICATED DOOR LOCK ASSEMBLY. OPERATIONAL CHECK GOOD PER AMM 25-40-00.SDR AALA202208016908Fastener · looseAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY E DOOR DIFFICULT TO OPEN LOCK. SECURED LOOSE FASTENER ON LOCK ASSEMBLY. PERFORMED SATISFACTORY DOOR CHECK OPERATION PER CMM 25-40-59.SDR AALA202208014298Fastener · looseAIRCRAFT WAS NOT GROUNDED: FIRST CLASS LAVATORY DOOR STICKS IN LOWER LEFT CORNER, DIFFICULT TO OPEN / CLOSE IN-FLIGHT. RE-TORQUED LAVATORY DOOR HINGE FASTENERS. GROUND OPERATION OK.SDR AALA202208026120Rail · looseAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY DOOR HARD TO OPEN AND CLOSE. TIGHTENED, CLEANED, AND LUBRICATED DOOR RAILING FOR AFT LAVATORY RIGHT DOOR. OPERATIONAL CHECK GOOD.SDR AALA202208017324Door Latch · out of adjustAIRCRAFT WAS NOT GROUNDED: CABIN CREW BUNK ENTRY DOOR STICKS, DIFFICULT TO OPEN. ADJUSTED DOOR LATCH ASSEMBLY PER AMM 25-29-01-700-801. OPERATIONAL CHECK GOOD.SDR AALA202207288066Door · out of adjustAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR HARD TO OPEN AND CLOSE. ADJUSTED DOOR PER CMM 25-40-61.SDR AALA202207289199Door · out of adjustAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR DIFFICULT TO OPEN AND CLOSE. MAINTENANCE ADJUSTED FLIGHT DECK DOOR PER AMM 52-51-11SDR AALA202207260349Door Latch · lack of lubeAIRCRAFT WAS NOT GROUNDED: FLIGHT DECK DOOR DIFFICULT TO OPEN. CLEANED AND LUBRICATED DOOR LATCH. OPERATIONAL CHECK GOOD PER AMM 52-51-03.SDR AALA202207265600None · faultyAIRCRAFT WAS NOT GROUNDED: LAVATORY 3F-2R BI-FOLD DOOR NOT SLIDING IN TRACK. REPLACED GUIDE (AALA202207255903) AND ROTARY DAMPER (AALA202207265600) PER CMM 25-45-81. DOOR OPERATES NORMAL.SDR AALA202207265903Guide · faultyAIRCRAFT WAS NOT GROUNDED: LAVATORY 3F-2R BI-FOLD DOOR NOT SLIDING IN TRACK. REPLACED GUIDE (AALA202207255903) AND ROTARY DAMPER (AALA202207265600) PER CMM 25-45-81. DOOR OPERATES NORMAL.SDR AALA202207252358None · lack of lubeAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY ENTRY DOOR DIFFICULT TO OPEN / CLOSE. LUBRICATED DOOR.SDR AALA202207254442Hinge · lack of lubeAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR STICKY TO OPEN AND CLOSE. LUBRICATED HINGES PER AMM 25-40-00. ACCOMPLISHED SATISFACTORY FUNCTIONAL CHECK.SDR AALA202207214046Door · noneAIRCRAFT WAS NOT GROUNDED: LAVATORY 2F-1L DOOR VERY DIFFICULT TO OPEN FROM INSIDE. ADJUSTED DOOR PER AMM 25-41-00. OPERATIONAL CHECK GOOD.
Back to JASC 5250