JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2024022900600Door Frame · crackedR/H EMERGENCY EXIT FWD FRAME CRACKED.SDR CALA2024022900599Failsafe · corrodedGENERATING ITEM: 63-5310-1-2503, FLC DOOR CUTOUT LWR SILL F/S 569 FAIL SAFE STRAP HAS CORROSION AT CARGO STOP AFT FASTENER LOCATION, TAG# 8138. LEFAIVE REMOVED AND REPLACED FAIL SAFE STRAP IAW B767 SRM 51-40-02 SECTIONS 4 & 7.SDR EE4Y2024022819560Skin Panel · dentedLOWER CENTER FUSELAGE I, AT FR23, STRINGER 25RH+173MM EXTERNAL SKIN WITH EXISTING TOOL MARK. NOTE: THE FUSELAGE SKIN WAS REPAIRED AS PER EMBRAER ETD2024-190-000066 GUIDELINES AS STATED IN COOPESA ENGINEERING ORDER NO: COO-EO-2024-19125-R00 ( FOR ADDITIONAL DETSDR EE4Y2024022819557Skin Panel · damagedLOWER FUSELAGE AT FR18+105MM, STRINGER 26RH+170MM EXTERNAL SKIN WITH LIGHTNING STRIKE. NOTE: THE FUSELAGE SKIN WAS REPAIRED AS PER EMBRAER ETD2024-190-000450 GUIDELINES AS STATED IN COOPESA ENGINEERING ORDER NO: COO-EO-2024-19140-R00 ( FOR ADDITIONAL DETAILS SSDR REXA2024071600552Post · corrodedLH FS280 LOWER DOOR POST REPAIR IS CORRODED WITH LOOSE FASTENERS. LH FS280 LOWER DOOR POST REPAIR IS CORRODED WITH LOOSE FASTENERS. REMOVED EXISTING REPAIR AT LH LOWER DOOR POST, IAW CRJ-900 SRM 51-42-13-001-001-A01. FABRICATED REPAIR PARTS IAW 53-11-10-201-00SDR SCNA20240425203Pressure Deck · crackedREPAIRED WING CENTER SECTION REAR SPAR VERTICAL PRESSURE DECK WEB UPPER SECTION.SDR JJBA20240322084Beam · corrodedCARGO CUTOUT LOWER BEAM FOUND CORRODED BTW FR 65-68. CARGO CUT-OUT LOWER BEA, BTW FR65-68 BLENDED AND FOUND OUT OF LIMIT. CARGO CUT-OUT LOWER BEAM BTW FR 65-68 REMOVED FOR REPLACEMENT. BTW FR 65-68 ITEM 40-45-50-55-60-65 REMOVED FOR ACCESS. CARGO CUTOUT BTW FRSDR VNAA2024030211101Unknown · vibrationWHILE INFLIGHT, THE ACFT STARTED HAVING VIBRATIONS. CAPTAIN DECLARED AN EMERGENCY WITH ATC & DIVERTED TO CVG WITHOUT FURTHER ISSUES. INSTALLED NEW RT (HYD SYS #2) WISHBONE LOCATED ABOVE RT CENTER ELEVATOR POWER-CONTROL UNIT IAW AMM 27-33-01-400-802. RE-INSTALSDR IXXA2024031101Helicoil · strippedWINDOW FRAME 13L HAS ONE DAMAGED HELI COIL AND OUT OF ROUND HOLESDR JJBA20240304011Crossbeam · corrodedCF2, MIDDLE ALLEY CROSSBEAM ON FLOOR STRUCTURE AT FR29 FOUND CORRODED. AT CF2, MIDDLE ALLEY CROSSBEAM AT FR29, REMOVED FOR INVESTIGATION. AT CF2 MIDDLE ALLEY CROSSBEAM AT FR29 BLENDED OUT OF LIMITS. CF2, MIDDLE ALLEY CROSSBEAM ON FLOOR STRUCTURE AT FR29 INSTALSDR CALA2024030400630Shoe · damagedCREW REPORTED TAIL STRIKE ON DEPARTURE. SFO-SFO FUNCTIONAL FLIGHT. CREW DEBRIEF: PILOT REPORTED TAIL STRIKE ON DEPARTURE FROM SFO TO SFO. THEY HEARD AND FELT STRIKE AS THEY ROTATED AND WERE CALLING FOR GEAR UP. DATA PROVIDED WAS V2 WAS 127, ROTATE 115-122 AND SDR AALA202402283578Structure · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED EMERGENCY EXIT DOOR 833 SEGMENT, BETWEEN FR 40 AND FR 41, BETWEEN BEAMS 1 AND 2. REPLACED SEGMENT PER EO 5210Y228-001.SDR SWIA202404290225Landing · crackedRIGHT TRU BAY ( FORWARD EQUIPMENT COMPARTMENT ) AFT DOOR LATCH CUTOUT HAS POSSIBLE CRACK. (C-CHECK RO 4/26/2024) VERIFIED AND CONFIRMED CRACK ON THE RIGHT-HAND TRU BAY DOOR LANDING. REPLACED RIGHT-HAND TRU DOOR LANDING REF. REO 670-53-11-1935 REV. -- DATE:SDR SWAA2024040156129Pressure Deck · crackedHORIZONTAL PRESSURE DECK WEB STA 663 + 3; CRACKS AT RBL 43 AND RBL 40<[01] NDT HFEC INSPECTED SURFACE PER 737 NDTM PART 6; 51-00-00; PROC 23; CRACKS NOTED AT BS 663 + 3; RBL 43 AND RBL 40; .700' LONG. MARKED ENDS AND DIRECTIONS OF CRACKS.<BR>EQUIP ID IS000680 SDR AALA202402265585Access Door · unsecureAIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: AFTER TAKEOFF AND RAISING THE LANDING GEAR LEVER, THE LANDING GEAR WILL NOT COME UP, AIRCRAFT AIR INTERRUPTED BACK AND LANDED SAFELY AT CLE. FOUND MANUAL LANDING GEAR EXTENSION ACCESS DOOR NOT FUSDR DALA2024022602642Door Frame · corrodedEXFOLIATION CORROSION AT AFT CARGO LWR DOOR JAMB FROM STA Y=954 TO Y=996. SUMMARY OF NRC 00020: CORROSION LEVEL 2. AFT CARGO LWR DOOR JAMB FROM STA Y=954 TO Y=996 WAS REPLACED PER B717 SRM 53-20-15-2R REPAIR 7, 51-41-02-0G, AND 51-41-04-0G. (LP #0218389)SDR DALA2024022602641Beam · crackedCRACK ON BEAM #2 ON STA 197 AT PASSENGER DOOR 1L. SUMMARY OF NRC 00139: BEAM #2 ON STA 197 AT PASSENGER DOOR 1L WAS REPAIRED PER B717-200 SRM 52-10-02-2R PROCEDURE 8 REPAIR 8. (LP #0218077)SDR AWKA202405290005Floor Skin · corrodedRESUBMIT FROM 27-MAY-24: FOUND CORRODED AREAS OF THE DROPPED AISLE FLOOR AT FS189, FS193, AND BETWEEN FS 223.35 AND FS 240.35. ***ACCOMPLISHED AEROSPACE QUALITY RESEARCH & DEVELOPMENT (AQRD) ENGINEERING REPAIR ORDER ERO-978143 REV. IR "N735XJ · DROP AISLE FUSESDR SWAA2024040155901Access Panel · crackedCRACK ACCESS PANEL 195CR AT UPPER FUSELAGE. REPAIRED ACCESS PANEL 195CR IAW SRM 51-70-04-2R-10 REPAIR 10. REPAIRED ACCESS PANEL 195CR IAW B737-800 SRM 51-70-04-2R-10 REPAIR 10.SDR AALA202403183226Crossbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN AFT CARGO COMPARTMENT FRAME CROSSBEAM AT STA 1874, S43R. REPLACED CROSSBEAM PER SRM 51-40-02-0G.SDR SWIA2024042900223Retainer · bentAFT BAGGAGE BAY DOOR LOWER CENTER SEAL RETAINER BENT IN AT FWD AND AFT STOP FITTINGS (C-CHECK RO 4/26/2024) REMOVED AND REPLACED WITH NEW AFT CARGO DOOR LOWER CENTER SEAL RETAINER REF CRJ700 SRM 51-42-06-001-001-A01 AND DWG CC670-38702, REV -F. LEAK CHECK SDR JJBA20240306033Angle · bentRF1, LH ANGLE POST CARGO DOOR ENTRANCE FLOOR STRUCTURE AT FR66 FOUND BENT. RF1, LH ANGLE POST CARGO DOOR ENTRANCE FLOOR STRUCTURE AT FR66 REMOVED FOR REPLACEMENT. LH ANGLE POST CARGO DOOR ENTRANCE NEW PART HOLES TRANSFERRED. LH ANGLE POST CARGO DOOR ENTRANCE NSDR JJBA20240306032Angle · crackedRF1, LH ANGLE CARGO DOOR ENTRANCE FLOOR STRUCTURE AT FR 66 FOUND CRACKED. RF1, LH ANGLE CARGO DOOR ENTRANCE DOOR STRUCTURE AT FR66 REMOVED FOR REPLACEMENT. LH ANGLE CARGO DOOR ENTRANCE AT FR66, NEW CARGO DOOR ENTRANCE AT FR66, NEW PART HOLES TRANSFERRED. LH CASDR JJBA20240306028Angle · corrodedRF1, CARGO DOOR SURROUND STRUCTURE AFT L-SHAPE AT FR 68 FOUND CORRODED. RF1, CARGO DOOR SURROUND STRUCTURE AFT L-SHAPE AT FR68 FOUND OUT OF LIMITS. RF1, AFT L-SHAPE AT FR68 REPAIR COMPLETED AND INSTALLED.SDR DALA2024022602660Stop Fitting · gouged(LOG 0214805) FWD ENTRY DOOR FUSELAGE FRAME UPPER AFT DOOR STOP GOUGED. REMOVED FWD ENTRY L1 DOOR STOP AND REPLACED WITH NEW IAW BOEING 737-800 SRM 51-40-02.SDR DALA2024022302543Door Frame · damagedSHIP 3408 DAMAGE FOUND ON ARRIVAL AFT CARGO DOOR FRAME AT 41CM/16.14 INCHES UP FROM BOTTOM RIGHT CORNER. STGR41RH. FR59A. CORRECTIVE ACTION: DAMAGE IS 1.4CM/0.55 INCHES LONG, 0.7CM/0.27 INCHES DEPTH AND 0.6CM/0.23 INCHES WIDTH. PERFORMED REWORK IAW A330 SRM 53SDR UIEA2024022100107Door Frame · crackedFND DOOR CUTOUT CRACK AT L5 DOOR RELEASE HANDLE AREA, STA 2240, WL 250.(<P>1) PERFORM JOB IAW WORK SHEET #40078 2) JOB COMPLETED AND CONDITION CHECK NORMAL.</P>)SDR CALA2024031500740Unknown · crackedEA5312-01059 REV C OP 002 (AD 2011-14-02)-STA 1809 RH FWD OUTER CHORD STR 5R TO 6R IEA CRACK FOUND. STA1809 RH FWD OUTER CHORD STR 5R TO STR 6R REPAIRED AS PER ECRA5380-01380 REV - ATTACH FORM 44-0008 ITEM 1 TO ITEM 46 ACCOMPLISHEDSDR AALA202403134421Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN L1 DOOR FRAME LOWER INNER CHORD AT STA 302, LBL 55. REPLACED CHORD PER AARD 51-00-05-1.SDR JJBA20240306034Angle · bentRF1, LH ANGLE POST CARGO DOOR ENTRANCE FLOOR STRUCTURE AT FR67 FOUND BENT. RF1, ANGLE POST CARGO DOOR ENTRANCE FLOOR STRUCTURE AT FR67 REMOVED FOR REPLACEMENT. RF1, LH ANGLE POST CARGO DOOR ENTRANCE AT FR67 NEW PART HOLES TRANSFERRED. RF1, LH ANGLE POST CARGO SDR JJBA20240306031Beam · corrodedRF1, LOWER BEAM OF CARGO DOOR SURROUND STRUCTURE BTW FR 65-68 FOUND CORRODED. RF1, LOWER BEAM OF CARGO DOOR SURROUND STRUCTURE BTW FR 65-68 LH REMOVED FOR ACCESS. BEAM SURROUND STRUCTURE BTW FR65-68 LH FOUND OUT OF LIMITS. RF1, LOWER BEAM DOOR SURRPUNT BTW FR SDR DALA2024022502574Flange · crackedSHIP 3267 DISC: A CRACK FOUND ON LHS FR68 HORIZONTAL FLANGE ALONG THE FILLET RADIUS AT STR 22 LHS. C/A: PER SECTION DTE OF 615754-14AD THE REPAIR OF SECTION I IS LIMITED TO 32,000 FC FROM SECTION I. ADDIITIONAL ENG'G AUTHORIZATION REQUIRED FOR SERVICE BEYOND TSDR DALA2024022502573Flange · crackedSHIP 3267 DISC: A CRACK WAS FOUND ON LHS FR68 HORIZONTAL FLANGE ALONG THE FILLET RADIUS AT STR 22 LHS. C/A: PER SECTION II OF 615754-14AD, ACCOMPLISH SECTION II INSPECTION OF THE REPAIR PART HORIZONTAL FLANGE AND INNER CAP FILLET RADIUS WITHIN EVERY 19,700 FC SDR DALA2024022502572Flange · crackedSHIP 3267 DISC: A CRACK FOUND ON RHS FR68 HORIZONTAL FLANGE ALONG THE FILLET RADIUS AT STR 22 RHS. C/A: PER SECTION DTE OF 615763-14AD THE REPAIR OF SECTION I IS LIMITED TO 43,300 FC FROM SECTION I (22FEB24). ADDITIONAL ENG'G AUTHORIZATION REQUIRED FOR SERVICESDR DALA2024022502571Flange · crackedSHIP 3267 DISC: A CRACK WAS FOUND ON RHS FR68 HORIZONTAL FLANGE ALONG THE FILLET RADIUS AT STR 22 RHS. C/A: PER SECTION II OF 615763-14AD, ACCOMPLISH SECTION II INSPECTION OF THE REPAIR PART HORIZONTAL FLANGE AND INNER CAP FILLET RADIUS WITHIN EVERY 19,700 FC SDR CALA2024022300511Window Frame · cracked(EA 5310-04554 REV C) RH #1 WINDOW FRAME CRACKED REF TO PEMCO NR 14861.0022 ACCOMPLISHED EA 5310-04554 REV C OP 004,SDR CALA2024022300510Window Frame · cracked(EA 5310-04554 REV C) LH #1 WINDOW FRAME CRACKED. REF TO PEMCO NR 14861.0021 ACCOMPLISHED EA 5310-04554 REV C 003,SDR KCSA202402221029Door Frame · damagedFWD LWR FASTENER HOLE DAMAGE AT L5 DOOR FRAME STA 2231 STR 16LSDR DALA2024022202463Door Frame · corrodedCORROSION AFT PREVIOUS REPAIR DOUBLER ON FWD CARGO COMPARTMENT DOOR JAMB. SUMMARY OF NRC 00195: CORROSION LEVEL 2. NEW DOUBLER ON FWD CARGO COMPARTMENT DOOR JAMB WAS FABRICATED PER B717 SRM 53-20-15-2R PROCEDURE 6 REPAIR 6 AND REPLACED PER SRM 51-41-02-0G AND SDR WX0A1900010031975Beam · corroded(DISCREPANCY NOTED DURING AIRCRAFT HEAVY MAINTENANCE VISIT) LIGHT CORROSION FOUND ON L1 LOWER SILL BEAM AROUND GIRT BAR FITTING ATTACHMENT HOLES / ON L1 LOWER SILL BEAM AROUND GIRT BAR FITTING ATTACHMENT HOLES, REPAIR PERFORMED AS PER SRM TASK 53-11-14-283-00SDR WX0A1900010031974Beam · corroded(DISCREPANCY NOTED DURING AIRCRAFT HEAVY MAINTENANCE VISIT) LIGHT CORROSION FOUND ON R1 LOWER SILL BEAM AROUND GIRT BAR FITTING ATTACHMENT HOLES / ON R1 LOWER SILL BEAM AROUND GIRT BAR FITTING ATTACHMENT HOLES, REPAIR PERFORMED AS PER SRM TASK 53-11-14-283-005SDR SWAA2024022954834Repair · unknownCUSTOMER REQUEST - ACCOMPLISH HFEC INSPECTION OF PREVIOUS CUTOUT ON FLIGHT DECK FLOOR REPAIR CALLED OUT ON STEP 9 OF EA 1-A53-33179 REV IR<[01] REMOVED AND REINSTALLED COCKPIT FLOOR REPAIR PREVIOUSLY; REMOVED FOR NDT INSPECTION; PER REF SRM 51-40-02-G-0 AND RESDR DALA2024022202512Stanchion · cracked(LOG 0212220) WHILE AT SEA, MTC DISCOVERED DAMAGE CONSISTING OF A CRACK RUNNING HORIZONTALLY ACROSS THE VERTICAL STANCHION (C-D POST) COMMON TO WINDOW FRAME (P/N 141A8811-5) OF THE LH NO. 1 FLIGHT DECK WINDOW. REPAIRED CRACK PER ERA 615982-14.SDR REXA2024102801063Former · crackedR/H AFT OVERWING EMERGENCY EXIT (S/N SB1400) TOP FORMER IS CRACKED AT SWITCH TARGET. REPAIRED RH AFT OVERWING EXIT DOOR IAW CRJ952-16067 REV IR DATED 2/16/24.SDR SWIA202405080220Pressure Deck · corrodedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA56697-690-53-41-214-N689CAMXCODEID50977-PR - THE RHS PRESS FLOOR SILL DECK AND SPLICE PLATE ARE CORRODED AT FS797. REMOVED CORROSION IN REF TO TEMP REO 690-53-41-214 REV A, DTD 02/12/2020. PERFORM PERM REPAIR WITHIN 8SDR AALA202404262270Rail · wornAIRCRAFT IN BASE MAINTENANCE FLIGHT DECK WINDSHIELD LATERAL WINDSHIELD FRAME JUNCTION RAIL HAS ELONGATED HOLE AT FR 4 RIGHT. REPLACED RAIL PER EA 351108.SDR AALA202404260347Fitting · wornAIRCRAFT IN BASE MAINTENANCE FLIGHT DECK WINDSHIELD LATERAL WINDSHIELD FRAME JUNCTION LOWER CORNER FITTING HAS ELONGATED HOLE AT FR 4 RIGHT. REPLACED CORNER FITTING PER EA 351108.SDR AALA202404261217Fitting · wornAIRCRAFT IN BASE MAINTENANCE FLIGHT DECK WINDSHIELD LATERAL WINDSHIELD FRAME JUNCTION UP EER CORNER FITTING HAS ELONGATED HOLE AT FR 4 RIGHT. REPLACED CORNER FITTING PER EA 351108.SDR R61A2024040300153Seal · damagedSMOKE SEAL REMOVED FROM THE AFT AVIONICS BAY WAS DAMAGED. R&R RH SMOKE SEAL.SDR SWIA2024022600175Window Post · crackedDURING REMOVAL OF RH SIDE WINDSHIELD FOUND CRACK ON THE UPPERMOST BARREL NUT OF THE RH WINDOW/WINDSHIELD SIDE POST. (FILED CLOSED)REMOVED AND REPLACED RH SIDE POST. IN REFERENCE TO SRM REF: 53-11-35 / 51-42-21 AND INSTALLATION DWG # CC670-33055 REV F. SEE ATTA
Back to JASC 5310