JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024010200042Unknown · unknownSHIP 3120 CRACK INDICATIONS WERE FOUND AT LH & RH FRONT WINDSHIELD FRAMING. CORRECTIVE ACTION: REPAIRED AREA 1 PER ERA 613423-14AD. (0131083)SDR JR2R20231229597Doubler · corrodedDOUBLER FWD OF R1 DOOR ON FLOOR STRUCTURE CORRODED. REMOVED AND REPLACEDSDR AALA202403082545Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK LEFT HAND LATERAL POST WINDSHIELD FRAME UPPER ATTACHMENT BETWEEN FR 3 AND FR 8. REPLACED WINDSHIELD FRAME PER EA 349770.SDR AALA202403085623Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK RIGHT HAND LATERAL POST WINDSHIELD FRAME UPPER ATTACHMENT BETWEEN FR 3 AND FR 8. REPLACED WINDSHIELD FRAME PER EA 349770.SDR AALA202401105653Door Frame · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT PASSENGER DOOR SURROUND STRUCTURE INNER CHORD FROM BS 967 TO BS 987, LBL 50. REPLACED INNER CHORD PER AARD AARD 51-00-05-01.SDR DALA2023122910700Unknown · unknownSHIP 3120 BENT CROSSBEAM INTERNAL STRUCTURE LOCATED BETWEEN FR27 AND STR38L TO STR41L IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED CROSSBEAM LOCATED BETWEEN FR27 AND STR38L TO STR41L IN FWD CARGO COMPARTMENT AS PER A319 SRM 51-42-11 AND A319 SRM 51-72SDR EE4Y2023122819072Skin Panel · misrepairedFORWARD FUSELAGE, FROM FR04+165MM TO FR05+170MM, BETWEEN STRINGER 23RH+45MM AND STRINGER 25RH+95MM, EXTERNAL SKIN WITH EXISTING REPAIR WITHOUT TRACEABILITY OF MATERIALS. NOTE: THE FUSELAGE SKIN WAS REPAIRED AS PER EMBRAER ETD2023-190-029872 GUIDELINES AS STATESDR ASAA2023122347476Baffle · corrodedAFT PIT R/H BAFFLE STA 747 TO 767 HAS CORROSION. GROUNDED - YES. REMOVED CORROSION FROM BAFFLE PER B737-900ER SRM 53-00-53-1A-2A. ORIG THICKNESS IS .032 PER B737-900ER SRM 53-30-15-0I-1 TABLE 2 REMOVED .009 REMAINING THICKNESS IS .023 AND FOUND TO BE OUT OF LISDR IPXA2024011927958Door Frame · damagedAFT SIDE OF MAIN CARGO DOOR FRAME HAS DAMAGE***SM10/LMX0*** COPY AND PASTED FROM PREVIOUS WORK STEP.<BR>. JAMIE CECIL (TECHNICIAN), 15-JAN-2024 12:42 UTC<BR>INSTALLED SEAL DEPRESSOR IAW SRM 51-40-02.SDR IPXA2023122327958Unknown · unknown*SDR FILED OPEN* AFT SIDE OF MAIN CARGO DOOR FRAME HAS DAMAGE***SM10/LMX0*** FOUND DAMAGE TO BE TO MAIN CARGO LOWER AND UPPER SEAL DEPRESSORS. ACCOMPLISHED INTERIM REPAIR AND DEFERRED PER SREO-8088-REQ001.SDR SWI202402200171Fitting · gougedPASSENGER DOOR SURROUND STRUCTURE AFT LOWER SHOOT BOLT FITTING GOUGED (C-CHECK RO 2/19/2024) REPAIRED PASSENGER DOOR SURROUND STRUCTURE AFT LOWER SHOOT BOLT FITTING BY COMPLYING WITH ALL STEPS OF REO 670-53-21-2352 REV -- DATED 2023-12-29SDR SWI2024021900169Fitting · gougedPASSENGER DOOR SURROUND STRUCTURE FORWARD LOWER SHOOT BOLT FITTING GOUGED (C-CHECK RO 2/19/2024) REPAIRED PASSENGER DOOR SURROUND STRUCTURE FORWARD LOWER SHOOT BOLT FITTING BY COMPLYING WITH ALL STEPS OF REO 670-53-21-2352 REV -- DATED 2023-12-29 COMPLIED SDR R61A2023122100753Beam · corrodedWHILE IN HEAVY CHECK - AFT PAX DOOR LOWER BEAM HAS CORROSION AT GIRT BAR FITTINGS ABD ALONG LOWER SEAL DEPRESSORS. REMOVED AND REPLACED AFT PAX DOOR LOWER THRESHOLD BEAM BETWEEN FRAMES 85-87 REFER SRM 51-40-08. RESTORED SURFACE PROTECTION TO REWORKED AREA REFSDR R61A2023122100751Beam · corrodedWHILE IN HEAVY CHECK - CORROSION ON FORWARD PASSENGER DOOR CUTOUT LOWER BEAM, FR 16-19. REMOVED AND REPLACED FORWARD PASSENGER DOOR CUTOUT LOWER BEAM FR 16-19 REF EMB SRM 51-21-01, EMB SRM 51-40-08.SDR AALA202404160980Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CENTER WING BOX PRESSURE DECK MEMBRANE FASTENER HOLE CRACKED AT FR 36 AND -Y1292 PLUS 3.5 INCHES. REPAIRED PRESSURE DECK MEMBRANE PER EA 350328.SDR AALA202404114773Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CENTER FUSELAGE PRESSURE DECK MEMBRANE HAS 2 CRACKED FASTENER HOLES AT FR 36 AND S8L AT THE +Y1292 BEAM. REPAIRED PRESSURE DECK MEMBRANE PER EA 350328.SDR SWAA2024020534392Support Frame · crackedFWD CABIN WET AREA FUSELAGE SUPPORT FRAME CRACKED @ CUTOUT ABOVE L-1 DOOR FWD STA 312 MKD DOT<[01] ACCOMPLISHED REPAIR FOR EA NO:M-22-153-01244;[02] VERIFIED REPAIR ACCOMPLISHED PER EA NO: M-22-153-01244;[03] VERIFIED REPAIR ACCOMPLISHED PER EA NO: M-22-153-01SDR DALA2023122410540Unknown · unknownCORROSION ON LOWER DOOR JAMB BTW STA:946 TO 994 AT AFT CARGO COMPARTMENT. SUMMARY OF NRC 00033: CORROSION LEVEL 2. LOWER DOOR JAMB BTW STA:946 TO 994 AT AFT CARGO COMPARTMENT WAS REPAIRED PER B717 SRM 53-20-15-2R-7 REPAIR 7. (LP #0120705)SDR DALA2023122210521Unknown · unknownSHIP 3120 CRACK WAS FOUND AT HOLE #26 OF FR20 RH, CROSSBEAM SPLICE ZONE. CORRECTIVE CTION: REPAIRED PER ERA 613605-14AD. (0120581)SDR DALA2023122210516Unknown · unknownSHIP 3120 BENT INTERNAL STRUCTURE CROSS BEAM AT LEVEL OF FRAME 29 AND FROM STRINGER 38RH AND STRINGER 38LH IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED CROSS BEAM AT LEVEL OF FRAME 29 AND FROM STRINGER 38RH AND STRINGER 38LH IN FWD CARGO COMPARTMENT ASDR AALA202403269543Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR STRUCTURE PRESSURE DECK MEMBRANE HAS 6 FASTENER HOLES CRACKED AT FR 36 BETWEEN +Y1294 AND -Y1295. REPAIRED PRESSURE DECK MEMEBRANE PER EA 350303.SDR FDEA202312200244Fitting · corrodedRH RIB 5 FITTING HAS CORROSION. REPAIR PER AIRBUS REPAIR DRAWING R57240425SDR SWAA2024020634237Access Panel · corrodedKEEL BEAM ACCESS PANEL #192F HAS EVEDENCE OF CORROSION ON FWD AND AFT BECON ANTENNA MOUNTING BRACKETS.<[01] REMOVED AND DISCARDED DAMAGED PANEL; RECEVIED NEW SPARE PANEL PN 654A0004-613 AND APPLIED DECORATIVE FINISHING PER REF B737 AMM 51-21-73-370-803. INSTALSDR SWAA2024020534238Panel · corrodedCENTER TANK SUMP DRAIN PNL#192G HAS EDIDENCE OF CORROSION<[01] PANEL ASSY 192F HAS BEEN REPLACED ON FAULT #TTG8Q00QF35H; SUCH PANEL ASSY CONTAIN DOOR PANEL 192G; THUS NO FURTHER ACTION REQUIRED.;[02] VERIFIED STEP 1.SDR SWAA2024013033893Pressure Deck · crackedCRACK IN HORIZONTAL PRESSURE DECK BS 670 WL 202 RBL 41.5. CRACK IS APPROX 1/2 INCH LONG MARKED IN RED.<[01] REPAIRED HORIZONTAL PRESSURE DECK BETWEEN BS 663 TO BS 675 WL 202 RBL 30 TO RBL 60 PER SRM 53-40-51-2R-2 REPAIR 2;[02] ACCOMPLISHED THE APPLICATION OF CSDR CALA2024012200161Stringer · corroded(A3NB-53-4-6179) 86-108 AFT PIT FRAME 53 AFT APPROX 10" CORROSIO N ON STR 40LH.() REMOVED CORROSION L=5.220", W=.850 D=.031" FOUND OUT OF LIMITS I TION IAW SRM 51-75-12/001. W/C:78552 EMP:V940362 STA:STENGBFM AW SRM 53-41-13-283-002, PERFORMED REPAIR CAT.A CUTSDR AALA202312268177Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VERTICAL PRESSURE DECK WEB AT BS 663, FROM LBL 34 TO LBL 35.25. REPAIRED WEB PER SRM 57-10-10-2R-3 ALT 1.SDR YENA2023122101639Unknown · unknownDURING HEAVY MAINTENANCE: AFTER LATCH FITTINGS REMOVAL IN REF WITH NRC 071,CORROSION ON LOWER BEAM IN CUTOUT AT FWD CARGO DOOR; REF TOMX WO # 2404 NR # 00144 CORROSION ON LOWER BEAM IN FWD CARGO DOOR CUTOUT WAS REMOVED PER EMB-190 SRM 51-12-01 AND SRM 51-10-0SDR SWAA2024011633609Tie Clip · crackedCRACK ON TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA 2023-756881<[01] REPLACED TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DRAWING # 141A1110 SHEET 17 REV.-.. SEE INDIVIDUAL SDR YENA2023122101626Unknown · unknownDURING HEAVY MAINTENACE: CRACK INDICATION FOUND IN OPEN INBOARD LOWER HOLE FROM DOOR STOP FITTIING #7, RH FRAME 16; CRACK DIRECTION: 6 O'CLOCK; D1-D2= 0.125 INCH; REF AEROMAN WO 2023 360/1 N/R 2023-692459, PERFORMED REPAIR ON FRAME 16 RH LOCATED INBOARD LOWER SDR YENA2023122101625Unknown · unknownDURING HEAVY MAINTENACE: CRACK INDICATION FOUND IN OPEN UPPER HOLE FROM DOOR STOP FITTING #7; R H FRAME 16; CRACK DIRECTION: 6 CLOCK; D1-D2= 0.095 INCH; REF AERMAN WO 2023 360/1 N/R 2023-692458, PERFORMED REPAIR ON FRAME 16 RH LOCATED UPPER HOLE FROM DOOR STOPSDR DALA2023122010429Unknown · unknownSHIP 3273 DISC: CRACK INDICATION FOUND ON WINDSHIELD CENTER POST UPPER RADIUS RH SIDE. C/A: COMPLIED WITH ER/A 612832-14AD REV. ORIGINAL MATCHES WITH ALL STEPS ON ER/A 612832-14AD PRI REV 0 AND REV. 1 IT IS BEEN VALIDATED. PERFORMED REPAIR INSTRUCTIONS NOSE FUSDR DALA2023122010428Unknown · unknownSHIP 3273 DISC: CRACK INDICATION FOUND ON WINDSHIELD CONTINUITY FITTING LH SIDE. C/A: COMPLIED WITH ER/A 612832-14AD REV ORIGINAL MATCHES WITH ALL STEPS ON PRI 612832-14AD PRI REV 0 AND REV 1 IT HAS BEEN VALIDATED.PERFORMED REPAIR INSTRUCTION ON WINDSHIELD CONSDR DALA2023122010426Unknown · unknownSHIP 3273 DISC: CRACK INDICATION FOUND ON WINDSHIELD CENTER POST UPPER RADIUS LH SIDE. C/A: COMPLIED WITH ER/A 612832-14AD REV. ORIGINAL MATCHES WITH ALL STEPS ON ER/A 612832-14AD PRI REV 0 AND REV. 1 IT IS BEENVALIDATED. PERFORMED REPAIR INSTRUCTIONS NOSE FUSSDR CALA2023122003685Window Frame · crackedCRACK FOUND ON RIGHT HAND NO.1 WINDOW WHILE ACCOMPLISHING EA 5310-04554 OP 002. ACCOMPLISHED ON EA 5310-04554 OP 002.SDR CALA2023122003683Forging · damagedWHILE ACCOMPLISHING LH NO.1 EA 5310-04554 OPERATION 003, FOUND ON FASTENER LOCATION THAT WAS OVERSIZED ADN WOULD HAVE A SHORT EDGE DISTANCE ON TEH ASSOCIATED TRIPLER DURING INSTALLATION. A DEVIATION ECRA FOR AN OVERSIZED HOLE FOUND ON THE CROWN SKIN ERROSION DSDR AALA202402128976Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME HOLE #5 AT DOOR STOP #7 DOUBLE JOGGLE AREA AT FR 16 AND S5R. REPAIRED FRAME PER EA 350313.SDR DALA2023121910414Unknown · unknownSHIP 0670 FUSELAGE / FAIL SAFE CHORD / AT STA 1500 / BTW S-29L & S-29R / CORROSION. CORRECTIVE ACTION: REF ERA 61418514. (0115873)SDR SWI2024F00160Unknown · corrodedFUSELAGE LONGITUDINAL JOINT HAS CORROSION AT APPROXIMATELY FS319.00 AND STGR 21L AROUND GROUND STATION. (C-CHECK RO 2/18/2024) REPLACED WITH NEW BACK UP SILL AT STR 21L BETWEEN FS319.00 - FS333.00 REF CRJ-700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-SDR SWIA2024021931217Crossbeam · corrodedFS 280.00 CROSSBEAM HAS MULTIPLE AREAS OF CORROSION AS MARKED (C-CHECK RO 2/18/2024) INSTALLED LH AND RH FS280.00 CROSSBEAMS REF. DRWG CC670-34010 REV. K, CRJ 700 SRM 51-42-06-001-001-A01 AND CRJ 700 SRM 51-42-22-001-001-A01. M-337 AND SKYWEST TASK CARD 5SDR YENA2023122001613Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON AFT FRAME SEGMENT 1 AT DOOR EMERGENCY EXIT ( FWD RH, ZONE 843) CRACK L= 0.421; REF TO AEROMAN WO 2023 364/1 NR 2023-683285, THIS NON ROUTINE WAS ACCOMPLISHED EC NO. A320-52-1144.SDR YENA2023122001611Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION ON FR68 RH, DOOR STOP FITTING 1, UPPER INBOARD, HOLE 2, CRACK DIRECTION AT 7 OCLOCK; (RESOLVED ON W/O: 1271876 TASKCARD: NR-00034) REF TO AEROMAN WO 2023 364/1 NR 2023-683086, PERFORMED REPAIR LOC. FR68LH DOOR STOP FISDR YENA2023122001610Unknown · unknownDURING HEAVY MAINTENANCE: CRACK INDICATION ON FR68 RH, DOOR STOP FITTING 4, LOWER INBOARD, HOLE 4, CRACK DIRECTION AT 7 OCLOCK; (RESOLVED ON W/O: 1271876 TASKCARD: NR-00033) REF TO AEROMAN WO 2023 364/1 NR 2023-683085, PERFORMED PERMANENT REPAIR LOC FR 68 DOORSDR YENA2023122001609Unknown · unknownDURING HEAVY MAINTENANCE: CRACK: OPEN HOLE H1 FR16LH DOOR STOP FITTING LOCATION 7 AT INTERCOSTAL LAYER ONLY DIRECTION 7 O'CLOCK; REF AEROMAN NR 2023-683018 W/O:2023 364/1: PERFORMED REPAIR ON FR16LH, DOOR STOP LOCATION 7, AT INTERCOSTAL LAYER ONLY IAW A320 SRMSDR AALA202403191819Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK RIGHT HAND SIDE WINDSHIELD FRAMING CENTER POST LOWER ATTACHMENT AREA UPPER RADIUS AND LOWER RADIUS CRACKED BETWEEN FR 2 AND FR 4 AT Y0. REPLACED WINDSHIELD FRAME EA 350216.SDR SWI2024F00141Unknown · corrodedCORROSION FOUND IN THE LOWER PORTION OF FS 1015.00 STGR 27 TO STGR 25L AS MARKED (C-CHECK RO 2/18/2024) PERFORMED A SPLICE REPAIR PER REO 670-53-61-2222 REV. -- , DATED 2024-01-18. LEAK CHECKED GOOD. COMPLIED WITH SKY WEST TC 51-900-1002-SKY.SDR VNAA202312160006Drag Angle · crackedHN 120498 DISCREPANCY: FOUND AFT DRAG ANGLE TO BE CRACKED AND HAVE PREVIOUS REPAIRS INCORPORATED. THAT INTERFERE WITH INCORPORATION OF TO 52-079-003-22. CORRECTIVE ACTION: REMOVED DAMAGED, UNSERVICEABLE DRAG ANGLE AND INSTALLED NEW SERVICEABLE DRAG ANGLE PN: 6SDR SWI2024F00117Window Post · crackedTHE LH WINDSHIELD SIDE POST ON THE UPPER INBD SIDE IS CRACKED. (C-CHECK RO 2/18/2024) L/H WINDSHIELD, NEW WINDOW SIDE POST P/N 601R33223-1 INSTALLED IAW CRJ 700 SRM 51-42-21-001-001-A01 AND REFERENCE DWG CC670-33055 REV. F. COMPLIED WITH SKYWEST TASK CARDSDR AALA202401219294Splice · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR STRUCTURWE INBOARD SIDE UPPER POSITION SPLICE COUPLING AT FR 68 BETWEEN -Y1123 AND -Y1162. REPLACED SPLICE COUPLING PER SRM 51-42-11.SDR SWAA2023121832365Filler · missingEXTERNAL ELECTRICAL PLUG CUTOUT; EXTERNAL DOUBLER TAB IS MISSING AT THE LOWER LATCH STRIKER PLATE.<[01] REMOVED FASTENERS AT MISSING FILLER FROM PREVIOUS REPAIR. NO ADDITIONAL DAMAGE NOTED. FABRICATED NEW FILLER PER SRM 53-10-15-2R-4. OK TO INSTALL;[02] INSPEC
Back to JASC 5310