JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023121810355Unknown · unknownSHIP 3273 DISC: DTE ERA 612832-14AD. REPAIR AREAS OTHER THAN CONTINUITY FITTING AND OTHER THAN WINDSHIELD FRAMING PER ERA 612832-14AD. C/A: REVISE / UPDATE ERA 612832-14AD WITH DTE RESULTS PRIOR TO 90,143 TOTAL FLIGHT CYCLES. ASSOCIATED ER/A 14-612832 ADDED FOSDR DALA2023121810354Unknown · unknownSHIP 3273 DISC: INSPECTION ERA 612832-14AD. REPAIR OF WINDSHIELD FRAMING PER ERA 612832-14AD REQUIRES FOLLOW-ON INSPECTIONS PRIOR TO 57,143 TOTAL FLIGHT CYCLES AND EVERY 4,700 FLIGHT CYCLES THEREAFTER. C/A: ACCOMPLISH INSPECTIONS AT WINDSHIELD FRAMING PER ERA SDR DALA2023121810334Unknown · unknownCRACK ON BEAM 1 BTW STA Y=195 AT FWD PASSENGER DOOR. SUMMARY OF THE NRC 00081: BEAM 1 BTW STA Y=195 AT FWD PASSENGER DOOR WAS REPAIRED PER B717-200 SRM 52-10-02-2R REPAIR 7. (LP #0111304)SDR DALA2023121510306Unknown · unknownSHIP 670 INITIAL INSPECTION: CORROSION ON FRAME CLIPS STA= 879 AND BTW S- 29L TO S-28R (BILGIE AREA) AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC S/N 00486, FRAME CLIPS STA= 879 AND BTW S-29L TO S-28R (BILGIE AREA) AT FWD CARGO COMPARTMENT WAS FSDR SWAA2024011731995Pressure Deck · crackedCRACK INDICATION ON HORIZONTAL PRESSURE DECK RBL 40 STA 663 PASSENGER CABIN. CRACK LENGTH:0.312 INCH. 2023-766552<[01] TOOL USED EDDY CURRENT EQUIPMENT P/N NORTEC 600D; S/N 60009161631 DUE DATE 31/JAN/24;[02] PERFORMED PERMANENT REPAIR LOCATED BTW RBL 38 TO RBSDR UIEA2023121200984Unknown · unknownMAIN DECK, SECTION 46, ZONE 252, BTW STA 1175 AND S-12R, FRAME WITH CORROSION EVIDENCE.(<P>MAIN DECK, SECTION 46, ZONE 252, BTW STA 1175 AND S-12R, FRAME WITH CORROSION EVIDENCE THE TRE6753635 ISSUED DATE NOV19,2023 WAS PERFORMED. FAA FORM 8100-9 DATE NOV21,20SDR DALA2023121510283Unknown · unknown(LOG 0110489) AFT ENTRY DOOR CUTOUT INT STRUCTURE BS 992.8 AND S-15L ANGLE CORROSION. AFT ENTRY DOOR CUTOUT INT STRUCTURE BS 992.8 AND S-15L ANGLE WAS REPLACED I.A.W. ER/A 614271-14 REV ORIGINAL.SDR DALA2023121510279Unknown · unknown(LOG 5087096) LAV 204 CORROSION FOUND AT AFT RT LAV/ AFT DOOR POST. REPAIRED PER ERA 613837-14TR REV B.SDR DALA2023121510278Unknown · unknown(LOG 5087095) LAV 203 CORROSION FOUND AT AFT DOOR POST. REPAIRED PER ERA 613837-14TR REV B.SDR REXA2024071600539Floor Skin · crackedLH FWD EQUIPMENT COMPARTMENT FLOOR AT FS 193 IS CRACKED JUST O/B OF THE BRAKE ACCUMULATOR GAUGES REPAIRED LH FLOOR WEB IAW CRJ900 SRM 53-11-43-201-001-A01. MATERIAL USED FOR DOUBLER AND SHIM 2024-T3 0.040Ï¿½ PO# 5-5501, CLEAT 2024-T3 0.032Ï¿½ PO# W89584. COMPLSDR DALA2023121510302Unknown · unknownSHIP 0670 FUSELAGE / FAIL SAFE CHORD / AT STA 1600 / BTW S-29L & S-29R / CORROSION. CORRECTIVE ACTION: REF ERA 614190-14. (0108908)SDR SWI2024F00013Window Post · crackedL/H SIDE WINDSHIELD POST AFT LOWER ATTACHMENT CLIP HAS CRACK AT RADIUS. (C-CHECK RO 1/22/2024) REMOVED AND REPLACED L/H SIDE WINDSHIELD POST, AFT LOWER ATTACHMENT CLIP FITTING REF CRJ200 SRM 51-42-21 AND DWG#601R33007 REV-U. COMPLIED WITH 51-900-1003-SKY (SDR DALA2023121310200Unknown · unknownCORROSION ON PREVIOUS REPAIR SPLICES ON DOOR JAMB STA Y=954 BTW STRINGER 26-27RH. SUMMARY OF NRC 00698: CORROSION LEVEL 2. PREVIOUS REPAIR SPLICES ON DOOR JAMB STA Y=954 BTW STRINGER 26-27RH SPLICES (2 EA) WERE FABRICATED AND INSTALLED PER B717 SRM 53-20-15-2RSDR REXA2024031300259Former · corrodedPAX DOOR FORMER FS 320 FOUND CORRODED BETWEEN DD5 AND DD7. INSTALLED NEW SERVICEABLE FORMER PN 601R318032-5 IAW CRJ 900 SRM 51-40-11-001-001-A01, 52-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR SWAA2024012530476Service Panel · corrodedCORROSION ** EXTERNAL AFT LOWER FUSELAGE TOILET SERVICE PANEL 145AL AT BONDING WIRE ATTACHED POINT<[01] REMOVED AND REPLACED AFT LOWER FUSELAGE TOILET SERVICE PANEL 145AL AS PER AMM 52-49-07-000-801;[02] CORRECTED STEP 1. REMOVED AND INSTALLED NEW AFT LOWER FUSDR CALA2023121303632Bracket · corrodedWHILE WORKING NR 164654-0300-0006, FOUND APU INLET DOOR FRAME FORWARD STRAP CORRODED @ STA 1781 FROM S3R TO S6R. REMOVED AND REPLACED CORRODED STRAP P/N 148N3138-20 IAW B757 SRM 51-40-02 PARA 7 AND 9 SDR 1034547SDR SWI2024022000172Structure · corrodedCORROSION FOUND AT APPROXIMATELY FS 977.00 BETWEEN STGR 27 AND STGR 26L AS MARKED (C-CHECK RO 2/19/2024) REPAIRED CORROSION AT FS977 BETWEEN STGR 27 AND STGR 26L REF REO 670-53-00-715 REV -- DATE 2023-12-22 AND REO 670-53-00-290 REV -F DATE 2019/04/26. SEESDR DALA2023121210145Crossbeam · unknownSHIP 3273 DISC: BENT INTERNAL STRUCTURE CROSS BEAM AT FR 27 BTW STR 38L TO STR 41R IN FWD CARGO COMPARTMENT. C/A: REPLACED INTERNAL STRUCTURE CROSS BEAM AT FR 27 BTW STR 38L TO STR41R FWD CARGO COMPARTMENT AS PER A320 SRM 51-42-11 AND DWG: D53230829. (LP: 0104SDR EE4Y2023121018947Door Frame · crackedDURING ACCOMPLISHMENT ALLEGIANT TASK CARD 53-260-003 AND AD 2022-22-04, IT WAS FOUND AT FR68 DOOR STOP FITTING # 1 FASTENER HOLES AREA WITH CRACK INDICATION. THE PERMANENT REPAIR WAS ACCOMPLISHED IAW A320 SRM 53-41-12-300-008 AND SRM 53-41-12-300-010.THE REPAISDR AALA202404165525Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK WINDSHIELD CENTER POST LEFT HAND FRAMING UPPER RADIUS CRACKED AT FR 3 AND Y0. REPAIRED WINDSHIELD FRAME PER EA 350078.SDR AALA202403059060Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON CONTINUITY FITTING OF WINDSHIELD LOWER ATTACHMENT AREA RIGHT-HAND SIDE. PERFORMED TIME REPAIR (REPLACED) CONTINUITY FITTING OF WINDSHIELD LOWER ATTACHMENT AREA PER EA 350078.SDR AALA202403056417Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON CONTINUITY FITTING OF WINDSHIELD LOWER ATTACHMENT AREA LEFT-HAND SIDE. PERFORMED TIME LIMITED REPAIR (REPLACED) CONTINUITY FITTING OF WINDSHIELD LOWER ATTACHMENT AREA LEFT-HAND SIDE PER EA350078.SDR SWI2024022000134Door Frame · corrodedFORWARD BAGGAGE BAY LOWER SURROUND CORRODED AS MARKED (C-CHECK RO 2/19/2024) REPAIRED 2 EA. CORRODED AREAS ON THE FORWARD BAGGAGE BAY SURROUND AT MARKED AREAS REF REO 670-53-31-844 REV --,DATED 2024-01-09. SEE CONTINUATION FOR DETAILS.SDR SWIA2024021931209Landing · cracked* R/H FORWARD EQUIPMENT COMPARTMENT DOOR LANDING IS CRACKED AT THE AFT LATCH, MARKED. (C-CHECK RO 2/18/2024) REMOVED AND REPLACED WITH NEW DOOR LANDING ON R/H FORWARD EQUIPMENT COMPARTMENT PER DWG# CC670-33040, REV -G, REO# 670-53-11-1912, REV --, DATED ONSDR AALA202312121134Pressure Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED PRESSURE PLATE MIDDLE FASTENER HOLE AT FR 43 BETWEEN -Y1292 AND -Y1650. REPLACED PRESSURE PLATE PER SRM 51-42-11.SDR AALA202312127561Pressure Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED PRESSURE PLATE MIDDLE FASTENER HOLE AT FR 43 BETWEEN +Y1292 AND +Y1650. REPLACED PRESSURE PLATE PER SRM 51-42-11.SDR AALA202402276457Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAME CENTER POST LOWER NODE ATTACHMENT INTERNAL AREA RIGHT HAND SIDE FROM UPPER TENSION BOLT AT FR 2 AND Y0. REPAIRED FRAME PER EA 350076.SDR AALA202402270602Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAME CENTER POST LOWER NODE ATTACHMENT INTERNAL AREA LEFT HAND SIDE FROM UPPER TENSION BOLT AT FR 2 AND Y0. REPAIRED FRAME PER EA 350076.SDR SWI202402200127Pressure Deck · corrodedLEFT HAND PRESSURE FLOOR HAS MULTIPLE SPOTS OF CORROSION AS MARKED (C-CHECK RO 2/19/2024) REPAIRED LEFT HAND PRESSURE FLOOR BY PERFORMING REO 670-53-41-652 REV -- DATED 2023-12-27 COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKYSDR N6WA2023122103Door Frame · corrodedCORROSION AND CRACK ON FRAME 549 ATTACH FLANGE JUST ABOVE FWD CARGO DOOR. REPAIR CORROSION AND CRACK ON FRAME 549 ATTACH FLANGE JUST ABOVE FWD CARGO DOOR IAW EO C550-53MR-015.SDR AALA202312115555Drag Link · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION WAS DISCOVERED AT CENTER WING LOWER SKIN AT THE BS 540, RIGHT HAND DRAG ANGLE ATTACHMENT LOCATION. INSTALLED DRAG LINK ASSEMBLY IAW EA 349447A.SDR DALA2023120810097Unknown · unknownSHIP 6817 CORROSION ON DOUBLER (PREVIOUSLY REPAIRED) ON AFT DECK PLATE FROM BS 1680 TO 1720 AT LBL56 AT PAX CABIN FLOOR STRUCTURE. (CPAX). CORRECTIVE ACTION: SUMMARY OF NRC 00411: DOUBLER (PREVIOUSLY REPAIRED) ON AFT DECK PLATE FROM BS 1680 TO 1720 AT LBL56 ATSDR AALA202402064971Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAMING LEFT HAND LATERAL POST UPPER ATTACHMENT BETWEEN FR 4 AND FR 8 AT +Y765. REPLACED WINDSHIELD FRAME PER EA EA 349189.SDR AALA202402067874Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FLIGHT DECK WINDSHIELD FRAMING RIGHT HAND LATERAL POST UPPER ATTACHMENT BETWEEN FR 4 AND FR 8 AT -Y765. REPLACED WINDSHIELD FRAME PER EA EA 349189.SDR DALA2023120810075Unknown · unknown(LOG 0098777) LEFT SIDE VERTICAL PRESSURE DECK WEB, BETWEEN LBL25 AND LBL45, WITH A CRACK. LEFT SIDE VERTICAL PRESSURE DECK WEB BETWEEN LBL 45 LBL 25 WAS REPAIRED I.A.W B737-800 SRM 57-10-10 REPAIR 3.SDR CALA2023120803603Window Frame · crackedFOR SDR TRACKING PURPOSE ONLY "737NG LH #1 WINDOW FRAME INSPECTION AND PREVENTATIVE MOD" REF AAR N/R 9217043.SDR EE4Y2023120618941Door Frame · damagedDURING THE INSPECTION PROCESS AS PER ALLEGIANT ENGINEERING ORDER E5316-0003 REV. 01RELATED TO SB 53-1330 REV. 00, IT WAS FOUND THE FWD FUSELAGE - FR16 RHS- DOOR STOP FITTING LOCATION #1 WITH ELONGATED HOLES. THE DETAILS WERE SENT TO AIRBUS ASKING FOR REPLACEMESDR EE4Y2023120618940Door Frame · damagedDURING THE INSPECTION PROCESS AS PER ALLEGIANT ENGINEERING ORDER E5316-0003 REV. 01 RELATED TO SB 53-1330 REV. 00, IT WAS FOUND THE FWD FUSELAGE - FR16 - DOOR STOP FITTING LOCATION #1 WITH ELONGATED HOLES. THE DETAILS WERE SENT TO AIRBUS ASKING FOR REPLACEMENTSDR EE4Y2023120618942Door Frame · crackedDURING ALLEGIANT TASK INSPECTION 53-260-002 REAR FUSELAGE AFT PASS DOOR LH SIDE FR66 DOORSTOP FITTING # 6 AREA I/B UPPER FASTENER HOLE WITH CRACK WAS FOUND. COOPESA PERFORMED REPAIR IN ACCORDANCE WITH A320 SRM TASK 53-41-12-300-009. THIS REPAIR IS COVERED WITHSDR EE4Y2023120618937Door Frame · crackedDURING ALLEGIANT TASK INSPECTION 53-260-003 REAR FUSELAGE AFT PASS DOOR LH SIDE FR68 DOORSTOP FITTING # 4 AREA I/B LOWER FASTENER HOLE WITH CRACK WAS FOUND. COOPESA PERFORMED REPAIR IN ACCORDANCE A320 SRM TASK 53-41-12-300-010. THIS REPAIR IS COVERED WITH COOPSDR EE4Y2023120618936Stop Fitting · crackedDURING ALLEGIANT TASK INSPECTION 53-260-002 REAR FUSELAGE AFT PASS DOOR LH SIDE FR68DOORSTOP FITTING # 1 AREA I/B LOWER FASTENER HOLE WITH CRACK WAS FOUND. COOPESA PERFORMEDREPAIR IN ACCORDANCE A320 SRM TASK 53-41-12-300-011. DUE DEVIATION DURING REPAIRACCOMPLSDR EE4Y2023120618935Frame · crackedDURING ALLEGIANT TASK INSPECTION 53-260-002 REAR FUSELAGE AFT PASS DOOR RH SIDE FR68 DOORSTOP FITTING # 1 AREA I/B LOWER FASTENER HOLE WITH CRACK WAS FOUND. COOPESA PERFORMED REPAIR IN ACCORDANCE A320 SRM TASK 53-41-12-300-011. DUE DEVIATION DURING REPAIR ACCOSDR AALA202312110174Doubler · noneAIRCRAFT IN BASE MAINTENANCE: MODIFICATION OF LEFT HAND FRONT SPAR CHORD AND UNDERWING LONGERON, LOCATED AT BS 1035 AND STR 35 TO 37 LEFT. INSTALLATION OF DOUBLER AND REPLACEMENT UNDERWING LOWER CHORD. PER BOEING DRAWING 675W0001.SDR SWAA2023122927523Tie Clip · crackedCRACK TIE CLIP LOCATED STA277 AND STR 10R AT PASSENGER CABIN 2023-748392<[01] REPLACED TIE CLIP LOCATED STA277 AND STR 10R AT PASSENGER CABIN IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG: 141A1110 SHEET: 18 REV: - . SEE INDIVIDUAL SIGN-OFF BELOW.;[02SDR YENA2023120701553Unknown · unknownDURING HEAVY MAINTENANCE: FUSELAGE / REAR FUSELAGE / WASTE ACCESS BETWEEN FR75-76 & STGR 33L-366L / CORROSION - TEMPORARY REPAIR (CONSIDERED A MAJOR REPAIR)SDR SWIA202312130003Unknown · gougedFOUND GOUGE ON FS1162.00 FRAME REINFORCEMENT PLATE BETWEEN STGR7R AND STGR8R, ~0.6" LONG, ~0.06" WIDE, AND ~0.06" MAX DEPTH. (FILED CLOSED)COMPLIED WITH PERMANENT REPAIR TO FS1162.00 FRAME BETWEEN STGR 7R AND SSTGR 8R PER REO 690-53-71-071 REV -- DATE 2023-1SDR JR2R20231203443Doubler · corrodedSPLICE DOUBLER BETWEEN FR87 AND FR88 AT RBL48 CORRODED. REMOVED AND REPLACED.SDR AALA202401225643Door Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN R1 DOOR LOWER FORWARD FRAME DOUBLER AT BS 344, S17R. REPAIRED FRAME PER SRM 51-70-11-2R. **SUPPLEMENTAL REPORT FOR AALA202312065643 TO UPDATE SECTION 7 STA TO 294.**SDR HNAA2024011700015Unknown · unknownE012727 R/H FLOOR SEAL #6 HAS CORROSION AROUND NUT-PLATES HOLES. RAR RH FLOOR SILL #6 IAW EMB 145 SRM 51-40-02SDR HNAA2023011700014Unknown · unknownE012721 FLOOR LAV CROSSBEAM BETWEEN L/H FLOOR SEAL AND L/H BEAM GUSSET UNDERNEATH HAS CORROSION. RAR CORRODED FLOOR LAV CROSSBEAM BETWEEN L/H FLOOR SEAL AND L/H BEAM GUSSET IAW EMB 145 SRM 51-40-02
Back to JASC 5310